DERATING CURVE (Current carrying capacity acc. IEC 60512-5-2 Test 5b) Current (A] IEC 60603-2 connector E48 with 48 contacts/type 7 F CuNiSi 8 7 6 5 4 3 2 Base curve [A] Derating curve [A] 1 Temperature [°C] 0 Base curve [A] Derating curve [A] 0 10 20 7,45 5,96 30 7,15 5,72 40 6,80 5,44 50 6,40 5,12 60 6,00 4,8 70 5,50 4,4 80 4,95 3,96 90 4,35 3,48 100 3,60 2,88 110 2,65 2,12 120 1,20 0,96 130