For Instructions, please see: http://www.erni.com/DB/derating/DERATING-Instructions.pdf DERATING CURVE (Current carrying capacity acc. IEC 60512-5-2 Test 5b) Current (A] IEC 60603-2 connector E48 with 48 contacts 8 7 6 5 4 3 2 Base curve [A] Derating curve [A] 1 Temperature [°C] 0 0 Base curve [A] Derating curve [A] © ERNI Elektroapparate GmbH 2006 10 20 6,6 5,28 30 6,4 5,12 40 6,1 4,88 50 5,8 4,64 60 5,4 4,32 70 5 4 80 4,5 3,6 90 4 3,2 100 3,3 2,64 All rights reserved. Only for information. Subject to modification without prior notice. 110 2,4 1,92 120 1,1 0,88 130