データシート

For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
date
02/08/2016
page
1 of 4
SERIES: SMI5-USB │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
up to 5 W continuous power
DOE Level VI, CEC, ErP Stage 2
no load power consumption < 0.1 W
universal input voltage range
interchangeable Ac blades for global use
over voltage and short circuit protections
UL/cUL, GS, RCM, CCC, PSE safety approvals
MODEL
output
voltage
output
current
output
power
ripple
and noise1
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
5
1
5
300
SMI5-5-I38
Notes:
efficiency
level
VI
1. At full load, nominal Vac input, 25 °C, 20 MHz bandwidth oscilloscope, each output terminated with 0.1 μF and 10 μF capacitors.
PART NUMBER KEY
SMI5 - 5 - X - I38 - CXX
Base Number
Reserved for Custom
Configurations
Output Voltage
Blades:
V = North America, Europe, United Kingdom,
Australia, and China blade included
N = North America blade included
E = Europe blade included
B = United Kingdom blade included
A = Australia blade included
C = China blade included
K = No blades included
cui.com
USB Type A Inlet
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: SMI5-USB │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/08/2016 │ page 2 of 4
INPUT
parameter
conditions/description
min
voltage
frequency
current
typ
90
47
at 115/230 Vac
leakage current
no load power consumption
at 115/230 Vac, 60/50 Hz
max
units
264
Vac
63
Hz
0.2
A
0.02
mA
0.075
W
max
units
OUTPUT
parameter
conditions/description
min
typ
line regulation
±5
load regulation
±5
turn on time
%
%
3
s
max
units
PROTECTIONS
parameter
conditions/description
min
typ
over voltage protection
over current protection
output shut down, auto recovery
10
Vdc
1.5
A
max
units
short circuit protection
SAFETY & COMPLIANCE
parameter
conditions/description
min
isolation voltage
input to output at 10 mA for 1 minute
safety approvals
UL/cUL, GS, RCM, CCC, PSE
EMI/EMC
FCC Part 15B Class B, CE
MTBF
as per Telcordia SR-332 Issue 2, at 115/230 Vac,
full load, 0 ~ 40°C
RoHS
2011/65/EU
typ
3,000
4,242
Vac
Vdc
50,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
storage temperature
max
units
0
typ
40
°C
-20
60
°C
operating humidity
non-condensing
20
85
%
storage humidity
non-condensing
5
95
%
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: SMI5-USB │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/08/2016 │ page 3 of 4
MECHANICAL
parameter
conditions/description
dimensions
47 x 34.5 x 26.5
min
inlet plug
interchangeable blades (North America, Europe, UK, Australia, China)
typ
max
mm
weight
80
MECHANICAL DRAWING
units: mm
PIN
Output Voltage
1
+5V
2
short
3
short
4
GND
+5
GND
units
1
4
INTERCHANGEABLE BLADES
BLADE
DESIGNATOR
N
E
B
A
C
REGION
North
America
Europe
UK
Australia
China
BLADE
ACCESSORY
SMI-US-3
SMI-EU-3
SMI-UK-3
SMI-AU-3
SMI-CN-3
BLADE
cui.com
g
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: SMI5-USB │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/08/2016 │ page 4 of 4
REVISION HISTORY
rev.
description
date
1.0
initial release
08/07/2015
1.01
updated datasheet
02/08/2016
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.