EN

Vision sensors
XF-100
VS XF100M03W10EP
Article number: 11039658
features
„„User management
„„Password protection
„„Backup & Restore function
„„Coordinate transformation
„„flexible result conjunction
mechanical data
resolution
752 × 480 px
width
53 mm
sensor type
1/3” CMOS, monochrome
height
99,5 mm
LED class
risk group 1 (low risk, EN
62471:2008)
depth
38 mm
material
housing: aluminum
cover glass: PMMA
weight
≤ 250 g
high-resolution mode
max. 50 inspections per second
high-speed mode (limited
resolution)
max. 100 inspections per second
object distance min.
50 mm
number of jobs (products)
≤ 255
features per job
32
defect image memory
32
signal processing
Baumer FEX 4.0
illumination
integrated, LED white
lens
10 mm
environmental conditions
®
electrical data
18 ... 30 V DC
power consumption
typical 5 W (I = 1 A at 24 V)
digital inputs
5 inputs (8 … 30 V)
trigger
job selection
external teach-in
encoders (CH-A, CH-B) 500 kHz
max
5 outputs (PNP)
Pass / Fail
Flash Sync
Alarm
Camera Ready
Output Enable
Ethernet (10BASE-T /
100BASE-TX)
process interface
TCP|UDP (Ethernet)
visualization
web interface
-20 … +70 °C
case temperature
max. +50 °C
humidity
0 … 90 % (non-condensing)
protection class
IP 67
vibration load
IEC 60068-2-6
IEC 60068-2-64
mechanical shock resistance
EN 60068-2-27
part location
part location on contours
part location on edges
part location on circle
part location on text line
geometry
distance
circle
angle
count edges
point position
edge characteristics
feature comparison
count contour points
contour comparison
brightness
contrast
area size
count areas
pattern comparison
EN / 100516
initial setup
+5 … +50 °C
storage temperature
feature checks
voltage supply range +Vs
digital outputs
operating temperature
The product characteristics and technical data provided do not express or imply any warranty. Technical modifications and errors reserved.
general data
www.baumer.com
Data sheet VS XF100M03W10EP
page 1 / 2
Vision sensors
XF-100
VS XF100M03W10EP
Article number: 11039658
electrical connection M12 / 12-pin (on device)
7 6
8
9 12 11 5
1
4
10
2 3
1:
PWR (+18-30 V DC)
7:
OUT3
2:
Ground
8:
IN3
3:
IN1 (Trigger)
9:
OUT4
4:
OUT1
10:
IN4
5:
IN2
11:
IN5
6:
OUT2
12:
OUT5
Ethernet connection M12 / 4-pin (on device)
3
4
2
1
1:
TD+
3:
TD-
2:
RD+
4:
RDThe product characteristics and technical data provided do not express or imply any warranty. Technical modifications and errors reserved.
dimension drawing
112,9
99,5+0,6
40
53+0,6
EN / 100516
38
51
4x M4 /4
28,5
40
www.baumer.com
Data sheet VS XF100M03W10EP