CBP865 Central and Monitoring Station Alarm Units ALARM DEVICE MANUFACTURING CO., A Division of Pittway Corporation, Syosset, NY 11791 CBP865 Model 7830RCN long-range radio alarm transmission unit, suitable for use with this manufacturer's burglar alarm system control units, Input: 16.5 V ac, 40 VA, 60 Hz; RF output: 2 W maximum. Provides line security level 2 when used with the Model 659EN line monitor device. Model 7830RTCN long-range radio alarm receiving module, suitable for use with line-card module 685-5N and digital burglar alarm communication receiver, Model 685, Input: 16.5 V ac, 40 VA, 60 Hz. Model 7835C cellular control channel signal transceiver unit, suitable for use with this manufacturer's burglar alarm system control units, Input: 16.5 V ac, 40 VA, 60 Hz, provided from a Class 2, plug-in transformer. Provides line security Level 1 when connected as a backup signal channel to a regular PSTN telephone line. Marking: ULC label together with listee's name, model designation, electrical rating, and Industry Canada number. BP1143 Central and Monitoring Station Alarm Units ALARM DEVICE MANUFACTURING CO., A Division of Pittway Corporation, Syosset, NY 11791 CBP688/BP1143 Combination household burglar/fire, local burglar alarm and subscribers' unit burglar system consisting of: Model Vista 128 control unit with Model 6139 annunciator keypad, Input: 16.5 V ac, 40 VA sec. (powered from a Class 2, limited energy transformer). Central and monitoring station burglar alarm system control units, Models Vista 20CN, Vista 20SECN and Vista 20ADTCN, Input: 16.5 V ac, 25 VA from a Class 2, limited energy transformer. Model 4293 SN Serialized Interface Module, Input: 7-11 V dc, 2 mA, Model 4101 SN Single Zone Expander Module, Input: 7-11 V dc, 7 mA, Model 4190 SN Dual Zone Expander Module, Input: 7-11 V dc, 2 mA. Marking: ULC label together with listee's name, model designation and electrical rating. ML574 Contacts and Switches ALARM DEVICE MANUFACTURING CO., A Division of Pittway Corporation, Syosset, NY 11791 ML574 Magnetically actuated contacts, Cat. Nos. 39, 39W, 39BR, 39-2, 39W-2, 39BR-2, 7939, 7939-1, 7939-2, PR-20439 and WA7939. Contact Rating: 30 V ac/dc, 50 mA. Magnetically actuated contacts, Models 945T-BR, 945T-WH and 945T-GY. Contact Rating: 30 V ac/dc, 100 mA. Models 940, 941, 943, 944, 944-2, 944-SP, 944-T, 944W, 944CE, 945, 947, 947-75, 949, 950, 950W, 951, 955, 956, 956-2, 957, 957W, 959, 959-2, 960, 960-2, 7940, 7945, PR-3814, PR-20411, PR-20412, PR-20421, PR-20422, PR-20443, PR-20445, PR-20451, PRO-51SP, PAL, PAL-T and PAL-CE, Input: 28 V dc, 100 mA. Model 958, Input: 28 V dc, 500 mA; Model 958-2, Input: 28 V dc, 200 mA; Model 4191SN, Input: 8-11 V dc, 0.5 mA; and Models 4939SN, 4959SN and 4944SN, Input: 12 V dc, 1.0 mA. All of the above with suffix letters BR, WH or GY to designate colour of enclosure. Marking: ULC Integral Marker together with "ADEMCO" in an oval, or "Alarm Device Mfg. Co.", or "Ademco", or Model Number only. ML445 Intrusion Detection Units ALARM DEVICE MANUFACTURING CO., A Division of Pittway Corporation, Syosset, NY 11791 ML445 Infrared Detection Units: Models 998-EX and 998EXPI, Input: 12 V dc, 17 mA. Model 1878EX, Input: 12 V dc, 22 mA. Models 998-MX, 4275-EX and 4278EX-SN, Input: 8-11 V P/P from control unit polling loop, 4 mA in alarm condition (LED enabled). Dual Infrared and Microwave Intrusion Detection: Models Quest 2135 and Quest 2160, Electrical rating: 9-15 V dc, 16 mA at 12 V dc. Dual Infrared and Microwave Intrusion Detection Units: Models Quest 2220, 2220C, 2235, 2235C, 2260 and 2260C, Input: 9-16 V dc, 20 mA at 12 V dc. Glass Break Detection Units: Model 5853, RF Type, Input: 3.0 V dc, battery operated. Intended for use with a listed, compatible Household Burglar Alarm System Control Unit. Marking: ULC Integral Marker consisting of ULC in a circle. BP511 Local Alarm Units ALARM DEVICE MANUFACTURING CO., A Division of Pittway Corporation., Syosset, NY 11791 CBP26/BP511 Combination household burglar/fire, local burglar alarm and subscribers' unit burglar system consisting of: Model Vista 128 control unit with Model 6139 annunciator keypad, Input: 120/16.5 V ac, 40 VA sec. (powered from a Class 2, limited energy transformer). Local burglar alarm housing unit and bell, Model AB12M, Input: 9-15 V dc, 35-90 mA. Marking: ULC label together with listee's name, model designation and electrical rating. S1632 Household Burglar Alarm System Units ALARM DEVICE MANUFACTURING CO., A Division of Pittway Corporation, Syosset, NY 11791 CBP444/S1632 Combination household fire warning and burglar alarm system consisting of: Model VISTA 20CN control unit, Input: 16.5 V ac, 25 VA (powered from a Class 2, limited energy transformer); Model 6139CN** annunciator keypad, Input: 9.6-13.8 V dc, 600 mA; and Model 5882LCN RF receiver, Input: 12 V dc, 50 mA. Household burglar alarm system consisting of: Model VISTA 10EX or VISTA 10ADTCN or 4110XMP control unit, Input: 16.5 V ac, 25 VA (powered from a Class 2, limited energy transformer); Model 6139CN** annunciator keypad; and Models 5882LCN or 5882NCN RF receiver. Models VISTA 10EX-SE and First Alert Model FA120C-CN control units, Input: 16.5 V ac, 25 VA (powered from a Class 2, limited energy transformer); with respective annunciator keypads, Models 6128CN**, FA210KP-CN** and 6128ADTFR; and Model 5882LCN or 5882NCN RF receiver. Combination household burglar/fire, local burglar alarm and subscribers' unit burglar system consisting of Model Vista 128 control unit with Model 6139** annunciator keypad, Input: 120/16.5 V ac, 40 VA (powered from a Class 2, limited energy transformer). ** Keypad models employ a two digit alpha prefix, XX, and a five digit alpha numeric suffix, YYYYY. Combination household fire and burglar alarm system units, Models FA142C, FA147C and FA162C, with or without suffix LT, Input: 16.5 V ac, 25 VA (powered from a Class 2, limited energy transformer). Used with keypad models FA210KP-CN and FA250KP-CN. Combination household fire and burglar alarm system control unit, Models VISTA 20SECN and VISTA 20ADTCN, Input: 16.5 V ac, 25 VA from a Class 2, limited energy transformer. Combination household fire and burglar alarm system unit, Model FA1600CA, Input 16.5 V ac, 40 VA. Used with keypad, Model FA560KP-CN. Marking: ULC label together with listee's name, model designation, electrical rating and DOC certificate number. S696 Fire Alarm Devices, Heat Actuated, For Household Use ALARM DEVICE MANUFACTURING CO., A Division of Pittway Corporation, Syosset, NY 11791 CS985/S696 Combination fixed-temperature and rate-of-rise heat detector, Model 5809, with RF transmitter energized by a single lithium battery CR123A, 3 volt. Temperature rating 57°C. Intended for use with compatible RF signal receiving modules. Marking: ULC label together with listee's name, model designation, temperature rating, information on replacement of unit and information relating to limited use. S1428 Smoke-Alarms and Accessories ALARM DEVICE MANUFACTURING CO., A Division of Pittway Corporation, Syosset, NY 11791 CS727/S1428 Photoelectric Type – Single Station – Model 5806CN with RF transmitter, energized by 2 Duracell MN1604, 9 V dc alkaline batteries. For use with VISTA-20CN control unit. Marking: ULC label together with listee's name, model designation, DOC certificate number, and electrical rating. ML577 Smoke-Alarm Components ALARM DEVICE MANUFACTURING CO., Syosset, NY 11791 U.S.A. ML577 Smoke-alarm components, Model 5808LSTA. Marking: Listee's identification marking containing at least the listee's name, model number, and ULC designation "CRP". UTOUC.S1632 Household Fire Warning System Units ALARM DEVICE MANUFACTURING CO., A Division of Pittway Corporation, Syosset, NY 11791 CS551/S1632 Combination household fire warning and burglar alarm system consisting of: Model VISTA 20CN control unit, Input: 16.5 V ac, 25 VA (powered from a Class 2, limited energy transformer); Model 6139** annunciator keypad, Input: 9.6-13.8 V dc, 600 mA; Model 6128** keypad, Input: 12 V dc, 30 mA; and Model 5882L RF receiver, Input: 12 V dc, 50 mA. Combination household burglar/fire, local burglar alarm and subscribers' unit burglar system consisting of Model Vista 128 control unit with Model 6139** annunciator keypad, Input: 120/16.5 V ac, 40 VA (powered from a Class 2, limited energy transformer). ** Keypad models employ a two digit alpha prefix, XX, and a five digit alpha numeric suffix, YYYYY. Combination household fire and burglar alarm system units, Models FA142C, FA147C and FA162C, with or without suffix LT, Input: 16.5 V ac, 25 VA (powered from a Class 2, limited energy transformer). Used with keypad models FA210KP-CN and FA250KP-CN. Combination household fire and burglar alarm system control units, Models VISTA 20SECN and VISTA 20ADTCN, Input: 16.5 V ac, 25 VA from a Class 2, limited energy transformer. Combination household fire and burglar alarm system unit, Model FA1600CA, Input 16.5 V ac, 40 VA. Used with keypad Model FA560KP-CN. Marking: ULC label together with listee's name, model designation, electrical rating and DOC certificate number. ML580 Central Station System Units, Fire Alarm ALARM DEVICE MANUFACTURING CO., A Division of Pittway Corporation, Syosset, NY 11791 ML580 Fire Protective Signalling System Control Units: Model 4293 SN Serialized Interface Module, Input: 7-11 V dc, 2 mA, Model 4101 SN Single Zone Expander Module, Input: 7-11 V dc, 7 mA, Model 4190 SN Dual Zone Expander Module, Input: 7-11 V dc, 2 mA. Model MX8000 digital alarm receiver, consisting of sub assemblies MX-8000-CPU Module, MX8000-LC1 line card, MX8000LC3 line card and MX8000-LRR, Input: 120 V ac, 60 Hz, 100 VA or 240 V ac, 50 Hz, 100 VA. Marking: ULC label together with listee's name, model designation and electrical rating. S789 Miscellaneous Fire Alarm Devices ALARM DEVICE MANUFACTURING CO., A Division of Pittway Corporation, Syosset, NY 11791 CS971/S789 Model 7835CF cellular control channel signal transceiver unit, suitable for use with Model F128-FB fire alarm signal monitoring control unit, Input: 16.5 V ac, 40 VA, 60 Hz. Provided from a Class 2, plug-in transformer mounted inside an approved electrical box which is connected to the metal enclosure by means of electrical conduit. Provides a secondary means of transmitting fire alarm signals when control unit is also connected to the regular PSTN telephone line. Marking: ULC label together with listee's name, model designation, and electrical rating.