X

PRO2200
Professional Modular Access Control Hardware
PRO2200 Access Control Hardware
a supervised RS485 bus. Hardware interface configuration options
As a part of the WIN-PAK software controlled hardware family the
are stored in the main controller and may be directly controlled via
PRO2200 professional modular access control hardware is an
operator intervention, time schedules or event-based procedures.
advanced access control panel capable of providing solutions where
The modules have been designed to allow for a modular
installation space is at a premium. The design of the hardware is
customisable solution.
modular and flexible and can be tailored to meet a wide range of
PRO2200 Reader Modules
®
applications, while optimising cost and mounting space.
The PRO22R1 provides I/O support for one card access reader to
The PRO2200 system is connected to a host computer with WIN-PAK
control one door, while the PRO22R2 supports two card access
for system configuration, alarm monitoring and direct control. Using
readers to control two doors. In the event that communication to the
WIN-PAK, at least 255 PRO2200 systems can be connected to create
intelligent control module is lost, the card access readers can be
large access control solutions.
individually configured to allow entrance based on security needs.
Every PRO2200 consists of a main controller, an enclosure, a power
This customisation allows for a door to be configured as locked,
supply, reader and I/O modules. A PRO2200 system can be set up as
unlocked or access only via a valid facility code.
an access control system with up to 16 doors, protected with one
PRO2200 I/O Modules
reader. If additional inputs and outputs are needed for extra control
within the PRO2200 system, the number of controllable doors will be
limited to less than 16 doors. The access control limitations depend on
the amount of extra controllable inputs and outputs needed within the
modular configuration of up to eight I/O or reader boards.
The PRO22OUT module provides 12 Form C, 12 VDC, 2A relay
output controls when mounted in a high density rack mount
enclosure (PRO22ENC1 and PRO22ENC2). If the board is tile
mounted in a PRO22ENC3, four extra Form C, 12 VDC, 2A relay
output controls and power fail and panel tamper inputs are
Designed to fit into tight spaces, the PRO2200 with its rack-mount
provided. Relays may be used for lift control, status annunciation
design provides high-density installations for up to 16 doors in a small
and for general facility control.
space. The design makes it ideal for applications where eight or more
doors are needed. Metal enclosures for up to two modules are
available for remote located controllable doors, connected via a
supervised RS485 bus.
The PRO22IN module provides 16 supervised alarm inputs and a
dedicated power fail and panel tamper when tile mounted. The
inputs can be supervised with end-of-line resistors or nonsupervised (digital). Inputs may be used for status and for general
PRO2200 Main Controller
facility monitoring, such as door monitoring.
The PRO2200 main controller board (PRO22IC) accommodates a card
PRO2200 Enclosures
database of 20,000 cards, a transaction buffer of 5,000 transactions
and is designed to operate off-line, making access control decisions
independently from a PC or other controlling device.
The PRO2200 main controller and modules are designed to
accommodate various mounting options. Units can be mounted in a
high-density rack configuration (PRO22ENC1 and PRO22ENC2) when
The PRO22IC supports any combination of up to eight I/O or reader
space is limited or in a tile-mount configuration (PRO22ENC3) for
boards to monitor alarm input points, relay output points and access
remotely located doors and I/O. A high-density enclosure can facilitate
control reader interface points. Connectivity to the host computer with
a power supply, a main controller and up to eight modules.
WIN-PAK is accomplished via a TCP/IP add-on module, serial (RS232
• PRO22ENC1 is a wall-mounted high-density enclosure
or RS485) communication or dial-up modem.
PRO2200 Modules
The PRO2200 professional series family of access control modules is
connected to an interface with the main controller (PRO22IC) through
• PRO22ENC2 is a 19" rack-mounted high-density enclosure
• PRO22ENC3 is a wall-mounted remote enclosure for up to two
modules or main controllers
PRO2200
Professional Modular Access Control Hardware
S Y S T E M F E AT U R E S
• Configurable via WIN-PAK access
control software
• At least 225 PRO2200 systems
• Supervised communication and lithium
access control decisions to be made by
to meet the needs of large access control
controller in real time without the need to
and security systems
communicate to the server
protocols to allow intelligent controller(s) to
to accommodate future growth beyond its
tap into a LAN or WAN
• Rack or tile mounting options available
PRO22IC RS485 ports at 38,400 bps.
1250mtotal bus length per port.
• Accommodates a card database of
20,000 cards, and a transaction buffer of
5,000 transactions
• Seamless optional support for TCP/IP
performance with a seamless upgrade path
initial installation
modules may be connected to the
• Large, local controller database allows
configurable in a WIN-PAK hosted system
• Scalable architecture ensures optimal
• Any combination of eight I/O or reader
battery backup ensures system reliability
• Option to include or exclude fields during
database configuration to maximise
memory usage
• True 32-bit microprocessor provides fast
transaction processing for the most
• Automatic calculation of leap-year and
daylight savings
demanding network applications
A C C E S S C O N T R O L F E AT U R E S
• Supports a wide range of reader
technologies including Wiegand, magnetic
stripe, proximity and keypad
• Supports multiple reader and card formats
for maximum flexibility and security options
• System off-line modes customisable per
• Configurable as fail-secure (energise to
• ADA compliant allowing expanded door
times selectable per reader
• Up to 12 intervals per time zone where
• Anti-passback support - free pass and
day map. The day map indicates the day of
exempt flags, last area accessed, last reader
accessed and time /date of last access
card or PIN and PIN only
• Activation and deactivation dates by card
each interval is a start time, stop time and
(no access) and unlocked (full access)
facility code, card only, card and PIN,
up to eights digits
• Up to eight card formats per reader
reader include facility code access, locked
• Operating modes include locked, unlocked,
• Personal Identification Number (PIN) with
activate) or fail-safe (de-energise to activate)
the week or holiday
• 255 possible holidays are defined by a
starting date and duration
• Up to 32 access levels per card or
individual time zones per readers
• Entire card bit-stream reported with invalid
facility code or invalid card format
• 9-digit (32-bit) user ID standard /
15-digit maximum
I N P U T / O U T P U T C O N T R O L F E AT U R E S
• User programmable relay outputs allow for
specific control needs
• Pulse control: single pulse (up to 24 hours)
or repeating pulses (on/off in 0.1 second
increments, up to 255 times)
• Configurable as standard, entry delay
• Alarm circuit type - normally open, normally
latching, entry delay non-latching and
closed, non-supervised, supervised (with
exit delay
correct EOL). Meets requirements for
• User programmable alarm inputs offer
UL294 and CUL
flexible system configuration and control
E N C L O S U R E F E AT U R E S
• Up to nine modules, power-supply and
• Auto switching power supply allows
• Up to 2 modules and battery can be
battery can be accommodated by the
110 / 220 operation with PRO22E1PSE in
accommodated by the PRO22ENC3
PRO22ENC1 and PRO22ENC2 enclosures
PRO22ENC1 and PRO22ENC2
enclosure for remote door installation
(PSX220 transformer required for
mains power)
S Y S T E M S P E C I F I C AT I O N S
• PRO22ENC3 (Tile-mount)
Database:
Access Modules:
• Flash programming for firmware
• Eight total devices available per controller
Capacity: Two modules. Battery included.
• Access modules available:
Recommended Power Supply: PSX220
revision updates
Transformer 240VAC / 16VAC
• Memory for 20,000 cards
- Single reader module (PRO22R1)
• Memory for 5,000 events
- Dual reader module (PRO22R2)
Dimensions:
• Access codes: Unlimited
- 16 relay output module (PRO22OUT)
• Board: 22.86 cm H x 13.97 cm W
• Holidays: Unlimited
- 16 alarm input module (PRO22IN)
• Time codes: 255
• Card reader formats: eight per reader
• Credential facility codes: eight
• Lift support: 128 floors
• Dedicated tamper alarm
• Dedicated power fail alarm
• Real time clock:
- Geographic time zone support
- Daylight Saving Time
- Leap year support
- 4-bit parallel accurate to 50 ppm
• Precision access groups/levels
• Multiple access groups/levels
• Module connectivity via RS485
protocol (1250m)
Access Control Operational
Functionality:
• Duress detection
• Operational modes:
x 22.86 cm D
• PRO22ENC2: 35.3 cm H x 48 cm W
x 22.86 cm D
• PRO22ENC3: 35.56 cm H x 40.64 cm W
x 10.2 cm D
- Card only
Environment (Controllers):
- PIN only
• Temperature: 0°C to 70°C operational;
- Card or PIN
- Card and PIN
-55°C to 85°C storage
• Humidity: 0 to 95% RHNC
- Facility code only
• Maximum PIN size: 8 digits
Environment (Modules):
• Door object support
• Temperature: 0°C to 49°C operational;
Communication Modules:
• Threat level support: 100 levels
• Primary communication support:
• Two person access rule
- RS232
x 2.54 cm D
• PRO22ENC1: 35.3 cm H x 43.18 cm W
• Offline modes (selectable per reader):
-55°C to 85°C storage
• Humidity: 0 to 85% RHNC
Wiring Requirements:
- RS485
- Facility code access
- Dial-up modem*
- Locked (no access)
• Power - twisted pair, 18 AWG
- Ethernet (TCP/IP)*
- Unlocked (free access)
• RS485 - 24 AWG, 1,200m max, two
• Communication speed: 38.4 Kbps
• Automatic dial back:
- Dial-back on alarm condition
- Dial-back on transaction buffer
capacity reached
- Dial-back on primary power loss
• Download functionality:
- System functional during system
download: Yes
- System functional during credential
download: Yes
*Requires additional hardware
• Anti-Passback support:
- While preventing access (hard)
- While allowing access (soft)
• Transaction prioritisation: 99 levels
Enclosures:
• PRO22ENC1 (Wall-mount)
Capacity: nine modules.
Power supply and battery not included
• PRO22ENC2 (19" Rack-mount)
Capacity: nine modules.
Power supply and battery not included
twisted pairs with shield (120 W, 23 pF,
Belden 9842 or equivalent)
• RS232 - 24AWG, 7.6 m max
• Alarm input - twisted pair, 30 ohms max
PRO2200
Professional Modular Access Control Hardware
M O D U L E S P E C I F I C AT I O N S
Reader Modules
PRO2200 Series Single Reader Module (PRO22R1)
Module Specifications
Port
1 reader port - 12 VDC at 50 mA, clock / data or data0 / data1
Keypad
2 reader ports - 12 VDC at 50 mA, clock / data or data0 / data1
Keypad multiplexed with card data
Wire Support
Two-wire or one-wire bi-colour LED support
Buzzer Support
Buzzer support only with one-wire LED control
Door Alarm Inputs
2 supervised, door status and egress inputs with
programmable circuit type
4 supervised, door status and egress inputs and 2 general
purpose alarm inputs with programmable circuit type (2 additional
supervised inputs available when using PRO22ENC3 enclosure)
1 dedicated alarm input for tamper detection
2 dedicated alarm inputs for tamper detection and power loss
Alarm Inputs
Door Control Relays
Output Relays
1 door control output relay, form C, 5 A 28 VDC
2 general purpose output relays, form C, 5 A 28 VDC
1 general purpose output relay, form C, 1 A 28 VDC
2 general purpose output relays, form C, 2 A 28 VDC (2 additional
output relays available when using PRO22ENC3 enclosure)
Alarm Input Properties
Inputs
Circuit Type
PRO2200 Series Dual Reader Module (PRO22R2)
Inputs may be assigned to door related functions or general purpose I/O
Circuit type - normally open, normally closed, non-supervised, supervised (with standard 1K or custom end-of-line resistance 200-10K)
Line Conditioning
Line conditioning - programmable sensitivity and hold time
Output Control Properties
Outputs
Outputs may be assigned to door related functions or general purpose I/O
Relay Rating
The 5 A relay(s) are rated to handle the inductive loads of door locking devices
Configurable
Configurable as fail-secure (energise to activate) or fail-safe (de-energise to activate)
Pulse Time
1-32,400 seconds, 1-255 for door relays
RS485 Port
RS485 port, 1,250m total bus length
Default Speed
38.4 Kbps
I/O Modules
PRO2200 Series 16 Relay Output Module (PRO22OUT)
Module Specifications
Alarm Inputs
Alarm Inputs
Output Relays
PRO2200 Series 16 Alarm Input Module (PRO22IN)
2 dedicated alarm inputs for tamper detection and power loss (tile-mounted only)
N/A
16 general purpose inputs with programmable circuit type
12 general purpose output relays, form C, 2 A 30 VDC (four
additional are available when using PRO22ENC3 enclosure)
1 general purpose, form C, 2 A 30 VDC relay (one additional is
available when using PRO22ENC3 enclosure)
Output Control Properties
Outputs
All 16 relay outputs (mounted in PRO22ENC3) or 12 relay
outputs (in PRO22ENC1 and PRO22ENC2) are available for
general purpose I/O
Both relay outputs are available for general purpose I/O
The 2 A relays are rated to handle dry circuit logic
Both relay outputs are rated to handle dry circuit logic
Dry Circuit Logic
Pulse Time
Configurable
1-32,400 seconds
Configurable as fail-secure (energise to activate) or fail-safe
(de-energise to activate)
N/A
Alarm Input Properties
Inputs
N/A
All 16 inputs may be assigned to door related functions
or general purpose I/O
Circuit Type
N/A
Circuit type - normally open, normally closed, non-supervised,
supervised (with correct EOL)
Line Conditioning
N/A
Line conditioning - programmable sensitivity and hold time
Communication Features
Measurements
Default Speed
RS485 port, 1250m total bus length per port
38.4 Kbps
T Y P I C A L S Y S T E M C O N F I G U R AT I O N
PRO22ENC1 and PRO22ENC2
Module
Reader
Inputs
Outputs
PRO22R1
1
N/A
PRO22R2
2
6
PRO22OUT
0
PRO22IN
0
PRO22ENC3
Inputs
Outputs
N/A
2
2
4
10**
6
0
12
2**
16
16
1
18**
2
**Two are used to monitor Power and Tamper
PRO22ENC1 and PRO22ENC2=9 Board Capacity / PRO22ENC3=2 Board Capacity
PRO2200
Professional Modular Access Control Hardware
ORDERING
PRO2200 Controllers
PRO2200 High Density Enclosures and Accessories
PRO22IC
PRO2200 Intelligent Controller
PRO22ENC1
PRO22R1
PRO2200 Single Reader Module
supply, main controller and up to eight modules.
PRO22R2
PRO2200 Dual Reader Module
Power supply and battery not included
PRO22OUT
PRO2200 16* Relay Output Module
PRO22IN
PRO2200 16 Alarm Input Module
PRO22ENC2
modules. Power supply and battery not included
Ethernet daughter board for TCP/IP
PRO22E1PSE
communication for PRO22IC
PCI3
19" Rack-mount, high-density enclosure for
power supply, main controller and up to eight
Communication Devices
PRO22EN
Wall-mount, high-density enclosure for power
110V/240VAC - 12VDC /4 A rack-mounted
power supply with battery backup
RS232 to RS485 single port converter
PRO22DCC
PRO2200 power/communication daisy chain
harness
PRO2200 Remote Enclosure and Accessories
PRO22ENC3
Wall-mount enclosure with battery for two
modules. Power supply not included
PSX220
* Only 12 relay outputs are available when using the PRO22ENC1 and PRO22ENC2 enclosures
For more information, visit
www.honeywell.com/security/uk
Honeywell Security Group
Charles Avenue
Burgess Hill
West Sussex
RH15 9UF
Tel: 08448 006 890
www.honeywell.com
HAS-PRO2200-01-UK(0411)DS-E
April 2011
© 2011 Honeywell International Inc.
240VAC / 16VAC transformer