GER & GEH Medium Voltage Replacement Circuit Breakers ANSI 4.76/8.25/15kV at 250–1000 MVA, 1200-3000 Amperes Replacement breakers provide a costeffective way to upgrade your system capabilities while saving you from costly maintenance and lost productivity while preserving your investment in existing cubicles and cables. 5-GER (Replacement for GE Magneblast AM) Why Siemens? Siemens Offers the Best Vacuum Circuit Breaker in the Industry. Siemens provides the experience your company needs to successfully extend the life of your equipment. Our circuit breakers are manufactured using the same fixtures as the original General Electric breakers. Why Replacement Breakers? Increased Reliability and Performance Reduced Operating and Maintenance Expenditures Reduced Downtime, Minimal Changeover Time During Upgrade Preserved Investment in Existing Cubicles Improved Employee and Environmental Safety Superior Performance, Longer Service Life 10,000 full load operation, 10-year maintenance cycle on replacement circuit breakers with 3AH operator Standard Operator on All Siemens Replacement, Medium Voltage Distribution, and Outdoor Vacuum Circuit Breakers Reduced part count and inventory Minimized maintenance training required Extensive Replacement Breaker Experience – 750+ projects since 1983 Over 300,0000 3AF/H series circuit breakers in service worldwide Nuclear 1E Rated (350+ breakers) Design, Production Testing per ANSI, IEEE Full Range of Service Capabilities by Skilled Factory-Trained Engineers 3AH Operator Features: 5-GEH (Replacement for GE Magneblast AMH) Power Transmission & Distribution Spring charge motor mechanism lifetime lubricated gear box Operating linkage machine parts vs. stamped metal Change-out of components easily accessible Vacuum contact erosion indication easily verifiable Siemens Type GER & GEH Medium Voltage Vacuum Circuit Breakers For General Electric AM & AMH The following circuit breakers are available as pre-engineered designs. Replacement Circuit Breaker Nominal Voltage Class Nominal 3Phase MVA Maximum Class Voltage E Voltage Range Factor Full Wave Continuous Short Circuit Close and Interrupting Withstand Current Current Latch Time Test Voltage (60 Hz) (at max. kV) Capability K I 1.6 x KI kA rms Nominal Weights kV MVA kV rms Cycles kV Peak Amperes kA rms lbs. 5 GER-250 4.16 250 4.76 1.24 5 60 1200, 2000 29 58 750 5 GER-350 4.16 350 4.76 1.19 5 60 1200, 2000 41 78 1250 5 GER-350 4.16 350 4.76 1.19 5 60 3000 78 2450 7 GER-500 7.2 500 8.25 1.25 5 95 1200, 2000 33 66, 77 1500 15 GER-500 13.8 500 15.0 1.3 5 95 1200, 2000 18 37, 58 1500 15 GER-750 13.8 750 15.0 1.3 5 95 1200, 2000 28 58, 77 1500 15 GER-1000 13.8 1000 15.0 1.3 5 95 1200, 2000 37 77 1560 15 GER-1000 5 GEH-250 13.8 4.16 1000 250 15.0 4.76 1.3 1.24 5 5 95 60 3000 37 1200, 2000 29 77 58 1730 675 41 Dimensions (Inches) 250 1200/2000 5 GER350 1200/2000 250 1200/3000 7/15 GER500/750 1200/2000 15 GER1000 1000 1200/2000 3000 A 40.25 52.50 52.50 52.50 67.00 67.00 15 GEH250 1200/2000 55.88 B 22.00 22.00 22.00 22.00 32.00 36.25 23.44 C 6.00 6.00 9.13 9.13 9.75 11.00 8.50 D 8.50 8.50 8.50 8.50 8.50 10.88 26.50 E 22.25 36.25 36.25 36.25 49.00 49.00 40.00 Sample Dimensional Diagram - GER Contact Us To find out more about Siemens replacement breakers, please contact your local Siemens representative or (800) 347-6659 regarding your site specific application. © 2007 Siemens Power Transmission & Distribution, Inc. All rights reserved. E 5001-U610-A137-X-US00 Subject to change without notice. Sample Dimensional Diagram - GEH Siemens Power Transmission & Distribution, Inc. Service Solutions Division 7000 Siemens Road Wendell, NC 27591 www.usa.siemens.com/energy All statements, technical information and recommendations contained herein are based on information and tests we believe to be reliable. The accuracy or completeness hereof is not guaranteed. Since conditions of use are outside our control, the user should determine the suitability of the product for its intended use and assumes all risk and liability whatsoever in connection herewith.