60A

Technical
Specification
IQ18xxxHPXxxx
9-36V
40V
Continuous Input Transient Input
1.8-48V
182W
2250V dc
Half-brick
Outputs
Max Power
Isolation
DC-DC Converter
The InQor® half-brick converter series is composed
of next-generation, board-mountable, isolated, fixed
switching frequency dc-dc converters that use synchronous
rectification to achieve extremely high power conversion
efficiency. Each module is supplied completely encased to
provide protection from the harsh environments seen in
many industrial and transportation applications.
NRS
8HPC60
IQ1801CONVERTER
DC-DC 1.8V T @ 60A
OU
9-36V IN
Operational Features
•
•
•
•
•
-G
High efficiency, 90% at full rated load current
Delivers full power with minimal derating - no heatsink required
Operating input voltage range: 9-36V
Fixed frequency switching provides predictable EMI
No minimum load requirement
Protection Features
Mechanical Features
• Industry standard half-brick pin-out
• Standard size: 2.386" x 2.486" x 0.512", 60.6 x 63.1 x 13.0 mm
• Total weight: 4.7oz (134g)
• Flanged baseplate version available
•
•
•
•
•
Input under-voltage lockout
Output current limit and short circuit protection
Active back bias limit
Output over-voltage protection
Thermal shutdown
Control Features
• On/Off control referenced to input side
• Remote sense for the output voltage
• Output voltage trim range of -20%, +10%
Safety Features
•
•
•
•
UL 60950-1/R:2011-12 Basic Insulation
CAN/CSA-C22.2 No. 60950-1/A1:2011
EN 60950-1/A12:2011
RoHS compliant (see last page)
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
CONTENTS
Page No.
Family Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.8Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . . 4
3.3Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . . 6
5.0Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . . 8
12Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 10
15Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 12
24Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 14
28Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 16
40Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 18
48Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 20
Application Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Standards & Qualification Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Standard Mechanical Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Flanged Mechanical Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 1
Technical
Specification
IQ18xxxHPXxxx
IQ18 Family Electrical Characteristics (all output voltages)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 18V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max.
ABSOLUTE MAXIMUM RATINGS
Input Voltage
Non-Operating
-1
40
Operating
36
Operating Transient Protection
40
Isolation Voltage
Input to Output
2250
Input to Base-Plate
2250
Output to Base-Plate
2250
Operating Temperature
-40
100
Storage Temperature
-45
125
Voltage at ON/OFF input pin
-2
18
INPUT CHARACTERISTICS
Operating Input Voltage Range
9
18
36
Input Under-Voltage Lockout
Turn-On Voltage Threshold
9.8
10.1
10.4
Turn-Off Voltage Threshold
8.2
8.4
8.7
Lockout Voltage Hysteresis
1.7
Input Over-Voltage Shutdown
Recommended External Input Capacitance
820
Input Filter Component Values (L\C)
0.34\32
DYNAMIC CHARACTERISTICS
Turn-On Transient
Turn-On Time
10
Start-Up Inhibit Time
200
230
250
Output Voltage Overshoot
0
ISOLATION CHARACTERISTICS
Isolation Voltage (dielectric strength)
Isolation Resistance
30
Isolation Capacitance (input to output)
1000
TEMPERATURE LIMITS FOR POWER DERATING CURVES
Semiconductor Junction Temperature
125
Board Temperature
125
Transformer Temperature
125
Maximum Baseplate Temperature, Tb
100
FEATURE CHARACTERISTICS
Switching Frequency
255
275
295
ON/OFF Control
Off-State Voltage
2.4
1.8
On-State Voltage
-2
0.8
ON/OFF Control
Pull-Up Voltage
5
Pull-Up Resistance
50
Over-Temperature Shutdown OTP Trip Point
125
Over-Temperature Shutdown Restart Hysteresis
10
RELIABILITY CHARACTERISTICS
Calculated MTBF (Telcordia) TR-NWT-000332
1.44
Calculated MTBF (MIL-217) MIL-HDBK-217F
1.20
Field Demonstrated MTBF
Note 1: Start-up guaranteed above 10.4 V, but will operate down to 9V
Note 2: Higher values of isolation capacitance can be added external to the module.
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
Units Notes & Conditions
V
V
V
V dc
V dc
V dc
°C
°C
V
V
Continuous
Continuous
100 ms transient, square wave
Baseplate temperature
40 V transient for 100 ms; see Note 1
V
V
V
V
µF
µH\µF
Not Available
Typical ESR 0.1-0.2 Ω
Internal values; see Figure E
ms
ms
%
Full load, Vout=90% nom.
Figure F
Maximum Output Capacitance
See Absolute Maximum Ratings
MΩ
pF
See Note 2
°C
°C
°C
°C
Package rated to 150 °C
UL rated max operating temp 130 °C
kHz
Isolation stage switching freq. is half this
V
Application notes Figures A & B
V
kΩ
°C
°C
Average PCB Temperature
106 Hrs. Tb = 70°C
106 Hrs. Tb = 70°C
106 Hrs. See our website for details
Doc.# 005-0005305 Rev. E
11/22/13
Page 2
Technical
Specification
IQ18xxxHPXxxx
Family Figures (all output voltages)
120
Typical Current Limit Inception Point
Nominal Vout
Output Voltage (%)
100
80
Typical Output Voltage at Shutdown
60
40
Vin min
Vin nom
20
Vin max
0
0
Common Figure 1: Typical startup waveform. Input voltage pre-applied, ON/
OFF Pin on Ch 2.
20
30
40
50
60
70
80
90
100 110 120 130 140 150
Load Current (%)
Common Figure 2: Output voltage vs. load current showing typical current limit
curves and converter shutdown points.
100,000.0
100,000.0
1.8 V
10,000.0
3.3 V
5V
12 V
15 V
Trim Resistance (kOhms)
Trim Resistance (kOhms)
10
1,000.0
100.0
10.0
24 V
28 V
40 V
48 V
10,000.0
1,000.0
100.0
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
Increase in Vout (%)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Increase in Vout (%)
Common Figure 3: Trim graph for trim-up 1.8 to 12 V outputs.
Common Figure 4: Trim graph for trim-up 15 to 48 V outputs.
10,000.0
Trim Resistance (kOhms)
All voltages
1,000.0
100.0
10.0
0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20
Decrease in Vout (%)
Common Figure 5: Trim graph for trim down.
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 3
Input:9-36V
Output:1.8V
Current:60A
Part No.:IQ18018HPx60
Technical Specification
IQ18018HPx60 Electrical Characteristics (1.8 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 18V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max.
Units Notes & Conditions
INPUT CHARACTERISTICS
Maximum Input Current
19.3
A
Vin min; trim up; in current limit
No-Load Input Current
190
240
mA
Disabled Input Current
3
4
mA
Response to Input Transient
0.09
V
See Figure 6
Input Terminal Ripple Current
350
mA
RMS
Recommended Input Fuse
30
A
Fast acting external fuse recommended
OUTPUT CHARACTERISTICS
Output Voltage Set Point
1.782
1.800
1.818
V
Output Voltage Regulation
Over Line
±0.1
±0.3
%
Over Load
±0.1
±0.3
%
Over Temperature
-27
27
mV
Total Output Voltage Range
1.755
1.845
V
Over sample, line, load, temperature & life
Output Voltage Ripple and Noise
20 MHz bandwidth; see Note 1
Peak-to-Peak
0
100
200
mV
Full load
RMS
21
40
mV
Full load
A
Operating Output Current Range
0
60
Subject to thermal derating
Output DC Current-Limit Inception
66.0
72.0
78.0
A
Output voltage 10% Low
Output DC Current-Limit Shutdown Voltage
0.8
V
Back-Drive Current Limit while Enabled
0.8
A
Negative current drawn from output
Back-Drive Current Limit while Disabled
0.1
mA
Negative current drawn from output
Maximum Output Capacitance
15,000
µF
Vout nominal at full load (resistive load)
Output Voltage during Load Current Transient
Step Change in Output Current (0.1 A/µs)
100
mV
50% to 75% to 50% Iout max
Settling Time
400
µs
To within 1% Vout nom
Output Voltage Trim Range
-20
10
%
Across Pins 8&4; Common Figures 3-5; see Note 2
Output Voltage Remote Sense Range
10
%
Across Pins 8&4
Output Over-Voltage Protection
2.1
2.2
2.3
V
Over full temp range
EFFICIENCY
100% Load
82
%
See Figure 1 for efficiency curve
50% Load
86
%
See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and
noise, consult SynQor applications support (e-mail: [email protected])
Note 2: Trim-up range is limited below 10% at low line and full load.
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 4
Input:9-36V
Output:1.8V
Current:60A
Part No.:IQ18018HPx60
Technical Specification
100
27
95
24
21
Power Dissipation (W)
Efficiency (%)
90
85
80
75
70
10 Vin
18 Vin
65
18
15
12
9
6
10 Vin
18 Vin
3
36 Vin
60
36 Vin
0
0
10
20
30
Load Current (A)
40
50
60
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
0
10
20
30
Load Current (A)
40
50
60
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
70
60
60
50
50
40
40
Iout (A)
Iout (A)
70
30
30
400
300
200
100
20
10
LFM (2.0
LFM (1.5
LFM (1.0
LFM (0.5
m/s)
m/s)
m/s)
m/s)
400
300
200
100
20
10
LFM (2.0
LFM (1.5
LFM (1.0
LFM (0.5
m/s)
m/s)
m/s)
m/s)
0
0
25
40
55
70
25
85
Ambient Air Temperature (°C)
40
55
Ambient Air Temperature (°C)
70
85
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF
ceramic cap. Ch 1: Vout, Ch 2: Iout.
Figure 6: Output voltage response to step-change in input voltage (Vnom.-VmaxVnom.), at Max. load current. Load cap: 15µF tantalum capacitor and 1uF
ceramic cap. Ch 1: Vout, Ch 2: Vin.
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 5
Input:9-36V
Output:3.3V
Current:50A
Part No.:IQ18033HPx50
Technical Specification
IQ18033HPx50 Electrical Characteristics (3.3 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 18V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max.
Units Notes & Conditions
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current
Disabled Input Current
28.0
A
210
260
mA
3
4
mA
Response to Input Transient
0.16
V
Input Terminal Ripple Current
440
mA
Recommended Input Fuse
30
A
3.300
3.333
V
±0.1
±0.3
%
±0.1
Vin min; trim up; in current limit
500 V/ms; see Figure 6
RMS
Fast acting external fuse recommended
OUTPUT CHARACTERISTICS
Output Voltage Set Point
3.267
Output Voltage Regulation
Over Line
Over Load
Over Temperature
Total Output Voltage Range
±0.3
%
-50
50
mV
3.217
3.383
V
80
160
mV
Full load
12
20
mV
Full load
50
A
Subject to thermal derating
65.0
A
Output voltage 10% Low
Output Voltage Ripple and Noise
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Peak-to-Peak
0
RMS
Operating Output Current Range
0
Output DC Current-Limit Inception
55.0
60.0
Output DC Current-Limit Shutdown Voltage
1.8
V
Back-Drive Current Limit while Enabled
1.5
A
Negative current drawn from output
Back-Drive Current Limit while Disabled
0.1
mA
Negative current drawn from output
µF
Vout nominal at full load (resistive load)
Maximum Output Capacitance
10,000
Output Voltage during Load Current Transient
Step Change in Output Current (0.1 A/µs)
120
mV
50% to 75% to 50% Iout max
Settling Time
200
µs
To within 1% Vout nom
10
%
Across Pins 8&4; Common Figures 3-5; see Note 2
10
%
Across Pins 8&4
4.2
V
Over full temp range
%
See Figure 1 for efficiency curve
Output Voltage Trim Range
-20
Output Voltage Remote Sense Range
Output Over-Voltage Protection
3.9
4.0
EFFICIENCY
100% Load
86
50% Load
89
%
See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and
noise, consult SynQor applications support (e-mail: [email protected])
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 6
Input:9-36V
Output:3.3V
Current:50A
Part No.:IQ18033HPx50
Technical Specification
30
100
95
25
Power Dissipation (W)
Efficiency (%)
90
85
80
75
70
10 Vin
15
10
10 Vin
5
18 Vin
65
20
18 Vin
36 Vin
36 Vin
60
0
0
10
20
30
40
Load Current (A)
50
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
0
10
20
30
40
Load Current (A)
50
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
60
50
50
40
40
Iout (A)
Iout (A)
60
30
30
20
400
300
200
100
10
LFM (2.0
LFM (1.5
LFM (1.0
LFM (0.5
20
m/s)
m/s)
m/s)
m/s)
400
300
200
100
10
LFM (2.0
LFM (1.5
LFM (1.0
LFM (0.5
m/s)
m/s)
m/s)
m/s)
0
0
25
40
55
70
25
85
Ambient Air Temperature (°C)
40
55
Ambient Air Temperature (°C)
70
85
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF
ceramic cap. Ch 1: Vout, Ch 2: Iout.
Figure 6: Output voltage response to step-change in input voltage (Vnom.-VmaxVnom.), at Max. load current. Load cap: 15µF tantalum capacitor and 1uF
ceramic cap. Ch 1: Vout, Ch 2: Vin.
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 7
Input:9-36V
Output:5V
Current:36A
Part No.:IQ18050HPx36
Technical Specification
IQ18050HPx36 Electrical Characteristics (5.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 18V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max.
Units Notes & Conditions
30
A
200
250
mA
3
4
mA
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current
Disabled Input Current
Response to Input Transient
0.3
V
Input Terminal Ripple Current
480
mA
Recommended Input Fuse
30
A
5.00
5.05
V
±0.1
±0.3
%
±0.1
Vin min; trim up; in current limit
300 V/ms; see Figure 6
RMS
Fast acting external fuse recommended
OUTPUT CHARACTERISTICS
Output Voltage Set Point
4.95
Output Voltage Regulation
Over Line
Over Load
Over Temperature
Total Output Voltage Range
±0.3
%
-75
75
mV
4.875
5.125
V
120
240
mV
Full load
16
30
mV
Full load
36
A
Subject to thermal derating
46.8
A
Output voltage 10% Low
Output Voltage Ripple and Noise
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Peak-to-Peak
0
RMS
Operating Output Current Range
0
Output DC Current-Limit Inception
39.6
43.2
Output DC Current-Limit Shutdown Voltage
2.7
V
Back-Drive Current Limit while Enabled
0.75
A
Negative current drawn from output
Back-Drive Current Limit while Disabled
0.4
mA
Negative current drawn from output
µF
Vout nominal at full load (resistive load)
Maximum Output Capacitance
8,000
Output Voltage during Load Current Transient
Step Change in Output Current (0.1 A/µs)
170
mV
50% to 75% to 50% Iout max
Settling Time
300
µs
To within 1% Vout nom
10
%
Across Pins 8&4; Common Figures 3-5; see Note 2
10
%
Across Pins 8&4
6.4
V
Over full temp range
%
See Figure 1 for efficiency curve
Output Voltage Trim Range
-20
Output Voltage Remote Sense Range
Output Over-Voltage Protection
5.9
6.1
EFFICIENCY
100% Load
88
50% Load
90
%
See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and
noise, consult SynQor applications support (e-mail: [email protected])
Note 2: Trim-up range is limited below 10% at low line and full load.
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 8
Input:9-36V
Output:5V
Current:36A
Part No.:IQ18050HPx36
Technical Specification
30
100
95
25
Power Dissipation (W)
Efficiency (%)
90
85
80
75
70
9 Vin
10
9 Vin
18 Vin
36 Vin
36 Vin
60
0
0
4
8
12
16
20
Load Current (A)
24
28
32
36
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
0
40
40
36
36
32
32
28
28
24
24
20
16
400
300
200
100
12
8
4
LFM (2.0
LFM (1.5
LFM (1.0
LFM (0.5
4
8
12
16
20
Load Current (A)
24
28
32
36
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
Iout (A)
Iout (A)
15
5
18 Vin
65
20
m/s)
m/s)
m/s)
m/s)
20
16
400
300
200
100
12
8
4
LFM (2.0
LFM (1.5
LFM (1.0
LFM (0.5
m/s)
m/s)
m/s)
m/s)
0
0
25
40
55
70
25
85
40
55
70
85
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF
ceramic cap. Ch 1: Vout, Ch 2: Iout.
Figure 6: Output voltage response to step-change in input voltage (Vnom.-VmaxVnom.), at Max. load current. Load cap: 15µF tantalum capacitor and 1uF
ceramic cap. Ch 1: Vout, Ch 2: Vin.
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 9
Input:9-36V
Output:12V
Current:15A
Part No.:IQ18120HPx15
Technical Specification
IQ18120HPx15 Electrical Characteristics (12.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 18V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max.
Units Notes & Conditions
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current
Disabled Input Current
29.2
A
280
350
mA
3
4
mA
Response to Input Transient
0.5
V
Input Terminal Ripple Current
450
mA
Recommended Input Fuse
30
A
12.00
12.12
V
±0.1
±0.3
%
±0.1
Vin min; trim up; in current limit
500 V/ms; see Figure 6
RMS
Fast acting external fuse recommended
OUTPUT CHARACTERISTICS
Output Voltage Set Point
11.88
Output Voltage Regulation
Over Line
Over Load
±0.3
%
Over Temperature
-180
180
mV
Total Output Voltage Range
11.70
12.30
V
40
80
mV
Full load
10
20
mV
Full load
15
A
Subject to thermal derating
19.5
A
Output voltage 10% Low
Output Voltage Ripple and Noise
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Peak-to-Peak
0
RMS
Operating Output Current Range
0
Output DC Current-Limit Inception
16.5
18.0
Output DC Current-Limit Shutdown Voltage
6.5
V
Back-Drive Current Limit while Enabled
0.6
A
Negative current drawn from output
Back-Drive Current Limit while Disabled
1
mA
Negative current drawn from output
µF
Vout nominal at full load (resistive load)
Maximum Output Capacitance
1,500
Output Voltage during Load Current Transient
Step Change in Output Current (0.1 A/µs)
380
mV
50% to 75% to 50% Iout max
Settling Time
80
µs
To within 1% Vout nom
10
%
Across Pins 8&4; Common Figures 3-5; see Note 2
10
%
Across Pins 8&4
15.240
V
Over full temp range
%
See Figure 1 for efficiency curve
Output Voltage Trim Range
-20
Output Voltage Remote Sense Range
Output Over-Voltage Protection
14.040
14.640
EFFICIENCY
100% Load
90
50% Load
91
%
See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and
noise, consult SynQor applications support (e-mail: [email protected])
Note 2: Trim-up range is limited below 10% at low line and full load.
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 10
Input:9-36V
Output:12V
Current:15A
Part No.:IQ18120HPx15
100
24
95
21
90
18
Power Dissipation (W)
Efficiency (%)
Technical Specification
85
80
75
70
10 Vin
18 Vin
65
15
12
9
6
36 Vin
60
3
6
9
12
Load Current (A)
15
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
15
12
12
Iout (A)
15
9
400
300
200
100
LFM (2.0
LFM (1.5
LFM (1.0
LFM (0.5
3
6
9
12
Load Current (A)
15
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
18
Iout (A)
36 Vin
0
18
3
18 Vin
0
0
6
10 Vin
3
9
6
m/s)
m/s)
m/s)
m/s)
400
300
200
100
3
LFM (2.0
LFM (1.5
LFM (1.0
LFM (0.5
m/s)
m/s)
m/s)
m/s)
0
0
25
40
55
70
25
85
Ambient Air Temperature (°C)
40
55
Ambient Air Temperature (°C)
70
85
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF
ceramic cap. Ch 1: Vout, Ch 2: Iout.
Figure 6: Output voltage response to step-change in input voltage (Vnom.-VmaxVnom.), at Max. load current. Load cap: 15µF tantalum capacitor and 1uF
ceramic cap. Ch 1: Vout, Ch 2: Vin.
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 11
Input:9-36V
Output:15V
Current:12A
Part No.:IQ18150HPx12
Technical Specification
IQ18150HPx12 Electrical Characteristics (15.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 18V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max.
Units Notes & Conditions
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current
Disabled Input Current
29.3
A
250
310
mA
3
4
mA
Response to Input Transient
0.6
V
Input Terminal Ripple Current
550
mA
Recommended Input Fuse
30
A
15.00
15.15
V
±0.1
±0.3
%
±0.1
Vin min; trim up; in current limit
500 V/ms; see Figure 6
RMS
Fast acting external fuse recommended
OUTPUT CHARACTERISTICS
Output Voltage Set Point
14.85
Output Voltage Regulation
Over Line
Over Load
±0.3
%
Over Temperature
-225
225
mV
Total Output Voltage Range
14.62
15.38
V
75
150
mV
Full load
10
20
mV
Full load
12
A
Subject to thermal derating
15.6
A
Output voltage 10% Low
Output Voltage Ripple and Noise
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Peak-to-Peak
0
RMS
Operating Output Current Range
0
Output DC Current-Limit Inception
13.2
14.4
Output DC Current-Limit Shutdown Voltage
8.5
V
Back-Drive Current Limit while Enabled
0.4
A
Negative current drawn from output
Back-Drive Current Limit while Disabled
1.5
mA
Negative current drawn from output
µF
Vout nominal at full load (resistive load)
Maximum Output Capacitance
1,000
Output Voltage during Load Current Transient
Step Change in Output Current (0.1 A/µs)
720
mV
50% to 75% to 50% Iout max
Settling Time
80
µs
To within 1% Vout nom
10
%
Across Pins 8&4; Common Figures 3-5; see Note 2
10
%
Across Pins 8&4
19.1
V
Over full temp range
%
See Figure 1 for efficiency curve
Output Voltage Trim Range
-20
Output Voltage Remote Sense Range
Output Over-Voltage Protection
17.6
18.3
EFFICIENCY
100% Load
90
50% Load
91
%
See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and
noise, consult SynQor applications support (e-mail: [email protected])
Note 2: Trim-up range is limited below 10% at low line and full load.
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 12
Input:9-36V
Output:15V
Current:12A
Part No.:IQ18150HPx12
100
24
95
21
90
18
Power Dissipation (W)
Efficiency (%)
Technical Specification
85
80
75
70
10 Vin
18 Vin
65
15
12
9
6
36 Vin
60
2
4
6
Load Current (A)
8
10
12
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
10
8
8
Iout (A)
10
6
400
300
200
100
LFM (2.0
LFM (1.5
LFM (1.0
LFM (0.5
2
4
6
Load Current (A)
8
10
12
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
12
Iout (A)
36 Vin
0
12
2
18 Vin
0
0
4
10 Vin
3
6
4
m/s)
m/s)
m/s)
m/s)
400
300
200
100
2
0
LFM (2.0
LFM (1.5
LFM (1.0
LFM (0.5
m/s)
m/s)
m/s)
m/s)
0
25
40
55
70
85
25
Ambient Air Temperature (°C)
40
55
Ambient Air Temperature (°C)
70
85
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF
ceramic cap. Ch 1: Vout, Ch 2: Iout.
Figure 6: Output voltage response to step-change in input voltage (Vnom.-VmaxVnom.), at Max. load current. Load cap: 15µF tantalum capacitor and 1uF
ceramic cap. Ch 1: Vout, Ch 2: Vin.
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 13
Input:9-36V
Output:24V
Current:7.5A
Part No.:IQ18240HPx7F
Technical Specification
IQ18240HPx7F Electrical Characteristics (24.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 18V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max.
Units Notes & Conditions
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current
Disabled Input Current
29.6
A
200
250
mA
2
4
mA
Response to Input Transient
0.9
V
Input Terminal Ripple Current
550
mA
Recommended Input Fuse
30
A
24.00
24.24
V
±0.1
±0.3
%
±0.1
Vin min; trim up; in current limit
500 V/ms; see Figure 6
RMS
Fast acting external fuse recommended
OUTPUT CHARACTERISTICS
Output Voltage Set Point
23.76
Output Voltage Regulation
Over Line
Over Load
±0.3
%
Over Temperature
-360
360
mV
Total Output Voltage Range
23.40
24.60
V
200
mV
Full load
Full load
Output Voltage Ripple and Noise
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Peak-to-Peak
0
RMS
100
19
Operating Output Current Range
0
Output DC Current-Limit Inception
8.3
9.0
40
mV
7.5
A
Subject to thermal derating
9.8
A
Output voltage 10% Low
Output DC Current-Limit Shutdown Voltage
14
V
Back-Drive Current Limit while Enabled
0.2
A
Negative current drawn from output
Back-Drive Current Limit while Disabled
2.5
mA
Negative current drawn from output
µF
Vout nominal at full load (resistive load)
1500
mV
50% to 75% to 50% Iout max
80
µs
To within 1% Vout nom
10
%
Across Pins 8&4; Common Figures 3-5; see Note 2
10
%
Across Pins 8&4
30.5
V
Over full temp range
%
See Figure 1 for efficiency curve
Maximum Output Capacitance
400
Output Voltage during Load Current Transient
Step Change in Output Current (0.1 A/µs)
Settling Time
Output Voltage Trim Range
-20
Output Voltage Remote Sense Range
Output Over-Voltage Protection
28.1
29.3
EFFICIENCY
100% Load
89
50% Load
91
%
See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications
support (e-mail: [email protected])
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 14
Input:9-36V
Output:24V
Current:7.5A
Part No.:IQ18240HPx7F
Technical Specification
95
21
90
18
Power Dissipation (W)
24
Efficiency (%)
100
85
80
75
70
15
12
9 Vin
18 Vin
65
9
6
9 Vin
18 Vin
3
36 Vin
60
36 Vin
0
0.0
1.5
3.0
4.5
6.0
Load Current (A)
7.5
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
0.0
1.5
3.0
4.5
6.0
Load Current (A)
7.5
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
8
7
7
6
6
5
5
Iout (A)
Iout (A)
8
4
4
3
3
400
300
200
100
2
1
LFM (2.0
LFM (1.5
LFM (1.0
LFM (0.5
m/s)
m/s)
m/s)
m/s)
400
300
200
100
2
1
LFM (2.0
LFM (1.5
LFM (1.0
LFM (0.5
m/s)
m/s)
m/s)
m/s)
0
0
25
40
55
70
25
85
40
55
70
85
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 1µF ceramic cap. Ch 1: Vout, Ch
2: Iout.
Figure 6: Output voltage response to step-change in input voltage (Vnom.-VmaxVnom.), at Max. load current. Load cap: 1uF ceramic cap. Ch 1: Vout, Ch 2: Vin.
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 15
Input:9-36V
Output:28V
Current:6.5A
Part No.:IQ18280HPx6F
Technical Specification
IQ18280HPx6F Electrical Characteristics (28.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 18V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max.
Units Notes & Conditions
INPUT CHARACTERISTICS
Maximum Input Current
29.9
A
No-Load Input Current
230
290
mA
Disabled Input Current
2
4
mA
Response to Input Transient
1
V
550
mA
Input Terminal Ripple Current
Recommended Input Fuse
30
A
28.00
28.28
V
±0.1
±0.3
%
±0.1
Vin min; trim up; in current limit
500 V/ms; see Figure 6
RMS
Fast acting external fuse recommended
OUTPUT CHARACTERISTICS
Output Voltage Set Point
27.72
Output Voltage Regulation
Over Line
Over Load
±0.3
%
Over Temperature
-420
420
mV
Total Output Voltage Range
27.30
28.70
V
130
mV
Full load
Full load
Output Voltage Ripple and Noise
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Peak-to-Peak
0
RMS
65
11
Operating Output Current Range
0
Output DC Current-Limit Inception
7.2
7.8
20
mV
6.5
A
Subject to thermal derating
8.5
A
Output voltage 10% Low
Output DC Current-Limit Shutdown Voltage
16
V
Back-Drive Current Limit while Enabled
0.2
A
Negative current drawn from output
Back-Drive Current Limit while Disabled
3
mA
Negative current drawn from output
µF
Vout nominal at full load (resistive load)
1900
mV
50% to 75% to 50% Iout max
80
µs
To within 1% Vout nom
10
%
Across Pins 8&4; Common Figures 3-5; see Note 2
10
%
Across Pins 8&4
35.6
V
Over full temp range
%
See Figure 1 for efficiency curve
Maximum Output Capacitance
250
Output Voltage during Load Current Transient
Step Change in Output Current (0.1 A/µs)
Settling Time
Output Voltage Trim Range
-20
Output Voltage Remote Sense Range
Output Over-Voltage Protection
32.8
34.2
EFFICIENCY
100% Load
89
50% Load
91
%
See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications
support (e-mail: [email protected])
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 16
Input:9-36V
Output:28V
Current:6.5A
Part No.:IQ18280HPx6F
Technical Specification
100
27
95
24
21
Power Dissipation (W)
Efficiency (%)
90
85
80
75
70
18
15
12
9 Vin
18 Vin
65
9
6
9 Vin
18 Vin
3
36 Vin
60
36 Vin
0
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
Load Current (A)
4.5
5.0
5.5
6.0
6.5
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
Load Current (A)
4.5
5.0
5.5
6.0
6.5
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
7
6
6
5
5
4
4
Iout (A)
Iout (A)
7
3
3
400
300
200
100
2
1
LFM (2.0
LFM (1.5
LFM (1.0
LFM (0.5
m/s)
m/s)
m/s)
m/s)
400
300
200
100
2
1
LFM (2.0
LFM (1.5
LFM (1.0
LFM (0.5
m/s)
m/s)
m/s)
m/s)
0
0
25
40
55
70
25
85
40
55
70
85
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 1µF ceramic cap. Ch 1: Vout, Ch
2: Iout.
Figure 6: Output voltage response to step-change in input voltage (Vnom.-VmaxVnom.), at Max. load current. Load cap: 1uF ceramic cap. Ch 1: Vout, Ch 2: Vin.
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 17
Input:9-36V
Output:40V
Current:4.5A
Part No.:IQ18400HPx4F
Technical Specification
IQ18400HPx4F Electrical Characteristics (40.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 18V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current
Disabled Input Current
Response to Input Transient
Input Terminal Ripple Current
Recommended Input Fuse
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Line
Over Load
Over Temperature
Total Output Voltage Range
Output Voltage Ripple and Noise
Peak-to-Peak
RMS
Operating Output Current Range
Output DC Current-Limit Inception
Output DC Current-Limit Shutdown Voltage
Back-Drive Current Limit while Enabled
Back-Drive Current Limit while Disabled
Maximum Output Capacitance
Output Voltage during Load Current Transient
Step Change in Output Current (0.1 A/µs)
Settling Time
Output Voltage Trim Range
Typ.
Max.
Units
29.7
300
4
30
A
mA
mA
V
mA
A
40.00
40.40
V
±0.1
±0.1
±0.3
±0.3
600
41.00
%
%
mV
V
280
40
4.5
5.9
mV
mV
A
A
V
A
mA
µF
240
2
1.75
310
39.60
-600
39.00
0
0
5.0
140
20
5.4
26
0.15
4
150
2300
80
-20
mV
µs
10
%
Output Voltage Remote Sense Range
10
Output Over-Voltage Protection
46.8
48.8
50.8
EFFICIENCY
100% Load
89
50% Load
91
Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced
applications support (e-mail: [email protected])
Note 2: Trim-up range is limited below 10% at low line and full load.
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
%
V
Notes & Conditions
Vin min; trim up; in current limit
500 V/ms; see Figure 6
RMS
Fast acting external fuse recommended
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Full load
Full load
Subject to thermal derating
Output voltage 10% Low
Negative current drawn from output
Negative current drawn from output
Vout nominal at full load (resistive load)
50% to 75% to 50% Iout max
To within 1% Vout nom
Across Pins 8&4; Common Figures 3-5; see Note
2
Across Pins 8&4
Over full temp range
%
See Figure 1 for efficiency curve
%
See Figure 1 for efficiency curve
output voltage ripple and noise, consult SynQor
Doc.# 005-0005305 Rev. E
11/22/13
Page 18
Input:9-36V
Output:40V
Current:4.5A
Part No.:IQ18400HPx4F
Technical Specification
100
27
95
24
21
Power Dissipation (W)
Efficiency (%)
90
85
80
75
70
10 Vin
18 Vin
65
18
15
12
9
6
10 Vin
18 Vin
3
36 Vin
60
36 Vin
0
0.0
0.5
1.0
1.5
2.0
2.5
Load Current (A)
3.0
3.5
4.0
4.5
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
0.0
0.5
1.0
1.5
2.0
2.5
Load Current (A)
3.0
3.5
4.0
4.5
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
5.0
4.5
4.5
4.0
4.0
3.5
3.5
3.0
3.0
Iout (A)
Iout (A)
5.0
2.5
2.5
2.0
2.0
1.5
400
300
200
100
1.0
0.5
LFM (2.0
LFM (1.5
LFM (1.0
LFM (0.5
400
300
200
100
1.5
m/s)
m/s)
m/s)
m/s)
1.0
0.5
LFM (2.0
LFM (1.5
LFM (1.0
LFM (0.5
m/s)
m/s)
m/s)
m/s)
0.0
0.0
25
40
55
70
25
85
Ambient Air Temperature (°C)
40
55
Ambient Air Temperature (°C)
70
85
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 1µF ceramic cap. Ch 1: Vout, Ch
2: Iout.
Figure 6: Output voltage response to step-change in input voltage (Vnom.-VmaxVnom.), at Max. load current. Load cap: 1uF ceramic cap. Ch 1: Vout, Ch 2: Vin.
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 19
Input:9-36V
Output:48V
Current:3.7A
Part No.:IQ18480HPx3H
Technical Specification
IQ18480HPx3H Electrical Characteristics (48.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 18V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max.
Units Notes & Conditions
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current
Disabled Input Current
29.2
A
300
350
mA
2
3
mA
Response to Input Transient
2.4
V
Input Terminal Ripple Current
520
mA
Recommended Input Fuse
30
A
48.00
48.48
V
±0.1
±0.3
%
±0.1
Vin min; trim up; in current limit
500 V/ms; see Figure 6
RMS
Fast acting external fuse recommended
OUTPUT CHARACTERISTICS
Output Voltage Set Point
47.52
Output Voltage Regulation
Over Line
Over Load
±0.3
%
Over Temperature
-720
720
mV
Total Output Voltage Range
46.80
49.20
V
250
mV
Full load
Full load
Output Voltage Ripple and Noise
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Peak-to-Peak
0
RMS
125
20
Operating Output Current Range
0
Output DC Current-Limit Inception
4.07
4.44
40
mV
3.7
A
Subject to thermal derating
4.81
A
Output voltage 10% Low
Output DC Current-Limit Shutdown Voltage
25
V
Back-Drive Current Limit while Enabled
0.1
A
Negative current drawn from output
Back-Drive Current Limit while Disabled
5
mA
Negative current drawn from output
µF
Vout nominal at full load (resistive load)
2800
mV
50% to 75% to 50% Iout max
80
µs
To within 1% Vout nom
10
%
Across Pins 8&4; Common Figures 3-5; see Note 2
10
%
Across Pins 8&4
61.0
V
Over full temp range
%
See Figure 1 for efficiency curve
Maximum Output Capacitance
100
Output Voltage during Load Current Transient
Step Change in Output Current (0.1 A/µs)
Settling Time
Output Voltage Trim Range
-20
Output Voltage Remote Sense Range
Output Over-Voltage Protection
56.2
58.6
EFFICIENCY
100% Load
89
50% Load
91
%
See Figure 1 for efficiency curve
Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications
support (e-mail: [email protected])
Note 2: Trim-up range is limited below 10% at low line and full load.
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 20
Input:9-36V
Output:48V
Current:3.7A
Part No.:IQ18480HPx3H
Technical Specification
100
27
95
24
21
Power Dissipation (W)
Efficiency (%)
90
85
80
75
70
10 Vin
18 Vin
65
18
15
12
9
6
10 Vin
18 Vin
3
36 Vin
60
36 Vin
0
0.0
0.5
1.0
1.5
2.0
Load Current (A)
2.5
3.0
3.5
0.0
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
0.5
1.0
1.5
2.0
Load Current (A)
2.5
3.0
3.5
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
4.0
3.5
3.5
3.0
3.0
2.5
2.5
Iout (A)
Iout (A)
4.0
2.0
2.0
1.5
1.5
400
300
200
100
1.0
0.5
LFM (2.0
LFM (1.5
LFM (1.0
LFM (0.5
m/s)
m/s)
m/s)
m/s)
400
300
200
100
1.0
0.5
LFM (2.0
LFM (1.5
LFM (1.0
LFM (0.5
m/s)
m/s)
m/s)
m/s)
0.0
0.0
25
40
55
70
25
85
Ambient Air Temperature (°C)
40
55
Ambient Air Temperature (°C)
70
85
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 1µF ceramic cap. Ch 1: Vout, Ch
2: Iout.
Figure 6: Output voltage response to step-change in input voltage (Vnom.-VmaxVnom.), at Max. load current. Load cap: 1uF ceramic cap. Ch 1: Vout, Ch 2: Vin.
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 21
Technical
Specification
IQ18xxxHPXxxx
Application Section
BASIC OPERATION AND FEATURES
CONTROL FEATURES
This converter series uses a two-stage power
topology. The first stage is a buck-converter that
output voltage constant over variations in line,
temperature. The second stage uses a transformer
the functions of input/output isolation and voltage
step-down to achieve the output voltage required.
REMOTE ON/OFF (Pin 2): The ON/OFF input, Pin 2, permits
the user to control when the converter is on or off. This input
is referenced to the return terminal of the input bus, Vin(-).
The ON/OFF signal is active low (meaning that a low turns the
converter on). Figure A details four possible circuits for driving
the ON/OFF pin. Figure B is a detailed look of the internal ON/
OFF circuitry.
conversion
keeps the
load, and
to provide
step-up or
Both the first stage and the second stage switch at a fixed
frequency for predictable EMI performance. Rectification of
the transformer’s output is accomplished with synchronous
rectifiers. These devices, which are MOSFETs with a very low
on-state resistance, dissipate far less energy than Schottky
diodes. This is the primary reason that the converter has such
high efficiency, even at very low output voltages and very high
output currents.
These converters are offered totally encased to withstand harsh
environments and thermally demanding applications. Dissipation
throughout the converter is so low that it does not require a
heatsink for operation in many applications; however, adding
a heatsink provides improved thermal derating performance in
extreme situations.
This series of converters use the industry standard footprint and
pin-out configuration.
ON/OFF
ON/OFF
Vin(_)
Vin(_)
Remote Enable Circuit
REMOTE SENSE(+) (Pins 7 and 5): The SENSE(+) inputs
correct for voltage drops along the conductors that connect the
converter’s output pins to the load.
Pin 7 should be connected to Vout(+) and Pin 5 should be
connected to Vout(-) at the point on the board where regulation
is desired. A remote connection at the load can adjust for a
voltage drop only as large as that specified in this datasheet,
that is
[Vout(+) - Vout(-)] – [Vsense(+) - Vsense(-)] <
Sense Range % x Vout
Pins 7 and 5 must be connected for proper regulation of
the output voltage. If these connections are not made, the
converter will deliver an output voltage that is slightly higher
than its specified value.
Note: the output over-voltage protection circuit senses the
voltage across the output (pins 8 and 4) to determine when
it should trigger, not the voltage across the converter’s sense
leads (pins 7 and 5). Therefore, the resistive drop on the board
should be small enough so that output OVP does not trigger,
even during load transients.
5V
Negative Logic
(Permanently Enabled)
5V
ON/OFF
TTL/
CMOS
50k
ON/OFF
ON/OFF
50k
TTL
Vin(_)
Vin(_ )
Open Collector Enable Circuit
100pF
Vin(-)
Direct Logic Drive
Figure A: Various circuits for driving the ON/OFF pin.
Product # IQ18xxxHPXxxx
.
Phone 1-888-567-9596
Figure B: Internal ON/OFF pin circuitry
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 22
Technical
Specification
IQ18xxxHPXxxx
Application Section
OUTPUT VOLTAGE TRIM (Pin 6): The TRIM input permits the
user to adjust the output voltage across the sense leads up or
down according to the trim range specifications.
To decrease the output voltage, the user should connect a
resistor between Pin 6 and Pin 5 (SENSE(-) input). For a desired
decrease of the nominal output voltage, the value of the resistor
should be
Rtrim-down =
- 10.22
(511
D% )
(kW)
where
D% =
Vnominal – Vdesired
Vnominal
x 100%
To increase the output voltage, the user should connect a
resistor between Pin 6 and Pin 7 (SENSE(+) input). For a desired
increase of the nominal output voltage, the value of the resistor
should be
Rtrim-up =
where
(
5.11VOUT x (100+D%)
1.225D%
_ 511 _ 10.22
D%
)
(kW)
Vout = Nominal Output Voltage
Trim graphs show the relationship between the trim resistor
value and Rtrim-up and Rtrim-down, showing the total range the
output voltage can be trimmed up or down.
Note: the TRIM feature does not affect the voltage at which the
output over-voltage protection circuit is triggered. Trimming the
output voltage too high may cause the over-voltage protection
circuit to engage, particularly during transients.
It is not necessary for the user to add capacitance at the
Trim pin. The node is internally bypassed to eliminate noise.
Total DC Variation of VOUT: For the converter to meet its
full specifications, the maximum variation of the dc value of
VOUT, due to both trimming and remote load voltage drops,
should not be greater than that specified for the output
voltage trim range.
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
PROTECTION FEATURES
Input Under-Voltage Lockout: The converter is designed
to turn off when the input voltage is too low, helping avoid an
input system instability problem, described in more detail in
the application note titled “Input System Instability” on our
website. The lockout circuitry is a comparator with dc hysteresis.
When the input voltage is rising, it must exceed the typical TurnOn Voltage Threshold value (listed on the specifications page)
before the converter will turn on. Once the converter is on,
the input voltage must fall below the typical Turn-Off Voltage
Threshold value before the converter will turn off.
Output Current Limit: The maximum current limit remains
constant as the output voltage drops. However, once the
impedance of the load across the output is small enough to make
the output voltage drop below the specified Output DC CurrentLimit Shutdown Voltage, the converter turns off.
The converter then enters a “hiccup mode” where it repeatedly
turns on and off at a 5 Hz (nominal) frequency with a 5% duty
cycle until the short circuit condition is removed. This prevents
excessive heating of the converter or the load board.
Output Over-Voltage Limit: If the voltage across the output
pins exceeds the Output Over-Voltage Protection threshold, the
converter will immediately stop switching. This prevents damage
to the load circuit due to 1) excessive series resistance in output
current path from converter output pins to sense point, 2) a
release of a short-circuit condition, or 3) a release of a current
limit condition. Load capacitance determines exactly how high
the output voltage will rise in response to these conditions. After
200 ms the converter will automatically restart.
Over-Temperature Shutdown: A temperature sensor on
the converter senses the average temperature of the module.
The thermal shutdown circuit is designed to turn the converter
off when the temperature at the sensed location reaches the
Over-Temperature Shutdown value. It will allow the converter
to turn on again when the temperature of the sensed location
falls by the amount of the Over-Temperature Shutdown Restart
Hysteresis value.
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 23
Technical
Specification
IQ18xxxHPXxxx
Application Section
APPLICATION CONSIDERATIONS
Input System Instability: This condition can occur because
any dc-dc converter appears incrementally as a negative
resistance load. A detailed application note titled “Input System
Instability” is available on the SynQor website which provides
an understanding of why this instability arises, and shows the
preferred solution for correcting it.
Application Circuits: Figure C provides a typical circuit diagram
which details the input filtering and voltage trimming.
Vin(+)
Vin
External
Input
Filter
Electrolytic
Capacitor
Vout(+)
Vsense(+)
ON/OFF
Trim
Vsense(_)
Vin(_)
Rtrim-up
or
Rtrim-down
Cload
Iload
Vout(_)
Figure C: Typical application circuit (negative logic unit, permanently enabled).
Input Filtering and External Capacitance: Figure D provides
a diagram showing the internal input filter components. This filter
dramatically reduces input terminal ripple current, which otherwise
could exceed the rating of an external electrolytic input capacitor.
The recommended external input capacitance is specified in the
Input Characteristics section on the Electrical Characteristics
page. More detailed information is available in the application note
titled “EMI Characteristics” on the SynQor website.
L
Vin(+)
C
Vin(_)
Figure D: Internal Input Filter Diagram (component values listed on the specifications page).
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 24
Technical
Specification
IQ18xxxHPXxxx
Application Section
Startup Inhibit Period: The Startup Inhibit Period ensures that
the converter will remain off for approximately 200 ms when it is
shut down for any reason. When an output short is present, this
generates a 5 Hz “hiccup mode,” which prevents the converter
from overheating. In all, there are seven ways that the converter
can be shut down, initiating a Startup Inhibit Period:
• InputUnder-VoltageLockout
When the ON/OFF pin goes high after t2, the Startup Inhibit
Period has elapsed, and the output turns on within the typical
Turn-On Time.
Thermal Considerations: The maximum operating base-plate
temperature, TB, is 100 ºC. As long as the user’s thermal system
keeps TB < 100 ºC, the converter can deliver its full rated power.
A power derating curve can be calculated for any heatsink that is
attached to the base-plate of the converter. It is only necessary
to determine the thermal resistance, RTHBA, of the chosen heatsink
between the base-plate and the ambient air for a given airflow
rate. This information is usually available from the heatsink
vendor. The following formula can the be used to determine the
maximum power the converter can dissipate for a given thermal
condition if its base-plate is to be no higher than 100 ºC.
• InputOver-VoltageLockout
• OutputOver-VoltageProtection
• OverTemperatureShutdown
• CurrentLimit
• ShortCircuitProtection
• TurnedoffbytheON/OFFinput
Figure E shows three turn-on scenarios, where a Startup Inhibit
Period is initiated at t0, t1, and t2:
Before time t0, when the input voltage is below the UVL threshold,
the unit is disabled by the Input Under-Voltage Lockout feature.
When the input voltage rises above the UVL threshold, the Input
Under-Voltage Lockout is released, and a Startup Inhibit Period is
initiated. At the end of this delay, the ON/OFF pin is evaluated,
and since it is active, the unit turns on.
At time t1, the unit is disabled by the ON/OFF pin, and it cannot
be enabled again until the Startup Inhibit Period has elapsed.
max
Pdiss =
100 ºC - TA
RTHBA
This value of power dissipation can then be used in conjunction
with the data shown in Figure 2 to determine the maximum load
current (and power) that the converter can deliver in the given
thermal condition.
For convenience, power derating curves for an encased converter
without a heatsink and with a typical heatsink are provided for
each output voltage.
Vin
Under-Voltage
Lockout TurnOn Threshold
ON/OFF
(neg logic)
ON
OFF ON
OFF
ON
10ms
Vout
(typical turn on time)
230ms
(typical start-up
inhibit period)
t1
t0
200ms
200ms
t2
t
Figure E: Startup Inhibit Period (turn-on time not to scale)
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 25
Technical
Specification
IQ18xxxHPXxxx
Standards & Qualification Testing
Parameter
Notes & Conditions
STANDARDS COMPLIANCE
UL 60950-1/R:2011-12
Basic Insulation
CAN/CSA-C22.2 No. 60950-1/A1:2011
EN 60950-1/A12:2011
Certified by TUV
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new
releases or download from the SynQor website.
Parameter
# Units Test Conditions
QUALIFICATION TESTING
Life Test
32
95% rated Vin and load, units at derating point, 1000 hours
Vibration
5
10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis
Mechanical Shock
5
100g minimum, 2 drops in x, y, and z axis
Temperature Cycling
10
-40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles
Power/Thermal Cycling
5
Toperating = min to max, Vin = min to max, full load, 100 cycles
Design Marginality
5
Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load
Humidity
5
85 °C, 95% RH, 1000 hours, continuous Vin applied except 5 min/day
Solderability
15 pins
Altitude
2
MIL-STD-883, method 2003
70,000 feet (21 km), see Note
Note: A conductive cooling design is generally needed for high altitude applications because of naturally poor convective cooling at rare atmospheres.
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 26
Technical
Specification
IQ18xxxHPXxxx
Standard Mechanical Diagram
2.486 ±.020 [ 63,14 0,5 ]
2.00 [ 50,8 ]
1.400 [ 35,56]
1.000 [ 25,4]
.700 [ 17,78]
.400 [ 10,16]
.512 +.002
-.005
+0,05
[ 13-0,12 ]
OVERALL
HEIGHT
.243 ±.020
[ 6,17± 0,5 ]
8
7
6
5
.163
[ 4,14]
4
.243 ±.020
[ 6,17 ±0,5 ]
2.386 ±.020
[ 60,6 ±0,5 ]
TOP VIEW
1.90
[ 48,3]
SIDE VIEW
1.90
[ 48,3]
.233 ±.020
[ 5,92 ±0,5 ]
1
2
3
.543 ±.020 [ 13,79±0,5 ]
.400 [ 10,16]
1.400 [ 35,56 ]
THRU HOLE
M3 (SEE NOTE 8)
STANDOFFS (4)
NOTES
PIN DESIGNATIONS
1)
2)
Applied torque per screw should not exceed 6in-lb. (0.7 Nm).
3)
Pins 1-3, 5-7 are 0.040” (1.02mm) diameter, with 0.080”
(2.03mm) diameter standoff shoulders.
Pins 4 and 8 are 0.080” (2.03 mm) dia. with 0.125” (3.18 mm) dia.
standoff shoulders
All Pins: Material: Copper Alloy
Finish: Matte Tin over Nickel plate
Undimensioned Components are shown for visual reference only
Weight: 4.7 oz (134 g)
Threaded or Non-Threaded options available
All dimensions in inches (mm) Tolerances:
x.xx +/-0.02 in. (x.x +/-0.5mm)
x.xxx +/-0.010 in. (x.xx +/-0.25mm)
4)
5)
6)
7)
8)
9)
Baseplate flatness tolerance is 0.004" (.10 mm) TIR for surface.
Product # IQ18xxxHPXxxx
.027 +.007
-.010
+0,17
[ 0,69 -0,25 ]
BOTTOMSIDE CLEARANCE
Phone 1-888-567-9596
www.synqor.com
Pin
Name
Function
1
Vin(+)
2
ON/OFF
Positive input voltage
TTL input to turn converter on and off,
referenced to Vin(–), with internal pull up.
Negative input voltage
Negative output voltage
Negative remote sense(see note 1)
Output voltage trim (see note 2)
Positive remote sense (see note 3)
Positive output voltage
3
Vin(–)
4
Vout(–)
5
SENSE(–)
6
TRIM
7
SENSE(+)
8
Vout(+)
Notes:
SENSE(–) should be connected to Vout(–) either remotely
1)
or at the converter.
2)
Leave TRIM pin open for nominal output voltage.
SENSE(+) should be connected to Vout(+) either remotely
3)
or at the converter.
Doc.# 005-0005305 Rev. E
11/22/13
Page 27
Technical
Specification
IQ18xxxHPXxxx
Flanged Mechanical Diagram
3.15
[80 ]
2.486 .020
[63.14
0.5]
USE W/ 4-40 OR
M3 SCREW (6x)
RECOM. TORQUE
3 in.lb
.13[3.3]
.18
[4.6 ]
.500
.025
[12.7 0.63]
OVERALL
HEIGHT
4
7
[35.56 ]
1.000
[25.4 ]
.700
[17.78 ]
.400
[10.16 ]
8
BOT VIEW
TOP VIEW
1.61
[40.9 ]
2.386
[60.6
1.87
[47.4 ]
.96
[24.4 ]
6
5
1.400
1.90
[48.3 ]
.020
0.5]
.31
[7.9 ]
1
2
3
.027
[0.69
.020
0.5]
2.175
[55.25
.775 .020
[19.69
0.5]
.020
0.5]
.13
[3.2 ]
1.400
[35.56 ]
1
.400
[10.16 ]
.875 .020
[22.23
0.5]
PIN DESIGNATIONS
NOTES
1)
2)
3)
4)
5)
6)
7)
8)
Applied torque per screw should not exceed 5in-lb.
(3in-lb recommended).
Pin
Name
Function
1
Vin(+)
2
ON/OFF
Positive input voltage
TTL input to turn converter on and off,
referenced to Vin(–), with internal pull up.
Negative input voltage
Negative output voltage
Negative remote sense(see note 1)
Output voltage trim (see note 2)
Positive remote sense (see note 3)
Positive output voltage
Baseplate flatness tolerance is 0.01" (.25 mm) TIR for surface.
Pins 1-3, 5-7 are 0.040” (1.02mm) diameter, with 0.080”
(2.03mm) diameter standoff shoulders.
Pins 4 and 8 are 0.080” (2.03 mm) dia. with 0.125” (3.18 mm) dia.
standoff shoulders
All Pins: Material: Copper Alloy
Finish: Matte Tin over Nickel plate
Undimensioned Components are shown for visual reference only
Weight: 4.9 oz (140g)
All dimensions in inches (mm) Tolerances:
x.xx +/-0.02 in. (x.x +/-0.5mm)
x.xxx +/-0.010 in. (x.xx +/-0.25mm)
Product # IQ18xxxHPXxxx
Phone 1-888-567-9596
3
Vin(–)
4
Vout(–)
5
SENSE(–)
6
TRIM
7
SENSE(+)
8
Vout(+)
Notes:
SENSE(–) should be connected to Vout(–) either remotely
1)
or at the converter.
2)
Leave TRIM pin open for nominal output voltage.
SENSE(+) should be connected to Vout(+) either remotely
3)
or at the converter.
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 28
Technical
Specification
IQ18xxxHPXxxx
PART NUMBERING SYSTEM
ORDERING INFORMATION
The part numbering system for SynQor’s dc-dc converters follows the format
shown in the example below.
The tables below show the valid model numbers and ordering options for
converters in this product family. When ordering SynQor converters, please
ensure that you use the complete 15 character part number consisting of
the 12 character base part number and the additional characters for options.
InQor units are only available with 6/6 RoHS compliance indicated by "-G".
IQ 1 8 0 1 8 H P C 6 0 N R S - G
Options
(see
Ordering Information)
Output Current
Thermal Design
Performance Level
Package Size
Output Voltage
Input Voltage
Product Family
The first 12 characters comprise the base part number and the last 3
characters indicate available options. The “-G” suffix indicates 6/6 RoHS
compliance.
Input
Voltage
9-36V
9-36V
9-36V
9-36V
9-36V
9-36V
9-36V
9-36V
9-36V
Model Number
6/6 RoHS
IQ18018HPw60NRS
IQ18033HPw50NRS
IQ18050HPw36NRS
IQ18120HPw15NRS
IQ18150HPw12NRS
IQ18240HPw7FNRS
IQ18280HPw6FNRS
IQ18400HPw4FNRS
IQ18480HPw3HNRS
Output
Voltage
1.8V
3.3V
5V
12V
15V
24V
28V
40V
48V
Max Output
Current
60A
50A
36A
15A
12A
7.5A
6.5A
4.5A
3.7A
The following options must be included in place of the w x y z spaces in the
model numbers listed above.
Options Description: w x y z
Thermal Design
Enable Logic Pin Style
C - Encased with
Threaded Baseplate
D - Encased with NonThreaded Baseplate
V - Encased with Flanged
Baseplate
Application Notes
A variety of application notes and technical white papers can be downloaded
in pdf format from our website.
N - Negative
Feature Set
R - 0.180"
S - Standard
RoHS Compliance: The EU led RoHS (Restriction of Hazardous
Substances) Directive bans the use of Lead, Cadmium, Hexavalent
Chromium, Mercury, Polybrominated Biphenyls (PBB), and Polybrominated
Diphenyl Ether (PBDE) in Electrical and Electronic Equipment. This SynQor
product is 6/6 RoHS compliant. For more information please refer to
SynQor’s RoHS addendum available at our RoHS Compliance / Lead
Free Initiative web page or e-mail us at [email protected].
Not all combinations make valid part numbers, please contact SynQor for
availability.
PATENTS
SynQor holds the following U.S. patents, one or more of which apply to
each product listed in this document. Additional patent applications may
be pending or filed in the future.
Contact SynQor for further information and to order:
Phone:
Toll Free:
Fax:
E-mail:
Web:
Address:
Product # IQ18xxxHPXxxx
978-849-0600
888-567-9596
978-849-0602
[email protected]
www.synqor.com
155 Swanson Road
Boxborough, MA 01719
USA
Phone 1-888-567-9596
5,999,417
6,222,742
6,545,890
6,577,109
6,594,159
6,731,520
6,894,468
6,896,526
6,927,987
7,050,309
7,072,190
7,085,146
7,119,524
7,269,034
7,272,021
7,272,023
7,558,083
7,564,702
7,765,687
7,787,261
8,023,290
8,149,597
8,493,751
Warranty
SynQor offers a two (2) year limited warranty. Complete warranty
information is listed on our website or is available upon request from
SynQor.
Information furnished by SynQor is believed to be accurate and reliable.
However, no responsibility is assumed by SynQor for its use, nor for any
infringements of patents or other rights of third parties which may result
from its use. No license is granted by implication or otherwise under any
patent or patent rights of SynQor.
www.synqor.com
Doc.# 005-0005305 Rev. E
11/22/13
Page 29