Technical Specification IQ1BxxxHPXxxx 66-160 V 170 V 3.3-48 V 255 W Continuous Input Transient Input Outputs Max Power 3000 Vdc Half-brick REINFORCED INSULATION DC-DC Converter The InQor Half-brick converter series is composed of nextgeneration, board-mountable, isolated (REINFORCED), fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications. 0NRS-G 3HPC6 ER 3 0 B 1 IQ ERT 60 A C CONV DC-D V UT @ V 3.3 O 66-160 IN Operational Features • • • • • High efficiency, up to 91 % at full rated load current Delivers full power with minimal derating Operating input voltage range: 66-160 V Fixed frequency switching provides predictable EMI No minimum load requirement Protection Features Mechanical Features • • • • Industry standard Half-brick pin-out Size: 2.386" x 2.486" x 0.512" (60.60 x 63.14 x 13.00 mm) Total weight: 4.7 oz (133 g) Flanged baseplate version available • • • • • • Input under-voltage lockout Input over-voltage shutdown Output current limit and short circuit protection Active backdrive current limit Output over-voltage protection Thermal shutdown Control Features • On/Off control referenced to input side • Remote sense for improved output voltage control • Wide output voltage trim range Safety Features Reinforced Insulation • UL 60950-1/R:2011-12 • CAN/CSA-C22.2 No. 60950-1/A1:2011 • EN 60950-1/A2:2013 • CE Marked • RoHS compliant (see last page) Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 CONTENTS Page No. Family Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 3.3Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . . 4 5.0Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . . 6 12Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . . 8 15Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 10 24Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 12 28Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 14 40Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 16 48Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 18 Application Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Standards & Qualification Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Standard Mechanical Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Flanged Mechanical Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 1 Technical Specification IQ1BxxxHPXxxx IQ1B-HP FAMILY ELECTRICAL CHARACTERISTICS (all output voltages) Ta = 25 °C, airflow rate = 300 LFM, Vin = 110 Vdc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. ABSOLUTE MAXIMUM RATINGS Input Voltage Non-Operating -0.5 175 Operating 160 Operating Transient 170 Insulation Voltage Input to Output 3000 Input to Baseplate 3000 Output to Baseplate 3000 Operating Temperature -40 100 Storage Temperature -45 125 Voltage at ON/OFF input pin -2 18 INPUT CHARACTERISTICS Operating Input Voltage Range 66 110 160 Input Under-Voltage Lockout Turn-On Voltage Threshold 62.0 64.0 66.0 Turn-Off Voltage Threshold 59 61 63 Lockout Voltage Hysteresis 3.0 Input Over-Voltage Shutdown Recommended External Input Capacitance 100 Input Filter Component Values (L\C) 1.1\1.8 DYNAMIC CHARACTERISTICS Turn-On Transient Turn-On Time 10 Start-Up Inhibit Time 180 200 220 Output Voltage Overshoot 0 ISOLATION CHARACTERISTICS Isolation Voltage (dielectric strength) Isolation Resistance 100 Isolation Capacitance (input to output) 1000 TEMPERATURE LIMITS FOR POWER DERATING CURVES Semiconductor Junction Temperature 125 PCB Temperature 125 Transformer Temperature 125 Maximum Baseplate Temperature, Tb 100 FEATURE CHARACTERISTICS Switching Frequency 255 275 295 ON/OFF Control Off-State Voltage 2.4 18 On-State Voltage -2 0.8 ON/OFF Control Pull-Up Voltage 5 Pull-Up Resistance 50 Over-Temperature Shutdown OTP Trip Point 125 Over-Temperature Shutdown Restart Hysteresis 10 RELIABILITY CHARACTERISTICS Calculated MTBF (Telcordia) TR-NWT-000332 1.44 Calculated MTBF (MIL-217) MIL-HDBK-217F 1.20 Field Demonstrated MTBF Note 1: Higher values of isolation capacitance can be added externally to the module. Note 2: See “Input System Instability” in the Application Considerations section. Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 www.synqor.com Units Notes & Conditions V V V Vdc Vdc Vdc °C °C V Continuous Continuous 100 ms Baseplate temperature V V V V V µF µH\µF ms ms % Not Available Typical ESR 0.1-0.2 Ω; see Note 2 Internal values; see Figure D Full load, Vout = 90 % nom. (from enable) Figure E Maximum Output Capacitance See Absolute Maximum Ratings MΩ pF See Note 1 °C °C °C °C Package rated to 150 °C UL rated max operating temp 130 °C kHz Insulation stage switching freq. is half this V Application notes Figures A & B V kΩ °C °C Average PCB Temperature 106 Hrs. Tb = 70 °C 106 Hrs. Tb = 70 °C 106 Hrs. See our website for details Doc.# 005-0005023 Rev. J 04/13/15 Page 2 Technical Specification IQ1BxxxHPXxxx Family Figures (all output voltages) 120 Typical Current Limit Inception Point Nominal Vout Output Voltage (%) 100 80 Current Limit Shutdown Voltage 60 40 Vin min Vin nom 20 Vin max 0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Load Current (%) Common Figure 1: Startup Waveform (typical), input voltage pre-applied, ON/ OFF Pin on Ch 2. Common Figure 2: Output I-V Characteristics (output voltage vs. load current) showing typical current limit curves and converter shutdown points. 100,000.0 3.3 V 10,000 5V 12 V 15 V Trim Resistance (kOhms) Trim Resistance (kOhms) 100,000 1,000 100 10 0 1 2 3 4 5 6 7 8 9 28 V 40 V 48 V 10,000.0 1,000.0 100.0 10 24 V 0 1 2 3 4 5 6 7 8 9 10 Increase in Vout (%) Increase in Vout (%) Common Figure 3: Trim-Up Graph for 3.3 to 12V outputs. Common Figure 3: Trim-Up Graph for 15 to 48V outputs. 10,000.0 Trim Resistance (kOhms) All voltages 1,000.0 100.0 10.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Decrease in Vout (%) Common Figure 5: Trim-Down Graph for all outputs. Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 3 Input:66-160 V Output:3.3 V Current:60 A Part No.:IQ1B033HPx60 Technical Specification IQ1B033HPx60 ELECTRICAL CHARACTERISTICS (3.3 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 110 Vdc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current (enabled) Disabled Input Current 4.4 A 50 60 mA 3 5 mA Response to Input Transient 0.11 V Input Terminal Ripple Current 130 mA Recommended Input Fuse 8 A 3.300 3.333 V ±0.1 ±0.3 % ±0.1 Vin min; trim up; in current limit See Figure 6 RMS Fast acting fuse recommended; see Note 3 OUTPUT CHARACTERISTICS Output Voltage Set Point 3.267 Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range ±0.3 % -50 50 mV 3.217 3.383 V 200 400 mV Full load 30 60 mV Full load 60 A Subject to thermal derating 78.0 A Output voltage 10 % Low Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak RMS Operating Output Current Range 0 Output DC Current Limit Inception 66.0 Output DC Current Limit Shutdown Voltage 72.0 1.5 V Back-Drive Current Limit while Enabled 2 A Negative current drawn into output pins Back-Drive Current Limit while Disabled 5 mA Negative current drawn into output pins µF Vout nominal at full load (resistive load) Maximum Output Capacitance 10,000 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 250 mV 50 % to 75 % to 50 % Iout max; see Figure 5 Settling Time 200 µs To within 1 % Vout nom; see Figure 5 10 % Across Pins 8 & 4; Common Figures 3-5 10 % Across Pins 8 & 4 4.2 V Over full temp range % See Figure 1 for efficiency curve Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 3.9 4.0 EFFICIENCY 100 % Load 89 50 % Load 91 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 3: Safety certification requires the use of a fuse rated at or below this value. Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 4 Input:66-160 V Output:3.3 V Current:60 A Part No.:IQ1B033HPx60 Technical Specification 100 35 95 30 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 20 15 10 66Vin 66Vin 110Vin 65 60 25 5 110Vin 160Vin 0 5 10 15 20 25 30 35 40 45 50 160Vin 55 0 60 0 5 10 15 20 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 °C. 30 35 40 45 50 55 60 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 °C. 70 70 60 60 50 50 40 Iout (A) Iout (A) 25 Load Current (A) Load Current (A) 30 20 40 30 20 400 LFM (2.0 m/s) 10 300 LFM (1.5 m/s) 10 0 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 50 60 70 80 90 100 110 0 Baseplate Temperature (°C) 25 40 55 70 85 Ambient Air Temperature (°C) Figure 3: Maximum load current vs. baseplate temperature when conductively cooled. Note: The system design must provide a suitable thermal path that maintains the baseplate temperature below 100 °C. Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50 % -75 % -50 % of Iout(max); dI/dt = 0.1 A/µs. Load cap: 15 µF tantalum cap and 1 µF ceramic cap. Ch 1: Vout, Ch 2: Iout (25 A/div). Figure 6: Output voltage response to step-change in input voltage (1000 V/ms), at Max. load current.Load cap: 15 µF tantalum cap and 1 µF ceramic cap. Ch 1: Vout, Ch 2: Vin. Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 5 Input:66-160 V Output:5 V Current:48 A Part No.:IQ1B050HPx48 Technical Specification IQ1B050HPx48 ELECTRICAL CHARACTERISTICS (5.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 110 Vdc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current (enabled) Disabled Input Current 5.5 A 40 50 mA 2 5 mA Response to Input Transient 0.16 V Input Terminal Ripple Current 170 mA Recommended Input Fuse 8 A 5.000 5.050 V ±0.1 ±0.3 % ±0.1 Vin min; trim up; in current limit See Figure 6 RMS Fast acting fuse recommended; see Note 3 OUTPUT CHARACTERISTICS Output Voltage Set Point 4.950 Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range ±0.3 % -75 75 mV 4.875 5.125 V 180 360 mV Full load 30 60 mV Full load 48 A Subject to thermal derating 62.4 A Output voltage 10 % Low Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak RMS Operating Output Current Range 0 Output DC Current Limit Inception 52.8 Output DC Current Limit Shutdown Voltage 57.6 2.2 V Back-Drive Current Limit while Enabled 1 A Negative current drawn into output pins Back-Drive Current Limit while Disabled 1 mA Negative current drawn into output pins µF Vout nominal at full load (resistive load) Maximum Output Capacitance 8,000 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 350 mV 50 % to 75 % to 50 % Iout max; see Figure 5 Settling Time 200 µs To within 1 % Vout nom; see Figure 5 10 % Across Pins 8 & 4; Common Figures 3-5; see Note 2 10 % Across Pins 8 & 4 6.4 V Over full temp range % See Figure 1 for efficiency curve Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 5.9 6.1 EFFICIENCY 100 % Load 88 50 % Load 90 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 2: Trim-up range is limited below 10 % at lower line and full load. Contact SynQor applications support for more detail (email: support@synqor. com) Note 3: Safety certification requires the use of a fuse rated at or below this value. Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 6 Input:66-160 V Output:5 V Current:48 A Part No.:IQ1B050HPx48 Technical Specification 100 45 95 40 35 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 60 110Vin 4 8 12 16 20 24 28 32 36 40 20 15 66Vin 110Vin 5 160Vin 0 25 10 66Vin 65 30 44 0 48 160Vin 0 4 8 12 16 20 24 28 32 36 40 44 48 Load Current (A) Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 °C. Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 °C. 54 60 48 50 36 30 30 Iout (A) Iout (A) 42 40 20 24 18 10 400 LFM (2.0 m/s) 12 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 6 0 50 60 70 80 90 100 110 0 Baseplate Temperature (°C) 100 LFM (0.5 m/s) 25 40 55 70 85 Ambient Air Temperature (°C) Figure 3: Maximum load current vs. baseplate temperature when conductively cooled. Note: The system design must provide a suitable thermal path that maintains the baseplate temperature below 100 °C. Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50 % -75 % -50 % of Iout(max); dI/dt = 0.1 A/µs. Load cap: 15 µF tantalum cap and 1 µF ceramic cap. Ch 1: Vout, Ch 2: Iout (10 A/div). Figure 6: Output voltage response to step-change in input voltage (1000 V/ms), at Max. load current.Load cap: 15 µF tantalum cap and 1 µF ceramic cap. Ch 1: Vout, Ch 2: Vin. Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 7 Input:66-160 V Output:12 V Current:21 A Part No.:IQ1B120HPx21 Technical Specification IQ1B120HPx21 ELECTRICAL CHARACTERISTICS (12.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 110 Vdc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current (enabled) Disabled Input Current 5.5 A 50 60 mA 3 5 mA Response to Input Transient 0.2 V Input Terminal Ripple Current 170 mA Recommended Input Fuse 8 A 12.00 12.12 V ±0.1 ±0.3 % ±0.1 Vin min; trim up; in current limit See Figure 6 RMS Fast acting fuse recommended; see Note 3 OUTPUT CHARACTERISTICS Output Voltage Set Point 11.88 Output Voltage Regulation Over Line Over Load ±0.3 % Over Temperature -180 180 mV Total Output Voltage Range 11.70 12.30 V 120 240 mV Full load 20 40 mV Full load 21 A Subject to thermal derating 27.3 A Output voltage 10 % Low Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak RMS Operating Output Current Range 0 Output DC Current Limit Inception 23.1 25.2 Output DC Current Limit Shutdown Voltage 6.6 V Back-Drive Current Limit while Enabled 0.5 A Negative current drawn into output pins Back-Drive Current Limit while Disabled 1 mA Negative current drawn into output pins µF Vout nominal at full load (resistive load) Maximum Output Capacitance 1,500 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 500 mV 50 % to 75 % to 50 % Iout max; see Figure 5 Settling Time 100 µs To within 1 % Vout nom; see Figure 5 10 % Across Pins 8 & 4; Common Figures 3-5; see Note 2 10 % Across Pins 8 & 4 15.2 V Over full temp range % See Figure 1 for efficiency curve Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 14.0 14.6 EFFICIENCY 100 % Load 92 50 % Load 93 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 2: Trim-up range is limited below 10 % at lower line and full load. Contact SynQor applications support for more detail (email: support@synqor. com) Note 3: Safety certification requires the use of a fuse rated at or below this value. Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 8 Input:66-160 V Output:12 V Current:21 A Part No.:IQ1B120HPx21 Technical Specification 100 30 95 25 Power Dissipation (W) Efficiency (%) 90 85 80 ` 75 70 15 10 66Vin 66Vin 160Vin 0 3 6 9 12 15 110Vin 5 110Vin 65 60 20 0 18 21 160Vin 0 3 6 Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 °C. 9 12 15 18 21 Load Current (A) Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 °C. 24 25 21 18 15 15 Iout (A) Iout (A) 20 10 12 9 5 400 LFM (2.0 m/s) 6 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 3 0 50 60 70 80 90 100 110 0 Baseplate Temperature (°C) 100 LFM (0.5 m/s) 25 40 55 70 85 Ambient Air Temperature (°C) Figure 3: Maximum load current vs. baseplate temperature when conductively cooled. Note: The system design must provide a suitable thermal path that maintains the baseplate temperature below 100 °C. Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50 % -75 % -50 % of Iout(max); dI/dt = 0.1 A/µs. Load cap: 15 µF tantalum cap and 1 µF ceramic cap. Ch 1: Vout, Ch 2: Iout (5 A/div). Figure 6: Output voltage response to step-change in input voltage (1000 V/ms), at Max. load current.Load cap: 15 µF tantalum cap and 1 µF ceramic cap. Ch 1: Vout, Ch 2: Vin. Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 9 Input:66-160 V Output:15 V Current:17 A Part No.:IQ1B150HPx17 Technical Specification IQ1B150HPx17 ELECTRICAL CHARACTERISTICS (15.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 110 Vdc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current (enabled) Disabled Input Current 5.6 A 50 60 mA 3 5 mA Response to Input Transient 0.2 V Input Terminal Ripple Current 180 mA Recommended Input Fuse 8 A 15.00 15.15 V ±0.1 ±0.3 % ±0.1 Vin min; trim up; in current limit See Figure 6 RMS Fast acting fuse recommended; see Note 3 OUTPUT CHARACTERISTICS Output Voltage Set Point 14.85 Output Voltage Regulation Over Line Over Load ±0.3 % Over Temperature -225 225 mV Total Output Voltage Range 14.62 15.38 V 160 320 mV Full load 20 40 mV Full load 17 A Subject to thermal derating 22.1 A Output voltage 10 % Low Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak RMS Operating Output Current Range 0 Output DC Current Limit Inception 18.7 Output DC Current Limit Shutdown Voltage 20.4 8 V Back-Drive Current Limit while Enabled 0.5 A Negative current drawn into output pins Back-Drive Current Limit while Disabled 1 mA Negative current drawn into output pins µF Vout nominal at full load (resistive load) Maximum Output Capacitance 1,000 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 650 mV 50 % to 75 % to 50 % Iout max; see Figure 5 Settling Time 100 µs To within 1 % Vout nom; see Figure 5 10 % Across Pins 8 & 4; Common Figures 3-5 10 % Across Pins 8 & 4 19.1 V Over full temp range % See Figure 1 for efficiency curve Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 17.6 18.3 EFFICIENCY 100 % Load 91 50 % Load 93 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 3: Safety certification requires the use of a fuse rated at or below this value. Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 10 Input:66-160 V Output:15 V Current:17 A Part No.:IQ1B150HPx17 Technical Specification 100 35 95 30 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 66Vin 65 160Vin 60 25 20 15 10 110Vin 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 66Vin 110Vin 5 16 0 17 160Vin 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Load Current (A) Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 °C. Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 °C. 21 18 16 18 14 15 10 Iout (A) Iout (A) 12 8 6 4 12 9 6 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 2 3 0 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 50 60 70 80 90 100 110 0 Baseplate Temperature (°C) 25 40 55 70 85 Ambient Air Temperature (°C) Figure 3: Maximum load current vs. baseplate temperature when conductively cooled. Note: The system design must provide a suitable thermal path that maintains the baseplate temperature below 100 °C. Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50 % -75 % -50 % of Iout(max); dI/dt = 0.1 A/µs. Load cap: 15 µF tantalum cap and 1 µF ceramic cap. Ch 1: Vout, Ch 2: Iout (2.5 A/div). Figure 6: Output voltage response to step-change in input voltage (1000 V/ms), at Max. load current.Load cap: 15 µF tantalum cap and 1 µF ceramic cap. Ch 1: Vout, Ch 2: Vin. Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 11 Input:66-160 V Output:24 V Current:10 A Part No.:IQ1B240HPx10 Technical Specification IQ1B240HPx10 ELECTRICAL CHARACTERISTICS (24.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 110 Vdc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current (enabled) Disabled Input Current 5.3 A 50 60 mA 3 5 mA Response to Input Transient 0.5 V Input Terminal Ripple Current 170 mA Recommended Input Fuse 8 A 24.00 24.24 V ±0.1 ±0.3 % ±0.1 Vin min; trim up; in current limit See Figure 6 RMS Fast acting fuse recommended; see Note 3 OUTPUT CHARACTERISTICS Output Voltage Set Point 23.76 Output Voltage Regulation Over Line Over Load ±0.3 % Over Temperature -360 360 mV Total Output Voltage Range 23.40 24.60 V 120 240 mV Full load 40 80 mV Full load 10 A Subject to thermal derating 13.0 A Output voltage 10 % Low Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak RMS Operating Output Current Range 0 Output DC Current Limit Inception 11.0 12.0 Output DC Current Limit Shutdown Voltage 12 V Back-Drive Current Limit while Enabled 0.2 A Negative current drawn into output pins Back-Drive Current Limit while Disabled 1 mA Negative current drawn into output pins µF Vout nominal at full load (resistive load) Maximum Output Capacitance 400 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 1200 mV 50 % to 75 % to 50 % Iout max; see Figure 5 Settling Time 100 µs To within 1 % Vout nom; see Figure 5 10 % Across Pins 8 & 4; Common Figures 3-5 10 % Across Pins 8 & 4 30.5 V Over full temp range % See Figure 1 for efficiency curve Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 28.1 29.3 EFFICIENCY 100 % Load 90 50 % Load 92 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 3: Safety certification requires the use of a fuse rated at or below this value. Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 12 Input:66-160 V Output:24 V Current:10 A Part No.:IQ1B240HPx10 Technical Specification 100 35 95 30 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 66Vin 65 160Vin 60 110Vin 0 1 2 3 4 5 6 7 8 25 20 15 10 66Vin 110Vin 5 9 0 10 160Vin 0 1 2 3 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 °C. 5 6 7 8 9 10 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 °C. 12 12 10 10 8 8 Iout (A) Iout (A) 4 Load Current (A) Load Current (A) 6 4 6 4 400 LFM (2.0 m/s) 2 300 LFM (1.5 m/s) 2 200 LFM (1.0 m/s) 0 100 LFM (0.5 m/s) 50 60 70 80 90 100 110 0 Baseplate Temperature (°C) 25 40 55 70 85 Ambient Air Temperature (°C) Figure 3: Maximum load current vs. baseplate temperature when conductively cooled. Note: The system design must provide a suitable thermal path that maintains the baseplate temperature below 100 °C. Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50 % -75 % -50 % of Iout(max); dI/dt = 0.1 A/µs. Load cap: 1 µF ceramic cap. Ch 1: Vout, Ch 2: Iout (2.5 A/div). Figure 6: Output voltage response to step-change in input voltage (1000 V/ms), at Max. load current. Load cap: 1 µF ceramic cap. Ch 1: Vout, Ch 2: Vin. Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 13 Input:66-160 V Output:28 V Current:9 A Part No.:IQ1B280HPx09 Technical Specification IQ1B280HPx09 ELECTRICAL CHARACTERISTICS (28.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 110 Vdc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current (enabled) Disabled Input Current 5.6 A 40 50 mA 3 5 mA Response to Input Transient 0.5 V Input Terminal Ripple Current 200 mA Recommended Input Fuse 8 A 28.00 28.28 V ±0.1 ±0.3 % ±0.1 Vin min; trim up; in current limit See Figure 6 RMS Fast acting fuse recommended; see Note 3 OUTPUT CHARACTERISTICS Output Voltage Set Point 27.72 Output Voltage Regulation Over Line Over Load ±0.3 % Over Temperature -420 420 mV Total Output Voltage Range 27.30 28.70 V 200 400 mV Full load 40 80 mV Full load 9 A Subject to thermal derating 11.7 A Output voltage 10 % Low Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak RMS Operating Output Current Range 0 Output DC Current Limit Inception 9.9 Output DC Current Limit Shutdown Voltage 10.8 13 V Back-Drive Current Limit while Enabled 0.25 A Negative current drawn into output pins Back-Drive Current Limit while Disabled 1 mA Negative current drawn into output pins µF Vout nominal at full load (resistive load) Maximum Output Capacitance 250 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 1500 mV 50 % to 75 % to 50 % Iout max; see Figure 5 Settling Time 100 µs To within 1 % Vout nom; see Figure 5 10 % Across Pins 8 & 4; Common Figures 3-5 10 % Across Pins 8 & 4 35.6 V Over full temp range % See Figure 1 for efficiency curve Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 32.8 34.2 EFFICIENCY 100 % Load 90 50 % Load 92 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 3: Safety certification requires the use of a fuse rated at or below this value. Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 14 Input:66-160 V Output:28 V Current:9 A Part No.:IQ1B280HPx09 100 40 95 35 90 30 Power Dissipation (W) Efficiency (%) Technical Specification 85 80 75 70 66Vin 65 160Vin 60 110Vin 0 1 2 3 4 5 6 7 25 20 15 10 66Vin 110Vin 5 8 0 9 160Vin 0 1 2 3 10 10 9 9 8 8 7 7 6 5 4 3 2 1 70 80 90 6 7 8 9 6 5 4 3 400 LFM (2.0 m/s) 2 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 1 0 60 5 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 °C. Iout (A) Iout (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 °C. 50 4 Load Current (A) Load Current (A) 100 110 0 Baseplate Temperature (°C) 100 LFM (0.5 m/s) 25 40 55 70 85 Ambient Air Temperature (°C) Figure 3: Maximum load current vs. baseplate temperature when conductively cooled. Note: The system design must provide a suitable thermal path that maintains the baseplate temperature below 100 °C. Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50 % -75 % -50 % of Iout(max); dI/dt = 0.1 A/µs. Load cap: 1 µF ceramic cap. Ch 1: Vout, Ch 2: Iout (2.5 A/div). Figure 6: Output voltage response to step-change in input voltage (1000 V/ms), at Max. load current. Load cap: 1 µF ceramic cap. Ch 1: Vout, Ch 2: Vin. Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 15 Input:66-160 V Output:40 V Current:6.3 A Part No.:IQ1B400HPx06 Technical Specification IQ1B400HPx06 ELECTRICAL CHARACTERISTICS (40.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 110 Vdc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units INPUT CHARACTERISTICS Maximum Input Current 5.6 No-Load Input Current (enabled) 50 60 Disabled Input Current 3 5 Response to Input Transient 0.8 Input Terminal Ripple Current 180 Recommended Input Fuse 8 OUTPUT CHARACTERISTICS Output Voltage Set Point 39.60 40.00 40.40 Output Voltage Regulation Over Line ±0.1 ±0.3 Over Load ±0.1 ±0.3 Over Temperature -600 600 Total Output Voltage Range 39.00 41.00 Output Voltage Ripple and Noise Peak-to-Peak 250 500 RMS 40 80 Operating Output Current Range 0 6.3 Output DC Current Limit Inception 6.9 7.6 8.2 Output DC Current Limit Shutdown Voltage 20 Back-Drive Current Limit while Enabled 0.2 Back-Drive Current Limit while Disabled 2 Maximum Output Capacitance 150 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 1900 Settling Time 100 Output Voltage Trim Range -20 10 Output Voltage Remote Sense Range 10 Output Over-Voltage Protection 46.8 48.8 50.8 EFFICIENCY 100 % Load 90 50 % Load 92 Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced applications support (e-mail: [email protected]) Note 3: Safety certification requires the use of a fuse rated at or below this value. Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 www.synqor.com A mA mA V mA A Notes & Conditions Vin min; trim up; in current limit See Figure 6 RMS Fast acting fuse recommended; see Note 3 V % % mV V mV mV A A V A mA µF mV µs % % V Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Full load Full load Subject to thermal derating Output voltage 10 % Low Negative current drawn into output pins Negative current drawn into output pins Vout nominal at full load (resistive load) 50 % to 75 % to 50 % Iout max; see Figure 5 To within 1 % Vout nom; see Figure 5 Across Pins 8 & 4; Common Figures 3-5 Across Pins 8 & 4 Over full temp range % See Figure 1 for efficiency curve % See Figure 1 for efficiency curve output voltage ripple and noise, consult SynQor Doc.# 005-0005023 Rev. J 04/13/15 Page 16 Input:66-160 V Output:40 V Current:6.3 A Part No.:IQ1B400HPx06 Technical Specification 100 35 95 30 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 66Vin 110Vin 65 60 25 20 15 10 66Vin 5 110Vin 160Vin 0.0 0.7 1.4 2.1 2.8 3.5 4.2 4.9 160Vin 5.6 0 6.3 0.0 0.7 1.4 2.1 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 °C. 3.5 4.2 4.9 5.6 6.3 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 °C. 7 7 6 6 5 5 4 Iout (A) Iout (A) 2.8 Load Current (A) Load Current (A) 3 2 4 3 2 400 LFM (2.0 m/s) 1 300 LFM (1.5 m/s) 1 0 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 50 60 70 80 90 100 110 0 Baseplate Temperature (°C) 25 40 55 70 85 Ambient Air Temperature (°C) Figure 3: Maximum load current vs. baseplate temperature when conductively cooled. Note: The system design must provide a suitable thermal path that maintains the baseplate temperature below 100 °C. Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50 % -75 % -50 % of Iout(max); dI/dt = 0.1 A/µs. Load cap: 1 µF ceramic cap. Ch 1: Vout, Ch 2: Iout (1 A/div). Figure 6: Output voltage response to step-change in input voltage (1000 V/ms), at Max. load current. Load cap: 1 µF ceramic cap. Ch 1: Vout, Ch 2: Vin. Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 17 Input:66-160 V Output:48 V Current:5.2 A Part No.:IQ1B480HPx5C Technical Specification IQ1B480HPx5C ELECTRICAL CHARACTERISTICS (48.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 110 Vdc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current (enabled) Disabled Input Current 5.6 A 50 60 mA 3 5 mA Response to Input Transient 0.8 V Input Terminal Ripple Current 180 mA Recommended Input Fuse 8 A 48.00 48.48 V ±0.1 ±0.3 % ±0.1 Vin min; trim up; in current limit See Figure 6 RMS Fast acting fuse recommended; see Note 3 OUTPUT CHARACTERISTICS Output Voltage Set Point 47.52 Output Voltage Regulation Over Line Over Load ±0.3 % Over Temperature -720 720 mV Total Output Voltage Range 46.80 49.20 V 280 mV Full load Full load Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak 140 RMS 30 Operating Output Current Range 0 Output DC Current Limit Inception 5.72 6.24 60 mV 5.2 A Subject to thermal derating 6.76 A Output voltage 10 % Low Output DC Current Limit Shutdown Voltage 25 V Back-Drive Current Limit while Enabled 0.2 A Negative current drawn into output pins Back-Drive Current Limit while Disabled 2 mA Negative current drawn into output pins µF Vout nominal at full load (resistive load) Maximum Output Capacitance 100 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 2800 mV 50 % to 75 % to 50 % Iout max; see Figure 5 Settling Time 100 µs To within 1 % Vout nom; see Figure 5 10 % Across Pins 8 & 4; Common Figures 3-5. 10 % Across Pins 8 & 4 61.0 V Over full temp range % See Figure 1 for efficiency curve Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 56.2 58.6 EFFICIENCY 100 % Load 90 50 % Load 92 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 3: Safety certification requires the use of a fuse rated at or below this value. Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 18 Input:66-160 V Output:48 V Current:5.2 A Part No.:IQ1B480HPx5C Technical Specification 100 35 95 30 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 20 15 10 66Vin 66Vin 110Vin 65 60 25 5 110Vin 160Vin 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 160Vin 4.8 0 5.2 0.0 0.4 0.8 1.2 1.6 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 °C. 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 °C. 6 6 5 5 4 4 Iout (A) Iout (A) 2.0 Load Current (A) Load Current (A) 3 2 3 2 400 LFM (2.0 m/s) 1 300 LFM (1.5 m/s) 1 200 LFM (1.0 m/s) 0 100 LFM (0.5 m/s) 50 60 70 80 90 100 110 0 Baseplate Temperature (°C) 25 40 55 70 85 Ambient Air Temperature (°C) Figure 3: Maximum load current vs. baseplate temperature when conductively cooled. Note: The system design must provide a suitable thermal path that maintains the baseplate temperature below 100 °C. Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50 % -75 % -50 % of Iout(max); dI/dt = 0.1 A/µs. Load cap: 1 µF ceramic cap. Ch 1: Vout, Ch 2: Iout (2 A/div). Figure 6: Output voltage response to step-change in input voltage (1000 V/ms), at Max. load current. Load cap: 1 µF ceramic cap. Ch 1: Vout, Ch 2: Vin. Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 19 Technical Specification IQ1BxxxHPXxxx Application Section BASIC OPERATION AND FEATURES This converter series uses a two-stage power topology. The first stage is a buck-converter that output voltage constant over variations in line, temperature. The second stage uses a transformer the functions of input/output isolation and voltage step-down to achieve the output voltage required. conversion keeps the load, and to provide step-up or 5V 50k ON/OFF Both the first stage and the second stage switch at a fixed frequency for predictable EMI performance. Rectification of the transformer’s output is accomplished with synchronous rectifiers. These devices, which are MOSFETs with a very low on-state resistance, dissipate far less energy than Schottky diodes. This is the primary reason that the converter has such high efficiency. These converters are offered totally encased to withstand harsh environments and thermally demanding applications. Dissipation throughout the converter is so low that it does not require a heatsink for operation in many applications; however, adding a heatsink provides improved thermal derating performance in demanding applications. This series of converters use the industry standard footprint and pin-out configuration. TTL 100pF Vin(-) Figure B: Internal ON/OFF pin circuitry REMOTE SENSE(+) (Pins 7 and 5): The SENSE(+) inputs correct for voltage drops along the conductors that connect the converter’s output pins to the load. Pin 7 should be connected to Vout(+) and Pin 5 should be connected to Vout(-) at the point on the load where regulation is desired. A remote connection at the load can adjust for a voltage drop only as large as that specified in this datasheet, that is [Vout(+) - Vout(-)] – [Vsense(+) - Vsense(-)] < CONTROL FEATURES Sense Range % x Vout REMOTE ON/OFF (Pin 2): The ON/OFF input, Pin 2, permits the user to control when the converter is on or off. This input is referenced to the return terminal of the input bus, Vin(-). The ON/OFF signal is active low (meaning that a low turns the converter on). Figure A details four possible circuits for driving the ON/OFF pin. Figure B is a detailed look of the internal ON/ OFF circuitry. ON/OFF ON/OFF Sense Range % = Trim-up Range % (usually 10 %) Pins 7 and 5 must be connected for proper regulation of the output voltage. If these connections are not made, the converter will deliver an output voltage that is slightly higher than its specified value. Note: the output over-voltage protection circuit senses the voltage across the output (pins 8 and 4) to determine when it should trigger, not the voltage across the converter’s sense leads (pins 7 and 5). Therefore, the resistive drop on the board should be small enough so that output OVP does not trigger, even during load transients. Vin(_) Vin(_) Remote Enable Circuit 50k Negative Logic (Permanently Enabled) 5V ON/OFF TTL/ CMOS ON/OFF Vin(_) Vin(_ ) Open Collector Enable Circuit Direct Logic Drive Figure A: Various circuits for driving the ON/OFF pin. Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 20 Technical Specification IQ1BxxxHPXxxx Application Section OUTPUT VOLTAGE TRIM (Pin 6): The TRIM input permits the user to adjust the output voltage across the sense leads up or down according to the trim range specifications. To decrease the output voltage, the user should connect a resistor between Pin 6 and Pin 5 (SENSE(-) input). For a desired decrease of the nominal output voltage, the value of the resistor should be Rtrim-down = - 10.22 (511 D% ) [kW] where D% = Vnominal – Vdesired Vnominal x 100[%] To increase the output voltage, the user should connect a resistor between Pin 6 and Pin 7 (SENSE(+) input). For a desired increase of the nominal output voltage, the value of the resistor should be Rtrim-up = where ( 5.11VOUT x (100+D%) 1.225D% _ 511 _ 10.22 D% ) [kW] Vout = Nominal Output Voltage Trim graphs show the relationship between the trim resistor value Rtrim-up and Rtrim-down, showing the total range the output voltage can be trimmed up or down. Note: the TRIM feature does not affect the voltage at which the output over-voltage protection circuit is triggered. Trimming the output voltage too high may cause the over-voltage protection circuit to engage, particularly during transients. Do not add decoupling capacitance at the Trim pin. The node is internally bypassed to eliminate noise. Total DC Variation of VOUT: For the converter to meet its full specifications, the maximum variation of the dc value of Vout, due to both trimming and remote sensing voltage drops, should not be greater than that specified for the output voltage trim range. Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 PROTECTION FEATURES Input Under-Voltage Lockout: The converter is designed to turn off when the input voltage is too low, helping avoid an input system instability problem, described in more detail in the application note titled “Input System Instability” on our website. The lockout circuitry is a comparator with dc hysteresis. When the input voltage is rising, it must exceed the typical TurnOn Voltage Threshold value (listed on the specifications page) before the converter will turn on. Once the converter is on, the input voltage must fall below the typical Turn-Off Voltage Threshold value before the converter will turn off. Output Current Limit: The maximum current limit remains constant as the output voltage drops. However, once the output voltage drops below the specified Output DC Current-Limit Shutdown Voltage, the converter turns off. The converter then enters a “hiccup mode” where it repeatedly turns on and off at a 5 Hz (nominal) frequency with a 5 % duty cycle until the overload is removed. This prevents excessive heating of the converter or the system board. Output Over-Voltage Limit: If the voltage across the output pins exceeds the Output Over-Voltage Protection threshold, the converter will immediately stop switching. This prevents damage to the load circuit due to 1) excessive series resistance in output current path from converter output pins to sense point, 2) a release of a overload condition, or 3) a release of a current limit condition. Load capacitance determines exactly how high the output voltage will rise in response to these conditions. After 200 ms the converter will automatically restart. Over-Temperature Shutdown: A temperature sensor on the internal converter PCB senses the average temperature of the module. The thermal shutdown circuit is designed to turn the converter off when the temperature at the sensed location reaches the Over-Temperature Shutdown value. It will allow the converter to turn on again when the temperature of the sensed location falls by the amount of the Over-Temperature Shutdown Restart Hysteresis value. www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 21 Technical Specification IQ1BxxxHPXxxx Application Section APPLICATION CONSIDERATIONS Input System Instability: This condition can occur because any dc-dc converter appears incrementally as a negative resistance load. A detailed application note titled “Input System Instability” is available on the SynQor website which provides an understanding of why this instability arises, and shows the preferred solution for correcting it. The Electrical Characteristics Table indicates a “Recommended External Input Capacitance”. The value needed for that capacitance and ESR can vary based on application parameters. Input stability can be evaluated using our “Stability Calculator” tool in the Technical Support section of our website www.synqor.com. Application Circuits: Figure C provides a typical circuit diagram which details the input filtering and voltage trimming. Vin(+) External Input Filter Vin Electrolytic Capacitor Vout(+) Vsense(+) ON/OFF Trim Vsense(_) Vin(_) Rtrim-up or Rtrim-down Cload Iload Vout(_) Figure C: Typical application circuit (negative logic unit, permanently enabled). Input Filtering and External Capacitance: Figure D provides a diagram showing the internal input filter components. This filter dramatically reduces input terminal ripple current, which otherwise could exceed the rating of an external electrolytic input capacitor. The recommended external input capacitance is specified in the Input Characteristics section on the Electrical Characteristics page. The input capacitance need not exactly match the specified value. More detailed information is available in the application note titled “EMI Characteristics” on the SynQor website. L Vin(+) C Vin(_) Figure D: Internal Input Filter Diagram (component values listed on the input characteristics page). Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 22 Technical Specification IQ1BxxxHPXxxx Application Section Startup Inhibit Period: The Startup Inhibit Period ensures that the converter will remain off for approximately 200 ms when it is shut down for any reason. When an output short is present, this generates a 5 Hz “hiccup mode,” which prevents the converter from overheating. In all, there are seven ways that the converter can be shut down, initiating a Startup Inhibit Period: • InputUnder-VoltageLockout When the ON/OFF pin goes low after t2, and the Startup Inhibit Period has elapsed, and the output turns on within the typical Turn-On Time. Thermal Considerations: The maximum operating baseplate temperature, TB, is 100 ºC. As long as the user’s thermal system keeps TB < 100 ºC, the converter can deliver its full rated power. A power derating curve can be calculated for any heatsink that is attached to the baseplate of the converter. It is only necessary to determine the thermal resistance, RTHBA, of the chosen heatsink between the baseplate and the ambient air for a given airflow rate. This information is available from the heatsink vendor. The following formula can then be used to determine the maximum power the converter can dissipate for a given thermal condition if its baseplate is to be no higher than 100 ºC. • InputOver-VoltageShutdown • OutputOver-VoltageProtection • OverTemperatureShutdown • CurrentLimit(whenVoutisbelowshutdownvoltage) • ShortCircuitProtection • TurnedoffbytheON/OFFinput Figure E shows three turn-on scenarios, where a Startup Inhibit Period is initiated at t0, t1, and t2: Before time t0, when the input voltage is below the UVL threshold, the unit is disabled by the Input Under-Voltage Lockout (UVL) feature. When the input voltage rises above the UVL threshold, the Input Under-Voltage Lockout is released, and a Startup Inhibit Period is initiated. At the end of this delay, the ON/OFF pin is evaluated, and since it is active, the unit turns on. At time t1, the unit is disabled by the ON/OFF pin, and it cannot be enabled again until the Startup Inhibit Period has elapsed. max Pdiss = 100 ºC - TA RTHBA This value of power dissipation can then be used in conjunction with the data shown in Figure 2 to determine the maximum load current (and power) that the converter can deliver in the given thermal condition. We recommend that a suitable thermal interface material such as a thermally conductive pad or grease be used to assure a good thermal interface between the base plate and the conductive cooling device. Vin Under-Voltage Lockout TurnOn Threshold ON/OFF (neg logic) ON OFF ON OFF ON 10ms Vout (typical turn on time) 200ms 215ms (initial start-up inhibit period) (typical start-up inhibit period) t1 t0 200ms t2 t Figure E: Startup Inhibit Period (turn-on time not to scale) Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 23 Technical Specification IQ1BxxxHPXxxx Standards & Qualification Testing Parameter Notes & Conditions STANDARDS COMPLIANCE UL 60950-1/R:2011-12 Reinforced Insulation CAN/CSA-C22.2 No. 60950-1/A1:2011 EN 60950-1/A2:2013 CE Marked 2006/95/EC Low Voltage Directive Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new releases or download from the SynQor website. Parameter # Units Test Conditions QUALIFICATION TESTING Life Test 32 95 % rated Vin and load, units at derating point, 1000 hours Vibration 5 10-55 Hz sweep, 0.060 " total excursion, 1 min./sweep, 120 sweeps for 3 axis Mechanical Shock 5 100 g minimum, 2 drops in x, y, and z axis Temperature Cycling 10 -40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles Power/Thermal Cycling 5 Toperating = min to max, Vin = min to max, full load, 100 cycles Design Marginality 5 Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105 % load Humidity 5 85 °C, 95 % RH, 1000 hours, continuous Vin applied except 5 min/day Solderability 15 pins Altitude 2 MIL-STD-883, method 2003 70,000 feet (21 km), see Note Note: A conductive cooling design is generally needed for high altitude applications because of naturally poor convective cooling at rare atmospheres. Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 24 Technical Specification IQ1BxxxHPXxxx Standard Mechanical Diagram 2.486 [63.14] 2.000 [50.80] SEATING PLANE HEIGHT 0.512±0.005 [ 13.00±0.12 ] PIN EXTENSION 0.163 [4.14] 1.000 [25.40] 0.700 [17.78] 4 TOP VIEW 5 6 7 8 0.004 [0.10] 1.900 2.386 [48.26] [60.60] 0.01 [0.3] 1.900 [48.26] 3 1 0.30 [7.6] 1 0.400 [10.16] THRU HOLE STANDOFFS SEE NOTE 1 (4 PLCS) NOTES 1) THREADED: APPLIED TORQUE PER M3 SCREW 4in-lb RECOMMENDED (5in-lb LIMIT). NONTHREADED: DIA 0.125" (3.18mm) 2) BASEPLATE FLATNESS TOLERANCE IS 0.004" (.10mm) TIR FOR SURFACE. 3) PINS 1-3 AND 5-7 ARE 0.040" (1.02mm) DIA. WITH 0.080" (2.03mm) DIA. STANDOFFS. 4) PINS 4 AND 8 ARE 0.080" (2.03mm) DIA. WITH 0.125" (3.18mm) DIA STANDOFFS 5) ALL PINS: MATERIAL: COPPER ALLOY FINISH: MATTE TIN OVER NICKEL PLATE 6) WEIGHT: 4.7 oz (133 g) 7) ALL DIMENSIONS IN INCHES(mm) TOLERANCES: X.XXIN +/-0.02 (X.Xmm +/-0.5mm) X.XXXIN +/-0.010 (X.XXmm +/-0.25mm) Product # IQ1BxxxHPXxxx 2 Phone 1-888-567-9596 1.400 [35.56] Pin 1 Name Vin(+) 2 ON/OFF PIN DESIGNATIONS Function Positive input voltage TTL input to turn converter on and off, referenced to Vin(–), with internal pull up. Negative input voltage Negative output voltage Negative remote sense(see note 1) Output voltage trim (see note 2) Positive remote sense (see note 3) Positive output voltage 3 Vin(–) 4 Vout(–) 5 SENSE(–) 6 TRIM 7 SENSE(+) 8 Vout(+) Notes: 1) SENSE(–) should be connected to Vout(–) either remotely or at the converter. 2) Leave TRIM pin open for nominal output voltage. 3) SENSE(+) should be connected to Vout(+) either remotely or at the converter. www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 25 Technical Specification IQ1BxxxHPXxxx Flanged Mechanical Diagram SEATING PLANE HEIGHT 0.495±0.025 [ 12.57±0.63 ] 3.150 [80.01] 2.950 [74.93] 2.486 [63.14] PIN EXTENSION 0.180 [4.57] 1.000 [25.40] 0.700 [17.78] 4 5 6 7 8 TOP VIEW 1.300 [33.02] 0.010 [0.25] 1.900 [48.26] 1.866 [47.40] 0.31 [7.9] 2.386 [60.60] 3 2 1 1 0.775±0.020 [ 19.69±0.50 ] FLANGE THICKNESS 0.125 [3.18] .130 [3.30] SEE NOTE 1 (6 PLCS) NOTES 1) APPLIED TORQUE PER M3 OR 4-40 SCREW 4in-lb RECOMMENDED (5in-lb LIMIT) 2) BASEPLATE FLATNESS TOLERANCE IS 0.010" (.25mm) TIR FOR SURFACE. 3) PINS 1-3 AND 5-7 ARE 0.040" (1.02mm) DIA. WITH 0.080" (2.03mm) DIA. STANDOFFS. 4) PINS 4 AND 8 ARE 0.080" (2.03mm) DIA. WITH 0.125" (3.18mm) DIA STANDOFFS 5) ALL PINS: MATERIAL: COPPER ALLOY FINISH: MATTE TIN OVER NICKEL PLATE 6) WEIGHT: 4.9 oz (139 g) 7) ALL DIMENSIONS IN INCHES(mm) TOLERANCES: X.XXIN +/-0.02 (X.Xmm +/-0.5mm) X.XXXIN +/-0.010 (X.XXmm +/-0.25mm) Product # IQ1BxxxHPXxxx Phone 1-888-567-9596 0.400 [10.16] 1.400 [35.56] Pin 1 Name Vin(+) 2 ON/OFF PIN DESIGNATIONS Function Positive input voltage TTL input to turn converter on and off, referenced to Vin(–), with internal pull up. Negative input voltage Negative output voltage Negative remote sense(see note 1) Output voltage trim (see note 2) Positive remote sense (see note 3) Positive output voltage 3 Vin(–) 4 Vout(–) 5 SENSE(–) 6 TRIM 7 SENSE(+) 8 Vout(+) Notes: 1) SENSE(–) should be connected to Vout(–) either remotely or at the converter. 2) Leave TRIM pin open for nominal output voltage. 3) SENSE(+) should be connected to Vout(+) either remotely or at the converter. www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 26 Technical Specification IQ1BxxxHPXxxx PART NUMBERING SYSTEM ORDERING INFORMATION The part numbering system for SynQor’s dc-dc converters follows the format shown in the example below. The tables below show the valid model numbers and ordering options for converters in this product family. When ordering SynQor converters, please ensure that you use the complete 15 character part number consisting of the 12 character base part number and the additional characters for options. InQor units are only available with 6/6 RoHS compliance indicated by "-G". IQ 1 B 0 3 3 H P C 6 0 N R S - G Model Number 6/6 RoHS Options (see Ordering Information) Output Current Thermal Design Performance Level Package Size Output Voltage IQ1B033HPw60NRS IQ1B050HPw48NRS IQ1B120HPw21NRS IQ1B150HPw17NRS IQ1B240HPw10NRS IQ1B280HPw09NRS IQ1B400HPw06NRS IQ1B480HPw5CNRS Input Voltage 66V-160 V 66V-160 V 66V-160 V 66V-160 V 66V-160 V 66V-160 V 66V-160 V 66V-160 V Output Voltage 3.3 V 5V 12 V 15 V 24 V 28 V 40 V 48 V Max Output Current 60 A 48 A 21 A 17 A 10 A 9A 6.3 A 5.2 A Input Voltage Product Family The first 12 characters comprise the base part number and the last 3 characters indicate available options. The “-G” suffix indicates 6/6 RoHS compliance. Application Notes A variety of application notes and technical white papers can be downloaded in pdf format from our website. The following options must be included in place of the w x y z spaces in the model numbers listed above. Thermal Design w Options Description Enable Logic Pin Style x y C - Encased D - Encased with Non-Threaded Baseplate V - Encased with Flanged Baseplate N - Negative Feature Set z R - 0.180" S - Standard RoHS Compliance: The EU led RoHS (Restriction of Hazardous Substances) Directive bans the use of Lead, Cadmium, Hexavalent Chromium, Mercury, Polybrominated Biphenyls (PBB), and Polybrominated Diphenyl Ether (PBDE) in Electrical and Electronic Equipment. This SynQor product is 6/6 RoHS compliant. For more information please refer to SynQor’s RoHS addendum available at our RoHS Compliance / Lead Free Initiative web page or e-mail us at [email protected]. Not all combinations make valid part numbers, please contact SynQor for availability. Contact SynQor for further information and to order: PATENTS Phone: Toll Free: Fax: E-mail: Web: Address: Product # IQ1BxxxHPXxxx 978-849-0600 888-567-9596 978-849-0602 [email protected] www.synqor.com 155 Swanson Road Boxborough, MA 01719 USA Phone 1-888-567-9596 SynQor holds numerous U.S. patents, one or more of which apply to most of its power converter products. Any that apply to the product(s) listed in this document are identified by markings on the product(s) or on internal components of the product(s) in accordance with U.S. patent laws. SynQor’s patents include the following: 5,999,417 6,222,742 6,545,890 6,594,159 6,731,520 6,894,468 6,896,526 6,927,987 7,050,309 7,072,190 7,085,146 7,119,524 7,269,034 7,272,021 7,272,023 7,558,083 7,564,702 7,765,687 7,787,261 8,023,290 8,149,597 8,493,751 8,644,027 Warranty SynQor offers a two (2) year limited warranty. Complete warranty information is listed on our website or is available upon request from SynQor. www.synqor.com Doc.# 005-0005023 Rev. J 04/13/15 Page 27