L6360 and L6362A Embracing the Industry 4.0 revolution Master and device solution for IO-Link and general-purpose (SIO-mode) transceivers ST’s L6360 and L6362A enable a master and device solution for IO-Link and general-purpose transceivers via a single 3-wire connection (PHY2). They represent a compact, efficient and robust solution for Smart Industry (Industry 4.0) applications. The two monolithic ICs meet all the requirements of modern sensors and actuators such as fast and easy configurability, wide application spectrum, minimum power dissipation for increased efficiency and full diagnostic and protection functions for enhanced reliability. The half-bridge output stages can be configured as highside, low-side or push-pull for maximum design flexibility. KEY FEATURES & BENEFITS Maximum reliability Wide application spectrum • LED diagnostics sequence generator for • Wide supply voltage range: 18 to 32.5 V (L6360), 7 to 36 V (L6362A) • High output current capability: up to 500 mA (L6360), 220 mA (L6362A) fast reaction to faults conditions in L6360 • Integrated short circuit, over-current & over-temperature and over-voltage & under-voltage protection functions Maximum design flexibility • Selectable output stage: high-side, low- IDEAL FOR side, push-pull • Easy access and full configurability in I2C mode with L6360 • Selectable linear regulators: 3.3 / 5 V, 50 mA (L6360), 10 mA (L6362A) • Driving digital sensors and actuators • Input-output for programmable logic controllers (PLC) • Line drivers Maximum efficiency • Minimum power dissipation with best-in- class RDS(on) <1.6 Ω (L6362A), <2 Ω (L6360) www.st.com/iolink STMicroelectronics’ L6360 and L6362A transceivers transmit and receive digital data via a single 3-wire connection (PHY2) supporting COM1 (4.8 kbaud), COM2 (38.4 kbaud) and COM3 (230.4 kbaud) modes. Both devices integrate a selectable linear regulator. In the master L6360 a fast mode I²C bus makes the system highly configurable and easily programmable. High reliability is provided through programmable cut-off current, delay time, They are compliant with burst tests, surge tests and ESD immunity tests, based on the IO-Link specification and SIO mode requirements thus representing an ideal solution for driving digital sensors in Industry 4.0 applications. Supply voltage is monitored and low voltage conditions are detected. The devices are housed in tiny packages: L6360 in a 26-lead QFN (3.5 x 5 x 1 mm) and L6362A in a 12-lead DFN (3 x 3 x 1 mm). VCC VDD1 Industrial sensor UART 8- or 32-bit microcontroller restart delay and filter time on the C/Qi digital. In addition, cut-off current and delay time, combined with current limitation and thermal shutdown, protect the ICs against overload and short circuit, for safe operation. I 2C L6360 GPIO VCC L+ OUTH OUTL L6362A I/Q L+ C/Qo C/Qi L- Diodes and protection OL Inputs 8- or 32-bit microcontroller Signal conditioning GND I/Q Analog front-end 3 wire cable Process variables (proximity, pressure, temperature) PRODUCT RANGE Supply voltage (V) V∞ (V) Output current (A) Linear regulator output current (mA) Output channels Input channels Package L6360 (Master) 18 to 32.5 3.3/5 0.5 50 2 2 QFN 26L (3.5 x 5 mm) L6362A (Device) 7 to 36 3.3/5 0.22 10 1 1 DFN 12L (3 x 3 mm) Part number EVALUATION BOARDS Order code Description Application notes STEVAL-IFP016V2 IO-Link communication master transceiver evaluation board based on the L6360 AN4075 STEVAL-IFP017V3 IO-Link communication transceiver evaluation board based on the L6362A AN4828 © STMicroelectronics - April 2016 - Printed in United Kingdom - All rights reserved The STMicroelectronics corporate logo is a registered trademark of the STMicroelectronics group of companies All other names are the property of their respective owners Order code: FL6360X0316 For more information on ST products and solutions, visit www.st.com/iolink