X

VA8201
Alpha Pager Module
The VA8201 Alpha Pager Module (APM) provides the VISTA-128BP/128FBP and VISTA-250BP/ 250FBP control
panels with alpha paging, parallel printer output, serial printer output and or home/ facility automation control
functions using a RS232 bi-directional communications protocol. The APM transmits alphanumeric security control
panel dependent messages to the paging service using Telocator Alphanumeric Protocol.
F E AT U R E S
• Alpha Paging via Telocator
Alphanumeric Protocol (TAP)
• Shares same telephone line as
alarm control panel
• Parallel printer output
• Serial output for use with
serial printer or home/facility
automation control
• Easily mounts near control panel
using bracket interface K5350
• RS232 bi-directional
communications protocol
S P E C I F I C AT I O N S
Dimensions
• 6-1/4”L x 6-1/8”W x 1-13/16”H
Input Voltage
• 12VDC (from control panel aux. power or aux. power
supply)
ORDERING
VA8201
Alpha Pager Module
Current
• 63mA (standby mode)
• 165mA (active mode)
Compatibility
• Works with: VISTA-128BP/128FBP and
VISTA-250BP/250FBP
VA8200
Panel Linking Module
The VA8200 Panel Linking Module (PLM) allows up to eight VISTA-128BP/128FBP or VISTA-250BP/250FBP
commercial alarm control panels to be linked together. Panel Linking allows multiple users to arm, disarm and check
status of any partition, for any panel, all from one location. Each module connects to the ECP bus on the control
panel, and communicates to other PLMs via the RS-485 bus (three wire twisted cable).
F E AT U R E S
• Control multiple systems,
partitions or even buildings from
one central location
• Modules are supervised with local
annunciation, central station
reporting and/or paging service
• Easy connection to the control
panel via ECP bus
• Up to eight systems can be
linked together
• Total wire run between PLM’s can
be up to 4000 feet max.
• Up to 50 users may be authorized
to access other control panels in
the network
Dimensions
Operating Temperature
RS485 Wire Run Lengths
• 6-7/16”H x 4-1/4”W x 1-1/4” D
163mm H x 108mm W x 32mm D
• 0-50°C
• The RS485 bus from one PLM to
another cannot exceed 4000 ft.
All combined bus runs combined
cannot exceed 4000 ft. using 16
gauge twisted pair cable.
S P E C I F I C AT I O N S
ECP Wire Run Lengths
Input Voltage
• 12-14VDC (from control panel
aux.power)
Current Draw
• 88mA
ORDERING
VA8200
Panel Linking Module
Honeywell Security Group
ADEMCO
165 Eileen Way, Syosset, NY 11791
www.ademco.com
Copyright ©2003 Honeywell International Inc. L/VA82001/D 7/03
Gauge Wire
22
20
18
16
Length
450 ft.
700 ft.
1100 ft.
1750 ft.
Compatibility
• Works with: VISTA-128BP/128FBP,
VISTA-250BP/250FBP,
V128FBP-24, V250FBP-24