SWIFT™ Intelligent Wireless Modules Description SWIFT™ (Smart Wireless Integrated Fire Technology) wireless modules are intelligent (addressable) modules that provide secure, reliable communication to the Fire Alarm Control Panel (FACP) using a Class A, mesh network. Wireless modules can be used in the following types of conditions, where it is costly, obtrusive, or possibly dangerous to use traditional wired devices. • concrete walls/ceilings • surface-mount conduit • buried wires • asbestos In addition, both wired and wireless devices can be present on the same FACP providing an integrated wired-wireless solution to offer increased installation potential. The mesh network (within the SWIFT System) creates a child-parent relationship (for example, backup communication) between the devices, so that each device has two parents providing a secondary path to transmit communications on every device. If one device can no longer operate for any reason, the remaining devices can continue to communicate directly with each other, or they can communicate through one or more intermediate devices. After an initial mesh network is formed, mesh restructuring automatically occurs. The mesh restructuring locates the strongest paths possible within the network. SWIFT Monitor Module The SWIFT monitor module is intended for use with a wireless gateway or wireless FACP to interface with a device having contacts used to signal status conditions. It is designed to provide an interface to the following types of contact devices. • security contacts • waterflow switches • pull stations. The input to the monitor module is non-latching and does not require a reset. The device has a panel controlled LED indicator. The monitor module must be within 3 feet of the monitored device. SWIFT Relay Module The SWIFT relay module allows a compatible control panel to switch discreet contacts by code command. The relay contains an isolated set of Form-C contacts, which operate as a DPDT switch. Circuit connections to the relay are not supervised by the module. The SWIFT relay module can be used to activate the following functions: • remote power supply (in conjunction with a monitor module). • elevator recall. • door holders and fan shutdown of wired devices. • SWIFT devices within the same mesh network. The module also includes a panel-controlled LED indicator. SWIFT, Smart Wireless Integrated Fire Technology SWIFT Intelligent Wireless Modules Features • Complies with UL® Standard 864 Listing. • Connects to E3 Series® or S3 Series fire alarm control panels. • Each mesh supports up to 48 wireless devices per gateway. • Uses redundant wireless mesh technology to support Class A survivability. • Employs frequency hopping to eliminate outside interference. • Engages each device to act as a signal repeater/ booster, avoiding large and costly separate repeater units. • Combines mixed wired Velociti® devices and wireless devices on the same SLC loop. • Includes multi-device alarm activation. • Designed with tamper-proof construction. • Has addressable code wheels. • Applies low battery, signal pre-warning. Ordering Information Part Number Description WAM-MM Wireless Monitor Module WAM-RC Wireless Addressable Module-Relay Control Accessory: SWIFT Tools USB Adapter W-USB *Note: Consult the Fire Alarm Control Panel Manufacturer to obtain the complete system requirements. E3 Series® and Velociti® are registered trademarks and SWIFT™ and Acclimate™ are trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. SIGNALING FM APPROVED S1949 3053714 7300-1703:0181 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. www.gamewell-fci.com 9021-60819 Rev. D page 1 of 2 ©2015 by Honeywell International Inc. All rights reserved. DEVICE 4 E3 OR S3 FACP DEVICE 1 GATEWAY U DRIVER DEVICE 3 DEVICE 2 ANNUNCIATOR USB SWIFT TOOLS DEVICE 5 PARENT CHILD Note: An optional USB wireless transceiver that communicates with the GATEWAY and SWIFT Tools software aids in the site survey, mesh formation, and diagnostics of the system. Figure 1 SWIFT Mesh Network Description (Continued) All sensors offer addressable code wheels and one LED. The LED is controlled by the panels. Operational modes include red, green and amber colors with various solid or blink patterns. The devices transmit communication signals across the mesh network through a gateway to the FACP. Some systems may require a user interface and annunciator to display wireless specific messages. The FACP identifies the SWIFT wireless device as another addressable device on the system providing similar detection functions and outputs as a wired counterpart. In addition, both wired and wireless devices can be present on the same FACP to meet the needs of a given application. A SWIFT wireless System can use any combination of modules, smoke or heat detectors. The SWIFT System also engages frequency hopping to prevent system interference whether intentional or accidental.The operation of each device is subject to the following conditions in compliance with the FCC Standards, Part 15. 1. The device may not cause harmful interference. 2. The device must accept any interference received including interference that may cause undesired operation. SWIFT Intelligent Wireless Modules Specifications (Continued) Electrical Specifications Maximum Operating Voltage: Average Operating Current: Maximum Current Draw: EOL Resistance: Maximum IDC Wiring Resistance: Maximum IDC Voltage: Maximum Average IDC Current: Maximum Transmit RF Power: Radio Frequency Range: Relay Module Specifications Electrical Specifications Maximum Operating Voltage: Average Operating Current: Maximum Current Draw: Maximum Transmit RF Power: Radio Frequency Range: Current Rating 2A 3A 2A 0.46 A 0.7 A 0.9 A 0.5 A 0.3 A SWIFT Intelligent Wireless Modules Specifications Physical/Operating Specifications Dimensions: Device Weight with 4 batteries & face-plate: Operating Temperature Range: Operating Humidity Range: H:4¼” x W:4¼” x D:1½” (H:10.79 x W:10.79 x D:3.8 cm) 7.9 oz (224 g) 32°F to 120°F (0°C to 49°C) 10% to 93% non-condensing 3.3 VDC 210 µA, 3.9k EOL 5.0 mA (LED on) 3.9K Ohms 10 Ohms 3.2 Volts 5.5 µA 17dBm 902-928 MHz 3.3 VDC 210 µA 5 mA (LED on) 17 dBm 902-928 MHz Maximum Load Voltage Description Application 25 VAC PF = 0.35 Non-coded 30 VDC Resistive Non-coded 30 VDC Resistive Coded 30 VDC (L/R = 20ms) Non-coded 70.7 VAC PF = 0.35 Non-coded 125 VDC Resistive Non-coded 125 VAC PF = 0.75 Non-coded 125 VAC PF = 0.35 Non-coded Table 1: Relay Contact Ratings Battery Specifications Battery Type: 4 Panasonic CR123A or 4 Duracell DL123A Battery Life: 2 year minimum Battery Replacement: Upon TROUBLE BATTERY LOW display and/or during annual maintenance GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60819 Rev. D page 2 of 2 www.gamewell-fci.com