20A/24W

Technical
Specification
IQ18xxxSKXxxx
9-36 V
40 V
1.2-15 V
26 W
2250 Vdc
Sixteenth-brick
Outputs
Max Power
Isolation
DC-DC Converter
Continuous Input Transient Input
IQ
D 18
9- C - D 0 1
36 C 2 S
V
C K
IN
1. O N C 2
2V V 0
OU
E NR
T @ RT S20 E R G
A
The InQor® Sixteenth-brick converter series is
composed of next-generation, board-mountable,
isolated, fixed switching frequency dc-dc converters
that use synchronous rectification to achieve
extremely high power conversion efficiency. Each
module is supplied completely encased to provide
protection from the harsh environments seen in many
industrial and transportation applications.
Operational Features
•
•
•
•
•
High efficiency, up to 82% at full rated load current
Delivers full power with minimal derating
Operating input voltage range: 9-36 V with 40 V for 1 s transient
Fixed frequency switching provides predictable EMI
No minimum load requirement
Protection Features
Mechanical Features
•
•
•
•
Industry standard Sixteenth-brick pin-out configuration
Size: 1.436" x 1.036" x 0.500" (36.47 x 26.31 x 12.70 mm)
Total weight: 1.1 oz (31 g)
Flanged baseplate version available
•
•
•
•
•
Input under-voltage lockout
Output current limit and short circuit protection
Active back drive current limit
Output over-voltage protection
Thermal shutdown
Control Features
• On/Off control referenced to input side
• Remote sense for improved output voltage control
• Wide output voltage trim range
Safety Features
•
•
•
•
UL 60950-1:2007/A2:2014 Basic Insulation
CAN/CSA C22.2 No. 60950-1:2007/A2:2014
EN 60950-1:2006/A2:2013
RoHS compliant (see last page)
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
CONTENTS
Page No.
Family Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.2Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . . 4
1.5Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . . 6
1.8Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . . 8
2.5Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 10
3.3Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 12
5.0Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 14
7.0Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 16
12Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 18
15Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 20
Application Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Standards & Qualification Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Standard Mechanical Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Flanged Mechanical Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 1
Technical
Specification
IQ18xxxSKXxxx
IQ18-SK Family Electrical Characteristics (all output voltages)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 18 Vdc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max.
Units Notes & Conditions
ABSOLUTE MAXIMUM RATINGS
Input Voltage
Non-Operating
-1
50
V
Continuous
Operating
36
V
Continuous
Operating Transient
40
V
1s
Isolation Voltage
Input to Output
2250
Vdc
Input to Baseplate
2250
Vdc
Output to Baseplate
2250
Vdc
Operating Temperature
-40
100
°C
Baseplate temperature
Storage Temperature
-45
125
°C
Voltage at ON/OFF input pin
-2
8
V
INPUT CHARACTERISTICS
Operating Input Voltage Range
9
18
36
V
See Note 1
Input Under-Voltage Lockout
Turn-On Voltage Threshold
9.3
9.7
10.3
V
Turn-Off Voltage Threshold
7.9
8.4
8.9
V
Lockout Voltage Hysteresis
1.3
V
µF
Recommended External Input Capacitance
100
Typical ESR 0.1-0.2 Ω; see Note 4
Input Filter Component Values (L\C)
0.22\5
µH\µF Internal values; see Figure D
DYNAMIC CHARACTERISTICS
Turn-On Transient
Turn-On Time
35
ms
Full load, Vou= 90 % nom. (from enable)
Start-Up Inhibit Time
180
200
250
ms
Figure E; See Note 3
Power-Up Inhibit Time
2
ms
Figure E
Output Voltage Overshoot
0
%
Maximum Output Capacitance
ISOLATION CHARACTERISTICS
Isolation Voltage (dielectric strength)
See Absolute Maximum Ratings
Isolation Resistance
30
MΩ
Isolation Capacitance (input to output)
1000
pF
See Note 2
TEMPERATURE LIMITS FOR POWER DERATING CURVES
Semiconductor Junction Temperature
125
°C
Package rated to 150 °C
PCB Temperature
125
°C
UL rated max operating temp 130 °C
Transformer Temperature
125
°C
Maximum Baseplate Temperature, Tb
100
°C
FEATURE CHARACTERISTICS
Switching Frequency
350
kHz
ON/OFF Control
Off-State Voltage
2.4
8
V
On-State Voltage
-2
0.8
ON/OFF Control
Application notes Figures A & B
Pull-Up Voltage
5
V
Pull-Up Resistance
10
kΩ
Over-Temperature Shutdown OTP Trip Point
125
°C
Average PCB Temperature
Over-Temperature Shutdown Restart Hysteresis
10
°C
RELIABILITY CHARACTERISTICS
Calculated MTBF (Telcordia) TR-NWT-000332
3.90
106 Hrs. Tb = 70 °C
Calculated MTBF (MIL-217) MIL-HDBK-217F
3.50
106 Hrs. Tb = 70 °C
Field Demonstrated MTBF
106 Hrs. See our website for details
Note 1: Start-up guaranteed above 10.3 V, but will operate down to 9 V.
Note 2: Higher values of isolation capacitance can be added externally
to the module.
Note 3: Maximum value is 400 ms for DC current limit and short circuit fault conditions
Note 4: See “Input System Instability” in the Application Considerations section.
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 2
Technical
Specification
IQ18xxxSKXxxx
Family Figures (all output voltages)
10,000
Trim Resistance (kOhms)
Nominal Vout
% Decrease in Vout (All voltages)
1,000
100
10
0
1
2
3
4
5
6
7
8
9
10
9
10
% Decrease in Vout
Common Figure 1: Typical startup waveform. Input voltage pre-applied, ON/
OFF Pin on Ch 2.
Common Figure 2: Trim graph for trim down.
100,000
10,000
1.5 V
1.8 V
2.5 V
3.3 V
5V
Trim Resistance (kOhms)
Trim Resistance (kOhms)
1.2 V
1,000
100
10
1
1
2
3
4
5
6
Increase in Vout (%)
7
Common Figure 3: Trim graph for trim-up 1.2 to 3.3V outputs.
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
8
9
10
12 V
15 V
10,000
1,000
100
0
7V
0
1
2
3
4
5
6
Increase in Vout (%)
7
8
Common Figure 4: Trim graph for trim-up 5 to 15V outputs.
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 3
Input:9-36 V
Output:1.2 V
Current:20 A
Part No.:IQ18012SKx20
Technical Specification
IQ18012SKx20 Electrical Characteristics (1.2 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 18 Vdc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max.
Units Notes & Conditions
INPUT CHARACTERISTICS
Maximum Input Current
5.0
A
Vin min; trim up; in current limit
No-Load Input Current (enabled)
165
210
mA
Disabled Input Current
10
14
mA
Response to Input Transient
0.04
V
250 V/ms; see Figure 6
Input Terminal Ripple Current
175
mA
RMS
Recommended Input Fuse
20
A
Fast acting fuse recommended; see Note 4
OUTPUT CHARACTERISTICS
Output Voltage Set Point
1.188
1.200
1.212
V
Output Voltage Regulation
Over Line
±0.1
±0.3
%
Over Load
±0.1
±0.3
%
Over Temperature
-18
18
mV
Total Output Voltage Range
1.170
1.230
V
Over sample, line, load, temperature & life
Output Voltage Ripple and Noise
20 MHz bandwidth; see Note 1
Peak-to-Peak
35
70
mV
Full load
RMS
9
20
mV
Full load
A
Operating Output Current Range
0
20
Subject to thermal derating
Output DC Current Limit Inception
22.0
25.0
28.0
A
Back-Drive Current Limit while Enabled
1.3
A
Negative current drawn into output pins
Back-Drive Current Limit while Disabled
2
mA
Negative current drawn into output pins
Maximum Output Capacitance
10,000
µF
Vout nominal at full load (resistive load); See Note 2
Output Voltage during Load Current Transient
Step Change in Output Current (0. 1A/µs)
90
mV
50 % to 75 % to 50 % Iout max; see Figure 5
Settling Time
200
µs
To within 1 % Vout nom; see Figure 5
Output Voltage Trim Range
-10
10
%
Across Pins 8 & 4; Common Figures 3-4; see Note 3
Output Voltage Remote Sense Range
10
%
Across Pins 8 & 4
Output Over-Voltage Protection
1.4
1.6
1.8
V
Over full temp range
EFFICIENCY
100 % Load
75
%
See Figure 1 for efficiency curve
50 % Load
74
%
See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and
noise, consult SynQor applications support (e-mail: [email protected])
Note 2: Recommended minimum output capacitance is 100 uF
Note 3: Trim-up range is limited below 10 % at low line and full load. Contact SynQor applications support for more detail (email: [email protected])
Note 4: Safety certification requires the use of a fuse rated at or below this value.
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 4
Input:9-36 V
Output:1.2 V
Current:20 A
Part No.:IQ18012SKx20
Technical Specification
12
90
85
10
Power Dissipation (W)
Efficiency (%)
80
75
70
65
60
6
4
9 Vin
9 Vin
2
18 Vin
55
50
8
18 Vin
36 Vin
0
5
10
15
36 Vin
0
20
0
5
10
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25 °C.
20
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25 °C.
25
25
20
20
15
Iout (A)
Iout (A)
15
Load Current (A)
Load Current (A)
10
15
10
5
400 LFM (2.0 m/s)
5
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
0
100 LFM (0.5 m/s)
50
60
70
80
90
100
110
0
Baseplate Temperature (°C)
25
40
55
70
85
Ambient Air Temperature (°C)
Figure 3: Maximum load current vs. baseplate temperature when conductively
cooled. Note: The system design must provide a suitable thermal path that
maintains the baseplate temperature below 100 °C.
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from pin 3 to pin 1 (nominal input voltage).
Figure 5: Output voltage response in the SM version to step-change in load
current (50 % -75 % -50 % of Iout(max); dI/dt = 0.1 A/µs). Load cap: 100 µF
electrolytic cap and 1 µF ceramic cap. Ch 1: Vout (100 mV/div), Ch 2: Iout (10
A/div).
Figure 6: Output voltage response in the SM version to step-change in input
voltage (250 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1:
Vout (100 mV/div), Ch 2: Vin (20 V/div).
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 5
Input:9-36 V
Output:1.5 V
Current:16 A
Part No.:IQ18015SKx16
Technical Specification
IQ18015SKx16 Electrical Characteristics (1.5 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 18 Vdc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max.
Units Notes & Conditions
4.5
A
200
250
mA
10
14
mA
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current (enabled)
Disabled Input Current
Response to Input Transient
0.04
V
Input Terminal Ripple Current
175
mA
Recommended Input Fuse
20
A
1.500
1.515
V
±0.1
±0.3
%
±0.1
Vin min; trim up; in current limit
250 V/ms; see Figure 6
RMS
Fast acting fuse recommended; see Note 4
OUTPUT CHARACTERISTICS
Output Voltage Set Point
1.485
Output Voltage Regulation
Over Line
Over Load
Over Temperature
Total Output Voltage Range
±0.3
%
-23
23
mV
1.462
1.538
V
30
60
mV
Full load
5
10
mV
Full load
16
A
23.0
A
Output Voltage Ripple and Noise
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Peak-to-Peak
RMS
Operating Output Current Range
0
Output DC Current Limit Inception
17.0
20.0
Subject to thermal derating
Back-Drive Current Limit while Enabled
1.5
A
Negative current drawn into output pins
Back-Drive Current Limit while Disabled
2
mA
Negative current drawn into output pins
µF
Vout nominal at full load (resistive load); See Note 2
mV
50 % to 75 % to 50 % Iout max; see Figure 5
Maximum Output Capacitance
10,000
Output Voltage during Load Current Transient
Step Change in Output Current (0. 1A/µs)
75
Settling Time
80
Output Voltage Trim Range
-10
Output Voltage Remote Sense Range
Output Over-Voltage Protection
1.7
1.9
µs
To within 1 % Vout nom; see Figure 5
10
%
Across Pins 8 & 4; Common Figures 3-4; see Note 3
10
%
Across Pins 8 & 4
2.1
V
Over full temp range
%
See Figure 1 for efficiency curve
EFFICIENCY
100 % Load
77
50 % Load
72
%
See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and
noise, consult SynQor applications support (e-mail: [email protected])
Note 2: Recommended minimum output capacitance is 100 uF
Note 3: Trim-up range is limited below 10 % at low line and full load. Contact SynQor applications support for more detail (email: [email protected])
Note 4: Safety certification requires the use of a fuse rated at or below this value.
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 6
Input:9-36 V
Output:1.5 V
Current:16 A
Part No.:IQ18015SKx16
Technical Specification
10
90
9
85
8
Power Dissipation (W)
Efficiency (%)
80
75
70
65
60
18 Vin
0
4
8
12
5
4
3
9 Vin
18 Vin
1
36 Vin
50
6
2
9 Vin
55
7
0
16
36 Vin
0
4
8
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25 °C.
16
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25 °C.
18
18
16
16
14
14
12
12
10
Iout (A)
Iout (A)
12
Load Current (A)
Load Current (A)
8
6
10
8
6
4
400 LFM (2.0 m/s)
4
2
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
2
0
50
60
70
80
90
100
110
0
Baseplate Temperature (°C)
100 LFM (0.5 m/s)
25
40
55
70
85
Ambient Air Temperature (°C)
Figure 3: Maximum load current vs. baseplate temperature when conductively
cooled. Note: The system design must provide a suitable thermal path that
maintains the baseplate temperature below 100 °C.
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from pin 3 to pin 1 (nominal input voltage).
Figure 5: Output voltage response in the SM version to step-change in load
current (50 % -75 % -50 % of Iout(max); dI/dt = 0.1 A/µs). Load cap: 100 µF
electrolytic cap and 1 µF ceramic cap. Ch 1: Vout (100 mV/div), Ch 2: Iout (10
A/div).
Figure 6: Output voltage response in the SM version to step-change in input
voltage (250 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1:
Vout (100 mV/div), Ch 2: Vin (20 V/div).
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 7
Input:9-36 V
Output:1.8 V
Current:14 A
Part No.:IQ18018SKx14
Technical Specification
IQ18018SKx14 Electrical Characteristics (1.8 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 18 Vdc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max.
Units Notes & Conditions
5.0
A
225
280
mA
10
14
mA
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current (enabled)
Disabled Input Current
Response to Input Transient
0.04
V
Input Terminal Ripple Current
220
mA
Recommended Input Fuse
20
A
1.800
1.818
V
±0.1
±0.3
%
±0.1
Vin min; trim up; in current limit
250 V/ms; see Figure 6
RMS
Fast acting fuse recommended; see Note 4
OUTPUT CHARACTERISTICS
Output Voltage Set Point
1.782
Output Voltage Regulation
Over Line
Over Load
Over Temperature
Total Output Voltage Range
±0.3
%
-27
27
mV
1.755
1.845
V
35
70
mV
Full load
8
20
mV
Full load
14
A
19.0
A
Output Voltage Ripple and Noise
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Peak-to-Peak
RMS
Operating Output Current Range
0
Output DC Current Limit Inception
16.0
17.5
Subject to thermal derating
Back-Drive Current Limit while Enabled
1.8
A
Negative current drawn into output pins
Back-Drive Current Limit while Disabled
2
mA
Negative current drawn into output pins
µF
Vout nominal at full load (resistive load); See Note 2
mV
50 % to 75 % to 50 % Iout max; see Figure 5
Maximum Output Capacitance
10,000
Output Voltage during Load Current Transient
Step Change in Output Current (0. 1A/µs)
75
Settling Time
100
Output Voltage Trim Range
µs
To within 1 % Vout nom; see Figure 5
10
%
Across Pins 8 & 4; Common Figures 3-4; see Note 3
10
%
Across Pins 8 & 4
2.5
V
Over full temp range
%
See Figure 1 for efficiency curve
-10
Output Voltage Remote Sense Range
Output Over-Voltage Protection
2.1
2.3
EFFICIENCY
100 % Load
78
50 % Load
72
%
See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and
noise, consult SynQor applications support (e-mail: [email protected])
Note 2: Recommended minimum output capacitance is 100uF
Note 3: Trim-up range is limited below 10 % at low line and full load. Contact SynQor applications support for more detail (email: [email protected])
Note 4: Safety certification requires the use of a fuse rated at or below this value.
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 8
Input:9-36 V
Output:1.8 V
Current:14 A
Part No.:IQ18018SKx14
Technical Specification
12
90
85
10
Power Dissipation (W)
Efficiency (%)
80
75
70
65
60
9 Vin
50
6
4
9 Vin
2
18 Vin
55
8
18 Vin
36 Vin
0
2
4
6
8
10
12
36 Vin
0
14
0
2
4
6
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
10
12
14
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
16
16
14
14
12
12
10
10
Iout (A)
Iout (A)
8
Load Current (A)
Load Current (A)
8
6
8
6
4
2
0
50
60
70
80
90
100
110
4
400 LFM (2.0 m/s)
2
200 LFM (1.0 m/s)
0
Baseplate Temperature (°C)
300 LFM (1.5 m/s)
100 LFM (0.5 m/s)
25
40
55
70
85
Ambient Air Temperature (°C)
Figure 3: Maximum load current vs. baseplate temperature when conductively
cooled. Note: The system design must provide a suitable thermal path that
maintains the baseplate temperature below 100 °C.
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from pin 3 to pin 1 (nominal input voltage).
Figure 5: Output voltage response in the SM version to step-change in load
current (50%-75%-50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 100 µF
electrolytic cap and 1 µF ceramic cap. Ch 1: Vout (100 mV/div), Ch 2: Iout (10
A/div).
Figure 6: Output voltage response in the SM version to step-change in input
voltage (250 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1:
Vout (100 mV/div), Ch 2: Vin (20 V/div).
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 9
Input:9-36 V
Output:2.5 V
Current:10 A
Part No.:IQ18025SKx10
Technical Specification
IQ18025SKx10 Electrical Characteristics (2.5 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 18 Vdc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max.
Units Notes & Conditions
5.0
A
220
280
mA
10
14
mA
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current (enabled)
Disabled Input Current
Response to Input Transient
0.06
V
Input Terminal Ripple Current
280
mA
Recommended Input Fuse
20
A
2.500
2.525
V
±0.1
±0.3
%
±0.1
Vin min; trim up; in current limit
250 V/ms; see Figure 6
RMS
Fast acting fuse recommended; see Note 4
OUTPUT CHARACTERISTICS
Output Voltage Set Point
2.475
Output Voltage Regulation
Over Line
Over Load
Over Temperature
Total Output Voltage Range
±0.3
%
-38
38
mV
2.437
2.563
V
35
70
mV
Full load
8
20
mV
Full load
10
A
13.5
A
Output Voltage Ripple and Noise
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Peak-to-Peak
RMS
Operating Output Current Range
0
Output DC Current Limit Inception
11.0
12.5
Subject to thermal derating
Back-Drive Current Limit while Enabled
2.8
A
Negative current drawn into output pins
Back-Drive Current Limit while Disabled
2
mA
Negative current drawn into output pins
µF
Vout nominal at full load (resistive load); See Note 2
mV
50 % to 75 % to 50 % Iout max; see Figure 5
Maximum Output Capacitance
10,000
Output Voltage during Load Current Transient
Step Change in Output Current (0. 1A/µs)
100
Settling Time
100
Output Voltage Trim Range
-10
Output Voltage Remote Sense Range
Output Over-Voltage Protection
2.8
3.1
µs
To within 1 % Vout nom; see Figure 5
10
%
Across Pins 8 & 4; Common Figures 3-4; see Note 3
10
%
Across Pins 8 & 4
3.3
V
Over full temp range
%
See Figure 1 for efficiency curve
EFFICIENCY
100 % Load
77
50 % Load
71
%
See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and
noise, consult SynQor applications support (e-mail: [email protected])
Note 2: Recommended minimum output capacitance is 100 uF
Note 3: Trim-up range is limited below 10 % at low line and full load. Contact SynQor applications support for more detail (email: [email protected])
Note 4: Safety certification requires the use of a fuse rated at or below this value.
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 10
Input:9-36 V
Output:2.5 V
Current:10 A
Part No.:IQ18025SKx10
Technical Specification
90
14
85
12
Power Dissipation (W)
Efficiency (%)
80
75
70
65
60
8
6
4
9 Vin
9 Vin
55
10
2
18 Vin
18 Vin
36 Vin
36 Vin
50
0
2
4
6
8
0
10
0
2
4
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25 °C.
8
10
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25 °C.
12
12
10
10
8
8
Iout (A)
Iout (A)
6
Load Current (A)
Load Current (A)
6
4
6
4
400 LFM (2.0 m/s)
2
300 LFM (1.5 m/s)
2
200 LFM (1.0 m/s)
0
100 LFM (0.5 m/s)
50
60
70
80
90
100
110
0
Baseplate Temperature (°C)
25
40
55
70
85
Ambient Air Temperature (°C)
Figure 3: Maximum load current vs. baseplate temperature when conductively
cooled. Note: The system design must provide a suitable thermal path that
maintains the baseplate temperature below 100 °C.
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from pin 3 to pin 1 (nominal input voltage).
Figure 5: Output voltage response in the SM version to step-change in load
current (50 % -75 % -50 % of Iout(max); dI/dt = 0.1 A/µs). Load cap: 100 µF
electrolytic cap and 1 µF ceramic cap. Ch 1: Vout (100 mV/div), Ch 2: Iout (10
A/div).
Figure 6: Output voltage response in the SM version to step-change in input
voltage (250 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1:
Vout (100 mV/div), Ch 2: Vin (20 V/div).
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 11
Input:9-36 V
Output:3.3 V
Current:8 A
Part No.:IQ18033SKx08
Technical Specification
IQ18033SKx08 Electrical Characteristics (3.3 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 18 Vdc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max.
Units Notes & Conditions
5.0
A
200
250
mA
10
14
mA
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current (enabled)
Disabled Input Current
Response to Input Transient
0.05
V
Input Terminal Ripple Current
240
mA
Recommended Input Fuse
20
A
3.300
3.333
V
±0.1
±0.3
%
±0.1
Vin min; trim up; in current limit
250 V/ms; see Figure 6
RMS
Fast acting fuse recommended; see Note 4
OUTPUT CHARACTERISTICS
Output Voltage Set Point
3.267
Output Voltage Regulation
Over Line
Over Load
Over Temperature
Total Output Voltage Range
±0.3
%
-50
50
mV
3.217
3.383
V
25
50
mV
Full load
5
10
mV
Full load
8
A
11.5
A
Output Voltage Ripple and Noise
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Peak-to-Peak
RMS
Operating Output Current Range
0
Output DC Current Limit Inception
8.5
10.0
Subject to thermal derating
Back-Drive Current Limit while Enabled
3.3
A
Negative current drawn into output pins
Back-Drive Current Limit while Disabled
2
mA
Negative current drawn into output pins
µF
Vout nominal at full load (resistive load); See Note 2
mV
50 % to 75 % to 50 % Iout max; see Figure 5
Maximum Output Capacitance
10,000
Output Voltage during Load Current Transient
Step Change in Output Current (0. 1A/µs)
175
Settling Time
80
Output Voltage Trim Range
-10
Output Voltage Remote Sense Range
Output Over-Voltage Protection
3.9
4.1
µs
To within 1 % Vout nom; see Figure 5
10
%
Across Pins 8 & 4; Common Figures 3-4; see Note 3
10
%
Across Pins 8 & 4
4.5
V
Over full temp range
%
See Figure 1 for efficiency curve
EFFICIENCY
100 % Load
79
50 % Load
73
%
See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and
noise, consult SynQor applications support (e-mail: [email protected])
Note 2: Recommended minimum output capacitance is 100uF
Note 3: Trim-up range is limited below 10 % at low line and full load. Contact SynQor applications support for more detail (email: [email protected])
Note 4: Safety certification requires the use of a fuse rated at or below this value.
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 12
Input:9-36 V
Output:3.3 V
Current:8 A
Part No.:IQ18033SKx08
Technical Specification
12
90
85
10
Power Dissipation (W)
Efficiency (%)
80
75
70
65
60
9 Vin
55
8
6
4
9 Vin
2
18 Vin
18 Vin
36 Vin
36 Vin
50
0
2
4
6
0
8
0
2
4
6
8
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25 °C.
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25 °C.
21
9
8
18
7
15
5
Iout (A)
Iout (A)
6
4
3
12
9
6
2
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
1
3
0
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
50
60
70
80
90
100
110
0
Baseplate Temperature (°C)
25
40
55
70
85
Ambient Air Temperature (°C)
Figure 3: Maximum load current vs. baseplate temperature when conductively
cooled. Note: The system design must provide a suitable thermal path that
maintains the baseplate temperature below 100 °C.
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from pin 3 to pin 1 (nominal input voltage).
Figure 5: Output voltage response in the SM version to step-change in load
current (50 % -75 % -50 % of Iout(max); dI/dt = 0.1 A/µs). Load cap: 100 µF
electrolytic cap and 1 µF ceramic cap. Ch 1: Vout (200 mV/div), Ch 2: Iout (5 A/
div).
Figure 6: Output voltage response in the SM version to step-change in input
voltage (250 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1:
Vout (100 mV/div), Ch 2: Vin (20 V/div).
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 13
Input:9-36 V
Output:5 V
Current:5 A
Part No.:IQ18050SKx05
Technical Specification
IQ18050SKx05 Electrical Characteristics (5.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 18 Vdc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max.
Units Notes & Conditions
5.0
A
175
220
mA
10
14
mA
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current (enabled)
Disabled Input Current
Response to Input Transient
0.07
V
Input Terminal Ripple Current
250
mA
Recommended Input Fuse
20
A
5.000
5.050
V
±0.1
±0.3
%
±0.1
Vin min; trim up; in current limit
250 V/ms; see Figure 6
RMS
Fast acting fuse recommended; see Note 4
OUTPUT CHARACTERISTICS
Output Voltage Set Point
4.950
Output Voltage Regulation
Over Line
Over Load
Over Temperature
Total Output Voltage Range
±0.3
%
-75
75
mV
4.875
5.125
V
25
50
mV
Full load
5
10
mV
Full load
5
A
7.0
A
Output Voltage Ripple and Noise
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Peak-to-Peak
RMS
Operating Output Current Range
0
Output DC Current Limit Inception
5.4
6.2
Subject to thermal derating
Back-Drive Current Limit while Enabled
3.0
A
Negative current drawn into output pins
Back-Drive Current Limit while Disabled
2
mA
Negative current drawn into output pins
µF
Vout nominal at full load (resistive load); See Note 2
mV
50 % to 75 % to 50 % Iout max; see Figure 5
Maximum Output Capacitance
5,000
Output Voltage during Load Current Transient
Step Change in Output Current (0. 1A/µs)
275
Settling Time
100
Output Voltage Trim Range
-10
Output Voltage Remote Sense Range
Output Over-Voltage Protection
5.8
6.2
µs
To within 1 % Vout nom; see Figure 5
10
%
Across Pins 8 & 4; Common Figures 3-4; see Note 3
10
%
Across Pins 8 & 4
6.6
V
Over full temp range
%
See Figure 1 for efficiency curve
EFFICIENCY
100 % Load
81
50 % Load
77
%
See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and
noise, consult SynQor applications support (e-mail: [email protected])
Note 2: Recommended minimum output capacitance is 100uF
Note 3: Trim-up range is limited below 10 % at low line and full load. Contact SynQor applications support for more detail (email: [email protected])
Note 4: Safety certification requires the use of a fuse rated at or below this value.
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 14
Input:9-36 V
Output:5 V
Current:5 A
Part No.:IQ18050SKx05
Technical Specification
10
90
9
85
8
Power Dissipation (W)
Efficiency (%)
80
75
70
65
60
9 Vin
50
1
2
3
4
5
4
3
9 Vin
18 Vin
1
36 Vin
0
6
2
18 Vin
55
7
0
5
36 Vin
0
1
2
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25 °C.
4
5
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25 °C.
6
6
5
5
4
4
Iout (A)
Iout (A)
3
Load Current (A)
Load Current (A)
3
2
3
2
400 LFM (2.0 m/s)
1
300 LFM (1.5 m/s)
1
200 LFM (1.0 m/s)
0
100 LFM (0.5 m/s)
50
60
70
80
90
100
110
0
Baseplate Temperature (°C)
25
40
55
70
85
Ambient Air Temperature (°C)
Figure 3: Maximum load current vs. baseplate temperature when conductively
cooled. Note: The system design must provide a suitable thermal path that
maintains the baseplate temperature below 100 °C.
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from pin 3 to pin 1 (nominal input voltage).
Figure 5: Output voltage response in the SM version to step-change in load
current (50 % -75 % -50 % of Iout(max); dI/dt = 0.1 A/µs). Load cap: 100 µF
electrolytic cap and 1 µF ceramic cap. Ch 1: Vout (500 mV/div), Ch 2: Iout (5 A/
div).
Figure 6: Output voltage response in the SM version to step-change in input
voltage (250 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1:
Vout (100 mV/div), Ch 2: Vin (20 V/div).
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 15
Input:9-36 V
Output:7 V
Current:3.5 A
Part No.:IQ18070SKx04
Technical Specification
IQ18070SKx04 Electrical Characteristics (7.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 18 Vdc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max.
Units Notes & Conditions
5.0
A
180
230
mA
10
14
mA
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current (enabled)
Disabled Input Current
Response to Input Transient
0.05
V
Input Terminal Ripple Current
250
mA
Recommended Input Fuse
20
A
7.000
7.070
V
±0.1
±0.3
%
±0.1
Vin min; trim up; in current limit
250 V/ms; see Figure 6
RMS
Fast acting fuse recommended; see Note 4
OUTPUT CHARACTERISTICS
Output Voltage Set Point
6.930
Output Voltage Regulation
Over Line
Over Load
Over Temperature
Total Output Voltage Range
±0.3
%
-105
105
mV
6.825
7.175
V
50
mV
Full load
Full load
Output Voltage Ripple and Noise
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Peak-to-Peak
25
RMS
5
Operating Output Current Range
0
Output DC Current Limit Inception
4.2
5.0
10
mV
3.5
A
5.8
A
Subject to thermal derating
Back-Drive Current Limit while Enabled
2.5
A
Negative current drawn into output pins
Back-Drive Current Limit while Disabled
2
mA
Negative current drawn into output pins
µF
Vout nominal at full load (resistive load); See Note 2
mV
50 % to 75 % to 50 % Iout max; see Figure 5
Maximum Output Capacitance
4,000
Output Voltage during Load Current Transient
Step Change in Output Current (0. 1A/µs)
250
Settling Time
100
Output Voltage Trim Range
-10
Output Voltage Remote Sense Range
Output Over-Voltage Protection
8.2
8.5
µs
To within 1 % Vout nom; see Figure 5
10
%
Across Pins 8 & 4; Common Figures 3-4; see Note 3
10
%
Across Pins 8 & 4
8.7
V
Over full temp range
%
See Figure 1 for efficiency curve
EFFICIENCY
100 % Load
81
50 % Load
75
%
See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications
support (e-mail: [email protected])
Note 2: Recommended minimum output capacitance is 100uF
Note 3: Trim-up range is limited below 10 % at low line and full load. Contact SynQor applications support for more detail (email: [email protected])
Note 4: Safety certification requires the use of a fuse rated at or below this value.
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 16
Input:9-36 V
Output:7 V
Current:3.5 A
Part No.:IQ18070SKx04
Technical Specification
10
90
9
85
8
Power Dissipation (W)
Efficiency (%)
80
75
70
65
60
18 Vin
0.0
0.5
1.0
1.5
2.0
2.5
5
4
3
3.0
9 Vin
18 Vin
1
36 Vin
50
6
2
9 Vin
55
7
0
3.5
36 Vin
0.0
0.5
1.0
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25 °C.
2.0
2.5
3.0
3.5
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25 °C.
4
4.0
3.5
3.5
3
3.0
2.5
2.5
Iout (A)
Iout (A)
1.5
Load Current (A)
Load Current (A)
2
2.0
1.5
1.5
1
0.5
0
50
60
70
80
90
100
110
1.0
400 LFM (2.0 m/s)
0.5
200 LFM (1.0 m/s)
0.0
Baseplate Temperature (°C)
300 LFM (1.5 m/s)
100 LFM (0.5 m/s)
25
40
55
70
85
Ambient Air Temperature (°C)
Figure 3: Maximum load current vs. baseplate temperature when conductively
cooled. Note: The system design must provide a suitable thermal path that
maintains the baseplate temperature below 100 °C.
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from pin 3 to pin 1 (nominal input voltage).
Figure 5: Output voltage response in the SM version to step-change in load
current (50 % -75 % -50 % of Iout(max); dI/dt = 0.1 A/µs). Load cap: 100 µF
electrolytic cap and 1 µF ceramic cap. Ch 1: Vout (500 mV/div), Ch 2: Iout (2 A/
div).
Figure 6: Output voltage response in the SM version to step-change in input
voltage (250 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1:
Vout (100 mV/div), Ch 2: Vin (20 V/div).
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 17
Input:9-36 V
Output:12 V
Current:2 A
Part No.:IQ18120SKx02
Technical Specification
IQ18120SKx02 Electrical Characteristics (12.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 18 Vdc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max.
Units Notes & Conditions
5.0
A
250
310
mA
10
14
mA
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current (enabled)
Disabled Input Current
Response to Input Transient
0.15
V
Input Terminal Ripple Current
250
mA
Recommended Input Fuse
20
A
12.00
12.12
V
±0.1
±0.3
%
±0.1
Vin min; trim up; in current limit
250 V/ms; see Figure 6
RMS
Fast acting fuse recommended; see Note 4
OUTPUT CHARACTERISTICS
Output Voltage Set Point
11.88
Output Voltage Regulation
Over Line
Over Load
Over Temperature
Total Output Voltage Range
±0.3
%
-180
180
mV
11.70
12.30
V
40
80
mV
Full load
8
20
mV
Full load
2
A
3.4
A
Output Voltage Ripple and Noise
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Peak-to-Peak
RMS
Operating Output Current Range
0
Output DC Current Limit Inception
2.6
3.0
Subject to thermal derating
Back-Drive Current Limit while Enabled
2.5
A
Negative current drawn into output pins
Back-Drive Current Limit while Disabled
2
mA
Negative current drawn into output pins
µF
Vout nominal at full load (resistive load); See Note 2
mV
50 % to 75 % to 50 % Iout max; see Figure 5
Maximum Output Capacitance
1,500
Output Voltage during Load Current Transient
Step Change in Output Current (0. 1A/µs)
250
Settling Time
150
Output Voltage Trim Range
-10
Output Voltage Remote Sense Range
Output Over-Voltage Protection
15.0
15.5
µs
To within 1 % Vout nom; see Figure 5
10
%
Across Pins 8 & 4; Common Figures 3-4; see Note 3
10
%
Across Pins 8 & 4
16.0
V
Over full temp range
%
See Figure 1 for efficiency curve
EFFICIENCY
100 % Load
78
50 % Load
71
%
See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications
support (e-mail: [email protected])
Note 2: Recommended minimum output capacitance is 100 uF
Note 3: Trim-up range is limited below 10 % at low line and full load. Contact SynQor applications support for more detail (email: [email protected])
Note 4: Safety certification requires the use of a fuse rated at or below this value.
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 18
Input:9-36 V
Output:12 V
Current:2 A
Part No.:IQ18120SKx02
90
16
85
14
80
12
Power Dissipation (W)
Efficiency (%)
Technical Specification
75
70
65
60
9 Vin
55
10
8
6
4
9 Vin
2
18 Vin
18 Vin
36 Vin
36 Vin
50
0.0
0.5
1.0
1.5
0
2.0
0.0
0.5
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25 °C.
1.5
2.0
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25 °C.
2.5
2.5
2
2.0
1.5
1.5
Iout (A)
Iout (A)
1.0
Load Current (A)
Load Current (A)
1
1.0
0.5
400 LFM (2.0 m/s)
0.5
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
0
100 LFM (0.5 m/s)
50
60
70
80
90
100
110
0.0
Baseplate Temperature (°C)
25
40
55
70
85
Ambient Air Temperature (°C)
Figure 3: Maximum load current vs. baseplate temperature when conductively
cooled. Note: The system design must provide a suitable thermal path that
maintains the baseplate temperature below 100 °C.
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from pin 3 to pin 1 (nominal input voltage).
Figure 5: Output voltage response in the SM version to step-change in load
current (50 % -75 % -50 % of Iout(max); dI/dt = 0.1 A/µs). Load cap: 100 µF
electrolytic cap and 1 µF ceramic cap. Ch 1: Vout (500 mV/div), Ch 2: Iout (1 A/
div).
Figure 6: Output voltage response in the SM version to step-change in input
voltage (250 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1:
Vout (200 mV/div), Ch 2: Vin (20 V/div).
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 19
Input:9-36 V
Output:15 V
Current:1.7 A
Part No.:IQ18150SKx02
Technical Specification
IQ18150SKx02 Electrical Characteristics (15.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 18 Vdc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current (enabled)
Disabled Input Current
Response to Input Transient
Input Terminal Ripple Current
Recommended Input Fuse
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Line
Over Load
Over Temperature
Total Output Voltage Range
Output Voltage Ripple and Noise
Peak-to-Peak
RMS
Operating Output Current Range
Output DC Current Limit Inception
Back-Drive Current Limit while Enabled
Back-Drive Current Limit while Disabled
Typ.
Max.
Units
5.0
440
14
20
A
mA
mA
V
mA
A
15.00
15.15
V
±0.1
±0.1
±0.3
±0.3
225
15.38
%
%
mV
V
150
30
1.7
4.6
mV
mV
A
A
A
mA
350
10
0.08
250
14.85
-225
14.62
75
15
0
2.4
3.5
3.0
2
Maximum Output Capacitance
1,500
Output Voltage during Load Current Transient
Step Change in Output Current (0. 1A/µs)
Settling Time
Output Voltage Trim Range
µF
175
250
-10
mV
µs
10
%
Output Voltage Remote Sense Range
10
Output Over-Voltage Protection
17.5
19.0
20.0
EFFICIENCY
100 % Load
77
50 % Load
70
Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced
applications support (e-mail: [email protected])
%
V
Notes & Conditions
Vin min; trim up; in current limit
250 V/ms; see Figure 6
RMS
Fast acting fuse recommended; see Note 4
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Full load
Full load
Subject to thermal derating
Negative current drawn into output pins
Negative current drawn into output pins
Vout nominal at full load (resistive load); See
Note 2
50 % to 75 % to 50 % Iout max; see Figure 5
To within 1 % Vout nom; see Figure 5
Across Pins 8 & 4; Common Figures 3-5; see
Note 3
Across Pins 8 & 4
Over full temp range
%
See Figure 1 for efficiency curve
%
See Figure 1 for efficiency curve
output voltage ripple and noise, consult SynQor
Note 2: Recommended minimum output capacitance is 100uF
Note 3: Trim-up range is limited below 10 % at low line and full load. Contact SynQor applications support for more detail (email: [email protected])
Note 4: Safety certification requires the use of a fuse rated at or below this value.
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 20
Input:9-36 V
Output:15 V
Current:1.7 A
Part No.:IQ18150SKx02
90
16
85
14
80
12
Power Dissipation (W)
Efficiency (%)
Technical Specification
75
70
65
60
10
8
6
4
9 Vin
9 Vin
55
2
18 Vin
18 Vin
36 Vin
50
0.0
0.3
0.6
0.9
1.2
1.5
36 Vin
0
1.8
0.0
0.3
0.6
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25 °C.
1.2
1.5
1.8
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25 °C.
1.8
1.8
1.6
1.6
1.4
1.4
1.2
1.2
1
1.0
Iout (A)
Iout (A)
0.9
Load Current (A)
Load Current (A)
0.8
0.8
0.6
0.6
0.4
400 LFM (2.0 m/s)
0.4
0.2
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
0.2
0
50
60
70
80
90
100
110
0.0
Baseplate Temperature (°C)
100 LFM (0.5 m/s)
25
40
55
70
85
Ambient Air Temperature (°C)
Figure 3: Maximum load current vs. baseplate temperature when conductively
cooled. Note: The system design must provide a suitable thermal path that
maintains the baseplate temperature below 100 °C.
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from pin 3 to pin 1 (nominal input voltage).
Figure 5: Output voltage response in the SM version to step-change in load
current (50 % -75 % -50 % of Iout(max); dI/dt = 0.1 A/µs). Load cap: 100 µF
electrolytic cap and 1 µF ceramic cap. Ch 1: Vout (500 mV/div), Ch 2: Iout (1 A/
div).
Figure 6: Output voltage response in the SM version to step-change in input
voltage (250 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1:
Vout (200 mV/div), Ch 2: Vin (20 V/div).
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 21
Technical
Specification
IQ18xxxSKXxxx
Application Section
BASIC OPERATION AND FEATURES
This converter series uses a two-stage power
topology. The first stage is a buck-converter that
output voltage constant over variations in line,
temperature. The second stage uses a transformer
the functions of input/output isolation and voltage
step-down to achieve the output voltage required.
conversion
keeps the
load, and
to provide
step-up or
5V
50k
ON/OFF
Both the first stage and the second stage switch at a fixed
frequency for predictable EMI performance. Rectification of the
transformer’s output is accomplished with synchronous rectifiers.
These devices, which are MOSFETs with a very low on-state
resistance, dissipate far less energy than Schottky diodes. This
is the primary reason that the converter has such high efficiency.
These converters are offered totally encased to withstand harsh
environments and thermally demanding applications. Dissipation
throughout the converter is so low that it does not require a
heatsink for operation in many applications; however, adding
a heatsink provides improved thermal derating performance in
demanding applications.
This series of converters use the industry standard footprint and
pin-out configuration.
TTL
100pF
Vin(-)
Figure B: Internal ON/OFF pin circuitry
REMOTE SENSE(+) (Pins 7 and 5): The SENSE(+) inputs
correct for voltage drops along the conductors that connect the
converter’s output pins to the load.
Pin 7 should be connected to Vout(+) and Pin 5 should be
connected to Vout(-) at the point on the load where regulation is
desired. A remote connection at the load can adjust for a voltage
drop only as large as that specified in this datasheet, that is
[Vout(+) - Vout(-)] – [Vsense(+) - Vsense(-)] <
CONTROL FEATURES
Sense Range % x Vout
REMOTE ON/OFF (Pin 2): The ON/OFF input, Pin 2, permits
the user to control when the converter is on or off. This input
is referenced to the return terminal of the input bus, Vin(-).
The ON/OFF signal is active low (meaning that a low turns the
converter on). Figure A details four possible circuits for driving
the ON/OFF pin. Figure B is a detailed look of the internal ON/
OFF circuitry.
ON/OFF
ON/OFF
Sense Range % = Trim-up Range % (usually 10 %)
Pins 7 and 5 must be connected for proper regulation of
the output voltage. If these connections are not made, the
converter will deliver an output voltage that is slightly higher
than its specified value.
Note: the output over-voltage protection circuit senses the
voltage across the output (pins 8 and 4) to determine when
it should trigger, not the voltage across the converter’s sense
leads (pins 7 and 5). Therefore, the resistive drop on the board
should be small enough so that output OVP does not trigger,
even during load transients.
Vin(_)
Vin(_)
Remote Enable Circuit
50k
Negative Logic
(Permanently Enabled)
5V
ON/OFF
TTL/
CMOS
ON/OFF
Vin(_)
Vin(_ )
Open Collector Enable Circuit
Direct Logic Drive
Figure A: Various circuits for driving the ON/OFF pin.
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 22
Technical
Specification
IQ18xxxSKXxxx
Application Section
OUTPUT VOLTAGE TRIM (Pin 6): The TRIM input permits the
user to adjust the output voltage across the sense leads up or
down according to the trim range specifications.
To decrease the output voltage, the user should connect a
resistor between Pin 6 and Pin 5 (SENSE(-) input). For a desired
decrease of the nominal output voltage, the value of the resistor
should be
Rtrim-down =
- 10.22
(511
D% )
[kW]
where
D% =
Vnominal – Vdesired
Vnominal
x 100[%]
To increase the output voltage, the user should connect a
resistor between Pin 6 and Pin 7 (SENSE(+) input). For a desired
increase of the nominal output voltage, the value of the resistor
should be
Rtrim-up =
where
(
5.11VOUT x (100+D%)
1.225D%
_ 511 _ 10.22
D%
)
[kW]
Vout = Nominal Output Voltage
Trim graphs show the relationship between the trim resistor
value Rtrim-up and Rtrim-down, showing the total range the
output voltage can be trimmed up or down.
Note: the TRIM feature does not affect the voltage at which the
output over-voltage protection circuit is triggered. Trimming the
output voltage too high may cause the over-voltage protection
circuit to engage, particularly during transients.
It is not necessary for the user to add capacitance at the
Trim pin. The node is internally bypassed to eliminate noise.
* For 1.2Vout unit replace 1.225 with 0.6 (see Trim Up
Graph Common Figure 3).
PROTECTION FEATURES
Input Under-Voltage Lockout: The converter is designed
to turn off when the input voltage is too low, helping avoid an
input system instability problem, described in more detail in
the application note titled “Input System Instability” on our
website. The lockout circuitry is a comparator with dc hysteresis.
When the input voltage is rising, it must exceed the typical TurnOn Voltage Threshold value (listed on the specifications page)
before the converter will turn on. Once the converter is on,
the input voltage must fall below the typical Turn-Off Voltage
Threshold value before the converter will turn off.
Output Current Limit: The maximum current limit remains
constant as the output voltage drops. However, once the output
voltage drops below the specified Output DC Current-Limit
Shutdown Voltage, the converter turns off.
The converter then enters a “hiccup mode” where it repeatedly
turns on and off at a 5 Hz (nominal) frequency with a 5 % duty
cycle until the overload is removed. This prevents excessive
heating of the converter or the system board.
Output Over-Voltage Limit: If the voltage across the output
pins exceeds the Output Over-Voltage Protection threshold, the
converter will immediately stop switching. This prevents damage
to the load circuit due to 1) excessive series resistance in output
current path from converter output pins to sense point, 2) a
release of a overload condition, or 3) a release of a current limit
condition. Load capacitance determines exactly how high the
output voltage will rise in response to these conditions. After 200
ms the converter will automatically restart.
Over-Temperature Shutdown: A temperature sensor on
the internal converter PCB senses the average temperature of
the module. The thermal shutdown circuit is designed to turn
the converter off when the temperature at the sensed location
reaches the Over-Temperature Shutdown value. It will allow the
converter to turn on again when the temperature of the sensed
location falls by the amount of the Over-Temperature Shutdown
Restart Hysteresis value.
Total DC Variation of VOUT: For the converter to meet its
full specifications, the maximum variation of the dc value of
VOUT, due to both trimming and remote load voltage drops,
should not be greater than that specified for the output
voltage trim range.
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 23
Technical
Specification
IQ18xxxSKXxxx
Application Section
APPLICATION CONSIDERATIONS
Input System Instability: This condition can occur because
any dc-dc converter appears incrementally as a negative
resistance load. A detailed application note titled “Input System
Instability” is available on the SynQor website which provides
an understanding of why this instability arises, and shows the
preferred solution for correcting it. The Electrical Characteristics
Table indicates a “Recommended External Input Capacitance”.
The value needed for that capacitance and ESR can vary based
on application parameters. Input stability can be evaluated
using our “Stability Calculator” tool in the Technical Support
section of our website www.synqor.com.
Application Circuits: Figure C provides a typical circuit diagram
which details the input filtering and voltage trimming.
Vin(+)
External
Input
Filter
Vin
Electrolytic
Capacitor
Vout(+)
Vsense(+)
ON/OFF
Trim
Vsense(_)
Vin(_)
Rtrim-up
or
Rtrim-down
Cload
Iload
Vout(_)
Figure C: Typical application circuit (negative logic unit, permanently enabled).
Input Filtering and External Capacitance: Figure D provides
a diagram showing the internal input filter components. This filter
dramatically reduces input terminal ripple current, which otherwise
could exceed the rating of an external electrolytic input capacitor.
The recommended external input capacitance is specified in the
Input Characteristics section on the Electrical Characteristics
page. The input capacitance need not exactly match the specified
value. More detailed information is available in the application note
titled “EMI Characteristics” on the SynQor website.
L
Vin(+)
C
Vin(_)
Figure D: Internal Input Filter Diagram (component values listed on the input characteristics page).
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 24
Technical
Specification
IQ18xxxSKXxxx
Application Section
Startup Inhibit Period: The Startup Inhibit Period ensures that
the converter will remain off for approximately 200 ms when it is
shut down for any reason. When an output short is present, this
generates a 5 Hz “hiccup mode,” which prevents the converter
from overheating. In all, there are seven ways that the converter
can be shut down, initiating a Startup Inhibit Period:
• InputUnder-VoltageLockout
When the ON/OFF pin goes low after t2, and the Startup Inhibit
Period has elapsed, and the output turns on within the typical
Turn-On Time.
Thermal Considerations: The maximum operating baseplate
temperature, TB, is 100 ºC. As long as the user’s thermal system
keeps TB < 100 ºC, the converter can deliver its full rated power.
A power derating curve can be calculated for any heatsink that is
attached to the baseplate of the converter. It is only necessary to
determine the thermal resistance, RTHBA, of the chosen heatsink
between the baseplate and the ambient air for a given airflow
rate. This information is available from the heatsink vendor. The
following formula can then be used to determine the maximum
power the converter can dissipate for a given thermal condition if
its baseplate is to be no higher than 100 ºC.
• InputOver-VoltageShutdown
• OutputOver-VoltageProtection
• OverTemperatureShutdown
• CurrentLimit(whenVoutisbelowshutdownvoltage)
• ShortCircuitProtection
• TurnedoffbytheON/OFFinput
Figure E shows three turn-on scenarios, where a Startup Inhibit
Period is initiated at t0, t1, and t2:
Before time t0, when the input voltage is below the UVL threshold,
the unit is disabled by the Input Under-Voltage Lockout (UVL)
feature. When the input voltage rises above the UVL threshold,
the Input Under-Voltage Lockout is released, and a Startup Inhibit
Period is initiated. At the end of this delay, the ON/OFF pin is
evaluated, and since it is active, the unit turns on.
At time t1, the unit is disabled by the ON/OFF pin, and it cannot
be enabled again until the Startup Inhibit Period has elapsed.
max
Pdiss =
100 ºC - TA
RTHBA
This value of power dissipation can then be used in conjunction
with the data shown in Figure 2 to determine the maximum load
current (and power) that the converter can deliver in the given
thermal condition.
We recommend that a suitable thermal interface material such as
a thermally conductive pad or grease be used to assure a good
thermal interface between the base plate and the conductive
cooling device.
Vin
Under-Voltage
Lockout TurnOn Threshold
ON/OFF
(neg logic)
ON
OFF ON
OFF
ON
35ms
Vout
(typical turn on time)
200ms
2ms
(initial start-up
inhibit period)
(typical start-up
inhibit period)
t1
t0
200ms
t2
t
Figure E: Startup Inhibit Period (turn-on time not to scale)
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 25
Technical
Specification
IQ18xxxSKXxxx
Standards & Qualification Testing
Parameter
Notes & Conditions
STANDARDS COMPLIANCE
UL 60950-1:2007/A2:2014
Basic Insulation
CAN/CSA C22.2 No. 60950-1:2007/A2:2014
EN 60950-1:2006/A2:2013
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new
releases or download from the SynQor website.
Parameter
# Units Test Conditions
QUALIFICATION TESTING
Life Test
32
95 % rated Vin and load, units at derating point, 1000 hours
Vibration
5
10-55 Hz sweep, 0.060 " total excursion, 1 min./sweep, 120 sweeps for 3 axis
Mechanical Shock
5
100 g minimum, 2 drops in x, y, and z axis
Temperature Cycling
10
-40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles
Power/Thermal Cycling
5
Toperating = min to max, Vin = min to max, full load, 100 cycles
Design Marginality
5
Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105 % load
Humidity
5
85 °C, 95 % RH, 1000 hours, continuous Vin applied except 5 min/day
Solderability
15 pins
Altitude
2
MIL-STD-883, method 2003
70,000 feet (21 km), see Note
Note: A conductive cooling design is generally needed for high altitude applications because of naturally poor convective cooling at rare atmospheres.
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 26
Technical
Specification
IQ18xxxSKXxxx
Standard Mechanical Diagram
1.036±.020 (26.31±0.5)
.600 (15.24)
.450 (11.43)
0.500±.025
(12.7±0.63)
Overall height
.300 (7.62)
.150 (3.81)
8 7 6 5 4
0.18
(4.6)
0.004 [0.10]
Top View
1.436±.020
(36.47±0.5)
Side View
1.10
(27.9)
1
2
3
.218±.020 (5.54±0.5)
NOTES
.143±.020
(3.63±0.5)
.300 (7.62)
PIN DESIGNATIONS
.600 (15.24)
1)Baseplate flatness tolerance is 0.004” (.10mm) TIR for surface.
2)Pins 1-3, 5-7 are 0.040” (1.02mm) diameter, with 0.080” (2.03mm)
diameter standoff shoulders.
3)Pins 4 and 8 are 0.062” (1.57 mm) diameter with 0.100” (2.54 mm)
diameter standoff shoulders.
4)All Pins: Material – Copper Alloy; Finish – Matte Tin over Nickel plate
5)Undimensioned components are shown for visual reference only.
6)Weight: 1.1oz (31g) Typical
7)All dimensions in inches (mm)
Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm)
x.xxx +/-0.010 in. (x.xx +/-0.25mm)
8)Workmanship: Meets or exceeds IPC-A-610 Class II
9)Recommended pin length is 0.03” (0.76mm)
greater than the PCB thickness.
Pin
Label
1
Vin(+)
2
ON/OFF
Function
Positive input voltage
TTL input to turn converter on and off,
referenced to Vin(–), with internal pull up.
Negative input voltage
Negative output voltage
Negative remote sense(see note 1)
Output voltage trim (see note 2)
Positive remote sense (see note 3)
Positive output voltage
3
Vin(-)
4
Vout(-)
5 SENSE(-)
6
TRIM
7 SENSE(+)
8
Vout(+)
Notes:
1) SENSE(–) should be connected to Vout(–) either remotely or
at the converter.
2) Leave TRIM pin open for nominal output voltage.
3) SENSE(+) should be connected to Vout(+) either remotely or
at the converter.
Product # IQ18xxxSKXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 27
Technical
Specification
IQ18xxxSKXxxx
Flanged Mechanical Diagram
USE W/ 4-40 OR
M3 SCREW (4X)
RECOM. TORQUE
3 in. LB.
Ø.13 [3.3]R
OVERALL HEIGHT
.500±.025
[12.7±0.63]
1.50 [38.1]
1.30 [33]
1.036±.020
[26.31±0.5]
.600 [15.24]
.450 [11.43]
.300 [7.62]
.18 [4.6]
SEE NOTE 5
.010 [0.25]
.150 [3.81]
4 5 6 7 8
1.12
[28.3]
.94
[23.9]
1.436
[36.47]
1.100
[27.94]
.21
[5.3]
.14 [3.6]
.017±.020
[0.43±0.5]
3
.218±.020 [5.54±0.5]
1
.13 [3.2]
.300 [7.62]
.350±.020 [8.89±0.5]
.600 [15.24]
.450±.020 [11.43±0.5]
NOTES
1)Applied torque per screw should not exceed 6in-lb
2)Baseplate flatness tolerance is 0.01” (.25mm) TIR for surface.
3)Pins 1-3, 5-7 are 0.040” (1.02mm) diameter, with 0.080” (2.03mm)
diameter standoff shoulders.
4)Pins 4 and 8 are 0.062” (1.57 mm) diameter with 0.100” (2.54 mm)
diameter standoff shoulders.
5)All Pins: Material – Copper Alloy
Finish - Matte Tin over Nickel plate
6)Weight: 1.22 oz (34.6g) Typical
7)Undimensioned components are shown for visual reference only.
8)All dimensions in inches (mm)
Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm)
x.xxx +/-0.010 in. (x.xx +/-0.25mm)
9)Workmanship: Meets or exceeds IPC-A610 Class II
Product # IQ18xxxSKXxxx
2
Phone 1-888-567-9596
www.synqor.com
PIN DESIGNATIONS
Pin
Label
1
Vin(+)
2
ON/OFF
Function
Positive input voltage
TTL input to turn converter on and off,
referenced to Vin(–), with internal pull up.
Negative input voltage
Negative output voltage
Negative remote sense(see note 1)
Output voltage trim (see note 2)
Positive remote sense (see note 3)
Positive output voltage
3
Vin(-)
4
Vout(-)
5 SENSE(-)
6
TRIM
7 SENSE(+)
8
Vout(+)
Notes:
1) SENSE(–) should be connected to Vout(–) either remotely or
at the converter.
2) Leave TRIM pin open for nominal output voltage.
3) SENSE(+) should be connected to Vout(+) either remotely or
at the converter.
Doc.# 005-0005462 Rev. G
02/10/16
Page 28
Technical
Specification
IQ18xxxSKXxxx
PART NUMBERING SYSTEM
ORDERING INFORMATION
The part numbering system for SynQor’s dc-dc converters follows the format
shown in the example below.
The tables below show the valid model numbers and ordering options for
converters in this product family. When ordering SynQor converters, please
ensure that you use the complete 15 character part number consisting of
the 12 character base part number and the additional characters for options.
InQor units are only available with 6/6 RoHS compliance indicated by "-G".
IQ 1 8 0 1 2 S K C 2 0 N R S - G
IQ18012SKw20xyz
IQ18015SKw16xyz
IQ18018SKw14xyz
IQ18025SKw10xyz
IQ18033SKw08xyz
IQ18050SKw05xyz
IQ18070SKw04xyz
IQ18120SKw02xyz
IQ18150SKw02xyz
Options
(see
Ordering Information)
Output Current
Thermal Design
Performance Level
Package Size
Output Voltage
Input Voltage
Product Family
The first 12 characters comprise the base part number and the last 3
characters indicate available options. The “-G” suffix indicates 6/6 RoHS
compliance.
Application Notes
A variety of application notes and technical white papers can be downloaded
in pdf format from our website.
Input
Voltage
18 V
18 V
18 V
18 V
18 V
18 V
18 V
18 V
18 V
Model Number
6/6 RoHS
Output
Voltage
1.2 V
1.5 V
1.8 V
2.5 V
3.3 V
5V
7V
12 V
15 V
Max Output
Current
20 A
16 A
14 A
10 A
8A
5A
3.5 A
2A
1.7 A
The following options must be included in place of the w x y z spaces in the
model numbers listed above.
Thermal Design
w
Options Description
Enable Logic Pin Style
x
y
C - Encased
V - Encased with
Flanged Baseplate
N - Negative
Feature Set
z
R - 0.180"
S - Standard
RoHS Compliance: The EU led RoHS (Restriction of Hazardous
Substances) Directive bans the use of Lead, Cadmium, Hexavalent
Chromium, Mercury, Polybrominated Biphenyls (PBB), and Polybrominated
Diphenyl Ether (PBDE) in Electrical and Electronic Equipment. This SynQor
product is 6/6 RoHS compliant. For more information please refer to
SynQor’s RoHS addendum available at our RoHS Compliance / Lead
Free Initiative web page or e-mail us at [email protected].
Not all combinations make valid part numbers, please contact SynQor for
availability.
Contact SynQor for further information and to order:
PATENTS
Phone:
Toll Free:
Fax:
E-mail:
Web:
Address:
Product # IQ18xxxSKXxxx
978-849-0600
888-567-9596
978-849-0602
[email protected]
www.synqor.com
155 Swanson Road
Boxborough, MA 01719
USA
Phone 1-888-567-9596
SynQor holds numerous U.S. patents, one or more of which apply to most of its power converter
products. Any that apply to the product(s) listed in this document are identified by markings on
the product(s) or on internal components of the product(s) in accordance with U.S. patent laws.
SynQor’s patents include the following:
5,999,417
6,222,742
6,545,890
6,594,159
6,731,520
6,894,468
6,896,526
6,927,987
7,050,309
7,072,190
7,085,146
7,119,524
7,269,034
7,272,021
7,272,023
7,558,083
7,564,702
7,765,687
7,787,261
8,023,290
8,149,597
8,493,751
8,644,027
9,143,042
Warranty
SynQor offers a two (2) year limited warranty. Complete warranty
information is listed on our website or is available upon request from
SynQor.
www.synqor.com
Doc.# 005-0005462 Rev. G
02/10/16
Page 29