UXA 0204, UXB 0207, UXE 0414 Datasheet

UXA 0204, UXB 0207, UXE 0414
www.vishay.com
Vishay Beyschlag
Ultra Precision Metal Film Leaded Resistors
FEATURES
• Exceptional low TCR: ± 2 ppm/K to ± 10 ppm/K
• Super tight tolerance: ± 0.01 % to ± 0.25 %
• Exceptional overall stability: class 0.02
• Wide resistance range: 22  to 1 M
• Material categorization: for definitions of compliance
please see www.vishay.com/doc?99912
DESCRIPTION
APPLICATIONS
UXA 0204, UXB 0207, and UXE 0414 high precision leaded
thin film resistors combine the proven reliability of the
professional products with an exceptional level of precision
and stability. Therefore they are perfectly suited for
applications in the fields of precision test and measuring
equipment and particularly for the design of calibration
references and standards.
• Precision test and measuring equipment
• Design of calibration references and standards
TECHNICAL SPECIFICATIONS
DESCRIPTION
UXA 0204
UXB 0207
UXE 0414
0204
0207
0414
A
B
D
22  to 221 k
10  to 1 M
22  to 511 k
± 0.25 %; ± 0.1 %;
± 0.05 %; ± 0.01 %
± 0.25 %; ± 0.1 %;
± 0.05 %; ± 0.01 %
± 0.1 %; ± 0.05 %
± 10 ppm/K; ± 5 ppm/K;
± 2 ppm/K
± 10 ppm/K; ± 5 ppm/K;
± 2 ppm/K
± 10 ppm/K; ± 5 ppm/K
P85
0.05 W
0.125 W
0.25 W
P70
0.1 W
0.25 W
0.5 W
200 V
250 V
300 V
DIN size
CECC size
Resistance range
Resistance tolerance
Temperature coefficient
Rated dissipation:
Operating voltage, Umax. AC/DC
Operating temperature range (1)
-20 °C to 125 °C
Peak permissible film temperature (1)
125 °C
Insulation voltage:
1 min.; Uins
300 V
500 V
800 V
Continuous
75 V
75 V
75 V
100  to 100 k
100  to 250 k
100  to 100 k
Max. resistance change at P70 for resistance
range, R/R max., after:
2000 h
Max. resistance change at P85 for resistance
range, R/R max., after:
1000 h
Failure rate: FITobserved
Revision: 07-Mar-16
 0.05 %
 0.05 %
 0.05 %
100  to 100 k
100  to 250 k
100  to 100 k
 0.02 %
 0.02 %
 0.02 %
8000 h
 0.04 %
 0.04 %
 0.04 %
225 000 h
 0.12 %
 0.12 %
 0.12 %
 0.1 x 10-9/h
Document Number: 28726
1
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
UXA 0204, UXB 0207, UXE 0414
www.vishay.com
Vishay Beyschlag
TEMPERATURE COEFFICIENT AND RESISTANCE RANGE
TYPE
TCR
± 10 ppm/K
UXA 0204
± 5 ppm/K
± 2 ppm/K (3)
± 10 ppm/K
UXB 0207
± 5 ppm/K
± 2 ppm/K (3)
± 10 ppm/K
UXE 0414
± 5 ppm/K
TOLERANCE
RESISTANCE (1)(2)(3)
E-SERIES
± 0.25 %
22  to 221 k
E192
± 0.1 %
43  to 221 k
E192
± 0.05 %
100  to 180 k
E192
± 0.01 %
200  to 150 k
E192
± 0.25 %
47  to 150 k
E192
± 0.1 %
47  to 150 k
E192
± 0.05 %
100  to 150 k
E192
± 0.01 %
200  to 150 k
E192
± 0.25 %
100  to 100 k
E192
± 0.1 %
100  to 100 k
E192
± 0.05 %
150  to 100 k
E192
± 0.01 %
200  to 100 k
E192
± 0.25 %
10  to 1 M
E192
± 0.1 %
10  to 1 M
E192
± 0.05 %
24  to 301 k
E192
± 0.01 %
24  to 301 k
E192
± 0.25 %
10  to 1 M
E192
± 0.1 %
10  to 1 M
E192
± 0.05 %
24  to 221 k
E192
± 0.01 %
24  to 221 k
E192
± 0.25 %
100  to 150 k
E192
± 0.1 %
100  to 150 k
E192
± 0.05 %
150  to 150 k
E192
± 0.01 %
200  to 150 k
E192
± 0.1 %
22  to 511 k
E192
± 0.05 %
100  to 301 k
E192
± 0.1 %
47  to 301 k
E192
± 0.05 %
100  to 301 k
E192
Notes
(1) Resistance values to be selected from the E192 series, for other values please contact the factory.
(2) TCR 10 and TCR 05 are specified over the temperature range from -20 °C to +85 °C.
(3) TCR 02 is specified over the temperature range 0 °C to +60 °C.
Revision: 07-Mar-16
Document Number: 28726
2
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
UXA 0204, UXB 0207, UXE 0414
www.vishay.com
Vishay Beyschlag
PART NUMBER AND PRODUCT DESCRIPTION
PART NUMBER: UXB02070F1001AC100
U
X
B
0
2
0
7
0
F
1
0
0
1
A
C
1
0
0
TYPE / SIZE
VARIANT
TCR
VALUE
TOLERANCE
PACKAGING
SPECIAL
UXA0204
UXB0207
UXE0414
0 = neutral
H = ± 2 ppm/K
G = ± 5 ppm/K
F = ± 10 ppm/K
3 digit value
1 digit multiplier
Multiplier
9 = *10-1
0 = *100
1 = *101
2 = *102
3 = *103
4 = *104
T = ± 0.01 %
A = ± 0.05 %
B = ± 0.1 %
C = ± 0.25 %
C1
CU
R1
R2
RP
Up to 2 digits
00 = standard
PRODUCT DESCRIPTION: UXB 0207-10 0.05 % C1 1K0
UXB
0207
10
0.05 %
C1
1K0
TYPE
SIZE
TCR
TOLERANCE
PACKAGING (1)
RESISTANCE
VALUE
UXA
UXB
UXE
0204
0207
0414
± 2 ppm/K
± 5 ppm/K
± 10 ppm/K
± 0.01 %
± 0.05 %
± 0.1 %
± 0.25 %
C1
CU
R1
R2
RP
1K0 = 1.0 
47K = 47 k
50R5 = 50.5 
Note
• The part number is shown to facilitate the introduction of a unified part numbering system.
PACKAGING
TYPE / SIZE
UXA 0204
UXB 0207
UXE 0414
CODE
QUANTITY
PACKAGING STYLE
WIDTH
PITCH
DIMENSIONS
CU
100
C1
1000
Taped acc. to IEC 60286-1
fan-folded in a box
53 mm
5 mm
74 mm x 42 mm x 184 mm
Taped acc. to IEC 60286-1
fan-folded in a box
53 mm
5 mm
75 mm x 40 mm x 187 mm
Taped acc. to IEC 60286-1
on a reel
53 mm
5 mm
Taped acc. to IEC 60286-1
fan-folded in a box
53 mm
5 mm
47 mm x 84 mm x 374 mm
Taped acc. to IEC 60286-1
on a reel
53 mm
5 mm
315 mm x 80 mm x 90 mm
CU
100
C1
1000
R1
1000
RP
5000
CU
100
C1
1000
R2
2500
315 mm x 70 mm x 80 mm
315 mm x 76 mm x 86 mm
SCRIPT MARKING - Printed resistance value and letter coding for TCR and tolerance
RESISTANCE VALUE
Clear text code for value
Revision: 07-Mar-16
TOL. (%)
LETTER CODE
TCR (ppm/K)
LETTER CODE
± 0.25
C
± 10
B
± 0.1
B
±5
A
± 0.05
A
±2
T
± 0.01
T
-
-
Document Number: 28726
3
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
UXA 0204, UXB 0207, UXE 0414
www.vishay.com
DESCRIPTION
Production is strictly controlled and follows an extensive
set of instructions established for reproducibility. A
homogeneous film of metal alloy is deposited on a high
grade ceramic body (85 % Al2O3) and conditioned to
achieve the desired temperature coefficient. Nickel plated
steel termination caps are firmly pressed on the metallized
rods. Special laser devices are used repeatedly to achieve
the target value by slowly and smoothly cutting a helical
groove in the resistive layer without damaging the ceramics.
A further conditioning is applied in order to stabilise the
trimming result. Connecting wires of electrolytic copper
plated with pure tin are welded to the termination caps.
The resistors are covered by protective coating designed
for electrical, mechanical and climatic protection. The
terminations receive a final pure tin on nickel plating. Script
marking designates the resistance value plus coded TCR
and tolerance.
The result of the determined production is verified by an
accelerated aging (burn-in) and extensive testing procedure
performed on 100 % of the individual resistors. Only
accepted products are stuck directly on the adhesive tapes
in accordance with IEC 60286-1.
ASSEMBLY
The resistors are suitable for processing on automatic
insertion equipment and cutting and bending machines.
Excellent solderability is proven, even after extended
storage. They are suitable for automatic soldering using
wave or dipping. The encapsulation is resistant to all
cleaning solvents commonly used in the electronics
industry, including alcohols, esters and aqueous solutions.
The suitability of conformal coatings, if applied, shall be
qualified by appropriate means to ensure the long-term
stability of the whole system. The resistors are completely
lead (Pb)-free, the pure tin plating provides compatibility
with lead (Pb)-free and lead-containing soldering processes.
The immunity of the plating against tin whisker growth has
been proven under extensive testing.
Vishay Beyschlag
MATERIALS
Vishay acknowledges the following systems for the
regulation of hazardous substances:
• IEC 62474, Material Declaration for Products of and for the
Electrotechnical Industry, with the list of declarable
substances given therein (1)
• The Global Automotive Declarable Substance List
(GADSL) (2)
• The REACH regulation (1907/2006/EC) and the related list
of substances with very high concern (SVHC) (3) for its
supply chain
The products do not contain any of the banned substances
as per IEC 62474, GADSL, or the SVHC list, see
www.vishay.com/how/leadfree.
Hence the products fully comply with the following
directives:
• 2000/53/EC End-of-Life Vehicle Directive (ELV) and
Annex II (ELV II)
• 2011/65/EU Restriction of the Use of Hazardous
Substances
Directive
(RoHS)
with
amendment
2015/863/EU
• 2012/19/EU Waste Electrical and Electronic Equipment
Directive (WEEE)
Vishay pursues the elimination of conflict minerals from its
supply chain, see the Conflict Minerals Policy at
www.vishay.com/doc?49037.
APPROVALS
Where applicable, the resistors are tested in accordance to
EN 60115-1 and EN 140100.
Vishay
Beyschlag
has
achieved
“Approval
of
Manufacturer” in accordance with IEC QC 001002-3,
clause 2. The release certificate for “Technology Approval
Schedule” in accordance with CECC 240001 based on
IEC QC 001002-3, clause 6 is granted for the Vishay
Beyschlag manufacturing process.

Notes
(1) The IEC 62474 list of declarable substances is maintained in a dedicated database, which is available at http://std.iec.ch/iec62474.
(2) The Global Automotive Declarable Substance List (GADSL) is maintained by the American Chemistry Council and available at
www.gadsl.org.
(3) The SVHC list is maintained by the European Chemical Agency (ECHA) and available at http://echa.europa.eu/candidate-list-table.
Revision: 07-Mar-16
Document Number: 28726
4
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
UXA 0204, UXB 0207, UXE 0414
www.vishay.com
Vishay Beyschlag
Power Dissipation P
FUNCTIONAL DESCRIPTION
UXE 0414
UXB 0207
UXA 0204
0.2
W
0.1
0
50
0
- 50
85
100
150
°C
Ambient Temperature ϑ amb
Temperature Rise Tr
Derating - Standard Operation
UXA 0204
UXB 0207
UXE 0414
60
K
40
20
0
0
0.1
0.2
0.3
0.4
W
0.5
Load P
Rise of the surface temperature.
Current Noise A 1
Temperature Rise
1
uV/V
0.1
UXA 0204
UXB 0207
UXE 0401
0.01
1 kΩ
10 kΩ
100 kΩ
1 MΩ
Resistance Value R
Current Noise A1 in accordance with IEC 60195
Revision: 07-Mar-16
Document Number: 28726
5
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
UXA 0204, UXB 0207, UXE 0414
www.vishay.com
Vishay Beyschlag
TESTS AND REQUIREMENTS
Essentially all tests are carried out in accordance with the
following specifications:
Unless otherwise specified the following values apply:
• EN 60115-1, Generic specification (includes tests)
• Relative humidity: 45 % to 75 %
The Test Procedures and Requirements table contains only
the most important tests. For the full test schedule refer to
the documents listed above. The testing also covers most of
the requirements specified by EIA/IS-703 and JIS-C-5202.
• Air pressure: 86 kPa to 106 kPa (860 mbar to 1060 mbar).
The tests are carried out in accordance with IEC 60068-2-xx
test method and under standard atmospheric conditions in
accordance with IEC 60068-1, 5.3. Climatic category
-20 °C / +125 °C / 56 days (rated temperature range: Lower
category temperature, upper category temperature; damp
heat, long term, 56 days) is valid.
• Temperature: 15 C to 35 C
For testing the components are mounted on a test board in
accordance with IEC 60115-1, 4.31 unless otherwise
specified.
In the Test Procedures and Requirements table only the
tests and requirements are listed with reference to the
relevant clauses of IEC 60115-1 and IEC 60068-2-xx test
method. A short description of the test procedure is also
given.
TEST PROCEDURES AND REQUIREMENTS
PROCEDURE
REQUIREMENTS PERMISSIBLE CHANGE (R)
Stability for product types:
IEC
60115-1
CLAUSE
IEC
60068-2
TEST
METHOD
UXA 0204
100  to 100 k
22  to < 100 
> 100 k to 221 k
-
UXB 0207
100  to 250 k
40.2  to < 100 
> 250 k to 301 k
10  to < 40.2 
> 301 k to 1 M
UXE 0414
100  to 100 k
22  to < 100 
> 100 k to 511 k
-
TEST
4.5
-
Resistance
-
± 0.25 %; ± 0.1 %; ± 0.05 %; ± 0.01 %
4.7
-
Voltage proof
URMS = Uins; 60 s
No flashover or breakdown
At (20 / -20 / 20) °C and
(20 / 85 / 20) °C
10 ppm/K; 5 ppm/K
-
Temperature
coefficient
At (20 / 0 / 20) °C and
(20 / 60 / 20) °C
2 ppm/K
4.8
4.13
-
Short time
overload
Room temperature;
U = 2.5 x P 70 x R or
U = 2 x Umax.; 5 s
± (0.01 % R + 0.01 ) ± (0.01 % R + 0.01 ) ± (0.02 % R + 0.01 )
4.16
21 (Ua1)
21 (Ub)
21 (Uc)
Robustness
of terminations
Tensile, bending,
and torsion
± (0.01 % R + 0.01 ) ± (0.01 % R + 0.01 ) ± (0.02 % R + 0.01 )
at +235 °C; 2 s;
solder bath method;
SnPb40
4.17
20 (Ta)
Solderability
Good tinning (> 95 % covered); no damage
at +245 °C; 3 s;
solder bath method;
SnAg3Cu0.5
4.18.2
20 (Tb)
Resistance to
soldering heat
Unmounted components;
(260 ± 5) °C; (10 ± 1) s
± (0.01 % R + 0.01 ) ± (0.01 % R + 0.01 ) ± (0.02 % R + 0.01 )
4.19
14 (Na)
Rapid change
of temperature
30 min at -55 °C
30 min at +125 °C
5 cycles
± (0.01 % R + 0.01 ) ± (0.01 % R + 0.01 ) ± (0.02 % R + 0.01 )
4.22
6 (B4)
Vibration
10 sweep cycles per
direction; 10 Hz to 2000 Hz
1.5 mm or 200 m/s2
± (0.01 % R + 0.01 ) ± (0.01 % R + 0.01 ) ± (0.02 % R + 0.01 )
Revision: 07-Mar-16
Document Number: 28726
6
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
UXA 0204, UXB 0207, UXE 0414
www.vishay.com
Vishay Beyschlag
TEST PROCEDURES AND REQUIREMENTS
PROCEDURE
REQUIREMENTS PERMISSIBLE CHANGE (R)
Stability for product types:
IEC
60115-1
CLAUSE
IEC
60068-2
TEST
METHOD
100  to 100 k
22  to < 100 
> 100 k to 221 k
-
UXB 0207
100  to 250 k
40.2  to < 100 
> 250 k to 301 k
10  to < 40.2 
> 301 k to 1 M
UXE 0414
100  to 100 k
22  to < 100 
> 100 k to 511 k
-
Climatic
sequence:
4.23
4.23.2
UXA 0204
TEST
2 (Ba)
Dry heat
125 °C; 16 h
4.23.3
30 (Db)
Damp heat,
cyclic
55 °C; 24 h;
90 % to 100 % RH; 1 cycle
4.23.4
1 (Aa)
Cold
-55 °C; 2 h
4.23.5
13 (M)
Low air
pressure
8.5 kPa; 2 h;
15 °C to 35 °C
4.23.6
30 (Db)
Damp heat,
cyclic
55 °C; 5 days;
95 % to 100 % RH; 5 cycles
DC load
apply rated power for 1 min
78 (Cab)
Damp heat,
steady state
(40 ± 2) °C; 56 days;
(93 ± 3) % RH
4.23.7
4.24
4.25.1
4.25.3
4.29
-
Endurance
(at 70 °C)
± (0.04 % R + 0.01 ); ± (0.05 % R + 0.01 ); ± (0.06 % R + 0.01 );
no visible damage
no visible damage
no visible damage
± (0.04 % R + 0.01 ) ± (0.05 % R + 0.01 ) ± (0.06 % R + 0.01 )
U = P 70 x R or
U = Umax.;
1.5 h on; 0.5 h off
70 °C; 2000 h
± (0.05 % R + 0.01 ) ± (0.05 % R + 0.01 ) ± (0.05 % R + 0.01 )
85 °C; 1000 h
± (0.02 % R + 0.01 ) ± (0.03 % R + 0.01 ) ± (0.04 % R + 0.01 )
85 °C; 8000 h
± (0.04 % R + 0.01 ) ± (0.06 % R + 0.01 ) ± (0.08 % R + 0.01 )
-
Endurance
at upper
category
temperature
125 °C; 1000 h
± (0.04 % R + 0.01 ) ± (0.06 % R + 0.01 ) ± (0.08 % R + 0.01 )
45 (XA)
Component
solvent
resistance
Isopropyl alcohol (used in
industrial application)
+23 °C; toothbrush method
Marking legible; no visible damage
DIMENSIONS
D
d
L
I
M
DIMENSIONS - Leaded resistor types, mass, and relevant physical dimensions
Dmax.
(mm)
Lmax.
(mm)
dnom.
(mm)
Imin.
(mm)
Mmin.
(mm)
MASS
(mg)
UXA 0204
1.6
3.6
0.5
29.0
5.0
125
UXB 0207
2.5
6.3
0.6
28.0
7.5
220
UXE 0414
4.0
11.9
0.8
31.0
15.0
750
TYPE
Revision: 07-Mar-16
Document Number: 28726
7
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
UXA 0204, UXB 0207, UXE 0414
www.vishay.com
Vishay Beyschlag
12NC INFORMATION FOR HISTORICAL CODING REFERENCE
• The resistors have a 12-digit part number starting with
2312.
• The subsequent 4 digits indicate the resistor type,
specification and packaging; see the 12NC Part Number
table.
• The remaining 4 digits indicate the resistance value:
- The first 3 digits indicate the resistance value.
- The last digit indicates the resistance decade in
accordance with the 12NC Indicating Resistance
Decade table.
Last Digit of 12NC Indicating Resistance Decade
RESISTANCE DECADE
10  to 99.9 
100  to 999 
1 k to 9.99 k
10 k to 99.9 k
100 k to 999 k
LAST DIGIT
9
1
2
3
4
12NC Example
The part number of a UXA 0204 resistor, value 47 k and
TCR 10 with ± 0.1 % tolerance, supplied on bandolier in a
box of 1000 units is: 2312 662 34703.
12NC PART NUMBER - Resistor type and packaging
DESCRIPTION
TYPE
TCR
± 10 ppm/K
TOL.
± 0.25 %
± 0.1 %
± 0.05 %
± 0.01 %
(1)
UXA 0204
± 5 ppm/K
± 0.25 %
± 0.1 %
± 0.05 %
± 0.01 %
(1)
± 2 ppm/K
± 0.25 %
± 0.1 %
± 0.05 %
± 0.01 %
(1)
± 10 ppm/K
± 0.25 %
± 0.1 %
± 0.05 %
± 0.01 %
(1)
UXB 0207
± 5 ppm/K
± 0.25 %
± 0.1 %
± 0.05 %
± 0.01 %
(1)
± 2 ppm/K
± 0.25 %
± 0.1 %
± 0.05 %
± 0.01 %
(1)
± 10 ppm/K
± 0.1 %
± 0.05 %
(1)
UXE 0414
± 5 ppm/K
± 0.1 %
± 0.05 %
(1)
BANDOLIER
IN BOX
CU 100 units
562 2....
562 3....
562 4....
562 7....
562 91...
563 2....
563 3....
563 4....
563 7....
563 91...
564 2....
564 3....
564 4....
564 7....
564 91...
572 2....
572 3....
572 4....
572 7....
572 91...
573 2....
573 3....
573 4....
573 7....
573 91...
574 2....
574 3....
574 4....
574 7....
574 91...
592 3....
592 4....
592 91...
593 3....
593 4....
593 91...
BANDOLIER
IN BOX
C1 1000 units
662 2....
662 3....
662 4....
662 7....
662 91...
663 2....
663 3....
663 4....
663 7....
663 91...
664 2....
664 3....
664 4....
664 7....
664 91...
672 2....
672 3....
672 4....
672 7....
672 91...
673 2....
673 3....
673 4....
673 7....
673 91....
674 2....
674 3....
674 4....
674 7....
674 91...
692 3....
692 4....
692 91...
693 3....
693 4....
693 91...
2312 ... .....
BANDOLIER
ON REEL
R1 1000 units
462 2....
462 3....
462 4....
462 7....
462 91...
463 2....
463 3....
463 4....
463 7....
463 91...
464 2....
464 3....
464 4....
464 7....
464 91...
472 2....
472 3....
472 4....
472 7....
472 91...
473 2....
473 3....
473 4....
473 7....
473 91...
474 2....
474 3....
474 4....
474 7....
474 91...
-
BANDOLIER
ON REEL
R2 2500 units
597 3....
597 4....
597 91...
598 3....
598 4....
598 91...
BANDOLIER
ON REEL
RP 5000 units
577 2....
577 3....
577 4....
577 7....
577 91...
578 2....
578 3....
578 4....
578 7....
578 91...
579 2....
579 3....
579 4....
579 7....
579 91...
-
Note
(1) Readable 12NC coding of resistance values is restricted to values with three significant digits. For resistance values with more than three
significant digits, a non readable sequential number will be issued by the factory for each requested combination of resistance value and tolerance.
Revision: 07-Mar-16
Document Number: 28726
8
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free
requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference
to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21
conform to JEDEC JS709A standards.
Revision: 02-Oct-12
1
Document Number: 91000