PANASONIC GX-8M

811
FIBER
SENSORS
Cylindrical Compact Inductive Proximity Sensor
GX SERIES
Related Information
■■General terms and conditions............ F-17
■■Glossary of terms........................ P.1386~
Amplifier Built-in
■■Sensor selection guide.................. P.757~
■■General precautions...................... P.1405
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Recognition
Conforming to
EMC Directive
MICRO
PHOTOELECTRIC
SENSORS
Excluding GX-4S□ and
5 m cable length type
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
panasonic-electric-works.net/sunx
Robust enclosure and flexible cable
types are also available
VARIETIES
GX-3S□
Miniature
GX-3S□ is an amplifier built-in inductive proximity sensor
having a diameter of just ø3.8 mm ø0.150 in.
FA COMPONENTS
MACHINE VISION
SYSTEMS
GX-F/H
GXL
GL
GX-U/GX-FU/
GX-N
GX
GX-4S□
Robust housing
The GX-4S□ uses a robust stainless steel enclosure.
The tightening torque can be 0.58 N·m or less.
(2 times compared with conventional models)
Tightening torque: 0.58 N·m or less
UV CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
Amplifierseparated
Flexible cable Metal embedding
type available possible
Set screw
M3(Cup-point)
A
ø3.8 mm ø0.150 in
Set screw tightening position
A: 5 to 10 mm 0.197 to 0.394 in
from the sensor end
BASIC PERFORMANCE
ENVIRONMENTAL RESISTANCE
GX-8ML□
Long sensing range
The non-shielded type (GX-8ML□) has twice the sensing
range of the shielded type (GX-8M□), although having
the same size. Hence, it allows margin against sensing
distance variations.
Shielded type
GX-8M□
Robust enclosure
[Stainless steel (SUS304)]
[ø4.4 ø0.173 (length: 30 mm 1.181 in)]
Operation indicator (Red)
Tighten the set screw
from a direction perpendicular
to the operation indicator.
1 mm
0.039 in
Non-shielded type
GX-8ML□
2 mm
0.079 in
Ten times greater bending durability
(Compared with conventional models) GX-□-R
The bending durability of the cable to repeated bending
has been increased tenfold by using special alloy cores
for the cable.
Cylindrical Compact Inductive Proximity Sensor
GX SERIES
APPLICATIONS
812
FIBER
SENSORS
Sensing screws on cassette
Sensing the punch of a die
Counting parts
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
ORDER GUIDE
SENSOR
OPTIONS
Type
Appearance
(mm in)
Sensing range (Note)
Maximum operation distance
ø3.8
ø0.150
0.8 mm 0.031 in
Shielded type
Non-threaded type
30
1.181
Robust enclosure type
0.8 mm 0.031 in
ø4.4
ø0.173
30
1.181
1 mm 0.039 in
ø5.4
ø0.213
30
1.181
Output
GX-3S
GX-3SB
Output
operation
Normally open
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
Normally closed
STATIC
CONTROL
DEVICES
GX-4S
Normally open
ENDOSCOPE
GX-4SB
Normally closed
12 to 24 V DC
±10 %
(0 to 0.8 mm 0 to 0.031 in)
(0 to 0.6 mm 0 to 0.024 in)
1 mm 0.039 in
M8
30
1.181
GX-5S
Normally open
10 to 30 V DC
0.8 mm 0.031 in
30
1.181
Threaded type
(0 to 0.6 mm 0 to 0.024 in)
Supply
voltage
LASER
MARKERS
PLC /
TERMINALS
M5
Non-shielded type
(0 to 0.6 mm 0 to 0.024 in)
Stable sensing range
Model No.
(0 to 0.8 mm 0 to 0.031 in)
GX-5SB
GX-5M
NPN
open-collector
transistor
Normally closed
Normally open
2 mm 0.079 in
30
1.181
(0 to 1.6 mm 0 to 0.063 in)
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
12 to 24 V DC
±10 %
GX-5MB
Normally closed
GX-8M
Normally open
GX-8MB
Normally closed
10 to 30 V DC
M8
HUMAN
MACHINE
INTERFACES
GX-8ML
Normally open
GX-8MLB
Normally closed
Note: The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient
temperature drift and/or supply voltage fluctuation.
UV
CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
Amplifierseparated
GX-F/H
GXL
GL
GX-U/GX-FU/
GX-N
GX
813
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
Flexible cable type
Flexible cable type is also available for shielded type.
When ordering this type, suffix “-R” to the model No.
(e.g.) Flexible cable type of GX-3S is “GX-3S-R”.
5 m 16.404 ft cable length type
5 m 16.404 ft cable length type (standard: 3 m 9.843 ft) is also available. (excluding GX-4SB)
When ordering this type, suffix “-C5” to the model No.
(e.g.) 5 m 16.404 ft cable length type of GX-3S is “GX-3S-C5”.
Refer to table below for 5 m 16.404 ft cable length type of flexible cable type sensor.
•Table of model Nos.
Type
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
Shielded
type
Standard
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
Amplifierseparated
GX-F/H
GXL
GL
GX-U/GX-FU/
GX-N
GX
Flexible cable of
5 m 16.404 ft cable length type
GX-3S
GX-3S-R-C5
GX-3SB
GX-3SB-R-C5
GX-4S
GX-4S-R-C5
GX-4SB
GX-5S
GX-5SB
Threaded type
WIRE-SAVING
SYSTEMS
GX SERIES
ORDER GUIDE
Non-threaded type
FIBER
SENSORS
Cylindrical Compact Inductive Proximity Sensor
GX-5M
GX-5MB
–
GX-5S-R-C5
–
GX-5M-R-C5
–
GX-8M
GX-8M-R-C5
GX-8MB
GX-8MB-R-C5
Accessories
•MS-SS3 (Sensor mounting bracket for GX-3S type)
•MS-SS3-2 (C bracket for GX-3S type)
•MS-SS5 (Sensor mounting bracket for GX-5S type)
•MS-SS3
•MS-SS5
•MS-SS3-2
By using the C bracket, the applicable
tightening force can be doubled.
Cylindrical Compact Inductive Proximity Sensor
GX SERIES
814
SPECIFICATIONS
FIBER
SENSORS
LASER
SENSORS
Non-threaded type
Shielded type
Type
Flexible cable
Flexible cable
Model No. GX-3S GX-3SB GX-3S-R GX-3SB-R GX-4S GX-4SB GX-4S-R GX-4SB-R GX-5S GX-5SB GX-5S-R GX-5SB-R
Item
Max. operation distance (Note 2)
0.8 mm 0.031 in ±15 %
Stable sensing range (Note 2)
Standard sensing object
Hysteresis
Supply voltage
0 to 0.6 mm 0 to 0.024 in
0 to 0.8 mm 0 to 0.031 in
Iron sheet 5 × 5 × t 1 mm 0.197 × 0.197 × t 0.039 in
Iron sheet 6 × 6 × t 1 mm 0.236 × 0.236 × t 0.039 in
20 μm 0.787 mil or less
8 μm 0.315 mil or less
12 to 24 V DC ±10 % Ripple P-P 10 % or less
10 to 30 V DC Ripple P-P 10 % or less
Current consumption
Utilization category
Output operation
–
Incorporated
1 kHz
1.5 kHz
Operation indicator
3 (Industrial environment)
Protection
–25 to + 70 °C –13 to +158 °F, Storage: –25 to +80 °C –13 to +176 °F
Ambient humidity
35 to 95 % RH, Storage: 35 to 95 % RH
Shock resistance
Temperature
characteristics
Voltage
characteristics
Material
Cable
Cable extension
Weight
Accessories
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
STATIC
CONTROL
DEVICES
ENDOSCOPE
35 to 85 % RH, Storage: 35 to 95 % RH
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
500 V AC for one min. between all supply terminals connected together and enclosure
FA
COMPONENTS
5 MΩ, or more, with 250 V DC megger between all supply terminals connected
together and enclosure
Vibration resistance
INDUCTIVE
PROXIMITY
SENSORS
EN 60947-5-2
EMC
Voltage withstandability
PRESSURE /
FLOW
SENSORS
PLC /
TERMINALS
IP67 (IEC)
Ambient temperature
LIGHT
CURTAINS
LASER
MARKERS
Red LED (lights up when the output is ON)
Pollution degree
AREA
SENSORS
MEASUREMENT
SENSORS
Normally Normally Normally Normally Normally Normally Normally Normally Normally Normally Normally Normally
open
closed
open
closed
open
closed
open
closed
open
closed
open
closed
Max. response frequency
Insulation resistance
NPN open-collector transistor
• Maximum sink current: 200 mA (Note 3)
• Applied voltage: 30 V DC or less
(between output and 0 V)
• Residual voltage: 1.5 V or less
(at 200 mA sink current)
0.4 V or less
(at 50 mA sink current)
DC-12 or DC-13
Short-circuit protection
MICRO
PHOTOELECTRIC
SENSORS
PARTICULAR
USE
SENSORS
15 mA or less
NPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 0.4 V or less (at 50 mA sink current)
Output
Sensing
range
variation
1 mm 0.039 in ±15 %
15 % or less of operation distance (with standard sensing object)
Repeatability
Environmental resistance
Flexible cable
PHOTOELECTRIC
SENSORS
50 MΩ, or more, with 500 V DC megger between all
supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
200 m/s acceleration (20 G approx.) in X, Y and Z directions for ten times each
2
Over ambient temperature range –25 to +70 °C –13 to +158 °F: Within ±20 % of
sensing range at +20 °C +68 °F
Within ±2 % for ±10 % fluctuation of the supply voltage
Enclosure: Stainless steel (SUS304), Resin part: TPX
300 m/s2 acceleration (30 G approx.) in
X, Y and Z directions for ten times each
Over ambient temperature range –25 to+70 °C –13 to
+158 °F: Within ±15 % of sensing range at +20 °C +68 °F
Within ±2.5 % for ±15 % fluctuation of
the supply voltage
Enclosure: Brass (Nickel plated)
Resin part: ABS
0.08 mm2 3-core oil, heat 0.1 mm2 3-core flexible, oil 0.08 mm2 3-core oil, heat 0.1 mm2 3-core flexible, oil 0.14 mm2 3-core oil, heat 0.15 mm2 3-core flexible, oil
and cold resistant cabtyre and heat resistant cabtyre and cold resistant cabtyre and heat resistant cabtyre and cold resistant cabtyre and heat resistant cabtyre
cable, 3 m 9.843 ft long cable, 3 m 9.843 ft long
cable, 3 m 9.843 ft long cable, 3 m 9.843 ft long
cable, 3 m 9.843 ft long cable, 3 m 9.843 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight: 30 g approx.
MS-SS3 (Sensor mounting bracket): 1 pc.
MS-SS3-2 (C bracket): 1 pc.
Net weight: 55 g approx.
–
MS-SS5 (Sensor mounting bracket): 1 pc.
Notes:1)Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient
temperature drift and/or supply voltage fluctuation.
3)The maximum sink current varies depending on the ambient temperature. Refer to “I/O CIRCUIT AND WIRING DIAGRAMS” for details.
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
Amplifierseparated
GX-F/H
GXL
GL
GX-U/GX-FU/
GX-N
GX
815
Cylindrical Compact Inductive Proximity Sensor
SPECIFICATIONS
FIBER
SENSORS
LASER
SENSORS
Threaded type
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
Type
Stable sensing range (Note 2)
Standard sensing object
Hysteresis
INDUCTIVE
PROXIMITY
SENSORS
Repeatability
Supply voltage
Output operation
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
Short-circuit protection
Selection
Guide
Amplifier
Built-in
Environmental resistance
Ambient temperature
UV
CURING
SYSTEMS
Ambient humidity
Insulation resistance
Vibration resistance
Shock resistance
Sensing
range
variation
GX-F/H
Cable
8 µm 0.315 mil or less
40 µm 1.575 mil or less
10 to 30 V DC Ripple P-P 10 % or less
15 mA or less
NPN open-collector transistor
• Maximum sink current: 200 mA (Note 3)
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1.5 V or less (at 200 mA sink current)
0.4 V or less (at 50 mA sink current)
DC-12 or DC-13
Normally Normally Normally Normally Normally Normally Normally Normally
open
closed
open
closed
open
closed
open
closed
–
Normally open
Normally closed
Incorporated
1 kHz
500 Hz
Red LED (lights up when the output is ON)
3 (Industrial environment)
IP67 (IEC)
– 25 to +70 °C –13 to +158 °F, Storage: – 25 to +80 °C – 13 to +176 °F
35 to 95 % RH, Storage: 35 to 95 % RH
35 to 85 % RH, Storage: 35 to 95 % RH
500 V AC for one min. between all supply terminals connected together and enclosure
5 MΩ, or more, with 250 V DC megger between all
supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected
together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
200 m/s2 acceleration (20 G approx.) in
X, Y and Z directions for ten times each
300 m/s2 acceleration (30 G approx.) in
X, Y and Z directions for ten times each
300 m/s2 acceleration (30 G approx.) in
X, Y and Z directions for three times each
Temperature
characteristics
Over ambient temperature range – 25 to +70 °C –13 to
+158 °F: Within ±20 % of sensing range at +20 °C +68 °F
Over ambient temperature range –25 to +70 °C –13 to +158 °F:
% of sensing range at +20 °C +68 °F
Within +15
–10
Voltage
characteristics
Within ±2 % for ±10 % fluctuation of the
supply voltage
Within ±2.5 % for ±15 % fluctuation of the supply voltage
Enclosure: Brass (Nickel plated)
Resin part: TPX
Enclosure: Brass (Nickel plated)
Resin part: ABS
GXL
GX
20 µm 0.787 mil or less
12 to 24 V DC ±10 % Ripple P-P 10 % or less
EN 60947-5-2
Voltage withstandability
Material
GL
10 % or less of operation distance (with standard sensing object)
EMC
Amplifierseparated
GX-U/GX-FU/
GX-N
0 to 1.6 mm 0 to 0.063 in
Pollution degree
HUMAN
MACHINE
INTERFACES
MACHINE
VISION
SYSTEMS
0 to 0.8 mm 0 to 0.031 in
Operation indicator
Protection
FA
COMPONENTS
0 to 0.6 mm 0 to 0.024 in
Iron sheet 5 × 5 × t 1 mm 0.197 × 0.197 × t 0.039 in Iron sheet 8 × 8 × t 1 mm 0.315 × 0.315 × t 0.039 in Iron sheet 12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in
Max. response frequency
PLC /
TERMINALS
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
2 mm 0.079 in ±15 %
Utilization category
MEASUREMENT
SENSORS
GX-8MLB
1 mm 0.039 in ±15 %
NPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less
(between output and 0V)
• Residual voltage: 0.4 V or less
(at 50 mA sink current)
WIRE-SAVING
SYSTEMS
GX-8ML
0.8 mm 0.031 in ±15 %
Current consumption
Output
Non-shielded type
Flexible cable
15 % or less of operation distance
(with standard sensing object)
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
Shielded type
Flexible cable
Model No. GX-5M GX-5MB GX-5M-R GX-5MB-R GX-8M GX-8MB GX-8M-R GX-8MB-R
Item
Max. operation distance (Note 2)
PRESSURE /
FLOW
SENSORS
PARTICULAR
USE
SENSORS
GX SERIES
Cable extension
Weight (Note 4)
Accessories
0.08 mm2 3-core oil, heat 0.1 mm2 3-core flexible, oil 0.14 mm2 3-core oil, heat 0.15 mm2 3-core flexible, oil
2
and cold resistant cabtyre and heat resistant cabtyre and cold resistant cabtyre and heat resistant cabtyre 0.14 mm 3-core, oil, heat and cold
resistant
cabtyre cable, 3 m 9.843 ft long
cable, 3 m 9.843 ft long
cable, 3 m 9.843 ft long
cable, 3 m 9.843 ft long
cable, 3 m 9.843 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight: 30 g approx.
Extension up to total 100 m 328.084 ft is
possible with 0.14 mm2, or more, cable.
Net weight: 60 g approx.
Nut: 2 pcs.
Nut: 2 pcs.
Nut: 2 pcs.
Nut: 2 pcs.
Toothed lock washer: 1 pc. Toothed lock washer: 2 pcs. Toothed lock washer: 1 pc. Toothed lock washer: 2 pcs.
Nut: 2 pcs.
Toothed lock washer: 1 pc.
Notes:1)Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient
temperature drift and/or supply voltage fluctuation.
3)The maximum sink current varies depending on the ambient temperature. Refer to “I/O CIRCUIT AND WIRING DIAGRAMS” for details.
4)The given weight of the threaded type includes the weight of two nuts and one toothed lock washer.
Cylindrical Compact Inductive Proximity Sensor
GX SERIES
816
I/O CIRCUIT AND WIRING DIAGRAMS
FIBER
SENSORS
LASER
SENSORS
GX-5S□ GX-8M□ GX-8ML□
I/O circuit diagram
PHOTOELECTRIC
SENSORS
Wiring diagram
MICRO
PHOTOELECTRIC
SENSORS
Color code
(Brown) +V
Brown
Load
(Black) Output
Tr
200 mA max. (Note)
ZD
+
–
200
•If a capacitor of 1 µF or more is connected between 0 V and
output or between +V and output, connect a 100 Ω resistor in
series as shown below.
1 μF or more
(Black) Output
Signal
100Ω
(Blue) 0 V
Internal circuit
1 μF or more
0V
Users’ circuit
10 to 30 V DC
Note: The maximum sink current varies depending on the ambient
temperature.
Symbols … D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr: NPN output transistor
+V
AREA
SENSORS
Blue
Users’ circuit
(Brown) +V
+
–
(Blue) 0 V
Internal circuit
Load
Black
10 to 30 V DC
Without the resistor, the shortcircuit protection is activated by
the charge or discharge current
of the capacitor, so that it
results in delaying the response
whenever the sensor switches.
The connected resistor solves
this problem.
Max. sink current (mA)
Sensor circuit
D
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
100
0
LIGHT
CURTAINS
SENSOR
OPTIONS
–25
–13
+55
+131
SIMPLE
WIRE-SAVING
UNITS
+70
+158
WIRE-SAVING
SYSTEMS
Ambient temperature (°C °F)
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
GX-3S□ GX-4S□ GX-5M□
I/O circuit diagram
HUMAN
MACHINE
INTERFACES
Wiring diagram
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
Color code
Sensor circuit
D
ZD
Tr
(Brown) +V
Load
(Black) Output (Note)
50mA max.
Brown
+
–
12 to 24 V DC
±10 %
(Blue) 0 V
Internal circuit
Black
Load
FA
COMPONENTS
+
–
Blue
12 to 24 V DC
±10 %
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Users’ circuit
Note: GX-3S□, GX-4S□ and GX-5M□ do not incorporate a short-circuit
protection circuit at the output. Do not connect them directly to a
power supply or a capacitive load.
Symbols … D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr: NPN output transistor
Selection
Guide
Amplifier
Built-in
Amplifierseparated
GX-F/H
GXL
GL
GX-U/GX-FU/
GX-N
GX
817
Cylindrical Compact Inductive Proximity Sensor
SENSING CHARACTERISTICS (TYPICAL)
FIBER
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
2
0.079
Standard sensing object
Iron sheet 5 × 5 × t 1 mm
0.197 × 0.197 × t 0.039 in
1
0.039
ℓ
0
4
0.157
PARTICULAR
USE
SENSORS
ENDOSCOPE
LASER
MARKERS
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
1
0.039
Selection
Guide
Amplifierseparated
GXL
Iron sheet
a × a mm a × a in
t 1 mm
t 0.039 in
1
0.039
5
15
10
0.197
0.591
0.394
Sensing object side
length a (mm in)
20
0.787
2
0.079
1
0.039
2
0.079
As the sensing object size becomes smaller than
the standard size (iron sheet 8 × 8 × t 1 mm
0.315 × 0.315 × t 0.039 in), the sensing range
shortens as shown in the left figure.
1
0.039
0
2
0
2
4
0.079
0.079
0.157
Left
Center
Right
Operating point ℓ (mm in)
Iron sheet
a × a mm a × a in
t 1 mm
L
t 0.039 in
5
15
10
0.197
0.591
0.394
Sensing object side
length a (mm in)
20
0.787
GX-8ML□
Sensing field
Correlation between sensing object size and sensing range
GL
2
0.079
Standard sensing object Iron sheet
12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in
ℓ
L
1
0.039
0
4
0.157
2
0
2
4
0.079
0.079
0.157
Left
Center
Right
Operating point ℓ (mm in)
Sensing range L (mm in)
Setting distance L (mm in)
GX-U/GX-FU/
GX-N
GX
As the sensing object size becomes smaller than
the standard size (iron sheet 6 × 6 × t 1 mm
0.236 × 0.236 × t 0.039 in), the sensing range
shortens as shown in the left figure.
Correlation between sensing object size and sensing range
Standard sensing object
Iron sheet
8 × 8 × t 1 mm
0.315 × 0.315 × t 0.039 in
ℓ
L
0
4
0.157
Amplifier
Built-in
GX-F/H
2
0.079
0
2
0
2
4
0.079
0.079
0.157
Left
Center
Right
Operating point ℓ (mm in)
Sensing field
Setting distance L (mm in)
UV
CURING
SYSTEMS
20
0.787
GX-8M□
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
15
5
10
0.591
0.197
0.394
Sensing object side
length a (mm in)
Correlation between sensing object size and sensing range
Standard sensing object
Iron sheet
6 × 6 × t 1 mm
0.236 × 0.236 × t 0.039 in
ℓ
L
2
0.079
0
4
0.157
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
Iron sheet
a × a mm a × a in
t 1 mm
L
t 0.039 in
As the sensing object size becomes smaller than
the standard size (iron sheet 5 × 5 × t 1 mm
0.197 × 0.197 × t 0.039 in), the sensing range
shortens as shown in the left figure.
1
0.039
0
2
0
2
4
0.079
0.079
0.157
Left
Center
Right
Operating point ℓ (mm in)
Sensing field
Setting distance L (mm in)
STATIC
CONTROL
DEVICES
L
2
0.079
GX-5S□
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
Correlation between sensing object size and sensing range
Sensing range L (mm in)
AREA
SENSORS
Sensing field
Sensing range L (mm in)
MICRO
PHOTOELECTRIC
SENSORS
GX-3S□ GX-4S□ GX-5M□
Sensing range L (mm in)
PHOTOELECTRIC
SENSORS
Setting distance L (mm in)
LASER
SENSORS
GX SERIES
As the sensing object size becomes smaller than
the standard size (iron sheet 12 × 12 × t 1 mm
0.472 × 0.472 × t 0.039 in), the sensing range
shortens as shown in the left figure.
2
0.079
1
0.039
0
Iron sheet
a × a mm a × a in
t 1 mm
L
t 0.039 in
10
30
20
0.394
1.181
0.787
Sensing object side
length a (mm in)
40
1.575
Cylindrical Compact Inductive Proximity Sensor
PRECAUTIONS FOR PROPER USE
•Never use this product as a sensing device
for personnel protection.
•In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
FIBER
SENSORS
LASER
SENSORS
Mounting with nut
•Note that the maximum tightening torque differs
according to the location of the nuts.
<Shielded of threaded type>
<Non-shielded of threaded type>
D
D
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
•The tightening torque should be as given below.
Mounting with set screw
<Shielded of threaded type>
•Tighten the set screw on the flat surface of the sensor
without applying excessive force. Make sure to use a set
screw with a cup-point end.
Model No.
Set screw tightening
position A (mm in)
Tightening
torque
GX-5M□
5 to 10 0.197 to 0.394
0.29 N·m
GX-8M□
8 to 22 0.315 to 0.866
0.29 N·m
<Non-threaded type and non-shielded of threaded type>
Set screw
(M4 or less)
Tightening
B (mm in) C (mm in)
torque
Model No.
GX-3S□
3
0.118
GX-4S□
5 to 10
0.197 to 0.394
3
0.118
0.58 N·m
GX-5S□
8 to 20
0.315 to 0.787
5
0.197
0.29 N·m
GX-8ML□
13 to 22
0.517 to 0.866
10
0.394
0.29 N·m
Model No.
GX-5M□
•To fasten GX-3S□ and GX-4S□, use a M3 or less set
screw and tighten it from a direction perpendicular to the
operation indicator.
Operation
indicator
GX-8ML□
Operation
indicator
Set screw
•When using the C bracket, place it on the sensor at a
distance of 3 mm 0.118 in or more from the sensor end.
C bracket
3 mm 0.118 in or more
•To fasten the non-shielded threaded type, tighten the set
screw on the flat surface of the sensor.
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
D (mm in)
Tightening torque
2 to 3 0.079 to 0.118
0.49 N·m
3 0.118 or more
1.47 N·m
3 to 11 0.118 to 0.433
1.47 N·m
11 0.433 or more
3.43 N·m
9 to 11 0.345 to 0.433
0.98 N·m
11 0.433 or more
3.43 N·m
Note: Mount such that the nuts do not protrude from the threaded portion.
•The root truncation of the threads with GX-8M□ and GX-8ML□ is shallow owing to strengthening of the
sensors against tightening.
When tapping holes on equipment to fix the sensors, the
prepared holes must be ø7.2 mm ø0.283 in or more.
Tapping holes
Sensor
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
0.58 N·m
Note: The protrusion should be kept C (mm in) or
more to avoid reduction of sensing range.
Operation
indicator
Mounting plate
Attached toothed lock washer
(2 pcs. attached for “-R” type only)
0.29 N·m
5 to 10
0.197 to 0.394
When using
the C bracket
C
Attached toothed
lock washer
Mounting plate
GX-8M□
A
Note: To fasten GX-5M□, use a M3 or less set screw.
B
818
Refer to General precautions.
Mounting
Set screw
(M4 or less)
(Note)
GX SERIES
Tap
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
Amplifierseparated
GX-F/H
GXL
GL
GX-U/GX-FU/
GX-N
GX
819
Cylindrical Compact Inductive Proximity Sensor
PRECAUTIONS FOR PROPER USE
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
Distance from surrounding metal
Influence of surrounding metal
•The surrounding metal will affect the sensing
performance. Keep the minimum distance specified in the
table below.
Background metal
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
E
SIMPLE
WIRE-SAVING
UNITS
STATIC
CONTROL
DEVICES
F
HUMAN
MACHINE
INTERFACES
G
Metal
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
UV
CURING
SYSTEMS
3 0.118
Iron
1
1
1
GX-5S□
4 0.157
0.65 approx.
0.83 approx.
0.7 approx.
GX-5M□
3 0.118
Stainless steel
(SUS304)
GX-8M□
4 0.157
Brass
0.36 approx.
0.61 approx.
0.4 approx.
GX-8ML□
8 0.315
Aluminum
0.30 approx.
0.58 approx.
0.35 approx.
H
Amplifier
Built-in
Amplifierseparated
GX-F/H
GXL
GL
GX-U/GX-FU/
GX-N
GX
Parallel mounting
J
Metal
Others
Model No.
F (mm in) G (mm in)
GX-3S□
ø12 ø0.472
3 0.118
GX-4S□
ø12 ø0.472
3 0.118
GX-5S□
ø15.4 ø0.606 5 0.197
GX-8ML□
ø30 ø1.181 10 0.394
•When two or more sensors are installed in parallel or face
to face, keep the minimum separation distance specified
below to avoid mutual interference.
Selection
Guide
GX-5S□
GX-8M□
GX-8ML□
3 0.118
Mutual interference
Face to face mounting
GX-5M□
GX-4S□
•Sensing range may decrease if the sensor is completely
embedded in metal. Especially for the non-threaded type
and the non-shielded type, keep the minimum distance
specified in the table below.
PLC /
TERMINALS
GX-3S□
GX-4S□
GX-3S□
Embedding of the sensor in metal
LASER
MARKERS
MACHINE
VISION
SYSTEMS
Correction coefficient
E (mm in)
ENDOSCOPE
FA
COMPONENTS
•The sensing range is specified for the standard sensing
object. With a non-ferrous metal, the sensing range is
obtained by multiplying with the correction coefficient
specified below. Further, the sensing range also changes
if the sensing object is smaller than the standard sensing
object or if the sensing object is plated.
Model No.
Model No.
INDUCTIVE
PROXIMITY
SENSORS
MEASUREMENT
SENSORS
Refer to General precautions.
Sensing range
•As metal around the sensor may affect the sensing
performance, pay attention to the following points.
PRESSURE /
FLOW
SENSORS
WIRE-SAVING
SYSTEMS
GX SERIES
Model No.
H (mm in) J (mm in)
GX-3S□
16 0.630 16 0.630
GX-4S□
16 0.630 16 0.630
GX-5S□
20 0.787 15 0.591
GX-5M□
10 0.394 10 0.394
GX-8M□
20 0.787 15 0.591
GX-8ML□
50 1.969 30 1.181
•Do not use during the initial transient time (10 ms) after
the power supply is switched on.
•Make sure that stress by forcible bend or pulling is not
applied directly to the sensor cable joint.
•GX-3S□, GX-4S□ and GX-5M□ do not incorporate
a short-circuit protection circuit at the output. Do not
connect them directly to a power supply or a capacitive
load.
Cylindrical Compact Inductive Proximity Sensor
DIMENSIONS (Unit: mm in)
Sensor
19
0.748
ø3.8
ø0.150
30
1.181
Sensor
4.4
0.173
Toothed lock
washer
(Internally toothed)
8
0.315
Sensor
3
0.118
7.4
0.291
MS-SS3-2
Flat part
ø5
ø0.197
3
0.118
ø6.4
ø0.252
ø3.5 ø0.138 cable,
3 m 9.843 ft long
6
0.236
STATIC
CONTROL
DEVICES
Sensor
12
0.472
3
0.118
Toothed lock washer
(Internally toothed)
24
0.945
Operation indicator (Red)
6
0.236
ø15
ø0.591
7.4
0.291
Flat part
M8 × 1
0.039 thread
MS-SS3
MS-SS5
ø3.5 ø0.138 cable,
3 m 9.843 ft long
2-ø3.5 ø0.138
mounting holes
(4.75)
(0.187)
C
14
0.551
Note: By using the C bracket, the applicable tightening force can be doubled.
Model No.
Symbol
A
A
B
B
4 0.157
4
0.157
8
0.315
16
0.630
Material: Nylon 66
4
0.157
D
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
Sensor mounting bracket for GX-3S□ (Accessory for GX-3S□)
Sensor mounting bracket for GX-5S□ (Accessory for GX-5S□)
t 0.45
t 0.018
ENDOSCOPE
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
ø5
ø0.197
M8 × 1 0.039 thread
C bracket for GX-3S□ (Accessory for GX-3S□)
SIMPLE
WIRE-SAVING
UNITS
MEASUREMENT
SENSORS
30
1.181
M5 × 0.5 0.020 thread
30
1.181
Operation indicator (Red)
SENSOR
OPTIONS
WIRE-SAVING
SYSTEMS
ø3.8
ø0.150
4
0.157
GX-8ML□
3
0.118
Toothed lock washer
(Internally toothed)
30
1.181
ø15
ø0.591
ø2.6 ø0.102 cable,
3 m 9.843 ft long
19
0.748
Flat part
12
0.472
Operation indicator (Red)
18
0.709
2
0.079
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
ø3.5 ø0.138 cable,
3 m 9.843 ft long
GX-8M□
LIGHT
CURTAINS
ø2.6 ø0.102 cable,
3 m 9.843 ft long
GX-5M□
Operation indicator (Red)
30
1.181
MICRO
PHOTOELECTRIC
SENSORS
PRESSURE /
FLOW
SENSORS
ø10
ø0.394
ø5.4
ø0.213
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Operation indicator (Red)
4
0.157
FIBER
SENSORS
AREA
SENSORS
ø4.4
ø0.173
ø2.6 ø0.102 cable,
3 m 9.843 ft long
Sensor
3
0.118
Sensor
19
0.748
GX-5S□
17.1
0.673
GX-4S□
Operation indicator (Red)
30
1.181
820
The CAD data in the dimensions can be downloaded from our website.
GX-3S□
4
0.157
GX SERIES
MS-SS3 MS-SS5
16 0.630
18 0.709
9 0.354
10 0.394
UV
CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
Amplifierseparated
C
6.3 0.248 8.3 0.327
GX-F/H
D
4.9 0.193 6.1 0.240
GXL
Applicable
model No.
GX-3S□
GX-5S□
GL
GX-U/GX-FU/
GX-N
GX