X

DUAL TEC Family Feature Chart
DT-7000 Series
Uniform
Sens
Dual Core
Uniform
Sens
Dual Core
K
•
•
Temperature Compensation
Std
Adv
Adv
Adv
•
•
•
MAP
MAP
MAP
Std
Std
Std
Mirror
Mirror
X
K
•
•
MAP
X
K
•
Adv
Uniform
Sens
Std
•
Std
50' Diam
Std
Std
K
•
Std
100'x20'
Queue
Event
Logic
Mirror
•
Std
•
•
•
•
•
Mirror
60'x75'
3
C
Std
Std
Std
S
X
X
X
X
X
X
X
•
•
•
•
•
•
•
•
•
•
•
•
Std
Adv
Adv
Adv
Std
•
•
•
DT900 only
DT906 only
•
•
•
Std
Std
Std
Std
•
•
•
•
•
•
•
•
•
•
PIR Sensitivity Adjustment
•
•
•
•
•
•
•
•
•
•
•
•
•
Microwave Adjustment
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Vertical/Horizontal Adjustment
Trouble Output
•
•
35'x30'
S
•
Anti-Masking
Queue
Event
Logic
•
•
Analog Fluorescent Filter
•
120'x10'
200'x15'
5897-35
Dual Core
•
Walk Test Mode
50'x40'
90'x70'
Quest
2260SN
60'x60'
V-Plex Wireless
•
50'x60'
Environmental Adaptation
Digital Fluorescent Filter
40'x40'
DT-906/907
35'x30'
DT-900/901
50'x40'
DT-9 Series
DT-6360STC
35'x30'
DT-6100STC
50' Diam.
DT-660STC
50'x60'
DT-6 Series
DT-640STC
K
Microprocessor
DT-500
Uniform
Sens
DT-450T
Dual Core
DT-435T
Microwave Frequency Band
Std
Uniform
Sens
DT-7360
Optical Technology
•
35'x40'
DT-5
DT-7550C
Signal Processing
•
35'x40'
DT-7450
Coverage Pattern
DT-7435
Pet Immune to 100 lbs.
DT-7235T
FEATURES
DT-4 Series
auto
•
•
•
•
•
•
•
•
•
•
•
VPlex
RF
Tamper Switch(es)
•
•
•
•
••
•
•
Optional
•
••
•
•
•••
•••
Alarm Relay Forms
A
A,C
A,C
C
C
A,C
A,C
A
C
C
C
C
C
C
Tri-Color
3LEDs
3LEDs
3LEDs
3LEDs
3LEDs
3LEDs
3LEDs
3LEDs
3LEDs
3LEDs
2LEDs
2LEDs
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
LED Indicators
Microwave Supervision
1LED
•
PIR Supervision
Tri-Color Tri-Color
•
•
•
•
•
•
•
•
•
Recommended Mtg Height
7' 6"
7' 6"
7' 6"
7' 6"
8’ to 16’
7' 6"
7' 6"
7' 6"
7' 6"
7'6"
7'6"
8’ to 16’
6' to 12'
6' to 12'
7' to 8'
7'6"
Operating Temperature (°c)
-10 to 55
-10 to 55
-10 to 55
-10 to 55
0 to 49
0 to 49
0 to 49
10 to 49
0 to 49
0 to 49
0 to 49
0 to 49
0 to 49
0 to 49
10 to 50
0 to 60
Input voltage (VDC)
7.5 - 1 6
7.5 - 1 6
7.5 - 1 6
7.5 - 1 6
10 - 14.5
9 - 14
10 - 14.5
10 - 14.5
10 - 14.5
10 - 14.5
10 - 15
10 - 15
-10 - 15
3V battery
Maximum Current (ma)
25
35
35
40
40
35
35
35
35
35
40
40
35
35
Swivel Bracket Options
SMB-10
SMB-10T
SMB-10
SMB-10T
SMB-10
SMB-10T
SMB-10
SMB-10T
SMB-10
SMB-10T
SMB-10
SMB-10T
SMB-10
SMB-10T
SMB-10
SMB-10T
SMB-10
SMB-10T
SMB-10
SMB-10T
Included
Included
10 - 14.5 10 - 14.5
9985B
Pet Immune to 100lbs.:
Sensor is immune to pets and other animals with combined weight
of 100lbs when installation guidelines for pet immunity are followed.
Environmental Adaption:
Microwave thresholds are adapted either in hardware or digitally
to remove the effect of low level interference such as ceiling fans.
Coverage pattern:
Length by width of area protected.
Temperature Compensation:
Sensor automatically adjusts PIR thresholds and/or other
parameters to adapt to change in ambient temperature relative to
human body temperature.
Standard; Compensates at ambient
temperatures below body temperature.
Advanced: Compensates at ambient both
below and above body temperature.
Signal Processing:
Analysis performed on PIR and microwave signals to determine
alarm conditions.
DualCore: Signals are analyzed in
multiple domains, including amplitude,
time, frequency and duration.
Supports functions including diagnostics
and other advance false alarm features.
C3: Correlates data from both channels
simultaneously, instead of independently
processing each.
MAP: Timing and sequence of signals are
compared to settings for specific
environments to qualify each channel
individually.
Queue Event Logic: Pulse counting while
looking for specific sequences of events.
Advanced: Pulse counting with timing
relationships.
Standard: Basic pulse counting.
Optical Technology:
Technology used to collect infrared radiation for PIR processing.
Uniform Sensitivity: Fresnel lens that provides the same
sensitivity at the edge of the pattern as exists directly in
front of the sensor.
Split-Zone: Zones are split into two
sub-zones where each sub-zone has half the
sensitiv
ity of a regular zone, requiring targets to be in both zones
for an alarm.
Standard: Basic Fresnel lens.
Mirror: Basic mirror optics.
Microwave Frequency Band:
Frequency at which the microwave signal is radiated and
received. Higher frequencies generally penetrate non-metallic
objects less than lower frequencies.
S-band: 2.54 GHz
X-band: 10.525 GHz
K-band: 24.125 GHz
Honeywell Security & Custom Electronics
PO Box 9035, Syosset, NY 11791
www.security.honeywell.com/sce
Digital Fluorescent Light Filter:
Software algorithms provide infinite rejection of microwave interference due to fluorescent lights.
Analog Fluorescent Light Filter:
Hardware circuitryprovides rejection of microwaveinterferences
due to fluorescent lights.
Anti-Masking:
Detects intentional and accidental blocking of the PIR optics.
Walk Test Mode:
Determines the coverage pattern and functionality for both the
PIR and microwave channels, usually through LED indicators.
PIR Sensitivity Adjustment:
Selectable option to change the PIR process sensitivity, usually
through a DIP switch or jumper link.
Microwave Sensitivity Adjustment::
Selectable option to change the microwave sensitivity and/or
range, usually through a potentiometer.
Vertical Adjustment:
Capability to adjust the vertical PIR detector position relative to
the optics,usually through a vertical shift in the PCB. Usually used
to adjust range at different mounting heights, or accurately set
the coverage pattern for different lenses or mirrors.
Horizontal Adjustment:
Capability to shift the PIR zones left or right by a few degrees.
Usually used to locate potential false alarm sourest, such as a
heating vent between zones, or to aim the optics in a particular
direction, such as a hallway.
L/DTCHART/D
October 2004
©2004 Honeywell International Inc.
Trouble Output:
Separate output used to indicate supervision failures
and/or anti-mask detection to the control panel.
Alarm Relay Forms:
Type of output relay used to signal panel when an intrusion
is detected.
Form A: Two-terminal relay with Normally
Closed output when energized.
Form C: Three-terminal relay with both
Normally Closed and Normally Open
outputs when energized.
LED Indicators:
Light Emitting Didoes used to provide visual feedback
about alarm state, supervision, walk test, and other
modes of operation.
1 LED: Single red LED
3 LEDs: Red, green, yellow LEDs, usually
with PIR and microwave channels
associated with a specific color.
Microwave Supervision:
Automatic self-test of microwave channel for proper operation.
PIR Supervision:
Automatic self-test of microwave channel for proper operation.
Recommended Mounting Height:
Suggested height to mount processor for optimal performance.
Usually important for pet immune applications.
Operating Temperature:
Temperature range at which the sensor can be expected to
provide adequate protection. UL certification may
have a narrower range.
Input Voltage:
Voltage range at the terminalstrip at which the sensor will
operate. UL may have certified for a slightly narrower range.
Swivel Bracket Options:
Brackets used to mount sensors in installations that have
special aiming or mounting heights.