10A/50W

Technical
Specification
PQ60050EKx10
48V
100V
5V
10A
2000V dc
Eighth-brick
Input
Transient Input
Output
Current
Isolation
DC-DC Converter
®
The PowerQor Eighth-brick series is composed of next
generation, board-mountable, isolated, fixed switching
frequency dc/dc converters that use synchronous
rectification to achieve extremely high power conversion
efficiency. The power dissipated by the converter is
so low that a heatsink is not required, which saves
cost, weight, height, and application effort. All of
the power and control components are mounted to
the multi-layer PCB substrate with high-yield surface
mount technology. Since the PowerQor converter has
no explicit thermal interfaces, it is extremely reliable.
RoHS Compliant (See page 15).
Operational Features
PQ60050EKA10
Module
• High efficiency, 88% at full rated load current
• Delivers up to 50W of output power with minimal derating no heatsink required
• Operating input voltage range: 35V-75V, with 100V, 100ms input
voltage transient capability
Control Features
• Fixed frequency switching provides predictable EMI performance
• No minimum load requirement means no preload resistors required
• On/Off control referenced to input side (positive and negative logic
options are available)
• Remote sense for the output voltage compensates for output
distribution drops
Mechanical Features
• Output voltage trim permits custom voltages and voltage margining
• Industry standard eighth-brick pin-out configuration
• Size: 0.9” x 2.3” (22.9 x 58.4mm)
Safety Features
• Low Profile total height only 0.340” (8.64mm), permits better airflow
and smaller card pitch
• Total weight: 0.85oz (24g)
• Flanged pins designed to permit surface mount soldering (avoid wave
solder) using FPiP technique
• 2000V, 30MΩ input-to-output isolation provides input/output
ground separation
• UL 60950-1 recognized (US & Canada),basic insulation rating
• TUV certified to EN60950-1
Protection Features
• Board and plastic components meet UL94V-0 flammability requirements
• Input under-voltage lockout disables converter at low input
voltage conditions
CONTENTS
• Output current limit and short circuit protection protects converter and
load from permanent damage and consequent hazardous conditions
• Active back bias limit prevents damage to converter from external load
induced pre-bias
• Output over-voltage protection protects load from damaging voltages
• Thermal shutdown protects converter from abnormal
environmental conditions
Product # PQ60050EKx10
Phone 1-888-567-9596
Page No.
Mechanical Drawing - Open frame - EKA & EKL (low Profile) . . . . . . . . . 2
Mechanical Drawing - Encased . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
PQ60050EKx10 Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . 4-5
PQ60-EK Standards and Qualifications . . . . . . . . . . . . . . . . . . . . . . . . . 6
PQ60-EK Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-10
Application Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-14
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
www.synqor.com
Doc.# 005-0005191 Rev. A
07/13/09
Page 1
Technical
Specification
PQ60-EK Family
Mechanical Drawing - Open frame - EKA & EKL (low Profile)
TOP
.900
.600
[15.24 ]
.450
[11.43 ]
.300
[7.62 ]
.150
[3.81 ]
SIDE
[22.86 ]
EKA SIDE
.340 .014
[8.64
0.35]
OVERALL HEIGHT
.410 .014
[10.41
0.35]
OVERALL HEIGHT
8 7 6 5 4
EKL SIDE
.145
[3.68 ]
.145
[3.68 ]
2.30
[58.4 ]
2.00
[50.8 ]
.14
[3.6 ]
1
2
3
.15 [3.8 ]
.300 [7.62 ]
.600 [15.24 ]
0.051 .017
[1.3 0.43]
BOTTOMSIDE
CLEARANCE
.121 .017
[3.07
0.43]
BOTTOMSIDE
CLEARANCE
NOTES
PIN DESIGNATIONS
1) Pins 1-3, 5-7 are 0.040” (1.02mm) diameter, with 0.080” (2.03mm)
diameter standoff shoulders.
Pin
Name
Function
1
Vin(+)
Positive input voltage
3) Other pin extension lengths available. Recommended pin length is
0.03” (0.76mm) greater than the PCB thickness.
2
ON/OFF
4) All Pins: Material - Copper Alloy- Finish (RoHS 6/6) - Matte Tin over
Nickel plate
3
Vin(–)
2)
Pins 4 and 8 are 0.062” (1.57 mm) diameter with 0.100" (2.54 mm)
diameter standoff shoulders.
5) Undimensioned components are shown for visual reference only.
6) All dimensions in inches (mm) Tolerances: x.xx +/-0.02 in. (x.x
+/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm)
7) Weight: 0.85 oz (24 g) typical
Negative input voltage
4
Vout(–)
Negative output voltage
5
SENSE(–)
Negative remote sense1
6
TRIM
7
8) Workmanship: Meets or exceeds IPC-A-610C Class II
TTL input to turn converter on
and off, referenced to Vin(–), with
internal pull up.
Output voltage trim2
SENSE(+) Positive remote sense3
8
Vout(+)
Positive output voltage
9) The flanged pins are designed to permit surface mount soldering
(allowing to avoid the wave soldering process) through the use of the
flanged pin-in-paste technique.
Notes:
10) UL/TUV standards require a clearance greater than 0.04” (1.02mm)
between input and output for Basic insulation. This issue should be
considered if any copper traces are on the top side of the user’s
board. Note that the ferrite core shown at left above is considered
part of the input/primary circuit.
2) Leave TRIM pin open for nominal output voltage.
Product # PQ60050EKx10
Phone 1-888-567-9596
www.synqor.com
1) SENSE(–) should be connected to Vout(–)
either remotely or at the converter.
3) SENSE(+) should be connected to Vout(+)
either remotely or at the converter.
Doc.# 005-0005191 Rev. A
07/13/09
Page 2
Technical
Specification
PQ60-EK Family
Mechanical Drawing - Encased
.986±0.020
(25.04±0.5)
Top View
Side View
0.600 (15.24)
0.450 (11.43)
0.300 (7.62)
0.150 (3.81)
0.500 ± 0.025
(12.7 ± 0.63)
Overall Height
8 7 6 5 4
2.386±0.020
(60.6±0.5)
2.00
(50.8)
0.183±0.020
(4.65±0.5)
1
2
3
0.193±0.020 (4.9±0.5)
0.300 (7.62)
0.600 (15.24)
0.180±.010
(4.57±0.25)
PIN DESIGNATIONS
NOTES
1)
Pins 1-3, 5-7 are 0.040” (1.02mm) diameter, with 0.080” (2.03mm)
diameter standoff shoulders.
2)
Pins 4 and 8 are 0.062” (1.57 mm) diameter with 0.100" (2.54 mm)
diameter standoff shoulders.
3)
Other pin extension lengths available. Recommended pin length is
0.03” (0.76mm) greater than the PCB thickness.
4)
All Pins: Material - Copper Alloy- Finish (RoHS 6/6) - Matte Tin over
Nickel plate
Pin
Name
Function
1
Vin(+)
Positive input voltage
2
ON/OFF
TTL input to turn converter on
and off, referenced to Vin(–), with
internal pull up.
3
Vin(–)
4
Vout(–)
Negative output voltage
Negative input voltage
Negative remote sense1
5)
Undimensioned components are shown for visual reference only.
6)
All dimensions in inches (mm) Tolerances: x.xx +/-0.02 in. (x.x
+/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm)
5
SENSE(–)
6
TRIM
7)
Weight: 5 oz (142 g) typical
7
SENSE(+)
Positive remote sense3
8)
Workmanship: Meets or exceeds IPC-A-610C Class II
8
Vout(+)
Positive output voltage
9)
The flanged pins are designed to permit surface mount soldering
(allowing to avoid the wave soldering process) through the use of the
flanged pin-in-paste technique.
Product # PQ60050EKx10
Phone 1-888-567-9596
www.synqor.com
Output voltage trim2
Notes:
1) SENSE(–) should be connected to Vout(–) either
remotely or at the converter.
2) Leave TRIM pin open for nominal output voltage.
3) SENSE(+) should be connected to Vout(+) either
remotely or at the converter.
Doc.# 005-0005191 Rev. A
07/13/09
Page 3
Input:
Output:
Current:
Part No.:
Technical Specification
35-75V
5V
10A
PQ60050EKx10
PQ60050EKx10 Electrical Characteristics
Ta = 25 °C, airflow rate = 300 LFM, Vin = 48V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max.
Units Notes & Conditions
ABSOLUTE MAXIMUM RATINGS
Input Voltage
Non-Operating
Operating
35
Operating Transient Protection
100
V
Continuous
75
V
Continuous
100
V
100ms transient,square wave
Isolation Voltage
2000
V dc
Operating Temperature
Input to Output
-40
100
°C
Storage Temperature
-55
125
°C
0
13.5
V
Voltage at ON/OFF input pin
Basic Insulation
INPUT CHARACTERISTICS
Operating Input Voltage Range
35
48
75
V
33.0
31.5
1.2
34.0
32.3
1.7
35.0
33.5
2.2
V
V
V
See Note 1
A
100% Load, 35V Vin, nominal Vout
Input Under-Voltage Lockout
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Lockout Voltage Hysteresis
Maximum Input Current
1.7
No-Load Input Current
78
Disabled Input Current
7.7
Inrush Current Transient Rating
mA
mA
0.02
A2s
Response to Input Transient
93
mV
1000V/ms input transient
Input Reflected Ripple Current
1
mA
RMS thru 10μH inductor; Figures 13 & 15
Input Terminal Ripple Current
57
mA
RMS; Figures 13 & 14
Recommended Input Fuse
20
Recommended External Input Capacitance
Input Filter Component Values (L\C)
A
Fast acting external fuse recommended
47
µF
Typical ESR 0.1-0.2 Ω; Figure 13
1/2.35
µH/µF
Internal values; see Figure E
OUTPUT CHARACTERISTICS
Output Voltage Set Point
4.95
5
5.05
V
Output Voltage Regulation
Over Line
±0.1/5
%/mV
Over Load
±0.15/7.5
%/mV
Over Temperature
±20
Total Output Voltage Range
4.9
5.0
mV
5.1
V
Output Voltage Ripple and Noise
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 2
Peak-to-Peak
28
mV
Full load;see Figure 13 & 16
RMS
8
mV
Full load;see Figure 13 & 16
Operating Output Current Range
0.0
Output DC Current-Limit Inception
10.5
10.0
12.5
A
A
Subject to thermal derating; Figures 5 - 8
Norminal Vout
Output DC Current-Limit Shutdown Voltage
4.8
V
Back-Drive Current Limit while Enabled
6.2
A
Negative current drawn from output
Back-Drive Current Limit while Disabled
2.2
mA
Negative current drawn from output
mF
Nominal Vout at full load (resistive load)
Maximum Output Capacitance Electrolytic
2.5
EFFICIENCY
100% Load
87.5
%
Figures 1 - 4
50% Load
87
%
Figures 1 - 4
Product # PQ60050EKx10
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005191 Rev. A
07/13/09
Page 4
Input:
Output:
Current:
Part No.:
Technical Specification
35-75V
5V
10A
PQ60050EKx10
PQ60050EKx10 Electrical Characteristics
Ta = 25 °C, airflow rate = 300 LFM, Vin = 48V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max.
Units Notes & Conditions
DYNAMIC CHARACTERISTICS
Input Voltage Ripple Rejection
75
dB
Step Change in Output Current (0.1 A/µs)
350
mV
50% to 75% to 50% Iout max; Figure 11
Step Change in Output Current (1 A/µs)
150
mV
50% to 75% to 50% Iout max; Figure 12
Settling time
350
µs
To within 1% Vout nom
ms
Full load, Vout=90% nom; Figures 9 & 10
ms
-40°C to 125°C; Figure F
%
Maximum Output Capacitance,Iout=0A
2000
V
See Absolute Maximum Ratings
30
MΩ
1000
pF
Output Voltage during Load Current Transient
120 Hz
See Note 3
Turn-On Transient
Turn-On Time
24
Start-Up Inhibit Time
180
200
Output Voltage Overshoot
240
0
ISOLATION CHARACTERISTICS
Isolation Voltage (dielectric strength)
Isolation Resistance
Isolation Capacitance (input to output)
See Note 4
TEMPERATURE LIMITS FOR POWER DERATING CURVES
Semiconductor Junction Temperature
125
°C
Package rated to 150 °C
Board Temperature
125
°C
UL rated max operating temp 130 °C
Transformer Temperature
125
°C
330
kHz
FEATURE CHARACTERISTICS
Switching Frequency
270
300
ON/OFF Control (Option P)
Off-State Voltage
0
0.8
V
On-State Voltage
2
13.5
V
Off-State Voltage
2
13.5
V
On-State Voltage
0
0.8
V
6
V
ON/OFF Control (Option N)
ON/OFF Control (Either Option)
Application notes; Figures A & B
Pull-Up Voltage
5
Pull-Up Resistance
10
Output Voltage Trim Range
-10
Output Voltage Remote Sense Range
kΩ
10
%
Measured across Pins 8 & 4; Figure C
10
%
Measured across Pins 8 & 4
Output Over-Voltage Protection
126
%
Over full temp range; % of nominal Vout
Over-Temperature Shutdown
125
°C
Average PCB Temperature
Over-Temperature Shutdown Restart Hysteresis
10
°C
RELIABILITY CHARACTERISTICS
Calculated MTBF (Telcordia)
2.5
Calculated MTBF (MIL-217)
1.1
Field Demonstrated MTBF
106 Hrs. TR-NWT-000332; 80% load, 300LFM, 40 °C Ta
106 Hrs. MIL-HDBK-217F; 80% load, 300LFM, 40 °C Ta
106 Hrs. See our website for details
Note 1: The UVLO values represented here are typical of lighter load conditions. The unit may shut down under high load conditions before the typical
UVLO limits.
Note 2: For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected])
Note 3: The module requires a minimum amount of capacitance (100μF) in order to ride through a No Load to Full Load transient (0.1A/μs) without
shutdown.
Note 4: Higher values of isolation capacitance can be added external to the module.
Product # PQ60050EKx10
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005191 Rev. A
07/13/09
Page 5
Input:
Output:
Current:
Part No.:
Technical Specification
35-75V
5V
10A
PQ60050EKx10
PQ60-EK Standards and Qualifications
Parameter
Notes & Conditions
STANDARDS COMPLIANCE
UL 60950-1:2003
File #E194341;Basic Insulation
CAN/CSA-C22.2 No. 60950-1:2003
EN60950-1:2001
Certified by TUV
Needle Flame Test (IEC 695-2-2)
Test on entire assembly; board & plastic components UL94V-0 compliant
IEC 61000-4-2
ESD test, 8 kV - NP, 15 kV air - NP (Normal Performance)
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new releases or
download from the SynQor website.
Parameter
# Units Test Conditions
QUALIFICATION TESTING
Life Test
32
95% rated Vin and load, units at derating point, 1000 hours
Vibration
5
10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis
Mechanical Shock
5
100g minimum, 2 drops in x and y axis, 1 drop in z axis
Temperature Cycling
10
-40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles
Power/Thermal Cycling
5
Toperating = min to max, Vin = min to max, full load, 100 cycles
Design Marginality
5
Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load
5
85 °C, 85% RH, 1000 hours, continuous Vin applied except 5 min/day
Humidity
Solderability
Product # PQ60050EKx10
15 pins
MIL-STD-883, method 2003
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005191 Rev. A
07/13/09
Page 6
Input:
Output:
Current:
Part No.:
Technical Specification
100
35-75V
5V
10A
PQ60050EKx10
89.0
95
88.5
88.0
85
Efficiency (%)
Efficiency (%)
90
80
75
70
87.5
87.0
35 Vin
25º C
48 Vin
65
40º C
86.5
75 Vin
55º C
60
0
2
4
6
8
86.0
100
10
Load Current (A)
200
300
400
Air Flow (LFM)
Figure 2: Efficiency at nominal output voltage and 60% rated power vs.
airflow rate for ambient air temperatures of 25°C, 40°C, and 55°C (nominal
input voltage).
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
6
10
Power Dissipation (W)
Power Dissipation (W)
8
6
4
35 Vin
2
2
4
6
4
3
25º C
48 Vin
40º C
75 Vin
55º C
0
0
5
8
2
100
10
Load Current (A)
200
300
400
Air Flow (LFM)
Figure 3: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
Figure 4: Power dissipation at nominal output voltage and 60% rated power
vs. airflow rate for ambient air temperatures of 25°C, 40°C, and 55°C (nominal
input voltage).
12
10
Iout (A)
8
6
4
400
300
200
100
2
LFM (2.0
LFM (1.5
LFM (1.0
LFM (0.5
m/s)
m/s)
m/s)
m/s)
0
25
40
55
70
Semiconductor junction temperature is
within 1°C of surface temperature
85
Ambient Air Temperature (ºC)
Figure 5: Maximum output power derating curves vs. ambient air temperature
for airflow rates of 100 LFM through 400 LFM with air flowing from pin 3 to pin
1 (nominal input voltage).
Product # PQ60050EKx10
Phone 1-888-567-9596
Figure 6: Thermal plot of converter at 10 amp load current (50W) with
55°C air flowing at the rate of 200 LFM. Air is flowing from pin 3 to pin 1
(nominal input voltage).
www.synqor.com
Doc.# 005-0005191 Rev. A
07/13/09
Page 7
Input:
Output:
Current:
Part No.:
Technical Specification
35-75V
5V
10A
PQ60050EKx10
12
10
Iout (A)
8
6
400
300
200
100
4
2
LFM (2.0
LFM (1.5
LFM (1.0
LFM (0.5
m/s)
m/s)
m/s)
m/s)
0
25
40
55
70
Semiconductor junction temperature is
within 1°C of surface temperature
85
Ambient Air Temperature (ºC)
Figure 7: Maximum output power derating curves vs. ambient air temperature
for airflow rates of 100 LFM through 400 LFM with air flowing across the
converter from input to output (nominal input voltage).
Figure 8: Thermal plot of converter 10 A load current (50 W) with 55°C air
flowing at the rate of 200 LFM. Air is flowing across the converter from input to
output (nominal input voltage).
Figure 9: : Turn-on transient at full load (resistive load) (10 ms/div). Load cap:
15µF tantalum capacitor and 1uF ceramic cap. Input voltage pre-applied. Ch 1:
Vout (2V/div). Ch 2: ON/OFF input (5 V/div).
Figure 10: : Turn-on transient at zero load (10 ms/div). Load cap: 15µF
tantalum capacitor and 1uF ceramic cap. Ch 1: Vout (2V/div), Ch 2: ON/OFF
input (5 V/div)
Figure 11:Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF
ceramic cap. Ch 1: Vout (500mV/div), Ch 2: Iout (5A/div).
Figure 12: Output voltage response to step-change in load current (50%-75%50% of Iout(max): dI/dt = 1A/µs). Load cap: 470µF, 30 mΩ ESR tantalum cap
and 1µF ceramic cap. Ch 1: Vout (500mV/div), Ch 2: Iout (5A/div).
Product # PQ60050EKx10
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005191 Rev. A
07/13/09
Page 8
Input:
Output:
Current:
Part No.:
Technical Specification
35-75V
5V
10A
PQ60050EKx10
See Fig. 15
10 µH
source
impedance
See Fig. 14
See Fig. 16
iS
VSOURCE
iC
47 µF,
<1W ESR
electrolytic
capacitor
DC/DC
Converter
VOUT
1 µF
15 µF,
ceramic 100mW ESR
capacitor
tantalum
capacitor
Figure 13: Test set-up diagram showing measurement points for Input Terminal
Ripple Current (Figure 14), Input Reflected Ripple Current (Figure 15) and
Output Voltage Ripple (Figure 16).
Figure 14: Input Terminal Ripple Current, ic, at full rated output current and
nominal input voltage with 10µH source impedance and 47µF electrolytic
capacitor (100 mA/div). See Figure 13.
Figure 15: Input reflected ripple current, is, through a 10 µH source inductor,
using a 47µF electrolytic input capacitor (5mA/div). See Figure 13.
Figure 16: Output voltage ripple at nominal input voltage and rated load current
(20 mV/div). Load capacitance: 1µF ceramic capacitor and 15µF tantalum
capacitor. Bandwidth: 20 MHz. See Figure 13.
12
11
10
Vout Trim-up (%)
9
8
7
6
5
4
3
100% Load
2
50% Load
1
0% Load
0
40.0
39.5
39.0
38.5
38.0
37.5
37.0
36.6
36.0
35.5
35.0
Input Voltage (V)
Figure 17: Output voltage response to step-change in input voltage(48V to
75V),at 10A load current.Load cap:15uF tantulum capacitor and 1 uF ceramic
cap. Ch1:Vout(100mV/div), Ch2: Vin(50V/div)
Product # PQ60050EKx10
Phone 1-888-567-9596
Figure 18: Achievable trim-up percentage vs. input voltage at 0%, 50% and full
load. Vin=35-40V.
www.synqor.com
Doc.# 005-0005191 Rev. A
07/13/09
Page 9
Input:
Output:
Current:
Part No.:
Technical Specification
Forward Transmission (dB)
Output Impedance (ohms)
1
0.1
0.01
35 Vin
48 Vin
75 Vin
0.001
0.0001
10
100
1,000
10,000
35-75V
5V
10A
PQ60050EKx10
0
-5
-10
-15
-20
-25
-30
-35
-40
-45
-50
-55
-60
-65
-70
-75
-80
-85
-90
-95
-100
100,000
35 Vin
48 Vin
75 Vin
10
100
Hz
1,000
10,000
100,000
Hz
Figure 19: Magnitude of incremental output impedance (Zout = Vout/Iout) for
minimum, nominal, and maximum input voltage at full rated power.
Figure 20: Magnitude of incremental forward transmission (FT = Vout/Vin) for
minimum, nominal, and maximum input voltage at full rated power.
5
100
Input Impedance (ohms)
Reverse Transmission (dB)
-5
-15
-25
-35
35 Vin
48 Vin
75 Vin
-45
10
1
36 Vin
48 Vin
75 Vin
0.1
-55
10
100
1,000
10,000
10
100,000
Hz
100
1,000
10,000
100,000
Hz
Figure 21: Magnitude of incremental reverse transmission (RT = Iin/Iout) for
minimum, nominal, and maximum input voltage at full rated power.
Figure 22: Magnitude of incremental input impedance (Zin = Vin/Iin) for
minimum, nominal, and maximum input voltage at full rated power.
Output Voltage (V)
6
4
35 Vin
48 Vin
75 Vin
2
0
0
5
10
15
Load Current (A)
Figure 23: Output voltage vs. load current showing typical current limit curves
and converter shutdown points
Product # PQ60050EKx10
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005191 Rev. A
07/13/09
Page 10
Input:
Output:
Current:
Part No.:
Technical Specification
BASIC OPERATION AND FEATURES
The single stage power converter switches at a fixed
frequency for predictable EMI performance. Rectification of
the transformer’s output is accomplished with synchronous
rectifiers. These devices, which are MOSFETs with a very low
on-state resistance, dissipate far less energy than Schottky
diodes. This is the primary reason that the PowerQor
converter has such high efficiency, even at very low output
voltages and very high output currents.
Dissipation throughout the converter is so low that it does
not require a heatsink for operation. Since a heatsink is not
required, the PowerQor converter does not need a metal
baseplate or potting material to help conduct the dissipated
energy to the heatsink. The PowerQor converter can thus be
built more simply and reliably using high yield surface mount
techniques on a PCB substrate.
The PowerQor series of eighth-brick, quarter-brick and halfbrick converters uses the industry standard footprint and
pin-out configuration.
CONTROL FEATURES
REMOTE ON/OFF (Pin 2): The ON/OFF input, Pin 2, permits
the user to control when the converter is on or off. This input is
referenced to the return terminal of the input bus, Vin(-). There
are two versions of the converter that differ by the sense of the
logic used for the ON/OFF input.
In the positive logic version, the ON/OFF input is active high
(meaning that a high turns the converter on). In the negative
logic version, the ON/OFF signal is active low (meaning that a
low turns the converter on). Figure A details five possible circuits
for driving the ON/OFF pin. Figure B is a detailed look of the
internal ON/OFF circuitry.
REMOTE SENSE(+) (Pins 7 and 5): The SENSE(+) inputs
correct for voltage drops along the conductors that connect the
converter’s output pins to the load.
Pin 7 should be connected to Vout(+) and Pin 5 should be
connected to Vout(-) at the point on the board where regulation
is desired. A remote connection at the load can adjust for a
voltage drop only as large as that specified in this datasheet,
that is
[Vout(+) - Vout(-)] – [Vsense(+) - Vsense(-)] <
Sense Range % x Vout
Pins 7 and 5 must be connected for proper regulation of
the output voltage. If these connections are not made, the
converter will deliver an output voltage that is slightly higher
than its specified value.
Note: the output over-voltage protection circuit senses the
voltage across the output (pins 8 and 4) to determine when
it should trigger, not the voltage across the converter’s sense
leads (pins 7 and 5). Therefore, the resistive drop on the board
should be small enough so that output OVP does not trigger,
even during load transients.
ON/OFF
ON/OFF
ON/OFF
Vin(_)
Vin(_)
Vin(_)
Remote Enable Circuit
Negative Logic
(Permanently Enabled)
ON/OFF
5V
10k
ON/OFF
50k
TTL
ON/OFF
Vin(_)
Vin(_)
100pF
Vin(_)
Direct Logic Drive
Figure A: Various circuits for driving the ON/OFF pin.
Product # PQ60050EKx10
5V
Positive Logic
(Permanently Enabled)
TTL/
CMOS
Open Collector Enable Circuit
35-75V
5V
10A
PQ60050EKx10
Phone 1-888-567-9596
www.synqor.com
Figure B: Internal ON/OFF pin circuitry
Doc.# 005-0005191 Rev. A
07/13/09
Page 11
Input:
Output:
Current:
Part No.:
Technical Specification
OUTPUT VOLTAGE TRIM (Pin 6): The TRIM input permits the
user to adjust the output voltage across the sense leads up or
down according to the trim range specifications.
To decrease the output voltage, the user should connect a
resistor between Pin 6 and Pin 5 (SENSE(-) input). For a desired
decrease of the nominal output voltage, the value of the resistor
should be
Rtrim-down =
( 511
∆%)
- 10.22 (kW)
where
∆% =
Vnominal – Vdesired
Vnominal
x 100%
To increase the output voltage, the user should connect a
resistor between Pin 6 and Pin 7 (SENSE(+) input). For a desired
increase of the nominal output voltage, the value of the resistor
should be
Rtrim-up =
(
5.11VOUT(100+∆%) _ 511 _
10.22
1.225∆%
∆%
)
(kW)
where
VOUT = Nominal Output Voltage
Figure C graphs the relationship between the trim resistor value
and Rtrim-up and Rtrim-down, showing the total range the
output voltage can be trimmed up or down.
Note: the TRIM feature does not affect the voltage at which the
output over-voltage protection circuit is triggered. Trimming the
output voltage too high may cause the over-voltage protection
circuit to engage, particularly during transients.
It is not necessary for the user to add capacitance at the Trim
pin. The node is internally bypassed to eliminate noise.
Trim Resistance (kOhms)
100,000
35-75V
5V
10A
PQ60050EKx10
Total DC Variation of Vout: For the converter to meet its
full specifications, the maximum variation of the DC value of
Vout, due to both trimming and remote load voltage drops,
should not be greater than that specified for the output
voltage trim range.
PROTECTION FEATURES
Input Under-Voltage Lockout: The converter is designed
to turn off when the input voltage is too low, helping avoid an
input system instability problem, described in more detail in the
application note titled “Input System Instability”. The lockout
circuitry is a comparator with DC hysteresis. When the input
voltage is rising, it must exceed the typical Turn-On Voltage
Threshold value (listed on the specification page) before the
converter will turn on. Once the converter is on, the input
voltage must fall below the typical Turn-Off Voltage Threshold
value before the converter will turn off.
Output Current Limit: Once the output current reaches the
current-limit point, the converter is in the cycle-by-cycle current
limit mode for a short time that the typical value is 210µs. If the
over current no longer exists during this short time, the converter
resumes the normal condition. If the over current still persists
after this short time, the converter enters a “hiccup mode” where
it repeatedly turns on and off at a 5 Hz (nominal) frequency until
the over current condition is removed. The dual advantages of
this design are that a short term overload will not cause a hiccup
mode restart and it prevents excessive heating of the converter
or the load board in extended over current condition.
Output Over-Voltage Limit: If the voltage across the output
pins exceeds the Output Over-Voltage Protection threshold, the
converter will immediately stop switching. This prevents damage
to the load circuit due to 1) excessive series resistance in output
current path from converter output pins to sense point, 2) a
release of a short-circuit condition, or 3) a release of a current
limit condition. Load capacitance determines exactly how high
the output voltage will rise in response to these conditions. After
200 ms the converter will automatically restart.
Over-Temperature Shutdown: A temperature sensor on
the converter senses the average temperature of the module.
The thermal shutdown circuit is designed to turn the converter
off when the temperature at the sensed location reaches the
Over-Temperature Shutdown value. It will allow the converter
to turn on again when the temperature of the sensed location
falls by the amount of the Over-Temperature Shutdown Restart
Hysteresis value.
10,000
1,000
100
10
1
0
1
2
3
4
% increase Vout
5
6
7
8
9
10
% decrease Vout
Figure C: Trim Graph for 5Vout module
Figure C: Trim Graph for 1.8Vout module
Product # PQ60050EKx10
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005191 Rev. A
07/13/09
Page 12
Input:
Output:
Current:
Part No.:
Technical Specification
APPLICATION CONSIDERATIONS
Input System Instability: This condition can occur because
any DC/DC converter appears incrementally as a negative
resistance load. A detailed application note titled “Input System
Instability” is available on the SynQor website which provides
an understanding of why this instability arises, and shows the
preferred solution for correcting it.
Application Circuits: Figure D below provides a typical circuit
diagram which details the input filtering and voltage trimming.
Input Filtering and External Capacitance: Figure E below
provides a diagram showing the internal input filter components.
This filter dramatically reduces input terminal ripple current,
which otherwise could exceed the rating of an external
input electrolytic capacitor. The recommended external input
capacitance is specified in the “Input Characteristics” section.
More detailed information is available in the application note
titled “EMI Characteristics” on the SynQor website.
Startup Inhibit Period: The Startup Inhibit Period ensures
that the converter will remain off for approximately 200ms
when it is shut down for any reason. In all, there are five ways
that the converter can be shut down, initiating a Startup Inhibit
Period:
• Input Under-Voltage Lockout
• Output Over-Voltage Protection
• Over Temperature Shutdown
• Current Limit
• Turned off by the ON/OFF input
Vin(+)
Vin
External
Input
Filter
Vout(+)
Vsense(+)
Electrolytic
Capacitor
47µF
35-75V
5V
10A
PQ60050EKx10
ON/OFF
Trim
Vsense(_)
Vin(_)
Rtrim-up
or
Rtrim-down
Cload
Iload
Vout(_)
Figure D: Typical application circuit (negative logic unit, permanently enabled).
L
Vin(+)
C
Vin(_)
Figure E: Internal Input Filter Diagram (component values listed on the specifications page).
Product # PQ60050EKx10
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005191 Rev. A
07/13/09
Page 13
Input:
Output:
Current:
Part No.:
Technical Specification
35-75V
5V
10A
PQ60050EKx10
Figure F shows three turn-on scenarios, where a Startup Inhibit
Period is initiated at t0, t1, and t2:
At time t1, the unit is disabled by the ON/OFF pin, and it cannot
be enabled again until the Startup Inhibit Period has elapsed.
Before time t0, when the input voltage is below the UVL threshold,
the unit is disabled by the Input Under-Voltage Lockout feature.
When the input voltage rises above the UVL threshold, the
Input Under-Voltage Lockout is released, and a Startup Inhibit
Period is initiated. At the end of this delay, the ON/OFF pin is
evaluated, and since it is active, the unit turns on.
When the ON/OFF pin goes high after t2, the Startup Inhibit
Period has elapsed, and the output turns on within the typical
Turn-On Time.
Vin
Under-Voltage
Lockout
Turn-On
Threshold
ON/OFF
(pos logic)
ON
OFF
ON
OFF
ON
15ms
24ms
(typical turn on time)
Vout
10ms
(typical start-up
inhibit period)
200ms
200ms
t
t0
t1
t2
Figure F: Startup Inhibit Period (turn-on time not to scale)
Product # PQ60050EKx10
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005191 Rev. A
07/13/09
Page 14
Input:
Output:
Current:
Part No.:
Technical Specification
35-75V
5V
10A
PQ60050EKx10
PART NUMBERING SYSTEM
ORDERING INFORMATION
The part numbering system for SynQor’s dc-dc converters
follows the format shown in the example below.
The tables below show the valid model numbers and ordering
options for converters in this product family. When ordering
SynQor converters, please ensure that you use the complete
15 character part number consisting of the 12 character base
part number and the additional 3 characters for options.
Add “-G” to the model number for 6/6 RoHS compliance.
PQ 6 0 0 5 0 E K C 1 0 N R S - G
6/6 RoHS
Options (see
Ordering Information)
Output Current
Thermal Design
Performance Level
Model Number
Input
Voltage
Output
Voltage
Max Output
Current
PQ60050EKw10xyz
35V-75V
5V
10A
The following options must be included in place of the w x y z
spaces in the model numbers listed above.
Package Size
Output Voltage
Options Description: w x y z
Input Voltage
Product Family
The first 12 characters comprise the base part number and
the last 3 characters indicate available options. The “-G”
suffix indicates 6/6 RoHS compliance.
Application Notes
A variety of application notes and technical white papers can
be downloaded in pdf format from our website.
RoHS Compliance: The EU led RoHS (Restriction of Hazardous
Substances) Directive bans the use of Lead, Cadmium,
Hexavalent Chromium, Mercury, Polybrominated Biphenyls
(PBB), and Polybrominated Diphenyl Ether (PBDE) in Electrical
and Electronic Equipment. This SynQor product is 6/6 RoHS
compliant. For more information please refer to SynQor’s
RoHS addendum available at our RoHS Compliance / Lead Free
Initiative web page or e-mail us at [email protected].
Thermal Design
Enable Logic
Pin Style
Feature Set
A - Open Frame
L - Low Profile
C - Encased
N - Negative P Positive
K - 0.110"
N - 0.145"
R - 0.180"
Y - 0.250"
S - Standard
Not all combinations make valid part numbers, please contact
SynQor for availability. See the Product Summary web page for
more options.
PATENTS
SynQor holds the following U.S. patents, one or more of
which apply to this product. Additional patent applications
may be pending or filed in the future.
5,999,417
6,222,742 6,545,890 6,577,109
6,594,159 6,731,520
6,894,468 6,896,526
6,927,987 7,050,309
7,072,190 7,085,146
7,119,524
7,269,034
7,272,021
7,272,023
Contact SynQor for further information:
Phone:
Toll Free:
Fax:
E-mail:
Web:
Address:
Product # PQ60050EKx10
978-849-0600
888-567-9596
978-849-0602
[email protected]
www.synqor.com
155 Swanson Road
Boxborough, MA 01719
USA
Phone 1-888-567-9596
Warranty
SynQor offers a three (3) year limited warranty. Complete warranty
information is listed on our website or is available upon request from SynQor.
Information furnished by SynQor is believed to be accurate and reliable.
However, no responsibility is assumed by SynQor for its use, nor for any
infringements of patents or other rights of third parties which may result
from its use. No license is granted by implication or otherwise under any
patent or patent rights of SynQor.
www.synqor.com
Doc.# 005-0005191 Rev. A
07/13/09
Page 15