KPT/KPSE/KPTC Catalog

KPT / KPSE / KPTC Connectors
In Accordance with VG95328
ITT
Corporation
ITT is a diversified leading manufacturer of highly engineered critical
components and customized technology solutions for the energy,
transportation and industrial markets. Building on its heritage of innovation,
ITT partners with its customers to deliver enduring solutions to the key
industries that underpin our modern way of life. Founded in 1920, ITT is
headquartered in White Plains, N. Y., with employees in more than 35
countries and sales in a total of approximately 125 countries. The company
generated 2014 revenues of $ 2.7 billion. For more information, visit
www.itt.com.
Our connector portfolio remains the most extensive in the industry, offering a reliable and cost effective
range of interconnect solutions with the brands of Cannon, VEAM and BIW Connector Systems.
Continuous investment in technology and research & development have enabled ITT to provide new,
innovative products and solutions to markets including:
2
www.ittcannon.com
lndustrial / lnstrumentation
Rail
Defense Vehicles
Oil & Gas
Medical
Commercial & Military Aerospace
Our connector portfolio
remains the most extensive
Heavy Equipment
in the industry, offering a reliable and cost
effective range of interconnect solutions
www.ittcannon.com
3
Introduction to KPSE /KPT /KPTC
ITT Cannon's miniature circular connector series KPT, KPSE and KPTC
conform to meet the performance specification to MIL-C-26482 with a
positive three point bayonet coupling, five-keyway polarization and high
insert arrangement contact density.
Purpose
Highlights
••General purpose solder connectors (KPT)
– Our solution for small / prototype quantities
using solder type contacts
••All connectors conforming to the above mentioned standards
are fully intermateable and accept a wide range of interchangeable
accessories.
••High versatility general purpose versions using
crimp or solder contacts (KPTC)
– Our commercial version for higher volume production
with option for solder contacts
••Design modifications can be achieved easily and a lower
cost using Cannons KPSE / KPT or KPTC versions
••VG95328 versions are based on MIL-C-26482 but comply
to ECC directives and offer additional shielded versions
••High performance crimp connectors (KPSE)
– Our solution for volume production optimized for fast
assembly featuring “clip-in” contact & insulator design
••KPTC is based on MIL-C-26482 but offers a greater versatility
in contacts, backshells and plating options
••Military approved versions according to VG95328
or MIL-C-26482
••“Blue Generation” RoHS compliant, 500 hours salt spray and
conductive plating is offered next to the standard Nickel,
Zinc Cobalt or Cadmium platings.
Contact us for detail or your request
for a customized solution.
The broad product range provides the most complete family
of connectors conforming to VG95328 and MIL-C-26482
specifications.
Dimensions shown in mm | Specifications and dimensions subject to change
4
www.ittcannon.com
Product overview
KPT
KPSE
KPTC
Material and Finishes
Insulator
Aluminum alloy
Aluminum alloy
Aluminum alloy
Various RoHS compliant plating options are available like Zinc cobalt, Zinc Nickel and Nickel plus none compliant Cadmium
Polychloroprene
Polychloroprene
Polychloroprene
Grommet and seal
Polychloroprene
Polychloroprene
Polychloroprene
Contacts
Copper alloy, gold and tin plated
Copper alloy, gold and tin plated
Copper alloy, hard gold and tin plated
Shell
Mechanical Data
Shell styles
00 – Wall mounting receptacle
07 – Jam nut receptacle
01 – Cable connecting plug
08 – Plug with 90° termination assemblies
02 – Box mounting receptacle
  B – Thru-bulkhead receptacle (KPT only)
06 – Straight plug
Shell size
8 through 24
Polarization / Coupling
Five keyways / 3-point bayonet
A – General duty
E – Grommet seal
Service classes
F – Grommet seal with strain relief
PG – PG gland adapters
ME – metric gland adapters
According to VG95319 Part 2, Test No. 5.9.2 | For styles A to E and Z1, Z2 and Z3 and gaskets style A only,
test pressure 0,2 bar overpressure, test duration 48 h, test temperature 25 ±3°C, connector shall be free of moisture
Environmental sealing
Operating temperature
–55 / +125°C
Durability
500 mating cycles
Vibration
200 m/s² at 10 to 2000 Hz
Electrical Data
Number of contacts
2 through 61
3 through 61
Wire size AWG
16 through 24
12 through 24
2 through 61
0,4 – 2,0 mm²
Contact termination
Solder
Crimp
Crimp, solder
Contact rating
Size
Rated current A
Test current A
Millivolt drop mV
20
16
7,5
13,0
7,5
13,0
Less than 55
Less than 50
KPT /KPSE /KPTC
Insulation resistance
~ 5000 MΩ
Exceptions
Test voltage
Service rating between
the central contact and
the housing of the
coaxial contact
Seal Level
Service class
Vrms
VDC
1
1500
2100
2
2300
3200
1
375
535
2
550
770
21336 m / 70 000 ft.
Operating voltage (with scoop proof connectors operating voltages acc. to MIL-C-26482 and VG95328 are permitted)
Service class
Operating voltage
VG95328
MIL-C-26482
1
140 VDC/100 VAC
850 VDC/600 VAC
2
165 VDC/115 VAC
1400 VDC/1000 VAC
When the connectors in this catalogue are used for voltages
greater than 50 Volts and have touchable conductive shell parts
they must be used in accordance with the safety
regulations DIN VDE Part 140; IEC 60364-4-41. This regulation
basically dictates that the power source should be turned off
before any mating and unmating of the connector. This regulation does not provide protection against electrical shock when
mating and unmating the connectors in the live condition.
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
5
Table of contents
Product overview..................................................  5
How to use this catalogue.....................................  7
Part number creation............................................  8
Ordering reference................................................ 10
Contact arrangements........................................... 12
Alternate insert positions....................................... 15
Wall mounting receptacles.................................... 16
Cable connecting plugs......................................... 17
Box mounting receptacles..................................... 18
Thru-bulkhead receptacles..................................... 18
Straight plugs....................................................... 19
Jam nut receptacles............................................... 21
Right angle plugs.................................................. 22
Special versions
Connectors with grounding continuity.................. 23
Receptacles with straight solder pins..................... 26
Accessories and tooling
Panel cutouts........................................................ 27
Protective caps...................................................... 28
Dummy receptacle................................................ 30
Cross reference lists .............................................. 31
Tools and accessories ............................................ 32
KPSE contact and sealing principle ........................ 33
Product safety information.................................... 34
Dimensions shown in mm | Specifications and dimensions subject to change
6
www.ittcannon.com
How to use
This catalog is split in several sections that help you to
•• get a general overview of all product lines (product overview)
•• create a product part number step by step
(part number creation OR ordering reference)
•• get all required detail information (dimensions, product details)
•• get all required support products (accessories, tooling)
The fastest way to find your product of choice is to follow these steps
1
Select your product using either the “part number creation”
or “ordering reference” option
3
Add accessories and tooling as required on the related
pages
2
Use the detail pages to better understand the available
options and choose the best solution for your needs
4
Use the contact information on the back cover to contact
us for further questions or to get advise on where you can
purchase our products
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
7
Part number creation plug
Follow these steps to design your connector part number.
STEP 1 Select shell style (plug)
Shell Style
Plug
Shell Style
Plug
Shell Style
Plug
Plug straight
Solder
KPT06
KPTC6
Crimp
KPSE06
Plug straight
shielded
Solder
KPT6-DZ
KPTC6-DZ
Crimp
KPSE6-DZ
Plug 90°
Solder
KPT08
KPTC8
Crimp
KPSE08
Class F, 90°
Grommet seal
with thread
and cable clamp
Class A, 90°
General duty
with thread
Class E, 90°
Grommet seal
with thread
STEP 2 Choose backshell
Class A
General
duty with
thread
Class F
Grommet seal
with strain relief
Class E
add mod.
code DN
Environmental,
grommet seal,
heat shrink boot
adapter
Class PG; ME
KPTC only
Environmental
Class E
add Mod. code DZ
Environmental, grommet seal,
shielded heat shrink boot adapter
STEP 3 Choose layout
see page 12 –14 for layouts
STEP 4 Choose gender
P=pin S=socket
STEP 5 Choose rotation
see page 15 for rotation (omit for normal position)
STEP 6 Choose modification*
see page 11 for modifications (omit if no modification is required)
* If a modification is used the initial ‚0‘ in the shell style description is omitted e.g. KPT01 is changed to KPT1. KPTC series does never use the initial ‚0‘ e.g. KPTC6
Design your part number as per above steps
STEP 1
Shell style
STEP 2
Class / Backshell
STEP 3
Contact arrangement
STEP 4
Contact gender
Solder Industrial
KPT6
E
20 – 41
P
Crimp Industrial
KPSE6
E
14 – 12
S
KPSE / KPT
Examples
KPTC
Examples
STEP 1
Shell style
STEP 2
Class / Backshell
STEP 3
Contact arrangement
STEP 4
Contact gender
Solder Industrial
KPTC6
E
20 – 41
P
Crimp Industrial
KPTC6
PG
14 – 12
S
STEP 5
Insulation rotation
– DZ
–
STEP 6
Plating
W
STEP 5
Insulation rotation
C
–
STEP 6
Mod code (max. 3 codes)
D
– F42
– A240
– F0
STEP 6
Mod code (max. 3 codes)
– MA
W
– P13,5
– MB
Dimensions shown in mm | Specifications and dimensions subject to change
8
www.ittcannon.com
Part number creation receptacle
Follow these steps to design your connector part number.
STEP 1 Select shell style (receptacle)
Wall Mount
Solder
KPT00
KPTC0
Crimp
KPSE00
KPTC0
Cable connecting
Jam Nut*
Solder
KPT01
KPTC1
Solder
KPT07
KPTC7
Crimp
KPSE01
Box Mount*
Crimp
KPSE07
KPTC7
Solder
KPT02
KPTC2
Thru-Bulkhead
Crimp
KPSE02
KPTC2
KPTB
(contacts pre-installed)
STEP 2 Choose backshell
Class A
General
duty with
thread
Class F
Grommet seal
with strain relief
Class E
Environmental,
grommet seal,
no clamp
Class E
add Mod. code DN
Environmental,
grommet seal,
heat shrink boot
adapter
STEP 3 Choose layout
see page 12 –14 for layouts
STEP 4 Choose gender
P=pin S=socket
STEP 5 Choose rotation
see page 15 for rotation (omit for normal position)
STEP 6 Choose modification**
see page 11 for modifications (omit if no modification is required)
Class PG or ME
Environmental,
KPTC only
Class E
add Mod. code DZ
Environmental,
grommet seal
shielded heat
shrink boot
adapter
  * Shell style 02 (box mount) and 07A (jam nut) doesn‘t accept a backshell
** If a modification is used the initial ‚0‘ in the shell style description is omitted e.g. KPT01 is changed to KPT1. KPTC series does never use the initial ‚0‘ e.g. KPTC6
Design your part number as per above steps
STEP 1
Shell style
STEP 2
Class / Backshell
STEP 3
Contact arrangement
STEP 4
Contact gender
Solder Industrial
KPT02
E
20 – 41
P
Crimp Industrial
KPSE1
E
14 – 12
S
KPSE / KPT
Examples
KPTC
Examples
STEP 1
Shell style
STEP 2
Class / Backshell
STEP 3
Contact arrangement
STEP 4
Contact gender
Solder Industrial
KPTC2
E
20 – 41
P
Crimp Industrial
KPTC0
PG
14 – 12
S
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
9
STEP 5
Insulation rotation
–
STEP 6
Plating
W
STEP 5
Insulation rotation
C
–
D
STEP 6
Mod code (max. 3 codes)
– F42
– A240
STEP 6
Mod code (max. 3 codes)
– MA
W
– F0
– P13,5
– MB
Ordering reference
KPT / KPSE / KPTC
KP.. 02 E 22 – 36 P W *
Series
KPSE – Cannon prefix crimp, contacts supplied
KPT – Cannon prefix solder, contacts installed
KPTC – Cannon prefix commercial version, contacts to be ordered separately
Shell type
Cannon designation omit 0 in case of a mod code and KPTC
00 – wall mounting receptacle
see page 16
01 – cable connecting plug
see page 17
02 – box mounting receptacle (class E only), thru-bulkhead recep.
see page 18
06 – straight plug
see page 19/20
07 – jam nut receptacle
see page 21
08 – 90° angle plug
see page 22
Class
A – general duty with thread
E – grommet seal, environmental, no clamp
E – grommet seal, in combination with modification DN or DZ
F – grommet seal with strain relief
PG – endbell for PG glands
ME – endbell for metric glands
Shell size
8 – 24
Contact arrangement
see page 12–14
Contact type
P – pin
S – socket
Alternate insert position
W, X, Y and Z (omit for normal position)
see page 15
Modification
see page 11
* If a modification is used the initial ‚0‘ in the shell style description is omitted e.g. KPT01 is changed to KPT1. KPTC series does never use the initial ‚0‘ e.g. KPTC6
Dimensions shown in mm | Specifications and dimensions subject to change
10
www.ittcannon.com
KPSE/KPT-Modification codes
Multiple codes can be used in order of listing below
KPSE
KPTC-Modification codes
KPT
Multiple codes can be used in order of listing below
Endbell
KPTC
Plating
DN – heat shrink boot adapter, grommet seal
DN
DN
Nickel plating (RoHS compliant)
C
DZ – shielded, heat shrink boot adapter, grommet seal
DZ
DZ
Zinc Cobalt black plating (RoHS compliant)
R
F42 – without endbell, grommet and ferrule
F42
F42
Zinc Cobalt green plating (RoHS compliant)
F
Plating (Cadmium with olive drab chromate plating is standard; Alternative platings below)
Zinc Nickel plating (RoHS compliant) (not for code DZ)
H
A232 – Zinc Cobalt, black plating (RoHS compliant)
A232
A232
Cadmium with olive drab chromate
D
A240 – Zinc Nickel plating (RoHS compliant) (not for code DZ)
A240
A240
Endbell
A233 – Zinc Cobalt, green plating (RoHS compliant)
A233
A233
DN – heat shrink boot adapter, grommet seal
A34 – Nickel plating (RoHS compliant)
A34
A34
DZ – shielded, heat shrink boot adapter, grommet seal
DZ
F42 – without endbell, grommet and ferrule
F42
Contact
DN
F0 – connector without contacts
F0
F0
Endbell for PG glands (KPTC and KPT)
EX – PCB solder pin 0,76 x 7mm (style 02 and 07 only)
–
EX
PG09 - thread for shell size 10
P9
EW – PCB solder pin 0,6 x 7mm (style 02 and 07 only)
–
EW
PG11 – thread for shell size 12
P11
PG13,5 – thread for shell size14
P13,5
PG16 – thread for shell size 16
P16
PG21 – thread for shell size 18, 20, 22
P21
PG29 – thread for shell size 24
P29
Endbell for metric glands (KPTC and KPT)
M12 – thread for shell size 10
M12
M16 – thread for shell size 12
M16
M20 – thread for shell size 14
M20
M25 – thread for shell size 16, 18, 20
M25
M32 – thread for shell size 22, 24
M32
Contact
Connector supplied with solder pot contacts installed
MA
Connector supplied with crimp contacts
MB
Military approved version
VG95328
Specification
Shell type
see page 31
A – wall mounting receptacle with straight endbell
B – wall mounting receptacle with cable clamp
C – box mounting receptacle
D – jam nut receptacle
E – jam nut receptacle with cable clamp
J – straight plug with adapter DN
K – straight plug with cable clamp
M – straight plug, version DZ
R – wall mounting receptacle, version DZ
S – jam nut receptacle with adapter DN
Shell size 8, 10, 12, 14, 16, 18, 20, 22 and 24
Contact arrangements
see page 12 –14
Contact type P – pin S – socket
Alternate insert position
see page 15
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
11
A 18 – 1 S N
CONTACT ARRANGEMENTS
No. of contacts
Contact arrangements Service rating
Insulator position
Contact size
AWG
W
X
Y
Z
2
8-2  20
1
58
122
–
–
3
8-3  20
1
60
210
–
–
3
8-3A  20
1
60
–
–
–
3
8-33  20
1
90
–
–
–
4
8-4  20
1
45
–
–
–
6
10-6  20
1
90
–
–
–
10-7  20
1
90
–
–
–
7
6
10-98  20
1
90
180
240
270
3
12-3  16
2
–
–
180
–
8
12-8  20
1
90
112
203
292
10
12-10  20
1
60
155
270
295
14
12-14  20
1
60
155
270
295
5
14-5  16
2
40
92
184
273
12
14-12  20 (8)
16 (4)
1
43
90
–
–
Legend KPT KPSE  authorized per MIL-C-26482  authorized per VG95328
Dimensions shown in mm | Specifications and dimensions subject to change
12
www.ittcannon.com
CONTACT ARRANGEMENTS
No. of contacts
Contact arrangements Service rating
Insulator position
Contact size
AWG
W
X
Y
Z
15
14-15  20 (14)
16 (1)
1
17
110
155
234
18
14-18  20
1
15
90
180
270
19
14-19  20
1
30
165
315
–
5
14-22  12 (4)
20 (1)
1
–
–
–
–
4
14A4  Coax RG 188 U
1
–
–
–
–
8
16-8  16
2
54
152
180
331
23
16-23  20 (22)
16 (1)
1
158
270
–
–
26
16-26  20
1
60
–
275
338
11
18-11  16
2
62
119
241
340
32
18-32  20
2
85
138
222
265
(not for receptacle
shell style 02)
Legend KPT KPSE  authorized per MIL-C-26482  authorized per VG95328
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
13
CONTACT ARRANGEMENTS
No. of contacts
Contact arrangements Service rating
Insulator position
Contact size
AWG
W
X
Y
Z
20A6  12
2
90
180
270
–
16
20-16  16
2
238
316
333
347
24
20-24  20
1
70
145
215
290
39
20-39  20 (37)
16 (2)
1
63
114
252
333
41
20-41  20
1
45
126
225
–
21
22-21  16
2
16
135
175
349
36
22-36  20 1
72
144
216
288
41
22-41  20 (27)
16 (14)
39
135
264
–
55
22-55  20
1
30
142
226
314
61
24-61  20
1
90
180
270
324
5
Note: contacts are 1 grounding
pin and 4 standard size 12 pins
1
2
Legend KPT KPSE  authorized per MIL-C-26482  authorized per VG95328
Dimensions shown in mm | Specifications and dimensions subject to change
14
www.ittcannon.com
ALTERNATE INSERT POSITION
The diagram indicates alternate insert
positions.
The six positions N, V, W, Y, Z differ in
degree of rotation for various sizes and
arrangements. For the exact degree of
rotation, for the list of contact arrangements
and for alternate positions available, refer to
the table at the right.
Shell size No. of contacts
W
X
Y
Z
8-2
–
58
122
–
–
8-3
–
60
210
–
–
3
8-3A
–
60
–
–
–
3
8-33
–
90
–
–
–
4
8-4
–
45
–
–
–
6
10-6
–
90
–
–
–
7
10-7
–
90
–
–
–
6
10-98
–
90
180
240
270
3
12-3
–
–
–
180
–
8
12-8
–
90
112
203
292
10
12-10
–
60
155
270
295
14
12-14
–
60
155
270
295
4
14A4
–
–
–
–
–
5
14-5
–
40
92
184
273
12
14-12
–
43
90
–
–
15
14-15
–
17
110
155
234
18
14-18
–
15
90
180
270
19
14-19
–
30
165
315
–
5
14-22
–
–
–
–
–
8
16-8
–
54
52
180
331
23
16-23
–
158
270
–
–
26
16-26
–
60
–
275
338
11
18-11
–
62
119
241
340
32
18-32
–
85
138
222
265
5
20A6*
–
90
180
270
–
16
20-16
–
238
318
333
347
24
20-24
–
70
145
215
290
39
20-39
–
63
114
252
333
41
20-41
–
45
126
225
–
21
22-21
–
16
135
175
349
36
22-36
–
72
144
216
288
41
22-41
–
39
135
264
–
55
22-55
–
30
142
226
314
61
24-61
–
90
180
270
324
12
14
16
20
24
V
3
10
22
Degree of Rotation
2
8
18
Contact arrangements
* This contact arrangement features five contacts size 12. Four standard contacts and one is a first-to-mate contact.
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
15
WALL MOUNTING RECEPTACLES KPT00 / KPSE00 / KPTC0
Shell size
ØA
Q
+0,03 – 0,13 Thread Type 2A
K
M
R
S
ØT
±0,1
±0,15
±0,15
max.
±0,15
 8
12,00
7/16-28UNEF
1,9
11,6
15,1
21,0
3,05
10
15,00
9/16-24UNEF
1,9
11,6
18,3
24,2
3,05
12
19,05
11/16-24UNEF
1,9
11,6
20,6
26,6
3,05
14
22,23
13/16-20UNEF
1,9
11,6
23,0
29,0
3,05
16
25,40
15/16-20UNEF
1,9
11,6
24,6
31,3
3,05
18
28,58
1-1/16-18UNEF
1,9
11,6
27,0
33,7
3,05
20
31,75
1-3/16-18UNEF
2,2
14,25
29,4
36,9
3,05
22
34,93
1-5/16-18UNEF
2,2
14,25
31,8
40,1
3,05
24
38,10
1-7/16-18UNEF
2,2
15,1
34,9
43,3
3,75
VTHD
Thread Type 2A
Ø GF
min.
LF
max.
Ø BE
max.
Backshell options
Type A
Shell size
Ø DA
min.
L A
max.
Type F
HF
max.
Type E
L E
max.
 8
8,5
38,0
1/2-28UNEF
2,9
19,3
56,0
14,2
32,5
10
11,8
38,0
5/8-24UNEF
4,5
20,8
56,0
17,2
32,5
12
15,0
38,0
3/4-20UNEF
7,7
24,4
56,0
20,4
32,5
14
17,9
38,0
7/8-20UNEF
9,3
27,2
56,0
23,4
32,5
16
21,1
38,0
1-20UNEF
12,4
28,7
56,0
26,6
32,5
18
24,1
38,0
1-3/16-18UNEF
15,6
35,3
56,0
29,6
32,5
20
26,5
43,1
1-3/16-18UNEF
15,6
35,3
61,0
32,8
34,5
22
30,4
43,1
1-7/16-18UNEF
18,8
39,9
61,0
36,0
34,5
24
32,8
43,1
1-7/16-18UNEF
20,1
43,2
61,0
39,2
34,5
Mod. DN
Shell size
Ø D2
L1
L2
–0,5
max.
±0,5
 8
15,6
35,0
12,2
10
18,4
35,0
12,2
12
23,7
35,0
12,2
14
24,5
35,0
12,2
16
29,8
37,0
14,5
18
32,0
37,0
14,5
20
36,1
42,0
15,8
22
38,5
42,0
15,8
24
41,6
42,0
14,9
Dimensions shown in mm | Specifications and dimensions subject to change
16
www.ittcannon.com
CABLE CONNECTING PLUGS KPT01 / KPSE01 / KPTC1
Shell size
ØA
K
M
QTHD
S
ØY
+0,03 - 0,13
±0,1
±0,15
Thread Type 2A
max.
max.
 8
12,00
1,9
11,6
7/16-28UNEF
20,6
23,8
10
15,00
1,9
11,6
9/16-24UNEF
23,8
26,9
12
19,05
1,9
11,6
11/16-24UNEF
26,15
29,3
14
22,23
1,9
11,6
13/16-20UNEF
28,5
31,7
16
25,40
1,9
11,6
15/16-20UNEF
30,7
34,1
18
28,58
1,9
11,6
1-1/16-18UNEF
33,3
36,5
20
31,75
2,2
14,25
1-3/16-18UNEF
36,5
39,6
22
34,93
2,2
14,25
1-5/16-18UNEF
39,5
42,8
24
38,10
2,2
15,1
1-7/16-18UNEF
42,8
46,0
Backshell options
Type A
Shell size
Type F
Type E
Ø DA
L A
VTHD
Ø GF
HF
LF
Ø BE
L E
min.
max.
Thread Type 2A
min.
max.
max.
max.
max.
 8
8,5
38,0
1/2-28UNEF
2,9
19,3
56,0
14,2
32,5
10
11,8
38,0
5/8-24UNEF
4,5
20,8
56,0
17,2
32,5
12
15,0
38,0
3/4-20UNEF
7,7
24,4
56,0
20,4
32,5
14
17,9
38,0
7/8-20UNEF
9,3
27,2
56,0
23,4
32,5
16
21,1
38,0
1-20UNEF
12,4
28,7
56,0
26,6
32,5
32,5
18
24,1
38,0
1-3/16-18UNEF
15,6
35,3
56,0
29,6
20
26,5
43,1
1-3/16-18UNEF
15,6
35,3
61,0
32,8
34,5
22
30,4
43,1
1-7/16-18UNEF
18,8
39,9
61,0
36,0
34,5
24
32,8
43,1
1-7/16-18UNEF
20,1
43,2
61,0
39,2
34,5
Mod. DN
Shell size
Ø D2
L1
L2
– 0,5
max.
±0,5
 8
15,6
35,0
12,2
10
18,4
35,0
12,2
12
23,7
35,0
12,2
14
24,5
35,0
12,2
14,5
16
29,8
37,0
18
32,0
37,0
14,5
20
36,1
42,0
15,8
22
38,5
42,0
15,8
24
41,6
42,0
14,9
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
17
BOX MOUNTING RECEPTACLE KPT02 / KPSE02 / KPTC2
KPT / KPSE / KPTC
Shell size
KPT / KPTC
ØA
L
ØN
K
M
R
S
ØT
+0,03 – 0,13
max.
max.
±0,1
±0,15
±0,15
max.
±0,15
Z
max.
 8
12,00
21,1
11,1
1,9
11,6
15,1
21,0
3,05
12,3
10
15,00
21,1
14,3
1,9
11,6
18,3
24,2
3,05
12,3
12
19,05
21,1
17,5
1,9
11,6
20,6
26,6
3,05
12,3
14
22,23
21,1
20,6
1,9
11,6
23,0
29,0
3,05
12,3
16
25,40
21,1
23,8
1,9
11,6
24,6
31,3
3,05
12,3
18
28,58
21,1
27,0
1,9
11,6
27,0
33,7
3,05
12,3
20
31,75
22,7
30,2
2,2
14,25
29,4
36,9
3,05
10,8
22
34,93
22,7
33,4
2,2
14,25
31,8
40,1
3,05
10,8
24
38,10
22,7
36,5
2,2
15,1
34,9
43,3
3,75
10,0
THRU-BULKHEAD RECEPTACLES KPTB
Shell size
ØA
K
L
M
T
R
S
ØX
+0,03 – 0,13
±0,1
max.
±0,25
max.
±0,15
max.
±0,15
 8
12,00
1,8
28,6
14,5
6,0
15,1
21,0
3,05
10
15,00
1,8
28,6
14,5
6,0
18,3
24,2
3,05
12
19,05
1,8
28,6
14,5
6,0
20,6
26,6
3,05
14
22,23
1,8
28,6
14,5
6,0
23,0
29,0
3,05
16
25,40
1,8
28,6
14,5
6,0
24,6
31,3
3,05
18
28,58
1,8
28,6
14,5
6,0
27,0
33,7
3,05
20
31,75
2,5
31,9
17,7
9,2
29,4
36,9
3,05
22
34,93
2,5
31,9
17,7
9,2
31,8
40,1
3,05
24
38,10
2,5
31,9
17,7
8,0
34,9
43,3
3,75
Dimensions shown in mm | Specifications and dimensions subject to change
18
www.ittcannon.com
STRAIGHT PLUGS KPT06 / KPSE06 / KPTC6
Shell size
ØG
QTHD
max.
Thread Type 2A
 8
19,8
7/16-28UNEF
10
23,6
9/16-24UNEF
12
26,5
11/16-24UNEF
14
30,1
13/16-20UNEF
16
33,2
15/16-20UNEF
18
35,4
1-1/16-18UNEF
20
39,0
1-3/16-18UNEF
22
42,1
1-5/16-18UNEF
24
45,2
1-7/16-18UNEF
Backshell options
Type A
Shell size
Type F
Type E
Ø DA
L A
VTHD
Ø GF
L F
HF
Ø BE
L E
min.
max.
Thread Type 2A
min.
max.
max.
max.
max.
32,5
 8
8,5
42,0
1/2-28UNEF
2,9
56,0
19,3
14,2
10
11,8
42,0
5/8-24UNEF
4,5
56,0
20,8
17,2
32,5
12
15,0
42,0
3/4-20UNEF
7,7
56,0
24,4
20,4
32,5
14
17,9
42,0
7/8-20UNEF
9,3
56,0
27,2
23,4
32,5
16
21,1
42,0
1-20UNEF
12,4
59,0
28,7
26,6
32,5
18
24,1
42,0
1-3/16-18UNEF
15,6
59,0
35,3
29,6
32,5
20
26,5
45,0
1-3/16-18UNEF
15,6
59,0
35,3
32,8
34,5
22
30,4
45,0
1-7/16-18UNEF
18,8
59,0
39,9
36,0
34,5
24
32,8
45,0
1-7/16-18UNEF
20,1
59,0
43,2
39,2
34,5
Mod. DN
Shell size
Ø D2
L1
L2
– 0,5
max.
±0,5
 8
15,6
35,0
12,2
10
18,4
35,0
12,2
12
23,7
35,0
12,2
14
24,5
35,0
12,2
16
29,8
37,0
14,5
18
32,0
37,0
14,5
20
36,1
42,0
15,8
22
38,5
42,0
15,8
24
41,6
42,0
14,9
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
19
STRAIGHT PLUG KPT6PG / KPTC6PG
Shell size
ØG
ØB
C
LPG
max.
max.
min.
max.
PGTHD
10
23,6
19,0
10,5
58,5
12
26,5
22,5
10,5
58,5
PG 09
PG 11
14
30,1
25,0
10,5
58,5
PG 13,5
16
33,2
28,0
10,5
73,0
PG 16
18
35,4
32,5
11,5
73,0
PG 21
20
39,0
34,5
11,5
76,0
PG 21
22
42,1
38,0
11,5
82,0
PG 21
24
45,2
40,5
11,5
82,0
PG 29
Metric Thread
STRAIGHT PLUG KPT6ME / KPTC6ME
Shell size
ØG
ØB
C
LME
max.
max.
min.
max.
10
23,6
19,0
10,5
58,5
M 12 x 1,5
12
26,5
22,5
10,5
58,5
M 16 x 1,5
14
30,1
25,0
10,5
58,5
M 20 x 1,5
16
33,2
28,0
10,5
73,0
M 25 x 1,5
18
35,4
32,5
11,5
73,0
M 25 x 1,5
20
39,0
34,5
11,5
76,0
M 25 x 1,5
22
42,1
38,0
11,5
82,0
M 32 x 1,5
24
45,2
40,5
11,5
82,0
M 32 x 1,5
Dimensions shown in mm | Specifications and dimensions subject to change
20
www.ittcannon.com
JAM NUT RECEPTACLES KPT07 / KPSE07 / KPTC7
Shell size
ØA
F
H
K
M
RTHD
S
+0,03 – 0,13
±0,15
±0,15
±0,25
±0,15
Thread Type 2A
±0,5
T Panel thickness
ØN
min.
max.
max.
 8
12,00
13,3
19,0
3,2
17,7
9/16-24UNEF
24,0
1,6
3,5
28,0
10
15,00
16,5
22,2
3,2
17,7
11/16-24UNEF
27,0
1,6
3,5
31,0
12
19,05
20,6
27,0
3,2
17,7
7/8-20UNEF
32,0
1,6
3,5
36,0
14
22,23
23,8
30,2
3,2
17,7
1-20UNEF
35,0
1,6
3,5
39,0
16
25,40
26,9
33,3
3,2
17,7
1-1/8-18UNEF
38,5
1,6
3,5
42,0
18
28,58
30,1
36,5
3,2
17,7
1-1/4-18UNEF
41,5
1,6
3,5
45,0
20
31,75
33,3
39,7
4,0
22,5
1-3/8-18UNEF
46,0
1,6
6,5
50,0
22
34,93
36,5
42,9
4,0
22,5
1-1/2-18UNEF
49,5
1,6
6,5
55,0
24
38,10
39,6
46,0
4,0
23,3
1-5/8-18UNEF
52,5
1,6
6,5
57,0
Backshell options
Type F
Shell size
Type E
Type DN
Type A KPT / KPTC
LF
Ø GF
HF
Ø BE
LE
L1
L2
Ø D2
Z
max.
max.
max.
max.
max.
max.
±0,5
max.
max.
 8
44,9
2,9
19,3
18,2
33,5
43,0
12,2
15,6
7,9
10
44,9
4,5
20,8
21,5
33,5
43,0
12,2
18,4
7,9
12
44,9
7,7
24,4
24,6
33,5
43,0
12,2
23,7
7,9
14
44,9
9,3
27,2
27,8
33,5
43,0
12,2
24,7
7,9
16
48,4
12,4
28,7
31,0
33,5
45,5
14,5
29,8
7,9
18
48,4
15,6
35,3
34,1
33,5
45,5
14,5
32,0
7,9
20
50,3
15,6
35,3
38,1
39,0
52,6
15,8
36,1
4,7
22
50,3
18,8
39,9
41,3
39,0
52,6
15,8
28,5
4,7
24
50,3
20,1
43,2
44,5
39,0
51,6
14,9
41,6
3,8
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
21
RIGHT ANGLE PLUG, 90° KPT08 / KPSE08 / KPTC8
Shell size
ØG
Q
max.
Thread Type 2A
 8
19,8
7/16-28UNEF
10
23,6
9/16-24UNEF
12
26,5
11/16-24UNEF
14
30,1
13/16-20UNEF
16
33,2
15/16-20UNEF
18
35,4
1-1/16-18UNEF
20
39,0
1-3/16-18UNEF
22
42,1
1-5/16-18UNEF
24
45,2
1-7/16-18UNEF
Backshell options
Type A and E
Shell size
Type F
LAE
DAE
VTHD
L
DF
LF
max.
max.
Thread Type 2A
max.
max.
max.
 8
36,1
20,9
1/2-28UNEF
47,0
31,4
36,1
10
38,3
21,7
5/8-24UNEF
49,5
32,2
38,3
40,9
12
40,9
23,3
3/4-20UNEF
53,5
35,4
14
41,6
24,9
7/8-20UNEF
55,5
38,6
41,6
16
42,5
26,5
1-20UNEF
57,0
40,2
42,5
18
44,7
28,1
1-3/16-18UNEF
62,5
41,8
44,7
20
48,3
29,6
1-3/16-18UNEF
67,0
43,4
48,3
22
52,1
31,7
1-7/16-18UNEF
71,5
47,9
52,1
24
52,1
33,6
1-7/16-18UNEF
74,0
49,9
52,1
Dimensions shown in mm | Specifications and dimensions subject to change
22
www.ittcannon.com
VERSIONS WITH GROUNDING CONTINUITY KPT / KPSE / KPTC
These connectors are designed to ensure electrical continuity
••at the cable shielding level to protect it against radio frequency interferences
••at the grounding level (if it is connected to the shielding)
The plugs are manufactured with grounding fingers fixed to the front face of the shell. They make contact with the inner side of the
receptacle shell. Plug and receptacle feature a special backshell which supports the cable shielding. The connectors are in accordance
with the VG95328 specification.
RECEPTACLE WITH GROUNDING CONTINUITY (for shielded cable) KPT0E / KPSE0E / KPTC0E… DZ
Shell size
ØA
ØB
ØC
ØD
E
K
L
M
R
S
ØT
+0,03 – 0,13
min.
±0,5
max.
±1,0
±0,1
max.
±0,15
±0,15
max.
±0,15
 8
12,00
6,6
16,0
13,3
15,0
1,9
52,0
11,6
15,1
21,0
3,05
10
15,00
9,2
18,0
16,1
15,0
1,9
52,0
11,6
18,3
24,2
3,05
12
19,05
12,2
22,0
20,0
17,0
1,9
52,0
11,6
20,6
26,6
3,05
14
22,23
15,2
25,0
22,2
18,0
1,9
53,0
11,6
23,0
29,0
3,05
16
25,40
18,3
28,0
26,2
18,0
1,9
53,0
11,6
24,6
31,3
3,05
18
28,58
20,0
32,0
28,5
18,0
1,9
53,0
11,6
27,0
33,7
3,05
20
31,75
23,0
34,0
32,5
18,0
2,2
58,0
14,25
29,4
36,9
3,05
22
34,93
26,0
38,0
34,8
18,0
2,2
58,0
14,25
31,7
40,1
3,05
24
38,10
28,8
41,0
37,9
18,0
2,2
58,0
15,1
34,9
43,3
3,75
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
23
CABLE CONNECTING PLUG WITH GROUNDING CONTINUITY (for shielded cable) KPT1E / KPSE1E / KPTC1E … DZ
Shell size
ØA
M
ØB
ØC
ØD
E
K
L
S
ØY
+0,03 – 0,13
±0,15
min.
±0,5
max.
±1,0
±0,1
max.
max.
max.
 8
12,00
11,6
6,6
16,0
13,3
15,0
1,9
52,0
18,5
21,0
10
15,00
11,6
9,2
18,0
16,1
15,0
1,9
52,0
23,0
24,2
12
19,05
11,6
12,2
22,0
20,0
17,0
1,9
52,0
29,0
26,6
14
22,23
11,6
15,2
25,0
22,2
18,0
1,9
53,0
29,5
29,0
16
25,40
11,6
18,3
28,0
26,2
18,0
1,9
53,0
32,0
31,3
18
28,58
11,6
20,0
32,0
28,5
18,0
1,9
53,0
35,0
33,7
20
31,75
14,25
23,0
34,0
32,5
18,0
2,2
58,0
38,5
36,9
22
34,93
14,25
26,0
38,0
34,8
18,0
2,2
58,0
42,0
40,1
24
38,10
14,25
28,8
41,0
37,9
18,0
2,2
58,0
46,0
43,3
STRAIGHT PLUG WITH GROUNDING CONTINUITY KPT6E / KPSE6E / KPTC6E … DZ
Shell size
ØB
ØC
ØG
ØD
E
L
S
min.
+0,5
max.
max.
1,0
max.
+0,2
 8
6,6
16,0
19,1
13,3
15,0
48,0
17,00
10
9,2
18,0
22,0
16,1
15,0
48,0
19,00
12
12,2
22,0
26,2
20,0
17,0
48,0
23,00
14
15,2
25,0
29,4
22,2
18,0
49,0
26,00
16
18,3
28,0
32,8
26,2
18,0
49,0
29,00
18
20,0
32,0
35,4
28,5
18,0
49,0
33,00
20
23,0
34,0
39,0
32,5
18,0
53,0
35,00
22
26,0
38,0
42,1
34,8
18,0
53,0
39,00
24
28,8
41,0
45,2
37,9
18,0
53,0
42,00
Dimensions shown in mm | Specifications and dimensions subject to change
24
www.ittcannon.com
JAM NUT RECEPTACLE WITH GROUNDING CONTINUITY (for shielded cable) KPT 7E / KPSE 7E / KPTC … DZ
Shell size
ØA
ØB
ØC
ØD
E
L
S
T
min.
+0,5
max.
max.
±1,0
max.
±0,25
±0,25
 8
6,6
16,0
18,2
13,3
15,0
47,0
23,0
19,0
10
9,2
18,0
21,4
16,1
15,0
47,0
27,0
22,2
12
12,2
22,0
24,6
20,0
17,0
49,0
31,7
27,0
14
15,2
25,0
27,8
22,2
18,0
50,0
34,9
30,2
16
18,3
28,0
30,9
26,2
18,0
50,0
38,1
33,3
18
20,0
32,0
34,1
28,5
18,0
50,0
41,3
36,5
20
23,0
34,0
38,1
32,5
18,0
55,0
46,0
39,7
22
26,0
38,0
41,3
34,8
18,0
55,0
49,2
42,9
24
28,8
41,0
44,4
37,9
18,0
55,0
52,3
46,0
ASSEMBLY OF A CONNECTOR WITH A GROUND CONTINUITY BACKSHELL KPT / KPSE / KPTC … DZ
Shell size
ØC
max.
 8
6,6
10
9,2
12
12,2
14
15,2
16
18,3
18
20,0
20
23,0
22
26,0
24
28,8
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
25
BOX MOUNTING RECEPTACLE KPT2 / KPTC2 … EX OR EW
Shell size
ØA
+0,03 – 0,13
K
±0,1
L
M
ØN
R
S
ØT
max.
±0,15
max.
±0,15
max.
±0,15
 8
12,00
1,9
21,1
11,60
11,1
15,1
21,0
3,05
10
15,00
1,9
21,1
11,60
14,3
18,3
24,2
3,05
12
19,05
1,9
21,1
11,60
17,5
20,6
26,6
3,05
14
22,23
1,9
21,1
11,60
20,6
23,0
29,0
3,05
16
25,40
1,9
21,1
11,60
23,8
24,6
31,3
3,05
18
28,58
1,9
21,1
11,60
27,0
27,0
33,7
3,05
20
31,75
2,2
22,7
14,25
30,2
29,4
36,9
3,05
22
34,93
2,2
22,7
14,25
33,4
31,7
40,1
3,05
24
38,10
2,2
22,7
15,10
36,5
34,9
43,3
3,75
T (Panel Thickness)
JAM NUT RECEPTACLES KPT7 / KPTC7 …EX OR EW
Shell size
ØA
F
H
K
M
RTHD
S
+0,03 – 0,13
±0,15
±0,15
±0,25
±0,15
Thread Type 2A
±0,5
min.
max.
ØN
max.
 8
12,0
13,3
19,0
3,2
17,7
9/16-24UNEF
24,0
1,6
3,5
28,0
10
15,0
16,5
22,2
3,2
17,7
11/16-24UNEF
27,0
1,6
3,5
31,0
12
19,1
20,6
27,0
3,2
17,7
7/8-20UNEF
32,0
1,6
3,5
36,0
14
22,2
23,8
30,2
3,2
17,7
1-20UNEF
35,0
1,6
3,5
39,0
16
25,4
26,9
33,3
3,2
17,7
1-1/8-18UNEF
38,5
1,6
3,5
42,0
18
28,6
30,1
36,5
3,2
17,7
1-1/4-18UNEF
41,5
1,6
3,5
45,0
20
31,8
33,3
39,7
4,0
22,5
1-3/8-18UNEF
46,0
1,6
6,5
50,0
22
34,9
36,5
42,9
4,0
22,5
1-1/2-18UNEF
49,5
1,6
6,5
55,0
24
38,1
39,6
46,0
4,0
23,3
1-5/8-18UNEF
52,5
1,6
6,5
57,0
Dimensions shown in mm | Specifications and dimensions subject to change
26
www.ittcannon.com
PANEL CUTOUTS KPT / KPSE / KPTC
BOX MOUNTING RECEPTACLE
Shell size
For rear mounting
For front mounting
Ø D +0,25 / 0
Ø D +0,25 / 0
R ±0,15
 8
14,0
12,7
15,1
3,1
10
17,0
16,0
18,3
3,1
12
22,0
19,0
20,6
3,1
14
25,0
22,2
23,0
3,1
16
28,0
25,5
24,6
3,1
18
31,0
28,5
27,0
3,1
20
34,5
31,7
29,4
3,1
22
37,5
35,0
31,8
3,1
24
41,0
38,0
34,9
3,6
PANEL THICKNESS
P – Panel thickness
Shell size
Height of screw head included
 8
2,2
10
2,2
12
2,2
14
2,2
16
2,2
18
2,2
20
5,4
22
5,4
24
5,4
JAM NUT RECEPTACLE
KPT / KPSE
KPT / KPSE
Ø A +0,25 / –0
B +0 / –0,12
 8
14,5
13,6
10
17,7
16,8
12
22,7
20,9
14
25,7
24,1
16
28,8
27,2
18
32,0
30,4
20
35,1
33,6
22
38,4
36,8
24
41,5
40,0
Shell size
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
27
Ø T +0,3
PROTECTIVE CAPS KPT / KPSE / KPTC
Material
Protective cap
Aluminum alloy
Sash chain
Stainless steel
Cord
Polyamide
Ring
Stainless steel
Clip
Aluminum alloy
Gasket
Fluor Silicone
End link / rivet
Stainless steel, passivated
Bayonet pin
Stainless steel, passivated
HOW TO ORDER
KPT80- 10
D- A34
KPTC80-
Series
Series
KPT80 – for plug
KPTC80 – for plug
KPT81 – for receptacle
KPTC81 – for receptacle
Shell size
Shell size
8 – 24
8 – 24
Termination
Termination
D – Nylon cord 400 mm
C – Nylon cord and endlink
Clip and end link attached (not assembled)
Crimp tool for end link: M317 (selector position 6)
10
C- C
Modification
C – sash chain and terminal link
C – Nickel plated (RoHS compliant)
CB – Nylon cord and terminal link
D – Cadmium plated
N – chain with ring (KPT81 only)
R – Zinc cobalt, black (RoHS compliant)
NB – Nylon cord with ring (KPT81 only)
F – Zinc cobalt, green (RoHS compliant)
H – Zinc nickel plating (RoHS compliant)
Modification
A34 – Nickel plated (RoHS compliant)
A232 – Zinc cobalt, black (RoHS compliant)
A233 – Zinc cobalt, green (RoHS compliant)
A240 – Zinc nickel plating (RoHS compliant)
A66 (without code) – Olive drab chromate over cadmium
VG95328 Z2
C
10
VG Specification
Style
Z1 – for receptacle
Z2 – for plug
Z3 – for jam nut receptacle
Termination
A – chain and terminal link
C – for Z1 and Z2:
Nylon cord 400 mm and end link
Clip and end link attached (not mounted)
Crimp tool for end link: M317 (selector position 6)
C – for Z3: Nylon cord with ring
Shell size
8 – 24
Dimensions shown in mm | Specifications and dimensions subject to change
28
www.ittcannon.com
PROTECTIVE CAPS KPT / KPSE / KPTC
Cap with nylon cord
For receptacle
KPT81 termination D
VG95328 Z1 termination C
For plug
KPT80 termination D
VG95328 Z2 termination C
Cap with nylon cord and terminal link
For receptacle
KPT81 termination C and CB
VG95328 Z1 termination A
For plug
KPT80 termination C and CB
VG95328 Z2 termination A
Cap with nylon cord and ring
For receptacle
KPT81 termination N and NB
VG95328 Z3 termination C
ØA
L1
ØB
L2
H
ØN
max.
max.
max.
max.
max.
±0,5
 8
18,26
19,84
18,0
21,44
76
14,7
10
21,44
19,84
20,3
21,44
76
17,9
12
25,40
19,84
25,1
21,44
89
22,6
14
28,58
19,84
28,2
21,44
89
25,8
16
31,75
19,84
31,5
21,44
89
29,0
18
34,92
19,84
34,5
21,44
89
32,2
20
38,10
21,44
37,8
21,44
101
35,3
22
41,28
21,44
40,9
21,44
101
38,5
24
44,45
22,22
44,2
22,22
101
41,7
Shell size
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
29
DUMMY RECEPTACLES KPT/KPSE/KPTC
HOW TO ORDER
KPT
MS
158
3115- 8
A
A
Series
Dummy receptacle
Shell size
Flange
A – Standard
Shell size
ØA
K
M
R
S
ØT
+0,03 – 0,13
±0,4
±0,15
±0,15
max.
±0,15
* 8 A
12,00
1,6
12,1
15,1
21,0
3,05
* 10 A
15,00
1,6
12,1
18,3
24,2
3,05
* 12 A
19,05
1,6
12,1
20,6
26,6
3,05
* 14 A
22,23
1,6
12,1
23,0
29,0
3,05
* 16 A
25,40
1,6
12,1
24,6
31,3
3,05
* 18 A
28,58
1,6
12,1
27,0
33,7
3,05
* 20 A
31,75
2,4
14,5
29,4
36,9
3,05
* 22 A
34,93
2,4
14,5
31,8
40,1
3,05
* 24 A
38,10
2,4
15,4
34,9
43,3
3,75
* Add “KPT 15 -” or “MS 3115-” prefixes
Dimensions shown in mm | Specifications and dimensions subject to change
30
www.ittcannon.com
CROSS REFERENCE LIST KPT / KPSE / VG95328 / MIL-C-26482
Solder
ITT Cannon
MIL-C-26482
Crimp
VG95328
ITT Cannon
MIL-C-26482
VG95328
KPT00E
MS3110E
KPSE00E
MS3120E
VG95328A
KPT00F
MS3110F
KPSE00F
MS3120F
VG95328B
KPT0E-DN
KPSE0E-DN
KPT0E-DZ
KPSE0E-DZ
KPT01A
KPSE01A
VG95328R
KPT01E
MS3111E
KPSE01E
MS3121E
KPT01F
MS3111F
KPSE01F
MS3121F
KPT1E-DN
KPSE1E-DN
KPT1E-DZ
KPT02E
KPSE1E-DZ
MS3112E
VG95328H
KPSE02E
KPT06A
MS3122E
VG95328C
KPSE06A
KPT06E
MS3116E
KPSE06E
MS3126E
KPT06F
MS3116F
KPSE06F
MS3126F
VG95328K
KPT6E-DN
KPSE6E-DN
VG95328J
KPT6E-DZ
KPSE6E-DZ
VG95328M
KPT07A
KPSE07A
KPT07E
MS3114E
KPSE07E
MS3124E
VG95328D
KPT07F
MS3114F
KPSE07F
MS3124F
VG95328E
KPT7E-DN
KPSE7E-DN
KPT7E-DZ
KPSE7E-DZ
KPT08E
KPSE08E
KPT08F
KPTB
KPSE08F
MS3119
VG95328P
CROSS REFERENCE LIST PROTECTIVE CAPS KPT / VG95328 / MIL-C-26482
Part No.
ITT Cannon
KPT80
Part No.
MIL-C-26482
MS3180
KPT80..C
KPT81
Z2...VG95328
MS3181
KPT81..C
KPT81..N
Part No.
VG95328
Z1...VG95328
MS 3181..N
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
31
VG95328S
TOOLS AND ACCESSORIES KPT / KPSE / KPTC
TOOLS
KPSE / KPTC
Tool
Hand crimp tool
Crimp machine
Crimp machine
Designation
M22520/1-01
WA27F-CE
HACS
Order reference
995-0001-585
121586-5067
HACS
Locator*
M22520/1-02
M22520/1-02
–
Order reference
995-0001-736
995-0001-736
–
Test gage
M22520/3-1
M22520/3-1
–
Order reference
995-0001-684
995-0001-684
–
* for contact sizes 20, 16, 12
KPSE
Contact size
20*
20**
Insertion tool
–
M24256A20
Order reference
038894-0018
995-0001-950
Old designation Extraction tool
CIT-20-16
MS2425R20
CIT-20-5A
MS2425R20
Order reference
995-0001-965
995-0001-965
Extraction TIP
317-7130-000
317-7130-000
16
12
M24256A16
M24256A12
995-0001-951
995-0001-913
CIT-16-1
–
MS2425R16
MS2425R12
995-0001-964
995-0001-966
317-7129-000
317-7131-000
Order ref.
121086-3101
121086-0097
Extraction tool
CET-KPTC-20
CET-KPTC-16
Extraction TIP
CET-KPTC-20-TIP
CET-KPTC-16-TIP
Order reference
070064-0000
LN
–
* without insulation support ** with insulation support
KPTC
Contact size
20
16
Insertion tool
CITG-20A
CIT-16
Order ref.
12086-3104
121086-3008
Insertion pliers
CIT-KPTC-20
CIT-F80-16
Insertion tool
–
Order reference
–
Old designation Extraction tool
–
CET-C6B
KPT14A4
Contact type
Coaxial
CONTACTS KPT / KPSE / KPTC /
VG95328
KPSE / VG95328
Contact size
Contact type
20
Socket with insulation support
Pin with insulation support
Socket
Pin
Contact order reference
KPSE version
VG95328 version
031-8704-203 031-8704-203
430-8560-006 430-8560-006
031-8704-000 031-8704-000
430-8560-004 430-8560-004
Socket
031-8704-012
Pin
Grounding pin
430-8560-016
430-8560-020
16
12
KPTC
Contact size
20Socket
Pin
16Socket
Pin
Order reference (hard gold plated)
031-8704-508
430-8560-404
031-8704-502
430-8560-406
For shell size 8 and contact arrangements 12-14 only:
Contact size
Order reference
hard gold plated
hard silver plated
20 Socket
031-8704-509
031-8704-506
20 Pin
430-8560-411
430-8560-410
KPT14A4
Coaxial
WIRE HOLE FILLERS
KPSE / KPTC
Pin
Socket
DM 53740-5001
DM 53742-5001
KPSE/KPTC
Contact size
20
16
12*
Coaxial 14A4*
Colour code
Red
Blue
Yellow
Yellow
MS
MS3187A20
MS3187-16A
MS3187-12
–
Cannon
225-1012-000
225-1011-000
225-0072-000
225-0018-000
* KPSE only
GASKETS KPT / KPSE / KPTC KPT / KPSE / KPTC
Shell size
 8
10
12
14
16
Alu-Flex
conductive
075-8543-000
075-8543-001
075-8543-002
075-8543-003
075-8543-004
Chloroprene
non conductive
075-8543-010
075-8543-011
075-8543-012
075-8543-013
075-8543-014
Shell size
18
20
22
24
Alu-Flex
conductive
075-8543-005
075-8543-006
075-8543-007
075-8543-008
Chloroprene
non conductive
075-8543-015
075-8543-016
075-8543-017
075-8543-018
Dimensions shown in mm | Specifications and dimensions subject to change
32
www.ittcannon.com
KPSE CONTACT AND SEALING PRINCIPLE
••High performance
••Crimp termination
••Closed entry socket contacts
Series KPSE environmental, miniature circular, quick disconnect
connectors are designed for the extracting requirements of today’s
electronic industry.
They are intermateable, intermountable and interchangeable
with all connectors manufactured according to MIL-C-26482,
VG95328 and HE 301.
Connectors of Cannon series KPSE have obtained the
VDE Expertise No. 63761.
1
Standard MIL-C-26482 or Hardware mates with any
connector designed to MIL-C-26482 and VG95328 model
2
Crimp, snap-in contacts are designed to SAE-AS-39029
and can be crimped with the standard M22520/1 crimp
tool.
Complete moisture sealing is achieved by combining
four seals: shell, peripheral, interfacial and wire seals.
CLOSED-ENTRY SOCKET CONTACTS eliminate damage
from abuse by test probes and help to correct any
misaligned pins during engagement.
SHELL SEAL is effected when the plug shell pushes against
the sealing ring in the receptacle when the connectors are
mated.
CONTACT INSERTION is accomplished from the rear of
the connector. When the contact is fully inserted, the clip
tines snap securely behind the contact shoulder.
PERIPHERAL SEAL around the edge of the pin insulator is
designed so that mating the connector puts tension on
the seal and greatly reduces compression set.
CONTACT EXTRACTION is accomplished with a frontinserted extraction tool. Pressing the tool plunger pushes
the contact out through the rear of the connector.
INTERFACIAL SEAL is achieved by the insulator faces
meeting when the plug and receptacle are mated.
4
Contact retention
RETAINING CLIP: completely encased in a tough plastic
wafer to protect the clip from damage
PLASTIC WAFER: latest version for easier and faster assembly
and disassembly of contacts (used on selected layouts)
WIRE SEAL is accomplished by a multiple ripple design,
exceeding the wire sealing requirements of MIL-C-26482.
3
5
Monobloc insulator does not leave any access to
moisture and avoids interfacial empty space.
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
33
Positive insert-to-shell mechanical retention with hard
plastic wafer firmly locked into a groove in the shell, in addition to a strong adhesive bond between the insert and shell.
PRODUCT SAFETY INFORMATION
1. MATERIAL CONTENT AND PHYSICAL
FORM
Electrical connectors do not usually contain
hazardous materials. They contain conducting
and non-conducting materials and can be
divided into two groups.
a) Printed circuit types and low cost audio types
which employ all plastic insulators and casings.
b) Rugged, Fire Barrier and High Reliability
types with metal casings and either natural
rubber, synthetic rubber, plastic or glass
insulating materials. Contact materials vary
with type of connector and also application
and are usually manufactured from either:
Copper, copper alloys, nickel, alumel, chromel
or steel. In special applications, other alloys
may be specified.
2. FIRE CHARACTERISTICS AND ELECTRIC
SHOCK HAZARD
There is no fire hazard when the connector is
correctly wired and used within the specified
parameters.
Incorrect wiring or assembly of the connector
or careless use of metal tools or conductive
fluids, or transit damage to any of the
component parts may cause electric shock or
burns. Live circuits must not be broken by
separating mated connectors as this may cause
arcing, ionization and burning. Heat
dissipation is greater at maximum resistance in
a circuit. Hot spots may occur when resistance
is raised locally by damage, e.g. cracked or
deformed contacts, broken strands of wire.
Local overheating may also result from the use
of the incorrect application tools or from poor
quality soldering or slack screw terminals.
Overheating may occur if the ratings in the
product Data Sheet/Catalog are exceeded and
can cause breakdown of insulation and hence
electric shock. If heating is allowed to continue
it intensifies by further increasing the local
resistance through loss of temper of spring
contacts, formation of oxide film on contacts
and wires and leakage currents through
carbonization of insulation and tracking paths.
Fire can then result in the presence of
combustible materials and this may release
noxious fumes. Overheating may not be visually apparent. Burns may result from touching
overheated components.
3. HANDLING
Care must be taken to avoid damage to any
component parts of electrical connectors
during installation and use. Although there are
normally no sharp edges, care must be taken
when handling certain components to avoid
injury to fingers.
Electrical connectors may be damaged in
transit to the customers, and damage may
result in creation of hazards. Products should
therefore be examined prior to installation/use
and rejected if found to be damaged.
4. DISPOSAL
Incineration of certain materials may release
noxious or even toxic fumes.
5. APPLICATION
Connectors with exposed contacts should not
be selected for use on the current supply side
of an electrical circuit, because an electric
shock could result from touching exposed
contacts on an unmated connector. Voltages
in excess of 30 V ac or 42.5 V DC are
potentially hazardous and care should be taken
to ensure that such voltages cannot be
transmitted in any way to exposed metal parts
of the connector body. The connector and
wiring should be checked, before making live,
to have no damage to metal parts or
insulators, no solder blobs, loose strands,
conducting lubricants, swarf, or any other
undesired conducting particles. Circuit
resistance and continuity check should be
made to make certain that there are no high
resistance joints or spurious conducting paths.
Always use the correct application tools as
specified in the Data Sheet/Catalog. Do not
permit untrained personnel to wire, assemble
or tamper with connectors. For operation
voltage please see appropriate national
regulations.
used in accordance with the specifications in
this publication. Any use or application
that deviates from the stated operating
specifications is not recommended and may
be unsafe. No information and data contained
in this publication shall be construed to create
any liability on the part of Cannon. Any new
issue of this publication shall automatically
invalidate and supersede any and all previous
issues.
IMPORTANT GENERAL INFORMATION
(i) Air and creepage paths/Operating
voltage. The admissible operating voltages
depend on the individual applications and the
valid national and other applicable safety
regulations. For this reason the air and
creepage path data are only reference values.
Observe reduction of air and creepage paths
due to PC board and/or harnessing.
(ii) Temperature
All information given are temperature limits.
The operation temperature depends on the
individual application.
(iii) Other important information
Cannon continuously endeavors to improve
their products. Therefore, Cannon products
may deviate from the description, technical
data and shape as shown in this catalog and
data sheets.
ITT's Interconnect Solutions, is a division of ITT
Corporation who manufactures the highest
quality products available in the marketplace;
however these products are intended to be
34
www.ittcannon.com
Circular / Filter / Hermetic / Fiber Optic Connectors
As a world leader in circular, filter, and hermetic connectors, ITT can
leverage its design and manufacturing expertise to fit virtually any
application. Our expertise includes fast positive mating for a
wide range of military applications, as well as numerous sizes
and contact configurations for various harsh environments. Our
wide variety of fiber optic products include hybrid contacts,
multi-channel, rack and panel, and hi-rel assemblies, including MIL
and ARINC standard solutions that meet numerous specifications,
including NATO and MIL standards.
D-Subminiature Connectors
Cannon invented D-sub connectors in 1952. Our family of D-Subs
now includes combinations of signal, power and RF, as well as
severe service sealed connectors. Cannon D-Subs are available
with an extensive line of backshells and accessories and are one
of the most economical shielded connector solutions available. ITT
D-Sub connectors are qualified to the MIL-DTL-24308 specification.
Microminiature Connectors
Developed first by Cannon in the 1960’s, ITT's Interconnect Solutions
microminiature connectors offer high performance and reliability
with exceptional versatility. Available in rectangular, circular, and strip
configurations for countless applications, many of our connectors meet
or exceed applicable requirements of the MIL-DTL-83513 specification.
Rack and Panel Connectors
Initially pioneered by Cannon during the 1930s, ITT's Interconnect Solutions
is the world leader in rack and panel connectors, offering unmatched
variety of shell configurations and insert arrangements, materials, plating,
and contact options. Many of our standard and custom designs meet the
stringent requirements of ARINC 600, ARINC 404 (MIL-C-81659), and
MIL-DTL-83733 standards.
Trident
Cannon’s Trident Connector System is a versatile range of electrical
connectors based on a standard contact design. These contacts are fully
interchangeable throughout the Trident Connector System. The connector
options include low cost rectangular, rack and panel, industrial grade
circulars, harsh environment circulars and shielded circulars.
Transportation
The ITT's Interconnect Solutions includes sealed circular and rectangular connectors in
metal or plastic shells. These configurations include board to cable or cable to cable /
bulkhead applications. Both signal and power contacts can be combined in various
layouts. All product lines within the Transportation segment offer very low contact
resistance providing maximum signal integrity.
ITT's Interconnect Solutions is an international manufacturer and supplier of connectors including circular, rectangular, fiber optic, RF, power and
high voltage, audio, PMCIA, Compact Flash Card, enclosures, cable assemblies, and application specific custom solutions. The Interconnect
Solutions portfolio includes the brands Cannon, VEAM, and BIW Connector Systems. As a worldwide leader in connector technology for nearly a
century, ITT offers one of the broadest product offerings, six sigma manufacturing capability, Value Based Product Development with exceptional
engineering capability, and an extensive sales, distribution, and customer support network.
www.ittcannon.com
35
Connect with your ITT Interconnect Solutions representative
today or visit us at www.ittcannnon.com
Connect with the experts
ITT Interconnect Solutions’ Cannon brand is a world leader in the design
and manufacture of highly engineered connector solutions for multiple
end markets.
North America
56 Technology Drive
Irvine, CA 92618
Phone: 1.800.854.3208
Europe
Italy
Corso Europa 41/43
I - 20020 Lainate (MI) Italy
Phone: +39.02938721
Germany
Cannonstrasse 1
D – 71384 Weinstadt, Germany
Phone: +49.7151.699.0
The “ITT Engineered Blocks“ symbol, “Engineered for life”, “ITT” and “Cannon“ are registered trademarks of ITT Corporation.
Specification and other data are based on information available at the time of printing, and are subject to change without notice.
Asia
Tuopandun Industrial Area, Jinda Cheng,
Xiner Village, Shajing Town, Boan District,
Shenzhen City, Guangdong Province, China 518215
Phone: +86.755.2726.7888
© 2016 ITT Corporation
ITT Cannon KPx Cat 201602