DERATING CURVE (Current carrying capacity acc. IEC 60512-5-2 Test 5b)
Current (A]
Microspeed connector with 50 contacts
1,6
1,4
1,2
1
0,8
0,6
0,4
Base curve [A]
Derating curve [A]
0,2
Temperature [°C]
0
0
Base curve [A]
Derating curve [A]
© ERNI Elektroapparate GmbH 2006
10
20
1,08
0,86
30
1,00
0,80
40
0,91
0,73
50
0,79
0,63
60
0,67
0,53
70
0,50
0,40
All rights reserved. Only for information. Subject to modification without prior notice.
80
0,25
0,20
90
For Instructions, please see:
http://www.erni.com/DB/derating/DERATING-Instructions.pdf
DERATING CURVE (Current carrying capacity acc. IEC 60512-5-2 Test 5b)
Current (A]
Microspeed connector with 50 contacts
1,6
1,4
1,2
1
0,8
0,6
0,4
Base curve [A]
Derating curve [A]
0,2
Temperature [°C]
0
0
Base curve [A]
Derating curve [A]
© ERNI Elektroapparate GmbH 2006
10
20
1,35
1,08
30
1,30
1,04
40
1,23
0,99
50
1,16
0,93
60
1,08
0,86
70
1,00
0,80
80
0,91
0,73
90
0,79
0,63
100
0,67
0,53
All rights reserved. Only for information. Subject to modification without prior notice.
110
0,50
0,40
120
0,25
0,20