Inductive sensors
IWRM 12I9704/S14X
Inductive distance measuring
sensors
dimension drawing
50
SW 17
35
M12 x 1
M12 x 1
general data
photo
mounting type
quasi-flush
measuring distance Sd
0 ... 4 mm
resolution
repeat accuracy
< 0,001 mm (stat.)
< 0,005 mm (dynam.)
< 0,01 mm
linearity error
± 160 µm
temperature drift
± 4 % (Full Scale)
approvals/certificates
ATEX 2D
electrical data
response time (factory characteristic)
< 2 ms
voltage supply range +Vs
15 ... 27 VDC
current consumption max. (no load)
20 mA
output circuit
current output
output signal
4 ... 20 mA
load resistance +Vs min.
< 330 Ohm
load resistance +Vs max.
< 1000 Ohm
Maximal zulässige Verlustleistung
< 1,35 W
short circuit protection
yes
reverse polarity protection
yes
connection diagram
IWRM
~
~
~
BN (1)
+VS
WH/BK (2/4)
output
Z
BU(3)
0V
mechanical data
brass nickel plated
dimension
12 mm
housing length
50 mm
connection types
connector M12
tightening torque max.
15 Nm
installation drawing
5
cylindrical threaded
housing material
1 ±0.1
type
ambient conditions
protection class
IP 67
safe maximum values
marking
II 2D Ex tb IIIC T100°C Db IP6X
operating temperature Ta
-10 ... +50 °C
IWRM 12I9704/S14X
www.baumer.com
linearity deviation (S = 0,5...4 mm) ± 4%
(Full Scale)
24/5/2016
Inductive sensors
IWRM 12I9704/S14X
Inductive distance measuring
sensors
Safe maximum values
EC type test certificate
SEV 12 ATEX 0123 X
Marking
II 2D Ex tb IIIC T100°C Db IP6X
Standards
According to the declaration of
conformity
Operating temperature
-10 ... +50 °C
Storage temperature
-10 ... +75°C
Special conditions “X”
• The device must be set up so that the device and the plug-in connector
are completely mechanically protected from impact effects in accordance
with EN 60079-0 Section 26.4.2
• The metal housing must be conductively connected to the plant's
equipotential bonding system
• The plug may only be connected or disconnected in a de-energized state
and must be secured against tool-free isolation with the supplied fuse clip
• Device and connection cable must be installed so that they are protected
from UV light
Approved Baumer connection cable
Cable type
PUR halogen-free black
Cable outer diameter
4.40 mm
Wire
3 x 0.34 mm2
Additional strain relief required
> 100 N
Installation torque for tightness
0.4 Nm
UL- listed
E315836
Straight connector
ESG 34SH0200X
ESG 34SH0300X
ESG 34SH0500X
ESG 34SH1000X
ESG 34SH2000X
11099263
11099265
11099266
11099267
11099268
2m
3m
5m
10 m
20 m
Angled connector
ESW 33SH0200X
ESW 33SH0500X
ESW 33SH0600X
ESW 33SH1000X
ESW 33SH2000X
11099269
11099270
11099271
11099272
11099273
2m
5m
6m
10 m
20 m
Other lengths on request
IWRM 12I9704/S14X
www.baumer.com