X

SC100 Series
SEISMIC VIBRATION SENSORS
Honeywell’s SC100 Series Seismic Vibration Sensors were
designed to protect high-value and high-risk assets in
financial, retail and other applications.
false alarm immunity than traditional shock sensors, which
often lack the ability to discriminate between ambient
vibration and real attacks.
The SC100 model detects vibrations arising from attempts
to disturb solid structures including fixed ATMs, bank
vaults, safes and doors. The SC105 was designed to
safeguard freestanding objects like standalone ATMs, gun
cases, file cabinets, vending and ticket machines and
more. Both models can be installed in new or existing
security systems and offer a higher level of protection and
The SC100 Series contain several unique features that
reduce installation time and costs—including a Universal
setting that lets dealers choose between safes and vaults
with the change of a dip switch, integrated end-of-line
(EOL) resistors that improve connectivity to the control
panel, a built-in diagnostic tool and a compact size that
enables placement inside small areas.
FEATURES
• Detects attacks on
Bank vault doors, ATMs, night deposit
safes, strong room vaults, modular
vaults, vending machines, freestanding
safes, hatches, gates, chests and other
objects with a solid structure
• Detects attacks from
- Heavy strokes or gross attacks from
sledgehammers or explosives
- Repeated knocks from hammers
and chisels
- Drilling, mechanical cutting, acetylene
torches, thermal cutting, water-cooled
diamond drills, water jet cutting tools,
hydraulic jacks (SC100 only)
• Compact size
Smallest available on market so fits
easier when space is limited
• Universal (ATM and vault)
The SC100 can also be used for ATMs
and night deposit safes by the simple
change of a dip switch. No separate
sensors are required.
• Drilling shield (standard)
Protects electronics inside against
sabotage
• Extended temperature
Allows operation in extreme temperature
conditions (-40° F to 158° F)
• Remote sensitivity reduction input
Option to reduce sensor sensitivity
remotely during maintenance on ATMs,
thereby reducing false alarms
• Selectable sensitivity
Four different sensitivity settings adapt
to required range and environmental
conditions
• Multi-compatible mounting plate fits
on pre-fab holes
Fits on most pre-drilled mounting holes
from other seismic sensors, preventing
time consuming drilling/threading. The
same mounting plate can be used for
mounting on concrete and welding
on steel.
• Remote testing and test transmitters
Input to remotely start functional test
with help of SC113 (Internal Test
Transmitter) or SC115 (External Test
Transmitter). If no test transmitter is
available, it is possible to test internal
electronics with this test.
• Integrated End-of-Line
(EOL) resistors
EOL resistors for alarm as well as
tamper loop are already incorporated,
saving installation time and reducing
service calls
• Integrated temperature alarm
The SC100 and SC105 will alarm if
the temperature exceeds 185° F.
Additionally the SC100 version alarms
when temperature rises faster than 6° F
per minute.
• Diagnostic LED
Built-in tool easily selects correct
sensitivity; no time consuming external
tools required
• Available accessories
Mounting plate, keyhole protection kit,
day/night kit, Internal Test Transmitter,
armed cable and External Test
Transmitter. This range of accessories
allows the SC100 and SC105 Seismic
Sensors to be mounted in a wide range
of applications.
• Listed to UL639
• Listed to ULC-S306
SC100 Series
SEISMIC SENSORS
Specifications
SC100
Highly sensitive to all known
attacks while rejecting known false
alarm sources by innovative filters
and firmware
Alarm Algorithm
Alarm Outputs
Sabotage Protection
Inputs
Solid State Relay (Change Over)
Open Collector
Alarm Hold Time
Pry-off and Cover Switch
Low Supply Voltage Alarm
Temperature Alarm
Internal Functional Alarm
Remote Test
Environmental
Conditions
Housing
SC110
Similar to the SC100, but adjusted for
noisy environments such as public
areas where ATMs may be located
30VDC/100 mA; Type C
30 VDC/100 mA; Type A
Active low during alarm
Approx. 2.5 secs
30 VDC/100 mA
< 7 VDC
185° F, 23° F, 41° F
Stainless steel drill shield
Active low 1.5 VDC, test duration < 0.5 sec
Active low 1.5 VDC, test duration < 0.5 sec
Sensitivity reduction to 12.5 %
Reduced Sensitivity Input
Installation Tool
SC100 series accessories
SC105
8 – 16VDC, nominal 12VDC
Typical 3 mA @ 12VDC
4 levels by DIP Switches
by DIP switch
N/A
N/A
by DIP switch
For maintenance & Service: Active low (<1.5 VDC)
16.4'
9.8'
Power Requirements Supply Voltage
Current Consumption
Adjustable Sensitivity
Sensitivity
ATMs/Vault Selection
Delayed Triggering
Reduced Sensitivity Input
Detection Radius
SC111
SC112
A noise and alarm indicator is incorporated to support sensitivity setting.
Maximum Humidity
95% RH (non-condensing)
Operating Temperature
-40° F – 158° F
Storage Temperature
-58° F – 158° F
Environmental Class (VdS)
III
Housing Protection Category
IP43
Dimensions
3.15" H x 2.36" W x .83" D
Chassis and Cover
Die-cast metal
Color
RAL7035 (light gray)
Weight
.5 lbs.
SC113
Honeywell reserves the right to alter the specification of products without notice.
Applications
SC100
Vault Doors

ATMs
Night Deposit Safes
Strong Room Vaults
Modular Vaults
Freestanding Safes
Hatches
Gates
Chests
Lobby ATMs
Filing Cabinets
Containers
Vending Machines
Ticket Machines








SC114
SC105
DIP-switches
Diagnostic/
Alarm LED
Tamper switch
SC115







Open collector
output setting
EOL resistor
jumpers
SC111 or SC112
connector for
accessories
Terminal block
ORDERING
SC100
SC105
SC110
SC111
SC112
SC113 Test transmitter
connector
Seismic Vibration Sensor (Safes/Vaults)
Seismic Vibration Sensor (ATMs)
Mounting Plate
Movable Mounting Kit
Keyhole Protection Kit
SC113
SC114
SC115
SC116
SC117
SC118
Internal Test Transmitter
5.9' Armed Cable Kit (eight wires)
External Test Transmitter
Wall Recess Mounting Kit
Floor Recess Mouting Kit
Spacer for SC112
For more information:
www.honeywell.com/security
Automation and Control Solutions
Honeywell Security Products Americas
2 Corporate Center Dr. Suite 100
P.O. Box 9040
Melville, NY 11747
1.800.467.5875
www.honeywell.com
SC116
SC117
SC118
L/SC100D/D