LITTELFUSE P2500AA61L

SIDACtor® Device
RoHS
SIDACtor devices enable equipment to comply with various regulatory requirements
including GR 1089, ITU K.20, K.21 and K.45, IEC 60950, UL 60950, and TIA-968-A
(formerly known as FCC Part 68).
Electrical Parameters
Part
Number *
VDRM
Volts
VS
Volts
VT
Volts
IDRM
µAmps
IS
mAmps
IT
Amps
IH
mAmps
P2000AA61L
180
220
4
5
800
2.2
150
P2200AA61L
200
240
4
5
800
2.2
150
P2400AA61L
220
260
4
5
800
2.2
150
P2500AA61L
240
290
4
5
800
2.2
150
P3000AA61L
270
330
4
5
800
2.2
150
P3300AA61L
300
360
4
5
800
2.2
150
* “L” in part number indicates RoHS compliance. For non-RoHS compliant device, delete “L” from part number.
For surge ratings, see table below.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. IPP applies to -40 °C through +85 °C temperature range.
• IPP is a repetitive surge rating and is guaranteed for the life of the product.
• Listed SIDACtor devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• VDRM is measured at IDRM.
• VS is measured at 100 V/µs.
• Special voltage (VS and VDRM) and holding current (IH) requirements are available upon request.
Surge Ratings in Amps
Series
IPP
A
0.2x310 * 2x10 *
8x20 *
0.5x700 ** 2x10 ** 1.2x50 **
10x160 *
10x160 **
10x560 *
10x560 **
5x320 *
9x720 **
10x360 * 10x1000 * 5x310 *
ITSM
10x360 ** 10x1000 ** 10x700 ** 50 / 60 Hz
di/dt
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps/µs
20
150
150
90
50
75
75
45
75
20
500
* Current waveform in µs
** Voltage waveform in µs
Telecom Design Guide • © 2006 Littelfuse
3 - 43
www.littelfuse.com
SIDACtor Devices
This modified TO-220 package with Type 61 lead spacing offers a through-hole technology
SIDACtor protection solution.
SIDACtor® Device
Thermal Considerations
Package
Symbol
Modified
TO-220
Type 61
Parameter
Value
Unit
TJ
Operating Junction Temperature Range
-40 to +150
°C
TS
Storage Temperature Range
-65 to +150
°C
50
°C/W
RθJA
Thermal Resistance: Junction to Ambient
Capacitance Values
pF
Part Number
P2000AA61L
P2200AA61L
P2400AA61L
P2500AA61L
P3000AA61L
P3300AA61L
MIN
25
25
25
20
20
20
MAX
35
35
35
35
35
35
Note: Off-state capacitance (CO) is measured at 1 MHz with a 2 V bias.
IPP – Peak Pulse Current – %IPP
+I
IT
IS
IH
IDRM
-V
+V
VT
VDRM
VS
Peak
Value
100
tr = rise time to peak value
td = decay time to half value
Waveform = tr x td
50
Half Value
0
0
tr
td
t – Time (µs)
-I
14
12
10
IH
8
6
25 ˚C
4
2
IH (TC = 25 ˚C)
tr x td Pulse Waveform
Ratio of
Percent of VS Change – %
V-I Characteristics
0
-4
2.0
1.8
1.6
1.4
25 ˚C
1.2
1.0
0.8
0.6
0.4
-40 -20 0
-6
-8
-40 -20
0
20 40 60 80 100 120 140 160
Junction Temperature (TJ) – ˚C
Normalized VS Change versus Junction Temperature
www.littelfuse.com
20 40 60 80 100 120 140 160
Case Temperature (TC) – ˚C
Normalized DC Holding Current versus Case Temperature
3 - 44