VISTA-250FBP/V250FBP-24 COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL Now UL864 9th Edition Approved Designed to integrate seamlessly with CCTV, access control addressable technologies. A diverse line of Honeywell and Honeywell’s full range of fire and burglary components, initiating devices, notification circuits, communication devices, the new VISTA-250FBP provides the ultimate protection of life keypads, RF receivers and relays are also supported. and property. The UL Listed commercial fire and burglary The VISTA-250FBP has been designed to mount quickly control panel supports up to eight partitions and up to and easily in an attack resistant cabinet, and is available 250 zones/points using hardwired, wireless and V-Plex® in 12V and 24V models. FEATURES • Comes standard with eight hardwired zones, expandable to 242 V-Plex addressable points/zones or 250 wireless points/zones • Can control eight separate areas independently (eight partitions) • Supports commercial wireless fire and burglary devices • Stores up to 1,000 events • Supports V-Plex addressable VistaKey access control (up to 15 doors) • Accommodates 150 user codes and up to 500 access card holders using VistaKey • Two on-board notification (bell) circuits delivering 2.3A @ 12V or 3.4A @ 24V • Automatic smoke detector sensitivity maintenance testing • Four-wire smoke reset using onboard J2 output trigger • Supports Dynamic Signaling for AlarmNet communicators used in conjunction with the phone line • Supports remote control via AlarmNet Total Connect Services* • Supports Internet Alarm Reporting* • Notification Appliance Circuits (two): – Programmable – Individually silenceable • Programmable on-board auxiliary relay • False alarm reduction features: – Exit error logic – Exit delay reset – Cross zoning – Call waiting defeat – Recent close report • Hardwired zones: – Provides eight style B hardwired zones – Supports N.O. or N.C. sensors – Individually assignable to any partition – Up to 32 two-wire smoke detectors each on zones one and two (64 total) – Up to 50 two-wire glassbreak detectors on zone eight – EOLR supervised for Fire and UL burglary installations • Listed to UL864 9th Edition • Upload/download via Ethernet* • Carbon Monoxide (CO) zone support *When used with AlarmNet devices. VISTA-250FBP/ V250FBP-24 COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL ADDITIONAL FEATURES • Patented addressable polling loop technology – Supports 242 two-wire zone points • UL Listed wireless expansion – Supports up to 250 wireless zones/points – Global polling technology for faster processing – Supervised by control for check-in signals – Supervised by panel – Tamper protection for transmitters – Zones individually assignable to partitions, notification circuit (bell) output or auxiliary relay – Individually assignable up to eight partitions – 4,000 ft. capability without the use of shielded cable – Extender/Isolation bus modules – Eight zone – Class A and B expander module – Eight zone – Class B expander module – One zone supervised contact monitor module • Access Control Integration – Full integration with PassPoint Access Control System • Up to 15 doors using VistaKey Access Control • Event reporting • Local printer of access or VISTA related events • Communication – Phone mapping by zone response type – Panel operation during download Applications Supported by a diverse line of Honeywell initiating devices, the VISTA-250FBP is the ideal integrated fire and burglary control for applications where a high level of security is necessary. Some examples of applications include: medical and professional buildings, supermarkets, churches, synagogues, schools, universities, strip malls, factories, warehouses, and larger residences. SPECIFICATIONS Electrical Main Dialer Agency Listings • Primary power: 18VAC @ 72VA ADEMCO No. 1451 • Line seize: Double Pole • UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault • Control Panel quiescent current draw: 300mA • Backup battery: – 12VDC, 12AH min to 34.4AH max – Lead acid battery (gel type) • Alarm power: 12VDC, 1.7A max for each notification (bell) circuit output Total 2.3A @ 12V • Aux. standby pwr: 12VDC, 1A max • Total power: 2.3A at 12VDC, 3.4A at 24VDC from all sources • Standby time: 24 hours with 1A standby load using 34.4AH battery • Fusing: Battery input, aux. and notification (bell) circuit outputs are protected using PTC circuit protectors. All outputs are power limited • Optional 24-volt power supply, PS 24 supplies two 24 VFW, 1.7A full wave rectified, unfiltered outputs • Ringer equiv.: 0.7B • Formats: ADEMCO Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics • UL611/1610 Grades A, AA, Central Station • UL365 Grades A, AA Police Connect • Dual phone line capability (using 5140DLM module) • UL864/NFPA72 Local, Central Station and Remote Station Cabinet Dimensions • UL985 • 18" H X 14.5" W X 4.3" D • Factory Mutual Environmental • California State Fire Marshal • Storage temp: 14° F to 158° F (-10° C to 70° C) • MEA • Operating temp: 32° F to 122° F (0° C to 50° C) • CAN/ULC S527 – Central Unit for Fire Alarm Systems • Humidity: 85% RH • CAN/ULC S303 – Local Burglar Alarm Unit • EMI: Meets or exceeds the following requirements: – FCC Part 15, Class B Device • CAN/ULC S525 – Audible Signal Appliances – FCC Part 68 – IEC EMC Directive • CAN/ULC S304 – Central and Monitoring Station Burglar Alarm Unit VISTA-250FBP/V250FBP-24 COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL COMPATIBLE DEVICES • 4190SN Remote Point Module – two zones Auxiliary Devices • 4204 – Relay Module, four form C contacts • 4204CF – Two supervised output circuits • 5881 Series RF receiver • 5883H RF receiver • 6220S – System printer used with 4100SM serial module • 6160CR-2 – Red Fire Keypad • 6160 – Burglary Keypad Two-Wire Smoke Detectors Conventional Optional 24V Power Supply • PS24 – 24V power supply – 3.4A • 4193SN Two Zone Serial Interface Module Commercial Wireless Devices • 4208SNF Class A/B Expander Module • 5808W3 – Photoelectric Smoke/Heat Detector • 4208U Loop Expansion Module – eight zones • 5806W3 – Photoelectric Smoke Detector • 4293SN One Zone Serial Interface Module • 5809 – Wireless Heat Detector V-Plex Extender/Isolation Modules • 5817CB – Wireless Commercial Transmitter • 4297 Extender/Isolator Module • 5869 – Hold up Transmitter • VSI Isolator Module • 5881ENHC – RF Receiver V-Plex Smoke Detectors • 5883H – RF Receiver • System Sensor • 5193SD • ESL • 5193SDT • DSC V-Plex Passive Infrared Detectors • VistaKey V-Plex (addressable) Access Control Horn/Strobes • 998MX • VistaKey-SK Starter Kit • System Sensor • IS2500SN • VistaKey-EX Expansion Kit • Wheelock • DT7500SN Alarm Communications • Gentex V-Plex (Addressable) Contacts Manual Pull Stations • 4939SN-WH • 7845i-ENT – Internet/Intranet Communicator • 5140MPS-1 • 4944SN-WH • 5140MPS-2 • 4959SN V-Plex (Addressable) Zone Expanders V-Plex Glassbreak Detectors Access Control • 7845GSM – Digital Cellular Communicator • FG1625SN • 7845i-GSM – Internet and Digital Cellular Communicator • GSMCF/iGSMCF – Commercial Fire Communication Kits (when available) • 4101SN Single Relay/Zone Module Product specifications subject to change. ORDERING V250FBP-9 V250FBP9-24 Commercial Fire and Partitioned Burglary Alarm Control Panel 12V Model Commercial Fire and Partitioned Burglary Alarm Control Panel 24V Model For more information: www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 Melville, NY 11747 1.800.467.5875 www.honeywell.com L/VSTA250FBPD/D September 2009 © 2009 Honeywell International Inc.