data sheet - family

Inductive sensors
IWFM 18
Inductive distance measuring
sensors
sample drawing
18
30
7
7
20
3,5
7
10
M8 x 1
12
general data
sample picture
mounting type
flush
measuring distance Sd
0 ... 4 mm
voltage - / current output
linearity error
± 160 µm
temperature drift
± 4 % (Full Scale)
voltage output
special type
linearized
linearity error
± 16 µm
temperature drift
± 5 % (Full Scale)
electrical data
voltage supply range +Vs
15 ... 30 VDC
short circuit protection
yes
reverse polarity protection
yes
voltage - / current output
current consumption max. (no load)
40 mA
output signal
0 ... 10 V / 4 ... 20 mA
load resistance
> 1000 Ohm (Uout ) / 330 ... 1000 Ohm
(Iout)
< 7,2 VDC (Iout)
voltage drop Vd
voltage output
current consumption max. (no load)
20 mA
output signal
0 ... 10 VDC
mechanical data
type
rectangular
housing material
brass nickel plated
dimension
18 mm
housing length
30 mm
connection types
connector M8
ambient conditions
operating temperature
-10 ... +70 °C
protection class
IP 67
1
www.baumer.com
24/5/2016
Inductive sensors
IWFM 18
Inductive distance measuring
sensors
order reference
resolution
repeat
accuracy
output circuit
response
time (factory
characteristic)
temperature
drift
linearity
error
special
type
IWFM 18L9504/S35A
< 0,005 mm
< 0,01 mm
voltage - /
current output
< 2 ms
± 4 % (Full
Scale)
± 160 µm
-
IWFM 18L9505/S35A
< 0,001 mm
< 0,005 mm
voltage - /
current output
< 30 ms
± 4 % (Full
Scale)
± 160 µm
-
IWFM 18U7504/S35A
< 0,005 mm
< 0,01 mm
voltage output
< 2,5 ms
± 5 % (Full
Scale)
± 16 µm
linearized
2
www.baumer.com