VPU40 4 0 W D e s k t o p S witching Power Supplies series Universal 90-264VAC Input IEC-320-C14 3 Prong Inlet Single Outputs from 5 to 48VDC 3000V Isolation Class I LPS Efficiency Level V (Most Models) 4.21” x 1.85” x 1.19” Model Number Output Watts Output Volts Output Amps Total Regulation VPU40A-102 VPU40A-103 VPU40A-104 VPU40A-105 VPU40A-106 VPU40A-107 VPU40A-108 VPU40A-109 VPU40A-110 VPU40A-111 25 30 35 40 40 40 40 40 40 40 5V 6V 10V 12V 15V 18V 24V 30V 36V 48V 5A 5A 3.5A 3.33A 2.66A 2.22A 1.66A 1.33A 1.11A 0.83A 5% 5% 5% 5% 5% 3% 3% 3% 3% 3% Note: Low cost 3 Wire IEC320/C13 (Part Number ACCRD-C13) Input Power Cords are available for these products. Inquire to the Astrodyne Sales Depart. WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 VPU40 4 0 W D e s k t o p S witching Power Supplies INPUT SPECIFICATIONS Input Voltage Range Frequency Range Input Current Inrush Current, typ (Cold Start) Leakage Current PHYSICAL SPECIFICATIONS 90-264 VAC (Universal) 47-63 Hz Low Line (115VAC) High Line (230VAC) Low Line (115VAC) High Line (230VAC) 0.75mA MAX. @ 240 VAC, FL 0.8A 0.52A 35A max. 70A max. OUTPUT SPECIFICATIONS Voltage and Current Output Power Range Load Regulation (230Vin) Line Regulation Transient Response Temperature Coefficient Ripple/Noise Over Current Protection Start Up / Hold Up Time series See Selection Charts 0 to FL Rating +/- 7%, max. +/- 1%, max. 100Vin, FL to 1/2L 4mS +/-0.04%/°C, typ FL, 90Vin 1% Pk-Pk, max. 110-150% * 100Vin, FL 3S max. / 10mS min. Size Construction Weight 4.21” x 1.85” x 1.19” Desktop Style 9.88oz (280g) ENVIRONMENTAL SPECIFICATIONS Oper. Temperature Storage Temperature Relative Humidity EMC MTBF 0 to +40°C (FL) * 50% Load @ 70°C (See Derate Curve) -40 to +85°C * 5% to 95%, non-cond * 110Vin: FCC Part 15 Class B 220Vin: CISPR-22 Class B 100,000 Hrs DERATE CURVE GENERAL SPECIFICATIONS Input-Out Isolation Input-Ground Isolation Isolation Resistance Efficiency (FL, 230Vin) Safety Efficiency Level V 3000 VAC 1500VAC 50 Mohm min. 87%, typ (c)UL60950-1; EN60950-1 SPU40-104~111 Only All specifications are typical at nominal input, full load, and 25°C unless otherwise noted * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. WWW.ASTRODYNE.COM Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 VPU40A 4 0 W D e s k t o p S witching Power Supplies series MECHANICAL DIMENSIONS - VPU40A IEC-320-C14 INLET COAXIAL PLUG: 5.5mm outer diameter 2.1mm inner diameter, female 11mm length, center “+” -Vout +Vout VPU40x-102~105 16AWG, 4’ Long VPU40x-106~108 18AWG, 4’ Long VPU40x-106~108 18AWG, 6’ Long WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458