Inductive sensors IWRM 12I9704/S14X Inductive distance measuring sensors dimension drawing 50 SW 17 35 M12 x 1 M12 x 1 general data photo mounting type quasi-flush measuring distance Sd 0 ... 4 mm resolution repeat accuracy < 0,001 mm (stat.) < 0,005 mm (dynam.) < 0,01 mm linearity error ± 160 µm temperature drift ± 4 % (Full Scale) approvals/certificates ATEX 2D electrical data response time (factory characteristic) < 2 ms voltage supply range +Vs 15 ... 27 VDC current consumption max. (no load) 20 mA output circuit current output output signal 4 ... 20 mA load resistance +Vs min. < 330 Ohm load resistance +Vs max. < 1000 Ohm Maximal zulässige Verlustleistung < 1,35 W short circuit protection yes reverse polarity protection yes connection diagram IWRM ~ ~ ~ BN (1) +VS WH/BK (2/4) output Z BU(3) 0V mechanical data brass nickel plated dimension 12 mm housing length 50 mm connection types connector M12 tightening torque max. 15 Nm installation drawing 5 cylindrical threaded housing material 1 ±0.1 type ambient conditions protection class IP 67 safe maximum values marking II 2D Ex tb IIIC T100°C Db IP6X operating temperature Ta -10 ... +50 °C IWRM 12I9704/S14X www.baumer.com linearity deviation (S = 0,5...4 mm) ± 4% (Full Scale) 24/5/2016 Inductive sensors IWRM 12I9704/S14X Inductive distance measuring sensors Safe maximum values EC type test certificate SEV 12 ATEX 0123 X Marking II 2D Ex tb IIIC T100°C Db IP6X Standards According to the declaration of conformity Operating temperature -10 ... +50 °C Storage temperature -10 ... +75°C Special conditions “X” • The device must be set up so that the device and the plug-in connector are completely mechanically protected from impact effects in accordance with EN 60079-0 Section 26.4.2 • The metal housing must be conductively connected to the plant's equipotential bonding system • The plug may only be connected or disconnected in a de-energized state and must be secured against tool-free isolation with the supplied fuse clip • Device and connection cable must be installed so that they are protected from UV light Approved Baumer connection cable Cable type PUR halogen-free black Cable outer diameter 4.40 mm Wire 3 x 0.34 mm2 Additional strain relief required > 100 N Installation torque for tightness 0.4 Nm UL- listed E315836 Straight connector ESG 34SH0200X ESG 34SH0300X ESG 34SH0500X ESG 34SH1000X ESG 34SH2000X 11099263 11099265 11099266 11099267 11099268 2m 3m 5m 10 m 20 m Angled connector ESW 33SH0200X ESW 33SH0500X ESW 33SH0600X ESW 33SH1000X ESW 33SH2000X 11099269 11099270 11099271 11099272 11099273 2m 5m 6m 10 m 20 m Other lengths on request IWRM 12I9704/S14X www.baumer.com 24/5/2016