VISTA-250FBP Data Sheet

VISTA-250FBP/V250FBP-24
COMMERCIAL PARTITIONED FIRE AND
BURGLARY ALARM CONTROL PANEL
Now UL864 9th Edition Approved
Designed to integrate seamlessly with CCTV, access control
addressable technologies. A diverse line of Honeywell
and Honeywell’s full range of fire and burglary components,
initiating devices, notification circuits, communication devices,
the new VISTA-250FBP provides the ultimate protection of life
keypads, RF receivers and relays are also supported.
and property. The UL Listed commercial fire and burglary
The VISTA-250FBP has been designed to mount quickly
control panel supports up to eight partitions and up to
and easily in an attack resistant cabinet, and is available
250 zones/points using hardwired, wireless and V-Plex®
in 12V and 24V models.
FEATURES
• Comes standard with eight hardwired
zones, expandable to 242 V-Plex
addressable points/zones or
250 wireless points/zones
• Can control eight separate areas
independently (eight partitions)
• Supports commercial wireless fire and
burglary devices
• Stores up to 1,000 events
• Supports V-Plex addressable VistaKey
access control (up to 15 doors)
• Accommodates 150 user codes and
up to 500 access card holders using
VistaKey
• Two on-board notification (bell) circuits
delivering 2.3A @ 12V or 3.4A @ 24V
• Automatic smoke detector sensitivity
maintenance testing
• Four-wire smoke reset using onboard
J2 output trigger
• Supports Dynamic Signaling for
AlarmNet communicators used in
conjunction with the phone line
• Supports remote control via AlarmNet
Total Connect Services*
• Supports Internet Alarm Reporting*
• Notification Appliance Circuits (two):
– Programmable
– Individually silenceable
• Programmable on-board auxiliary relay
• False alarm reduction features:
– Exit error logic
– Exit delay reset
– Cross zoning
– Call waiting defeat
– Recent close report
• Hardwired zones:
– Provides eight style B
hardwired zones
– Supports N.O. or N.C. sensors
– Individually assignable to any partition –
Up to 32 two-wire smoke detectors
each on zones one and two (64 total)
– Up to 50 two-wire glassbreak
detectors on zone eight
– EOLR supervised for Fire and UL
burglary installations
• Listed to UL864 9th Edition
• Upload/download via Ethernet*
• Carbon Monoxide (CO) zone support
*When used with AlarmNet devices.
VISTA-250FBP/ V250FBP-24
COMMERCIAL PARTITIONED FIRE AND
BURGLARY ALARM CONTROL PANEL
ADDITIONAL FEATURES
• Patented addressable polling
loop technology
– Supports 242 two-wire zone points
• UL Listed wireless expansion
– Supports up to 250 wireless
zones/points
– Global polling technology for
faster processing
– Supervised by control for
check-in signals
– Supervised by panel
– Tamper protection for transmitters
– Zones individually assignable to
partitions, notification circuit (bell)
output or auxiliary relay
– Individually assignable up to
eight partitions
– 4,000 ft. capability without the use
of shielded cable
– Extender/Isolation bus modules
– Eight zone – Class A and B
expander module
– Eight zone – Class B
expander module
– One zone supervised contact
monitor module
• Access Control Integration
– Full integration with PassPoint
Access Control System
• Up to 15 doors using VistaKey
Access Control
• Event reporting
• Local printer of access or
VISTA related events
• Communication
– Phone mapping by zone
response type
– Panel operation during download
Applications
Supported by a diverse line of Honeywell
initiating devices, the VISTA-250FBP is
the ideal integrated fire and burglary
control for applications where a high
level of security is necessary. Some
examples of applications include:
medical and professional buildings,
supermarkets, churches, synagogues,
schools, universities, strip malls,
factories, warehouses, and larger
residences.
SPECIFICATIONS
Electrical
Main Dialer
Agency Listings
• Primary power: 18VAC @ 72VA
ADEMCO No. 1451
• Line seize: Double Pole
• UL609 Grade A Local Mercantile
Premises and Mercantile Safe
and Vault
• Control Panel quiescent
current draw: 300mA
• Backup battery:
– 12VDC, 12AH min to 34.4AH max
– Lead acid battery (gel type)
• Alarm power: 12VDC, 1.7A max for
each notification (bell) circuit output
Total 2.3A @ 12V
• Aux. standby pwr: 12VDC, 1A max
• Total power: 2.3A at 12VDC, 3.4A at
24VDC from all sources
• Standby time: 24 hours with 1A
standby load using 34.4AH battery
• Fusing: Battery input, aux. and
notification (bell) circuit outputs are
protected using PTC circuit protectors.
All outputs are power limited
• Optional 24-volt power supply, PS 24
supplies two 24 VFW, 1.7A full wave
rectified, unfiltered outputs
• Ringer equiv.: 0.7B
• Formats: ADEMCO Low Speed,
ADEMCO 4+2 Express, ADEMCO High
Speed, ADEMCO Contact ID, Sescoa
and Radionics
• UL611/1610 Grades A, AA, Central
Station
• UL365 Grades A, AA Police Connect
• Dual phone line capability
(using 5140DLM module)
• UL864/NFPA72 Local, Central Station
and Remote Station
Cabinet Dimensions
• UL985
• 18" H X 14.5" W X 4.3" D
• Factory Mutual
Environmental
• California State Fire Marshal
• Storage temp:
14° F to 158° F
(-10° C to 70° C)
• MEA
• Operating temp:
32° F to 122° F
(0° C to 50° C)
• CAN/ULC S527 – Central Unit for Fire
Alarm Systems
• Humidity: 85% RH
• CAN/ULC S303 – Local Burglar Alarm
Unit
• EMI: Meets or exceeds the
following requirements:
– FCC Part 15, Class B Device
• CAN/ULC S525 – Audible Signal
Appliances
– FCC Part 68
– IEC EMC Directive
• CAN/ULC S304 – Central and
Monitoring Station Burglar Alarm Unit
VISTA-250FBP/V250FBP-24
COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL
COMPATIBLE DEVICES
• 4190SN Remote Point Module –
two zones
Auxiliary Devices
• 4204 – Relay Module,
four form C contacts
• 4204CF – Two supervised
output circuits
• 5881 Series RF receiver
• 5883H RF receiver
• 6220S – System printer used with
4100SM serial module
• 6160CR-2 – Red Fire Keypad
• 6160 – Burglary Keypad
Two-Wire Smoke Detectors
Conventional
Optional 24V Power Supply
• PS24 – 24V power supply – 3.4A
• 4193SN Two Zone Serial
Interface Module
Commercial Wireless Devices
• 4208SNF Class A/B Expander Module
• 5808W3 – Photoelectric
Smoke/Heat Detector
• 4208U Loop Expansion Module
– eight zones
• 5806W3 – Photoelectric Smoke
Detector
• 4293SN One Zone Serial
Interface Module
• 5809 – Wireless Heat Detector
V-Plex Extender/Isolation Modules
• 5817CB – Wireless
Commercial Transmitter
• 4297 Extender/Isolator Module
• 5869 – Hold up Transmitter
• VSI Isolator Module
• 5881ENHC – RF Receiver
V-Plex Smoke Detectors
• 5883H – RF Receiver
• System Sensor
• 5193SD
• ESL
• 5193SDT
• DSC
V-Plex Passive Infrared Detectors
• VistaKey V-Plex (addressable)
Access Control
Horn/Strobes
• 998MX
• VistaKey-SK Starter Kit
• System Sensor
• IS2500SN
• VistaKey-EX Expansion Kit
• Wheelock
• DT7500SN
Alarm Communications
• Gentex
V-Plex (Addressable) Contacts
Manual Pull Stations
• 4939SN-WH
• 7845i-ENT – Internet/Intranet
Communicator
• 5140MPS-1
• 4944SN-WH
• 5140MPS-2
• 4959SN
V-Plex (Addressable) Zone
Expanders
V-Plex Glassbreak Detectors
Access Control
• 7845GSM – Digital Cellular
Communicator
• FG1625SN
• 7845i-GSM – Internet and Digital
Cellular Communicator
• GSMCF/iGSMCF – Commercial Fire
Communication Kits (when available)
• 4101SN Single Relay/Zone Module
Product specifications subject to change.
ORDERING
V250FBP-9
V250FBP9-24
Commercial Fire and Partitioned Burglary Alarm Control Panel 12V Model
Commercial Fire and Partitioned Burglary Alarm Control Panel 24V Model
For more information: www.honeywell.com/security/hsc
Automation and Control Solutions
Honeywell Security & Communications
2 Corporate Center Dr. Suite 100
Melville, NY 11747
1.800.467.5875
www.honeywell.com
L/VSTA250FBPD/D
September 2009
© 2009 Honeywell International Inc.