Photoelectric sensors OM70-X0150.HI0720.VI OM70-11155463 Distance sensors dimension drawing 26 4,3 5 14 7 9 64 50 74 85 9 LED 4,5 2 19 M12 x 1 55 * emitter axis general data photo version MESAX 70 multi-spot measuring distance Sd 100 ... 150 mm measuring range (width) 48 ... 72 mm adjustment Touch Display, RS485 power on indication LED green resolution 2 ... 4 µm 1) 2) 4) 5) linearity error ± 30 ... ± 90 µm 1) 2) 4) light source pulsed red laser diode wave length 656 nm laser class 1 beam type multi-spot temperature drift ± 0,04 % Sde/K 1) 2) 4) electrical data connection diagram response time / release time 3,5 ms 2) 3) measuring frequency 570 Hz 2) 3) voltage supply range +Vs 15 ... 28 VDC current consumption max. (no load) 120 mA output circuit analog and RS 485 baud rate 115200, adjustable output signal 4 ... 20 mA / 0 ... 10 VDC output current < 100 mA short circuit protection yes reverse polarity protection yes, Vs to GND GN (3) Z Z YE (4) mechanical data RS 485 GY(5) WH (1) pushPK (6) pull RD (8) BU (7) Z Z +Vs analog out alarm Rx/TxRx/Tx+ sync in 0V laser warning CLASS 1 LASER PRODUCT width / diameter 26 mm height / length 74 mm depth 55 mm type rectangular, front view housing material aluminum front (optics) glass connection types connector M12 8 pin OM70-X0150.HI0720.VI BN (2) www.baumer.com Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to laser notice No. 50, dated June 24, 2007 3/2/2016 Photoelectric sensors OM70-X0150.HI0720.VI OM70-11155463 Distance sensors ambient conditions ambient light immunity < 35 kLux operating temperature -10 ... +50 °C protection class IP 67 storage temperature -25 ... +75 °C vibration (sinusoidal) IEC 60068-2-6:2008 1.5 mm p-p at f = 10 - 57 Hz, 10 cycles per axis 10 g at f = 58 - 2000 Hz, 10 cycles per axis IEC 60068-2-27:2009 50 g / 11 ms resp. 100 g / 6 ms, 10 jolts per axis and direction 100 g / 2 ms, 5000 jolts per axis and direction shock (semi-sinusoidal) 1) Measurement with Baumer standardized measuring equipment and targets depending on measuring distance Sd 2) Measurement on 90% remission (white) 3) Measurement with reduced Field of View (start of measurement range 140 mm, end of measurement range 150 mm) 4) Measurement with measuring type average 5) Measurement with filtering OM70-X0150.HI0720.VI www.baumer.com 3/2/2016