RELIABILITY DATA
SUMMARY: LIFETIME AND ENVIORNMENTAL TESTS
TEST ITEMS
TEST CONDITIONS
SUMMARY: LIFE EXPECTANCY
TEST TIME
NUMBR
OF UNITS
TESTED
FAILURE
RATE (%)
COMPONENT
TYPICAL LIFETIME
LCD DISPLAY
(GLASS ASSEMBLY)
50,000hr (5.7yr)
TEMPERATURE LIFETIME
60°C, 5V, 32hZ
30°C, 5V, 32hZ
7,000hr
7,000hr
50
50
0
0
LCD ELECTRONICS
100,000hr (12yr) min
HIGH TEMPERATURE
70°C
95°C
60°C
1,000hr
100hr
5,000hr
300
300
300
0
0
0
EL BACK LIGHT
5,000hr (7mo) 1, 2
CCFL BACK LIGHT
15,000hr (20mo) 2
LOW TEMPERATURE
-40°C
-30°C
100hr
1,000hr
300
300
0
0
LED BACKLIGHT
100,000hr (12yr) min
HIGH TEMPERATURE AND HUMIDITY
70°C, 95%RH
40°C, 95%RH
100hr
500hr
300
300
0
0
25 CYCLES
50
0
TEMPERATURE AND HUMIDITY
CYCLE
.5hr
.5hr
.5hr
70°C
.5hr
95%RH
-20°C
POLARIZER AND REFLECTOR RELIABILITY
70°C, DRY
90°C, DRY
1,000hr
100hr
300
300
0
0
ULTRAVIOLET LIGHT
OUTDOOR EXPOSURE
.5hr
5,000hr
50
0
25 CYCLES
50
0
HEAT SHOCK
NOTES:
1. It is recommended that the product be designed so
that the EL back light is not left on continuously.
This will greatly extend the lifo of the back light element.
2. Usable lifetime of the back light is reached when
the light output reaches 50% of the original brightness.
70°C
.5hr
-20°C
VIBRATION
10 - 50Hz, 1g, X,YX,Z DIRECTIONS
51 - 300Hz, 0.5g, X,Y,Z DIRECTIONS
1hr
50
0
MECHANICAL
50g 15ms ± X,Y,Z
3 TIMES EACH
50
0
POWER SUPPLY SEQUENCING (Graphics Modules Only)
The power supply voltages should be sequenced according to the following timing diagram. This will insure that the
internal electronics have time to begin operation before the negative voltage is applied. The sequence of events
should be as follows: Apply VDD first. When VDD is stable at 5v, apply the input signals and then apply VL/VEE. The
shut down sequence is exactly the opposite. Failure to follow this procedure may result in permanent damage to
the LCD fluid or to the CMOS electronics on the module.
1second min
1 second min
5v
VDD
0v
0 to 50mS
0 - 50mS
5v
INPUT
SIGNALS
0v
0 sec min
0 sec min
VL/VEE 0v
Minus v
NOTICE:
Specifications in this catalog are subject to change without notice. Some mechanical specifications may vary slightly from those listed in this catalog due to changes and
improvements made to the product. The most current specifications are maintained on our Web site at: www.hantronix.com.