VS-VSUD400CW60 www.vishay.com Vishay Semiconductors FRED Pt®, Ultrafast Soft Recovery Diode Module, 400 A FEATURES • Ultrafast recovery Lug terminal anode 1 Lug terminal anode 2 • UL approved file E222165 • Designed for industrial level • Material categorization: For definitions of compliance www.vishay.com/doc?99912 see BENEFITS Base common cathode TO-244 please • Reduced RFI and EMI • Higher frequency operation • Reduced snubbing • Reduced parts count PRODUCT SUMMARY IF(AV) 400 A DESCRIPTION VR 600 V Qrr 4730 nC trr 90 ns Type Modules - Diode, FRED Pt® FRED Pt® diodes are optimized to reduce losses and EMI/RFI in high frequency power conditioning systems. The softness of the recovery eliminates the need for a snubber in most applications. These devices are ideally suited for HF welding, power converters and other applications where switching losses are significant portion of the total losses. ABSOLUTE MAXIMUM RATINGS PARAMETER Cathode to anode voltage Continuous forward current per diode Single pulse forward current per diode Maximum power dissipation Operating junction and storage temperatures SYMBOL TEST CONDITIONS MAX. UNITS 600 V VR IF(AV) TC = 25 °C 330 TC = 85 °C 230 TC = 97 °C 200 IFSM PD A 1200 TC = 25 °C 660 TC = 97 °C 280 TJ, TStg W -40 to 150 °C ELECTRICAL SPECIFICATIONS PER LEG (TJ = 25 °C unless otherwise specified) PARAMETER Breakdown voltage SYMBOL VBR TEST CONDITIONS IR = 100 μA MIN. TYP. MAX. 600 - - IF = 200 A - 1.45 2.0 IF = 400 A - 1.67 2.3 IF = 200 A, TJ = 150 °C - 1.13 1.4 UNITS V Forward voltage VFM IF = 400 A, TJ = 150 °C - 1.39 1.8 Reverse leakage current IRM TJ = 150 °C, VR = VR rated - 0.3 1.38 mA Series inductance LS From top of terminal hole to mounting plane - 5 - nH Revision: 26-Mar-14 Document Number: 93117 1 For technical questions within your region: [email protected], [email protected], [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 VS-VSUD400CW60 www.vishay.com Vishay Semiconductors DYNAMIC RECOVERY CHARACTERISTICS (TJ = 25 °C unless otherwise specified) PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. - 90 - - 240 - IF = 200 A, dIF/dt = 200 A/μs, VR = 200 V - 8.3 - IF = 200 A, dIF/dt = 200 A/μs, VR = 200 V, TJ = 150 °C - 24 - IF = 200 A, dIF/dt = 200 A/μs, VR = 200 V - 830 - IF = 200 A, dIF/dt = 200 A/μs, VR = 200 V, TJ = 150 °C - 4730 - MIN. TYP. MAX. - - 0.19 - - 0.095 - 0.10 - - 68 - g oz. TJ = 25 °C Reverse recovery time trr TJ = 150 °C Peak recovery current IRRM Reverse recovery charge Qrr IF = 200 A, dIF/dt = 200 A/μs, VR = 200 V UNITS ns A nC THERMAL - MECHANICAL SPECIFICATIONS PARAMETER SYMBOL per leg Thermal resistance, junction to case RthJC per module Thermal resistance, case to heatsink RthCS Weight UNITS °C/W - 2.4 - Mounting torque 30 (3.4) - 40 (4.6) Mounting torque center hole 12 (1.4) - 18 (2.1) Terminal torque 30 (3.4) - 40 (4.6) Vertical pull - - 80 2" lever pull - - 35 1000 1000 IR - Reverse Current (μA) IF - Instantaneous Forward Current (A) lbf · in TO-244 (TO-244AB) Case style 100 TJ = 25 °C TJ = 150 °C 10 1 lbf · in (N · m) 0 0.5 1.0 1.5 2.0 2.5 VF - Forward Voltage Drop (V) Fig. 1 - Typical Forward Voltage Drop vs. Instantaneous Forward Current (Per Leg) TJ = 150 °C 100 10 1 25 °C 0.1 0.01 0 100 200 300 400 500 600 VR - Reverse Voltage (V) Fig. 2 - Typical Reverse Current vs. Reverse Voltage (Per Leg) Revision: 26-Mar-14 Document Number: 93117 2 For technical questions within your region: [email protected], [email protected], [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 VS-VSUD400CW60 Vishay Semiconductors 8000 160 IF = 200 A Vrr = 200 V 6000 120 TJ = 150 °C Qrr (nC) Allowable Case Temperature (°C) www.vishay.com DC 80 Square wave (D = 0.50) rated VR applied 40 0 0 100 4000 2000 200 300 0 100 400 TJ = 25 °C 200 400 500 dIFdt (A/μs) Fig. 3 - Maximum Current Rating Capability (Per Leg) Fig. 6 - Typical Reverse Recovery Charge vs. dIF/dt (Per Leg) 200 40 RMS Limit IF = 200 A Vrr = 200 V 30 150 DC 100 IRR (A) Forward Power Loss (W) IDC - Current Rating (A) 300 D = 0.01 D = 0.02 D = 0.05 D = 0.10 D = 0.20 D = 0.50 50 50 100 150 TJ = 25 ˚ C 200 Forward Current (A) 0 100 200 300 400 500 dIFdt (A/μs) Fig. 4 - Forward Power Loss Characteristics 300 20 10 0 0 TJ = 150 ˚ C Fig. 7 - Typical Reverse Recovery Current vs. dIF/dt (Per Leg) IF = 200 A Vrr = 200 V 200 trr (ns) TJ = 150 ˚ C 100 TJ = 25 ˚ C 0 100 200 300 400 500 dIFdt (A/μs) Fig. 5 - Typical Reverse Recovery Time vs. dIF/dt (Per Leg) Revision: 26-Mar-14 Document Number: 93117 3 For technical questions within your region: [email protected], [email protected], [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 VS-VSUD400CW60 www.vishay.com Vishay Semiconductors VR = 200 V 0.01 Ω L = 70 μH D.U.T. D dIF/dt adjust IRFP250 G S Fig. 8 - Reverse Recovery Parameter Test Circuit ORDERING INFORMATION TABLE Device code VS-VS UD 2 1 400 C W 60 3 4 5 6 1 - Vishay Semiconductors product 2 - UD = FRED Pt® 3 - Current rating (400 = 400 A) 4 - Circuit configuration: C = Common cathode 5 - W = TO-244 wire bondable not isolated 6 - Voltage rating (60 = 600 V) CIRCUIT CONFIGURATION CIRCUIT CIRCUIT CONFIGURATION CODE CIRCUIT DRAWING Lug terminal anode 2 Two diodes common cathodes C Base common cathode Lug terminal anode 1 LINKS TO RELATED DOCUMENTS Dimensions www.vishay.com/doc?95021 Revision: 26-Mar-14 Document Number: 93117 4 For technical questions within your region: [email protected], [email protected], [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Outline Dimensions www.vishay.com Vishay Semiconductors TO-244 DIMENSIONS in millimeters (inches) 35 (1.37) REF. 13 (0.51) 7 (0.27) 6 (0.23) 17.5 (0.69) 16.5 (0.65) 40 (1.57) 80 (3.15) Ø 5.2 (Ø 0.20) 3 12.6 (0.5) Ø 7.2 (Ø 0.28) (2 places) 3 1 2 21 (0.82) 20 (0.78) ¼" - 20 UNC 9.6 (0.37) MIN. 93 (3.66) MAX. Revision: 24-Apr-15 Document Number: 95021 1 For technical questions within your region: [email protected], [email protected], [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Material Category Policy Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant. Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU. Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21 conform to JEDEC JS709A standards. Revision: 02-Oct-12 1 Document Number: 91000