For more information, please visit the product page. date 12/02/2014 page 1 of 8 SERIES: PCM-400 │ DESCRIPTION: AC-DC POWER SUPPLY FEATURES • • • • • • up to 400 W continuous power universal input (90~264 Vac) active power factor correction peak power of 700W for 500µs duration (single output models only) built-in remote ON/OFF, power good, & fan fail alarm options over voltage, short circuit, over current, and over temperature protection • efficiency up to 87% MODEL preset output voltage customizable output range7 output current output power ripple and noise8,9 efficiency (Vdc) (Vdc) max (forced air) (A) max (convection) (A) max (W) max (mVp-p) typ (%) PCM-400-121,2 12 10~13.8 33.33 18.33 400 120 85 PCM-400-151,2 15 14~15.5 26.67 14.67 400 150 85 1,2 PCM-400-18 18 16~20 22.22 12.22 400 180 85 PCM-400-241,2 24 21~26 16.67 9.17 400 240 87 1,2 PCM-400-28 28 27~34 14.29 7.86 400 280 85 PCM-400-361,2 36 35~42 11.11 6.11 400 360 87 1,2 PCM-400-48 48 43~50 8.33 4.58 400 480 87 PCM-400-541,2 54 51~60 7.41 4.07 400 540 87 PCM-400-D05123,4 Vo1 Vo2 5 12 N/A 30 20.83 15 13.33 320 50 120 87 PCM-400-D05243,4 Vo1 Vo2 5 24 N/A 30 10.42 15 6.67 320 50 240 87 PCM-400-D05483,4 Vo1 Vo2 5 48 N/A 30 5.21 15 3.33 320 50 480 87 PCM-400-D12245,6 Vo1 Vo2 12 24 N/A 20.83 10.42 12.5 8.33 400 120 240 87 Notes: 1. 2. 3. 4. 5. 6. 7. 8. 9. For U-frame models, the maximum output power is 400W with a minimum of 27 CFM forced air, 220 W maximum with convection cooling. For CNF models, the maximum output is 220 W with convection cooling. For U-frame models, the total combined output power is 320W with a minimum of 27 CFM forced air, 180 W maximum with convection cooling. For CNF models, the maximum output is 180 W with convection cooling. For U-frame models, the total combined output power is 400W with a minimum of 27 CFM forced air, 200 W maximum with convection cooling. For CNF models, the maximum output is 200 W with convection cooling. Output can be custom set within range. Measured at 10 kHz ~ 20 MHz bandwidth, with a 22 µF electrolytic and 0.1 µF ceramic capacitor on the output. 1% minimum load is required to maintain ripple and regulation (10% for dual output models). PART NUMBER KEY PCM-400 - X XX - XXX - X Base Number Output “blank” = Single D = Dual Output Voltage cui.com Chassis Input/Output Connectors U = U-frame “blank” = terminal block CNF = enclosed 1 = header CF = enclosed with top fan CFS = enclosed with rear fan For more information, please visit the product page. CUI Inc │ SERIES: PCM-400 │ DESCRIPTION: AC-DC POWER SUPPLY date 12/02/2014 page 2 of 8 INPUT parameter conditions/description min voltage typ 90 frequency 47 current at 90 Vac, full load inrush current at 115 Vac, cold start at 230 Vac, cold start leakage current at 120 Vac at 240 Vac power factor correction at 230 Vac, full load remote ON/OFF designated as INH on Pin 4 of CN1, requires a low signal to inhibit output input fuse T8 A/250 V on the input max units 264 Vac 63 Hz 8 A 35 70 A A 300 500 μA μA max units 0.9 OUTPUT parameter conditions/description total regulation single output models dual output models transient response returns to within 1% in <2.5 ms for a 50% load change and the peak transient does not exceed 5% start-up time at 120 Vac hold-up time at 120 Vac, 75% load adjustability1 built in trim pot ±5 % PFC 68 kHz 55 50 kHz kHz switching frequency PWM min typ ±1 ±5 1.5 16 all single output models & PCM-400-D1224 all other dual output models s ms fan drive 12 Vdc/300 mA for external fan fan fail (FF) Designated as FF on Pin 3 of CN1, open collector output rated for 15Vdc/5mA max sink current. It goes high when a fan failure is detected. power good (PG) Designated as PG on CN1, TTL high 100~500 ms after DC regulation. It goes low at least 1 ms before loss of regulation. power supply on green LED designated as LED1 on the PCB Note: % % 1. U-Frame versions only PROTECTIONS parameter conditions/description short circuit protection auto restart min over current protection auto restart over voltage protection output latches, must recycle ac input to reset over temperature protection auto restart typ 110 max units 140 % 130 % 105 110 115 °C min typ max units SAFETY & COMPLIANCE parameter conditions/description isolation voltage input to output, for 3 sec. input to core, for 3 sec. input to chassis (10 mA AC cut-off current), for 3 sec. safety approvals UL/cUL, TUV safety standards UL 60950-1, EN 60950-1 EMI/EMC2 EN 55022 Class B (conducted/radiated), EN 61000-3-(2,3), EN 55024, IEC 61000-4-(2, 3, 4, 5, 6, 11), CE MTBF as per MIL-HDBK-217F at 30°C RoHS 2011/65/EU Note: 3,000 1,500 1,500 100,000 Vac Vac Vac hrs 2. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. cui.com For more information, please visit the product page. CUI Inc │ SERIES: PCM-400 │ DESCRIPTION: AC-DC POWER SUPPLY date 12/02/2014 page 3 of 8 ENVIRONMENTAL parameter conditions/description operating temperature see derating curve min storage temperature max units 0 typ 70 °C -20 85 °C operating humidity non-condensing 5 90 % storage humidity non-condensing 5 95 % vibration at 5~50 Hz, along the X, Y, and Z axis ±0.75 G DERATING CURVE 100 Load (%) 80 60 50 Safe operating area 40 20 0 0 10 20 30 40 50 60 70 Ambient Temperature (°C) MECHANICAL parameter conditions/description min dimensions U-frame models: 152.40 x 101.60 x 38.10 CNF models: 152.40 x 101.60 x 39.90 CF models: 152.40 x 101.60 x 54.45 CFS models: 177.80 x 101.60 x 40.64 weight U-frame models CNF models CF models CFS models typ units mm mm mm mm 600 650 800 750 cui.com max g g g g For more information, please visit the product page. CUI Inc │ SERIES: PCM-400 │ DESCRIPTION: AC-DC POWER SUPPLY date 12/02/2014 MECHANICAL DRAWING - SINGLE OUTPUT MODELS U-FRAME units: mm[inch] CN1 PIN Function 1 PG 2 RTN 3 FF 4 INH CN2 Terminal Block Header PIN Function PIN Function 1~2 +Vo 1~5 +Vo 3~4 -Vo 6~10 -Vo 5 GND 12 GND 6 N 14 N 7 L 16 L Fan1 PIN Function 1 +FAN 2 -FAN CNF units: mm[inch] CN1 PIN Function 1 PG 2 RTN 3 FF 4 INH CN2 Terminal Block Header PIN Function PIN Function 1~2 +Vo 1~5 +Vo 3~4 -Vo 6~10 -Vo 5 GND 12 GND 6 N 14 N 7 L 16 L Fan1 PIN Function 1 +FAN 2 -FAN Notes: 1. 2. 3. 4. CN1 mates with JST XHP-4 or equivalent (CHYAO SHIUNN JS-2001-04) and JST SXH-002T-P0.6 mating pins (30~26 AWG). CN2: Terminal Block option is Howder Part No. HD-121-7P. Header option mates with JST VHR-5 (input) and VHR-10 (output). Fan drive connector (Fan1) mates with JST Part No. XHP-2 or equivalent (CHYAO SHIUNN JS-2001-02). Mounting hole max screw depth is 2.0mm (M4x0.7 Inserts). cui.com page 4 of 8 For more information, please visit the product page. CUI Inc │ SERIES: PCM-400 │ DESCRIPTION: AC-DC POWER SUPPLY date 12/02/2014 MECHANICAL DRAWING - SINGLE OUTPUT MODELS (CONTINUED) CF units: mm[inch] CN1 PIN Function 1 PG 2 RTN 3 FF 4 INH CN2 Terminal Block Header PIN Function PIN Function 1~2 +Vo 1~5 +Vo 3~4 -Vo 6~10 -Vo 5 GND 12 GND 6 N 14 N 7 L 16 L Fan1 PIN Function 1 +FAN 2 -FAN CFS units: mm[inch] CN1 PIN Function 1 PG 2 RTN 3 FF 4 INH CN2 Terminal Block Header PIN Function PIN Function 1~2 +Vo 1~5 +Vo 3~4 -Vo 6~10 -Vo 5 GND 12 GND 6 N 14 N 7 L 16 L Fan1 PIN Function 1 +FAN 2 -FAN Notes: 1. 2. 3. 4. CN1 mates with JST XHP-4 or equivalent (CHYAO SHIUNN JS-2001-04) and JST SXH-002T-P0.6 mating pins (30~26 AWG). CN2: Terminal Block option is Howder Part No. HD-121-7P. Header option mates with JST VHR-5 (input) and VHR-10 (output). Fan drive connector (Fan1) mates with JST Part No. XHP-2 or equivalent (CHYAO SHIUNN JS-2001-02). Mounting hole max screw depth is 2.0mm (M4x0.7 Inserts). cui.com page 5 of 8 For more information, please visit the product page. CUI Inc │ SERIES: PCM-400 │ DESCRIPTION: AC-DC POWER SUPPLY date 12/02/2014 MECHANICAL DRAWING - DUAL OUTPUT MODELS U-FRAME units: mm[inch] CN1 PIN Function 1 PG 2 RTN 3 FF 4 INH CN2 Terminal Block Header PIN Function PIN Function 1 +Vo1 1~3 +Vo1 2~3 RTN 4~8 RTN 4 +Vo2 9~10 +Vo2 5 GND 12 GND 6 N 14 N 7 L 16 L Fan1 PIN Function 1 +FAN 2 -FAN CNF units: mm[inch] CN1 PIN Function 1 PG 2 RTN 3 FF 4 INH CN2 Terminal Block Header PIN Function PIN Function +Vo1 1 +Vo1 1~3 2~3 RTN 4~8 RTN 4 +Vo2 9~10 +Vo2 5 GND 12 GND 6 N 14 N 7 L 16 L Fan1 PIN Function 1 +FAN 2 -FAN Notes: 1. 2. 3. 4. CN1 mates with JST XHP-4 or equivalent (CHYAO SHIUNN JS-2001-04) and JST SXH-002T-P0.6 mating pins (30~26 AWG). CN2: Terminal Block option is Howder Part No. HD-121-7P. Header option mates with JST VHR-5 (input) and VHR-10 (output). Fan drive connector (Fan1) mates with JST Part No. XHP-2 or equivalent (CHYAO SHIUNN JS-2001-02). Mounting hole max screw depth is 2.0mm (M4x0.7 Inserts). cui.com page 6 of 8 For more information, please visit the product page. CUI Inc │ SERIES: PCM-400 │ DESCRIPTION: AC-DC POWER SUPPLY date 12/02/2014 MECHANICAL DRAWING - DUAL OUTPUT MODELS (CONTINUED) CF units: mm[inch] CN1 PIN Function 1 PG 2 RTN 3 FF 4 INH CN2 Terminal Block Header PIN Function PIN Function 1 +Vo1 1~3 +Vo1 2~3 RTN 4~8 RTN 4 +Vo2 9~10 +Vo2 5 GND 12 GND 6 N 14 N 7 L 16 L Fan1 PIN Function 1 +FAN 2 -FAN CFS units: mm[inch] CN1 PIN Function 1 PG 2 RTN 3 FF 4 INH CN2 Terminal Block Header PIN Function PIN Function +Vo1 1 +Vo1 1~3 2~3 RTN 4~8 RTN 4 +Vo2 9~10 +Vo2 5 GND 12 GND 6 N 14 N 7 L 16 L Fan1 PIN Function 1 +FAN 2 -FAN Notes: 1. 2. 3. 4. CN1 mates with JST XHP-4 or equivalent (CHYAO SHIUNN JS-2001-04) and JST SXH-002T-P0.6 mating pins (30~26 AWG). CN2: Terminal Block option is Howder Part No. HD-121-7P. Header option mates with JST VHR-5 (input) and VHR-10 (output). Fan drive connector (Fan1) mates with JST Part No. XHP-2 or equivalent (CHYAO SHIUNN JS-2001-02). Mounting hole max screw depth is 2.0mm (M4x0.7 Inserts). cui.com page 7 of 8 For more information, please visit the product page. CUI Inc │ SERIES: PCM-400 │ DESCRIPTION: AC-DC POWER SUPPLY date 12/02/2014 page 8 of 8 REVISION HISTORY rev. description date 1.0 initial release 07/16/2014 1.01 updated datasheet 12/02/2014 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.