For more information, please visit the product page. date 06/26/2015 page 1 of 8 SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER FEATURES • • • • • • • • • • 1 W isolated output smaller package single/dual unregulated outputs 3,000 Vdc isolation short circuit protection extended temperature range (-40~105°C) antistatic protection up to 8kV UL 60950-1 approval high efficiency at light load efficiency up to 82% MODEL input voltage output voltage output current output power ripple and noise2 efficiency typ (Vdc) range (Vdc) (Vdc) min (mA) max (mA) max (W) typ (mVp-p) typ (%) PES1-S3-S3-M 3.3 2.97~3.63 3.3 30 303 1 60 69 PES1-S3-S5-M 3.3 2.97~3.63 5 20 200 1 60 74 PES1-S5-S3-M1 5 4.5~5.5 3.3 30 303 1 60 72 1 PES1-S5-S5-M 5 4.5~5.5 5 20 200 1 60 80 PES1-S5-S9-M1 5 4.5~5.5 9 12 111 1 60 80 1 PES1-S5-S12-M 5 4.5~5.5 12 9 84 1 60 80 PES1-S5-S15-M1 5 4.5~5.5 15 7 67 1 60 80 PES1-S5-S24-M 5 4.5~5.5 24 4 42 1 60 80 PES1-S5-D5-M 5 4.5~5.5 ±5 ±10 ±100 1 60 80 PES1-S5-D9-M 5 4.5~5.5 ±9 ±6 ±56 1 60 80 PES1-S5-D12-M 5 4.5~5.5 ±12 ±5 ±42 1 60 79 PES1-S5-D15-M 5 4.5~5.5 ±15 ±3 ±33 1 60 81 PES1-S5-D24-M 5 4.5~5.5 ±24 ±2 ±21 1 60 81 1 PES1-S12-S3-M 12 10.8~13.2 3.3 30 303 1 60 72 PES1-S12-S5-M1 12 10.8~13.2 5 20 200 1 60 80 1 1 PES1-S12-S9-M 12 10.8~13.2 9 12 111 1 60 80 1 PES1-S12-S12-M 12 10.8~13.2 12 9 84 1 60 80 PES1-S12-S15-M1 12 10.8~13.2 15 7 67 1 60 80 PES1-S12-D5-M 12 10.8~13.2 ±5 ±10 ±100 1 60 80 PES1-S12-D9-M 12 10.8~13.2 ±9 ±6 ±56 1 60 80 PES1-S12-D12-M 12 10.8~13.2 ±12 ±5 ±42 1 60 81 PES1-S12-D15-M 12 10.8~13.2 ±15 ±3 ±33 1 60 81 PES1-S12-D24-M 12 10.8~13.2 ±24 ±2 ±21 1 60 81 PES1-S15-S15-M 15 13.5~16.5 15 7 67 1 60 80 1 PES1-S24-S5-M 24 21.6~26.4 5 20 200 1 60 80 PES1-S24-S9-M1 24 21.6~26.4 9 12 111 1 60 80 24 21.6~26.4 15 7 67 1 60 80 1 PES1-S24-S15-M 1 Notes: 1. UL approved 2. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output. cui.com For more information, please visit the product page. CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER MODEL (CONTINUED) input voltage date 06/26/2015 │ page 2 of 8 output voltage output current ripple and noise2 efficiency max (mA) max (W) typ (mVp-p) typ (%) typ (Vdc) range (Vdc) PES1-S24-S24-M1 24 21.6~26.4 24 4 42 1 60 80 PES1-S24-D5-M 24 21.6~26.4 ±5 ±10 ±100 1 60 80 PES1-S24-D9-M 24 21.6~26.4 ±9 ±6 ±56 1 60 80 PES1-S24-D12-M 24 21.6~26.4 ±12 ±5 ±42 1 60 81 PES1-S24-D15-M 24 21.6~26.4 ±15 ±3 ±33 1 60 82 PES1-S24-D24-M 24 21.6~26.4 ±24 ±2 ±21 1 60 76 Notes: min (mA) output power (Vdc) 1. UL approved 2. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output. PART NUMBER KEY PES1 - SXX - XXX - M - X Base Number Input Voltage Output S = single D = dual Output Voltage Packaging Style "blank" = tube TR = tape & reel INPUT parameter conditions/description min typ max units operating input voltage 3.3 Vdc input models 5 Vdc input models 12 Vdc input models 15 Vdc input models 24 Vdc input models 2.97 4.5 10.8 13.5 21.6 3.3 5 12 15 24 3.63 5.5 13.2 16.5 26.4 Vdc Vdc Vdc Vdc Vdc surge voltage for maximum of 1 second 3.3 Vdc input models 5 Vdc input models 12 Vdc input models 15 Vdc input models 24 Vdc input models -0.7 -0.7 -0.7 -0.7 -0.7 5 9 18 21 30 Vdc Vdc Vdc Vdc Vdc filter capacitance filter max units ±1.5 ±1.2 % % OUTPUT parameter conditions/description line regulation for Vin change of 1% 3.3 Vdc output models all other models min load regulation measured from 10% load to full load 3.3 Vdc output models 5 Vdc output models 9 Vdc output models 12 Vdc output models 15 Vdc output models 24 Vdc output models voltage accuracy see tolerance envelope curve switching frequency 100% load, nominal input voltage temperature coefficient 100% load typ 18 12 9 8 7 6 % % % % % % 100 kHz ±0.03 cui.com %/°C For more information, please visit the product page. CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER date 06/26/2015 │ page 3 of 8 PROTECTIONS parameter conditions/description short circuit protection1 PES1-S5-S/D24-M and 24 Vdc input models all other models: automatic recovery Note: min typ max units 1 s max units 1. The supply voltage must be discontinued at the end of the short circuit duration SAFETY AND COMPLIANCE parameter conditions/description isolation voltage input to output for 1 minute at 1 mA max. 3,000 Vdc isolation resistance input to output at 500 Vdc 1,000 MΩ safety approvals UL 60950-1 conducted emissions CISPR22/EN55022 class B (external circuit required, see Figure 1) radiated emissions CISPR22/EN55022 class B (external circuit required, see Figure 1) ESD IEC/EN61000-4-2, class B, contact ± 8kV for single outputs IEC/EN61000-4-2, class B, contact ± 6kV for dual outputs MTBF as per MIL-HDBK-217F @ 25°C 2 RoHS Note: min typ 3,500,000 hours 2011/65/EU 2. See specific models noted on page 1 & 2. ENVIRONMENTAL parameter conditions/description min operating temperature see derating curve storage temperature storage humidity non-condensing temperature rise at full load, Ta = 25°C typ max units -40 105 °C -55 125 °C 95 % 25 °C SOLDERABILITY parameter conditions/description max units hand soldering 1.5 mm from case for 10 seconds min 300 °C reflow soldering see reflow soldering profile 245 °C 250 245 Peak.Temp 245ć(Max.) 217 Tem peratur e (đ) 200 60 Sec Max (> 217ć) 150 100 50 0 typ Ti me (sec.) cui.com For more information, please visit the product page. CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER date 06/26/2015 │ page 4 of 8 MECHANICAL parameter conditions/description dimensions single output models: 12.70 x 8.30 x 7.25 dual output models: 15.24 x 8.30 x 7.25 min case material epoxy resin (UL94-V0) weight single output models dual output models typ max units mm mm 1.6 2.0 g g MECHANICAL DRAWING SINGLE OUTPUT MODELS rArC units: mm[inch] tolerance: ±0.25[±0.010] pin section tolerance: ±0.10[±0.004] 2 Vin 4 0V 5 +Vo 8 NC $ AC GND d q 1 AC Function AC AC :UV<OK] AC AC NC: No Connection $ AC ,XUTZ<OK] 8OMNZ<OK] AC AC AC AC 4UZK -XOJSS :UV<OK] cui.com AC PIN PIN CONNECTIONS AC AC For more information, please visit the product page. CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER date 06/26/2015 │ page 5 of 8 MECHANICAL DRAWING (CONTINUED) DUAL OUTPUT MODELS GND 2 Vin 4 0V 5 -Vo 7 +Vo 10 NC 0.60 [0.024] $ ±5° 1 11.20 [0.441] Function 8.30 [0.327] PIN CONNECTIONS PIN 0.25 [0.010] 15.24±0.50 [0.600±0.020] units: mm[inch] tolerance: ±0.25[±0.010] pin section tolerance: ±0.10[±0.004] 2.54 [0.100] 10.16 [0.400] NC: No Connection 7.00 [0.276] 7.25 [0.285] Top View $ 0.88 [0.035] 0.10 Front View 1 7 4 2 5 1.00 [0.039] 2.54 [0.100] 10.16 [0.400] Note : Grid 2.54*2.54mm Top View cui.com 12.20 [0.480] 2.10 [0.083] 10 Right View For more information, please visit the product page. CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER date 06/26/2015 │ page 6 of 8 DERATING CURVES Tolerance Envelope Curve (3.3 Vdc single output only) 5 Typ ic al L oad 0 10 Output Voltage Accuracy (%) Output Voltage Accuracy (%) 10 1.0 Rated Output Voltage Lin e -5 -7.5 -10 -15 -15 10 20 40 60 80 Tolerance Envelope Curve (all other models) Typic al 5 Line 2.5 Rated Output Voltage -2.5 -5 -7.5 -10 -15 10 100 Load 0 20 40 60 80 100 Output Current Percentage (%) (Nominal Input Voltage) Output Current Percentage (%) (Nominal Input Voltage) Temperature Derating Curve 100 Load (%) 80 60 Safe operating area 40 20 -40 -20 0 20 40 60 80 100 105 Ambient Temperature (°C) EMC RECOMMENDED CIRCUIT Figure 1 LDM Vin C1 GND Table 1 +Vo Vin DC/DC GND Cout LOAD Recommended external circuit components Single Outputs 0V LDM Vin Vin +Vo Note: C1 GND DC/DC Cout LOAD Dual Outputs - 0V GND CY cui.com Vin (Vdc) C1 LDM 3.3 4.7μF/50V 6.8μH 5 4.7μF/50V 6.8μH 12 4.7μF/50V 6.8μH 15 4.7μF/50V 6.8μH 24 4.7μF/50V 6.8μH 1. See Table 2 for Cout values. 2. CY: 1nF/3kV for 24 Vdc input dual output models, PES1-S5-D24-M, and PES1-S12-D24-M only For more information, please visit the product page. CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER date 06/26/2015 │ page 7 of 8 APPLICATION NOTES 1. Output load requirement To ensure this module can operate efficiently and reliably, the minimum output load may not be less than 10% of the full load during operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load. 2. Overload Protection Under normal operating conditions, the output circuit of this product has no protection against overload. The simplest method to add this is to add a circuit breaker to the circuit. 3. Recommended circuit If you want to further decrease the input/output ripple, you can increase the capacitance accordingly or choose capacitors with low ESR(see Figure 2 & Table 2). However, the capacitance of the output filter capacitor must be appropriate. If the capacitance is too high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the maximum capacitance must be less than the maximum capacitive load (see Table 3). Figure 2 Single Output Dual O ut put +Vo Vin GND Cout DC DC Cin Vin GND 0V DC DC Cin Table 2 Cout Cout +Vo 0V -Vo Table 3 Vin (Vdc) Cin (µF) Single Vo (Vdc) Cout (µF) Dual Vo (Vdc) Cout (µF) Single Vout (Vdc) Max. Capacitive Load (μF) Dual Vout (Vdc) Max. Capacitive Load1 (μF) 3.3 4.7 3.3 10 -- -- 3.3 220 -- -- 5 100 5 4.7 5 10 ±5 4.7 5 220 -- -- 9 4.7 ±9 2.2 9 220 9 100 12 2.2 12 2.2 ±12 1 12 220 12 100 15 2.2 15 1 ±15 1 15 220 15 100 24 1 24 0.47 ±24 0.47 24 220 24 100 Note: Note: 1. 2. 3. 4. 1. For each output. Operation under minimum load will not damage the converter; however, they may not meet all specifications listed. Max. capacitive load tested at input voltage range and full load. It is recommended to use either ceramic capacitors or electrolytic capacitors on the input and the output. Using tantalum capacitors may increase the risk of failure. All specifications measured at: Ta=25°C, humidity<75%, nominal input voltage and rated output load, unless otherwise specified. cui.com For more information, please visit the product page. CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER date 06/26/2015 │ page 8 of 8 REVISION HISTORY rev. description date 1.0 initial release 03/19/2013 1.01 added models, updated spec 04/04/2014 1.02 added UL approval to some models 10/21/2014 updated tolerance envelope curves 06/26/2015 1.03 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.