Primary Wire General Purpose Wiring for OEM & Transportation Applications Prestolite Wire® Brand Primary Wire is ideal for general purpose wiring for passenger cars and light trucks, agricultural tractors, boats, buses, agricultural tractors, construction, locomotive and off-road vehicles. General Cable’s Prestolite Wire single, duplex and bonded parallel/multi-conductor primary wire is available in a variety of gauge sizes and colors with premium-grade PVC insulation and can be shipped on OEM length reels. Since 1911, Prestolite Wire® has been engineering a complete line of wire and cable, electrical components, wire harnesses and fully assembled electronic modules and systems to serve the global transportation market and the automotive aftermarket. Learn more at www.prestolitewire.com. Applications • Intended as general purpose wiring for use at 60 volts DC or less in a surface vehicle’s electrical system in areas such as: • Fuel Tanks •Cabins/Chassis •Transmissions • Instrument Panels •Engines • Air Bags • Steering Wheels • Seat Pre-Tensioners • Sliding Door Sensors •Speakers • Electronic Fan Drives • Knock Sensors • Fuse Links • SAE, ISO, JASO and DIN Wire • Oxygen Sensors Features • Thin and ultra-thin wall design construction • Excellent heat-resistant insulation • Flexible conductor stranding with high-flex life • Impervious to oil, grease and diesel fumes • High abrasion-resistant insulation • High-temperature lead- and heavy metal-free insulation • Multi-conductor cable construction • Dual wall design construction • Lightweight and small bundle sizes Compliances Meets and exceeds the following requirements: • Conforms to SAE J1128 Type GPT • RoHS Complaint Primary Wire ISO 6722 Class A, B, C & D Thick Wall ISO 6722 Class A, B, C & D Thin Wall FPO FPO SPECIFICATIONS SPECIFICATIONS mm2 NUMBER OF STRANDS 0.5 0.75 1 1.5 2 2.5 3 4 5 6 10 19 19 19 30 19 50 19 56 19 84 75 INSULATION THICKNESS in mm 0.60 0.60 0.60 0.60 0.60 0.70 0.70 0.80 0.80 0.80 1.00 15.24 15.24 15.24 15.24 15.24 17.78 17.78 20.32 20.32 20.32 25.40 MAXIMUM O.D. in mm 2.30 2.50 2.70 3.00 3.30 3.60 4.10 4.40 4.90 5.00 6.50 58.42 63.50 68.58 76.20 83.82 91.44 104.14 111.76 124.46 127.00 165.10 Chrysler Specification MS-9502 mm2 NUMBER OF STRANDS 0.5 0.75 1 1.5 2 2.5 3 4 5 6 10 19 19 19 30 19 50 19 56 19 84 75 20 18 16 14 12 10 7 x 28 19 x .0092 19 x 29 19 x 27 19 x 25* 19 x 23* 0.016 0.016 0.016 0.016 0.018 0.021 0.41 0.41 0.41 0.41 0.46 0.53 MAXIMUM O.D. in mm 0.070 0.078 0.088 0.103 0.128 0.156 1.78 1.98 2.24 2.62 3.25 3.96 AWG STRANDING 18 16 14 12 10 19 x .0092* 19 x 29* 19 x 27* 19 x 25* 105 x 30 7 x 30 7 x 28 19 x .0092 19 x 29 19 x 27 0.010 0.010 0.010 0.010 0.012 0.25 0.25 0.25 0.25 0.30 0.037 0.040 0.040 0.046 0.048 0.94 1.02 1.02 1.17 1.22 MAXIMUM O.D. in mm 0.133 0.148 0.165 0.201 0.226 3.38 3.76 4.19 5.11 5.74 *Flexible stranding available. SPECIFICATIONS SPECIFICATIONS INSULATION THICKNESS in mm INSULATION THICKNESS in mm FPO FPO STRANDING 43.18 48.26 53.34 60.96 71.12 76.20 86.36 96.52 106.68 109.22 152.40 Ford Specification ESA-M1L77-A Ford Specification ESB-M177-A2 (Anti-Fogging) Ford Specification WSB-M1L134-A1 Chrysler Specification MS-9532 22 20 18 16 14 1.70 1.90 2.10 2.40 2.80 3.00 3.40 3.80 4.20 4.30 6.00 SPECIFICATIONS INSULATION THICKNESS in mm *Flexible stranding available for 12 AWG and 10 AWG. AWG 7.11 7.62 7.62 7.62 8.89 8.89 10.16 10.16 10.16 10.16 12.19 FPO SPECIFICATIONS STRANDING 0.28 0.30 0.30 0.30 0.35 0.35 0.40 0.40 0.40 0.40 0.48 MAXIMUM O.D. in mm Chrysler Specification MS-9673 FPO AWG INSULATION THICKNESS in mm MAXIMUM O.D. in mm 0.050 0.058 0.066 0.077 0.095 1.27 1.47 1.68 1.96 2.41 AWG STRANDING 20 18 16 14 41 x 36 65 x 36 65 x 34 65 x 32 INSULATION THICKNESS in mm 0.020 0.023 0.023 0.023 0.51 0.58 0.58 0.58 MAXIMUM O.D. in mm 0.078 0.087 0.102 0.122 1.98 2.21 2.59 3.10 Ford Specification WSS-M1L135-A1 FPO SPECIFICATIONS AWG STRANDING 22 20 18 16 14 7 x 30 7 x 28 19 x .0092 19 x 29 19 x 27 INSULATION THICKNESS in mm 0.10 0.10 0.10 0.10 0.12 2.54 2.54 2.54 2.54 3.05 MAXIMUM O.D. in mm 0.050 0.058 0.066 0.077 0.095 1.27 1.47 1.68 1.96 2.41 Primary Wire SAE J1128, Type GPT SAE J1128, Type GXL FPO FPO SPECIFICATIONS AWG STRANDING 20 18 16 14 12 10 7 x 28 16 x 30 19 x 29 19 x 27 19 x 25 19 x 23 SPECIFICATIONS INSULATION THICKNESS in mm 0.023 0.023 0.023 0.023 0.026 0.031 0.58 0.58 0.58 0.58 0.66 0.79 NOMINAL O.D. in mm 0.084 0.092 0.103 0.117 0.142 0.175 2.13 2.34 2.62 2.97 3.61 4.45 SAE J1128, Type HDT AWG STRANDING 20 18 16 14 12 10 7 x 28 16 x 30 19 x 29 19 x 27 19 x 25 19 x 23 20 18 16 14 12 10 7 x 28 16 x 30 19 x 29 19 x 27 19 x 25 19 x 23 0.023 0.023 0.023 0.023 0.026 0.031 0.58 0.58 0.58 0.58 0.66 0.79 NOMINAL O.D. in mm 0.036 0.037 0.040 0.041 0.046 0.046 0.91 0.94 1.02 1.04 1.17 1.17 AWG STRANDING 20 18 16 14 12 10 8 6 7 x 28* 16 x 30* 19 x 29* 19 x 27* 19 x 25*+ 19 x 23** 19 x 21** 37 x 21** 7 x 28 16 x 30 19 x 29 19 x 27 19 x 25 19 x 23 19 x 21 INSULATION THICKNESS in mm 0.029 0.030 0.032 0.035 0.037 0.041 0.043 0.74 0.76 0.81 0.89 0.94 1.04 1.09 in 0.096 0.107 0.120 0.141 0.163 0.195 0.231 2.44 2.72 3.05 3.58 4.14 4.95 5.87 22 20 18 16 14 12 10 7 x 30 7 x 28 19 x .0092 19 x 29 19 x 27 19 x 25 19 x 23 0.016 0.016 0.016 0.016 0.016 0.018 0.021 0.41 0.41 0.41 0.41 0.41 0.46 0.53 0.116 0.127 0.139 0.155 0.184 0.213 0.258 0.321 2.95 3.23 3.53 3.94 4.67 5.41 6.55 8.15 AWG STRANDING 22 20 7 x 30 7 x 28 19 x .0092 (or) 16 x 30 19 x 29 19 x 27 19 x 25 19 x 23 19 x 21 18++ INSULATION THICKNESS in mm 0.016 0.016 0.41 0.41 in NOMINAL O.D. mm 0.062 0.070 1.57 1.78 0.016 0.41 0.078 1.98 0.016 0.016 0.018 0.021 0.022 0.41 0.41 0.46 0.53 0.56 0.088 0.103 0.128 0.156 0.191 2.24 2.62 3.25 3.96 4.85 * Not available for Chrysler MS-8288. ** Available with or without a separator. + Available for SAE J1128 and Chrysler MS-8288 only. ++ Available with either 16 or 19 bare or tinned strands to meet SAE J1128 and Ford ESB-M1L123-A. SPECIFICATIONS INSULATION THICKNESS in mm 0.94 0.94 1.04 1.04 1.17 1.17 1.42 1.57 NOMINAL O.D. mm SPECIFICATIONS 16 14 12 10** 8**+ FPO STRANDING 0.037 0.037 0.041 0.041 0.046 0.046 0.056 0.062 in FPO NOMINAL O.D. mm SAE J1128, Type TWP AWG INSULATION THICKNESS in mm SAE J1128, Type TXL SPECIFICATIONS 20 18 16 14 12 10 8 2.13 2.31 2.69 2.97 3.63 4.45 * Tinned copper conductors. ** Bare copper conductors with paper sleeve. + Includes Mylar separator. FPO STRANDING 0.084 0.091 0.106 0.117 0.143 0.175 SPECIFICATIONS INSULATION THICKNESS in mm SAE J1128, Type SXL AWG 0.58 0.58 0.58 0.58 0.66 0.79 NOMINAL O.D. mm FPO SPECIFICATIONS STRANDING 0.023 0.023 0.023 0.023 0.026 0.031 in SAE J1128, Type HTS (Fusible Links - SAE J156a) FPO AWG INSULATION THICKNESS in mm in NOMINAL O.D. mm 0.062 0.070 0.078 0.089 0.103 0.126 0.155 1.57 1.78 1.98 2.26 2.62 3.20 3.94 Global Reach General Cable, a leading wire and cable innovator for over 170 years, serves customers through a network of 38 manufacturing facilities in our core markets and has worldwide sales representation and distribution. The Company is dedicated to the production of high-quality aluminum, copper and fiber optic wire and cable and systems solutions for the energy, construction, industrial, specialty and communications sectors. In addition to our strong brand recognition and strengths in technology and manufacturing, General Cable is also competitive in such areas as distribution and logistics, marketing, sales and customer service. This combination enables General Cable to better serve its customers as they expand into new geographic markets. 4 Tesseneer Drive One Prestolite Drive Highland Heights, KY 41076 Paragould, AR 72450 Phone: 800.498.3132 Phone: 800.952.3842 www.prestolitewire.com www.generalcable.com ©2015. General Cable Technologies Corporation. Highland Heights, KY 41076. GENERAL CABLE and PRESTOLITE WIRE BRAND are trademarks of General Cable Technologies Corporation. All rights reserved. Printed in U.S.A. Form No: AUT-XXXX-0215 48416