For more information, please visit the product page. date 11/20/2015 page 1 of 11 SERIES: PPR-1U │ DESCRIPTION: RACK ACCESSORY FEATURES • up to 12,000 W continuous power • operation from a wide range AC input (90~260 Vac) incoming (Line-Neutral) AC source on a per module basis • 19” four slot power shelf • 48 or 54 Vdc output voltage (from PSE-3000 modules) • single or dual output configurations • integral forced cooling, from internal fans housed within the power modules • front to back & back to front airflow versions , I nc rt Rheinla . T o of N C 3.3 Vdc (2 A) standby voltage redundant (N+1) operation blind mate connections for hot-swap adjustable mounting brackets racks can share with on additional rack in a master slave arrangement • EMI filtering of the AC input directly in line with the IEC 320 inlet connetors to meet Class A performance • user accessible dip-switch for setting master or slave shelf nd UV • • • • • h A ca meri US MODEL1 output voltage1 airflow direction output configuration2 (Vdc) output power (max) 110 Vin (W) 220 Vin (W) PPR-1U 48 or 54 front to back single output, configuration A 6,000 12,000 PPR-1U-A 48 or 54 front to back dual output 6,000 12,000 PPR-1U-B 48 or 54 back to front single output, configuration A 5,400 12,000 PPR-1U-C 48 or 54 back to front dual output 5,400 12,000 PPR-1U-D 48 or 54 front to back single output, configuration B 6,000 12,000 PPR-1U-E 48 or 54 back to front single output, configuration B 5,400 12,000 Notes: 1. Rack assembly requires (4) PSE-3000-48 or PSE-3000-54 units (sold separately). Refer to the PSE-3000 datasheet for specification details. 2. See page 3 for configuration details. 3. All specifications measured at: Ta=25°C and 220 Vac input voltage unless otherwise specified. PART NUMBER KEY PPR-1U - X Rack Configuration “blank” = Front to Back Airflow, All Parallel, Single Output, A A = Front to Back Airflow, Dual Output B = Back to Front Airflow, All parallel, Single Output, A C = Back to Front Airflow, Dual Output D = Front to Back Airflow, All Parallel, Single Output, B E = Back to Front Airflow, All Parallel, Single Output, B Base Number cui.com For more information, please visit the product page. CUI Inc │ SERIES: PPR-1U │ DESCRIPTION: RACK ACCESSORY date 11/20/2015 │ page 2 of 11 POWER SHELF Shelf Power Power Shelf Model Number Power Module Model Number Airflow Direction 110 Vin 220 Vin Standby Output IEC Inlet Type PPR-1U PSE-3000-48-F or PSE-3000-54-F Front to Back 6,000 W 12,000 W All Parallel, single output, configuration A C22 PPR-1U-A PSE-3000-48-F or PSE-3000-54-F Front to Back 6,000 W 12,000 W dual output C22 PPR-1U-B PSE-3000-48-B or PSE-3000-54-B Back to Front 5,400 W 12,000 W All Parallel, single output configuration A C20 PPR-1U-C PSE-3000-48-B or PSE-3000-54-B Back to Front 5,400 W 12,000 W dual output C20 PPR-1U-D PSE-3000-48-F or PSE-3000-54-F Front to Back 6,000 W 12,000 W All Parallel, single output configuration B C22 PPR-1U-E PSE-3000-48-B or PSE-3000-54-B Back to Front 5,400 W 12,000 W All Parallel, single output configuration B C20 PPR-1U, PPR-1U-A, PPR-1U-D - FRONT TO BACK AIRFLOW PPR-1U-B, PPR-1U-C, PPR-1U-E - BACK TO FRONT AIRFLOW cui.com For more information, please visit the product page. CUI Inc │ SERIES: PPR-1U │ DESCRIPTION: RACK ACCESSORY date 11/20/2015 │ page 3 of 11 POWER SHELF (CONTINUED) PPR-1U & PPR-1U-B Output Terminal Block Configuration (Single Output, Configuration A) All 4 power modules wired in parallel inside the power shelf, 6 kW available from each output terminal block set + - + - PPR-1U-A & PPR-1U-C Output Terminal Block Configuration (Dual Output) Each terminal block wired to 2 power modules, 6 kW available from each output + - + - PPR-1U-D & PPR-1U-E Output Terminal Block Configuration (Single Output, Configuration B) All 4 power modules wired in parallel inside the power shelf, 6 kW available from each output terminal block set - + + cui.com For more information, please visit the product page. CUI Inc │ SERIES: PPR-1U │ DESCRIPTION: RACK ACCESSORY date 11/20/2015 │ page 4 of 11 MECHANICAL DRAWING PPR-1U, PPR-1U-A, PPR-1U-D - FRONT TO BACK AIRFLOW units: inches [mm] tolerance: ±0.02 [0.50] cui.com For more information, please visit the product page. CUI Inc │ SERIES: PPR-1U │ DESCRIPTION: RACK ACCESSORY date 11/20/2015 │ page 5 of 11 MECHANICAL DRAWING (CONTINUED) PPR-1U-B, PPR-1U-C, PPR-1U-E - BACK TO FRONT AIRFLOW units: inches [mm] tolerance: ±0.02 [0.50] cui.com For more information, please visit the product page. CUI Inc │ SERIES: PPR-1U │ DESCRIPTION: RACK ACCESSORY date 11/20/2015 │ page 6 of 11 MECHANICAL DRAWING (CONTINUED) Bracket Attachment The mounting brackets are factory attached in the flush position. The mounting brackets can be repositioned by customer, however the #6-32 mounting screws to be reattached with typical torque of 6 to 8 in-lbs. cui.com For more information, please visit the product page. CUI Inc │ SERIES: PPR-1U │ DESCRIPTION: RACK ACCESSORY date 11/20/2015 │ page 7 of 11 CONNECTIONS Back to Front Airflow Front to Back Airflow Chassis Grounding DC OUTPUT AC INPUT V Standby Output Connector A2 Address Switch D-Sub 9 I C communication The 2 D-Sub connector signals are parallel inside the power shelf 2 AC Line Cord Connection The power shelf is not shipped with AC line cords and the customer is responsible to provide its own AC line cords to meet the respective local electrical code requirements. Chassis Grounding A ground stud is provided at the rear of the power shelf as shown below. Earth ground stud nut #10-32 to be torqued 16 to 19 in-lbs typical. cui.com For more information, please visit the product page. CUI Inc │ SERIES: PPR-1U │ DESCRIPTION: RACK ACCESSORY date 11/20/2015 │ page 8 of 11 CONNECTIONS (CONTINUED) DC Output Cable Connection The Output and Return Cables (#2 AWG wire on 1/4” stud - not provided) connected to output studs provided at the rear of the power shelf as shown below. Standby Output Connections V Standby Output Connector, Mating Connector Molex 39-01-2020, terminals 39-00-0038 Connector - Pin# Signal Name Function 1 (lower position) +3.3 STANDBY +3.3 VDC +VE Output 2 (upper position) +3.3 STANDBY RTN +3.3 VDC –VE Output Signal Interface Connections (System to Shelf; Shelf to Shelf): The shelf signals are provided with a 9 Pin female D-SUB connector for system communication and another 9 Pin female D-SUB connector for shelf to shelf communication: D-SUB 9 pin System to Shelf Shelf to Shelf SDA 1 Yes Yes SCL 2 Yes Yes Not used 3 -- -- Vpgm 4 Yes Yes Vpgm Return 5 Yes Yes Digital Return 6 Yes Yes SMB Alert 7 Yes Yes Not used 8 -- -- I-Share 9 Yes Yes cui.com For more information, please visit the product page. CUI Inc │ SERIES: PPR-1U │ DESCRIPTION: RACK ACCESSORY date 11/20/2015 │ page 9 of 11 CONNECTIONS (CONTINUED) A2 Address Switch Connections Address A2 Address Switch Down Up A2 A1 A0 Slot 1 0 0 0 Slot 2 0 0 1 Slot 3 0 1 0 Slot 4 0 1 1 Slot 1 1 0 0 Slot 2 1 0 1 Slot 3 1 1 0 Slot 4 1 1 1 Slot 1 Slot 2 Slot 3 cui.com Slot 4 For more information, please visit the product page. CUI Inc │ SERIES: PPR-1U │ DESCRIPTION: RACK ACCESSORY date 11/20/2015 │ page 10 of 11 ACCESSORIES The PPR-1U Series requires the following additional accessories that can be purchased separately or as a kit. Description QTY CUI Part Number Vendor/Part Number AC power line cordset, C22 type 4 Schurter C21.6051.5002 AC power line cordset, C20 type 4 Schurter C19.6009.5195 Aux Output Mating Connector 1 Molex 39-01-2020 Aux Output Contact Terminal 2 Molex 46055-0007 I C dongle 1 Microchip DV164122 I C dongle to D sub 9 cable 1 1 2 2 3 2 014-157401-4 Notes: 1. Used with PPR-1U, PPR-1U-A, PPR-1U-D 2. Used with PPR-1U-B, PPR-1U-C, PPR-1U-E 3. The PICkit Serial Analyzer is an USB-based tool used to direct communication between a PC and an external serial device. The kit comes complete with hardware (supporting I2C™, SMBus, SPI and USART protocols), an easy-to-use GUI (to configure and display communications) and a target demonstration board for out-of-the-box functionality. Accessory-kit-1 Description QTY Vendor/Part Number AC power line cordset, C22 type 4 Schurter C21.6051.5002 Aux Output Mating Connector 1 Molex 39-01-2020 Aux Output Contact Terminal 2 Molex 46055-0007 I C dongle 1 Microchip DV164122 I C dongle to D sub 9 cable 1 2 3 2 Notes: 1. Compatible with PPR-1U, PPR-1U-A, PPR-1U-D Accessory-kit-2 Description QTY Vendor/Part Number AC power line cordset, C20 type 4 Schurter C19.6009.5195 Aux Output Mating Connector 1 Molex 39-01-2020 Aux Output Contact Terminal 2 Molex 46055-0007 I C dongle 1 Microchip DV164122 I2C dongle to D sub 9 cable 1 2 Notes: 3 1. Compatible with PPR-1U-B, PPR-1U-C, PPR-1U-E cui.com For more information, please visit the product page. CUI Inc │ SERIES: PPR-1U │ DESCRIPTION: RACK ACCESSORY date 11/20/2015 │ page 11 of 11 REVISION HISTORY rev. 1.0 description date initial release 11/20/2015 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.