PFC SERIES
Power Factor Correction Chokes
Power Factor Correction Series
Features
- Chokes for CCM PFC operation
- Can be used in a wide range of sinusoidal
absorption rectifier circuits
- Mounting onto water-plate heatsinks
- Power rating : 4-10-20kW
- Inductance range : 80µH to 500µH
- Frequency range : 50-100kHz
- H class component for operation up to 180°C
- Very stable performances versus temperature
- No thermal aging effect
- Possibility of customized outputs
- UL94V-0 material
- RoHS compliant
Applications
- Automotive embedded battery chargers
- Industrial high power SMPS
Electrical specifications
Code
Input
Output
Power Freq.
Voltage Voltage
(kW) (kHz)
Vac (V) Vdc (V)
L0 (3)
±10%
(µH)
L MIN (4) at
Peak
Current
(µH)
DCR
MAX
(mΩ)
Current
Irms
(A)
PFC-001
230
385
4
67
310
> 80@27A
25
17
6
13
0,4
PFC-002
400
800
10
50
530
> 210@40A
60
25
10
52
1,1
PFC-003 (*)
400
800
20
50
2x 530
> 210@40A
2x 60
2x 25
10
2x 52
2,3
(*) Dedicated to interleaved PFC topology (double-choke with center-tap)
Notes
(1) All test data are referenced to 25°C ambient temperature
(2) Continuous operating temperature range must be within
-40°C/+150°C (ambient + self heating) under worst
case conditions ; exposure to 180°C peak is allowed according
to IEC85 H thermal index for all raw materials used
(3) Performances are subjected to change according to cooling
capability of the heatsink on which the component is fixed
It is suggested that the component be tested at system level to
verify its temperature after 60 minutes in the end application
Inductance values are measured at 10kHz/0.25V
Less than +/-5% variation on -40°C/+150°C temperature range
(4) See L vs. Idc curve beside
(5) Dielectric strength between windings and aluminum box is greater
than 2.5kV/50Hz/2sec
154
Ripple Losses
Weight
∆Ipp @100°C
(kg)
(A)
(W)
PFC SERIES
Typical performances versus temperature and frequency
Power Factor Correction Chokes
Power Factor Correction Series
155
PFC SERIES
Power Factor Correction Chokes
Power Factor Correction Series
Dimensions
PFC-001
PFC-002
156
PFC SERIES
Power Factor Correction Chokes
Power Factor Correction Series
Dimensions
PFC-003
Packaging
Antistatic trays with carton grids in carton box
157