c14

For more information, please visit the product page.
date
05/20/2014
page
1 of 7
SERIES: C14 │ DESCRIPTION: PANEL MOUNT ENCODER
FEATURES
•
•
•
•
•
•
2-bit quadrature output
compact
rugged metal design
1 million cycle life
multiple termination options
IP65 rating option
ELECTRICAL
parameter
conditions/description
power supply
3.3Vdc input models
5Vdc input models
supply current
3.3Vdc input models
5Vdc input models
output
open collector
output code
2-bit quadrature, channel A leads channel B by 90°
with clockwise rotation
power consumption
3.3Vdc input models
5Vdc input models
output resolution
4 ppr (16 cpr), 8 ppr (32 cpr)
angle of throw
16 detent postion models
32 detent postion models
min
typ
max
units
3.168
4.75
3.3
5
3.432
5.25
Vdc
Vdc
40
20
mA
mA
132
100
mW
mW
22.5
11.25
°
°
PUSH SWITCH SPECIFICATIONS
parameter
conditions/description
rating
12 Vdc at 50 mA
min
typ
contact resistance
isolation voltage
for 1 minute
max
units
200
mΩ
250
Vac
MΩ
insulation resistance
100
operating push force
3.5
4.5
5.5
N
travel
0.2
0.5
0.8
mm
bounce
10
push switch life
1,000,000
ms
cycles
ENVIRONMENTAL
parameter
max
units
operating temperature
conditions/description
min
-10
70
°C
storage temperature
-20
80
°C
vibration
10~55Hz with a peak to peak amplitude of 1.5mm
shock
half sine wave for 11ms
cold test
at -20°C for 96 hours
heat test
at +80°C for 96 hours
typ
50
cui.com
G
For more information, please visit the product page.
CUI Inc │ SERIES: C14 │ DESCRIPTION: PANEL MOUNT ENCODER
date 05/20/2014│ page 2 of 7
ENVIRONMENTAL (CONTINUED)
parameter
conditions/description
temperature change test
at -10~70°C for 30 minutes each
humidity test
at 40°C, 90~95% humidity for 96 hours
RoHS
2011/65/EU
min
typ
max
units
min
typ
max
units
10
15
N
N
0.2
0.6
N·cm
N·cm
MECHANICAL
parameter
conditions/description
shaft load
radial
axial
operational torque
without detent
with detent
0.2
0.4
mounting torque
rotational life
100
N·cm
1,000,000
cycles
11
g
weight
OUTPUT WAVEFORMS
&:
2XWSXW $
2XWSXW %
Ѝ
3RVLWLRQ
2XWSXW
$
%
9㸸9 PD[ 9 PLQ
㸨7KH FRGH UHSHDWV IURP WR PART NUMBER KEY
9 㸸9 PD[ 9 PLQ
C14XXXX - XXXX
Input Voltage:
“blank” = 5 V input
3 = 3.3 V input
Base Number
Detent:
D = with detent
N = without detent
Waterproof:
“blank” = standard
A = IP65
Angle of throw:
16 = 22.5° for code change
and 16 detent positions
32 = 11.25° for code change and 32 detent positions
Push Switch:
P = with push switch
N = without push switch
cui.com
Termination:
A = Ø0.5 mm holes
B = 130 mm cable with connector
C = with header I
D = with header II
E = horizontal PCB
F = vertical PCB
Shaft Diameter:
1 = Ø3.175 mm (1/8”)
2 = Ø6 mm
3 = Ø6.35 mm (1/4”)
For more information, please visit the product page.
CUI Inc │ SERIES: C14 │ DESCRIPTION: PANEL MOUNT ENCODER
date 05/20/2014│ page 3 of 7
OUTPUT CIRCUIT
5V Input
3.3V Input
3LQ 1R
3LQ 1R
9
5
5
287387 $
9
5
287387 $
5
287387 %
5
5
6:,7&+
6:,7&+
287387 %
6:,7&+
6:,7&+
*1'
5
*1'
㸨55([WHUQDO SXOOXS UHVLVWRUV .Ȑ
㸨55([WHUQDO SXOOXS UHVLVWRUV .Ȑ
MECHANICAL DRAWING
5V INPUT, WITH PUSH SWITCH
units: mm
Ø6.0mm Shaft
0 3 ȭ
0 S Mounting Hole
Dimensions
s
CUIINC
ȭ &
ȭ
0$'( ,1 -$3$1
PD[
3LQ 1R
KROH
s
ȭ ȭ s
Ø6.35mm Shaft
PD[
Ø3.175mm Shaft
s
PD[
s
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: C14 │ DESCRIPTION: PANEL MOUNT ENCODER
date 05/20/2014│ page 4 of 7
MECHANICAL DRAWING (CONTINUED)
5V INPUT, WITHOUT PUSH SWITCH
units: mm
Ø6.0mm Shaft
0 3 ȭ
0 S Mounting Hole
Dimensions
ȭ CUIINC
s
&
ȭ
0$'( ,1 -$3$1
PD[
3LQ 1R
KROH
s
ȭ ȭ s
Ø6.35mm Shaft
PD[
PD[
Ø3.175mm Shaft
s
s
3.3V INPUT, WITH PUSH SWITCH
units: mm
Ø6.0mm Shaft
0 3 ȭ
0 S Mounting Hole
Dimensions
0$'( ,1 -$3$1
PD[
3LQ 1R
KROH
s
ȭ
ȭ s
PD[
Ø6.35mm Shaft
CUIINC
s
ȭ &
ȭ
PD[
Ø3.175mm Shaft
s
s
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: C14 │ DESCRIPTION: PANEL MOUNT ENCODER
date 05/20/2014│ page 5 of 7
MECHANICAL DRAWING (CONTINUED)
3.3V INPUT, WITHOUT PUSH SWITCH
units: mm
Ø6.0mm Shaft
0 3 ȭ
0 S Mounting Hole
Dimensions
s
ȭ &
ȭ
CUIINC
0$'( ,1 -$3$1
PD[
3LQ 1R
KROH
s
ȭ ȭ s
Ø6.35mm Shaft
PD[
PD[
Ø3.175mm Shaft
s
s
MECHANICAL DRAWING, TERMINATION OPTIONS
units: mm
OPTION A: Ø0.5MM HOLES
OPTION B: 130MM CABLE WITH CONNECTOR
ȭKROH
&211(&725 $03 31 Mounting Hole
Dimensions
s
ȭ
s
ȭ
Mounting Hole
Dimensions
PCB Layout
tolerance: ±0.05
s
ȭ
ȭ
ȭ
cui.com
PCB Layout
tolerance: ±0.05
s
ȭ
OPTION C: HEADER II
s
OPTION C: HEADER I
ȭ
For more information, please visit the product page.
CUI Inc │ SERIES: C14 │ DESCRIPTION: PANEL MOUNT ENCODER
date 05/20/2014│ page 6 of 7
MECHANICAL DRAWING, TERMINATION OPTIONS (CONTINUED)
units: mm
OPTION E: HORIZONTAL PCB
PCB Layout
tolerance: ±0.05
ȭ
ȭ
3LQ 1R
W 0$'( ,1 -$3$1
0RXQWLQJ ERDUG
ȭ
CUIINC
0$0$&
OPTION F: VERTICAL PCB
PCB Layout
tolerance: ±0.05
CUIINC
Note:
1. Protects against ingress of water (IP65) from front side of panel only.
cui.com
No.
Qty.
Component
1
1
waterproof washer
2
1
panel
3
1
toothed lock washer
4
1
nut
WATERPROOF MOUNTING
0;30$&
ȭ
ȭ
W 3LQ 1R
ȭ
0$'( ,1 -$3$1
For more information, please visit the product page.
CUI Inc │ SERIES: C14 │ DESCRIPTION: PANEL MOUNT ENCODER
date 05/20/2014│ page 7 of 7
REVISION HISTORY
rev.
description
date
1.0
initial release
02/25/2009
1.01
applied new spec template, updated operating temperature, updated
3.3V PCB
05/20/2014
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.