PRO2200 Professional Modular Access Control Hardware PRO2200 Access Control Hardware a supervised RS485 bus. Hardware interface configuration options As a part of the WIN-PAK software controlled hardware family the are stored in the main controller and may be directly controlled via PRO2200 professional modular access control hardware is an operator intervention, time schedules or event-based procedures. advanced access control panel capable of providing solutions where The modules have been designed to allow for a modular installation space is at a premium. The design of the hardware is customisable solution. modular and flexible and can be tailored to meet a wide range of PRO2200 Reader Modules ® applications, while optimising cost and mounting space. The PRO22R1 provides I/O support for one card access reader to The PRO2200 system is connected to a host computer with WIN-PAK control one door, while the PRO22R2 supports two card access for system configuration, alarm monitoring and direct control. Using readers to control two doors. In the event that communication to the WIN-PAK, at least 255 PRO2200 systems can be connected to create intelligent control module is lost, the card access readers can be large access control solutions. individually configured to allow entrance based on security needs. Every PRO2200 consists of a main controller, an enclosure, a power This customisation allows for a door to be configured as locked, supply, reader and I/O modules. A PRO2200 system can be set up as unlocked or access only via a valid facility code. an access control system with up to 16 doors, protected with one PRO2200 I/O Modules reader. If additional inputs and outputs are needed for extra control within the PRO2200 system, the number of controllable doors will be limited to less than 16 doors. The access control limitations depend on the amount of extra controllable inputs and outputs needed within the modular configuration of up to eight I/O or reader boards. The PRO22OUT module provides 12 Form C, 12 VDC, 2A relay output controls when mounted in a high density rack mount enclosure (PRO22ENC1 and PRO22ENC2). If the board is tile mounted in a PRO22ENC3, four extra Form C, 12 VDC, 2A relay output controls and power fail and panel tamper inputs are Designed to fit into tight spaces, the PRO2200 with its rack-mount provided. Relays may be used for lift control, status annunciation design provides high-density installations for up to 16 doors in a small and for general facility control. space. The design makes it ideal for applications where eight or more doors are needed. Metal enclosures for up to two modules are available for remote located controllable doors, connected via a supervised RS485 bus. The PRO22IN module provides 16 supervised alarm inputs and a dedicated power fail and panel tamper when tile mounted. The inputs can be supervised with end-of-line resistors or nonsupervised (digital). Inputs may be used for status and for general PRO2200 Main Controller facility monitoring, such as door monitoring. The PRO2200 main controller board (PRO22IC) accommodates a card PRO2200 Enclosures database of 20,000 cards, a transaction buffer of 5,000 transactions and is designed to operate off-line, making access control decisions independently from a PC or other controlling device. The PRO2200 main controller and modules are designed to accommodate various mounting options. Units can be mounted in a high-density rack configuration (PRO22ENC1 and PRO22ENC2) when The PRO22IC supports any combination of up to eight I/O or reader space is limited or in a tile-mount configuration (PRO22ENC3) for boards to monitor alarm input points, relay output points and access remotely located doors and I/O. A high-density enclosure can facilitate control reader interface points. Connectivity to the host computer with a power supply, a main controller and up to eight modules. WIN-PAK is accomplished via a TCP/IP add-on module, serial (RS232 • PRO22ENC1 is a wall-mounted high-density enclosure or RS485) communication or dial-up modem. PRO2200 Modules The PRO2200 professional series family of access control modules is connected to an interface with the main controller (PRO22IC) through • PRO22ENC2 is a 19" rack-mounted high-density enclosure • PRO22ENC3 is a wall-mounted remote enclosure for up to two modules or main controllers PRO2200 Professional Modular Access Control Hardware S Y S T E M F E AT U R E S • Configurable via WIN-PAK access control software • At least 225 PRO2200 systems • Supervised communication and lithium access control decisions to be made by to meet the needs of large access control controller in real time without the need to and security systems communicate to the server protocols to allow intelligent controller(s) to to accommodate future growth beyond its tap into a LAN or WAN • Rack or tile mounting options available PRO22IC RS485 ports at 38,400 bps. 1250mtotal bus length per port. • Accommodates a card database of 20,000 cards, and a transaction buffer of 5,000 transactions • Seamless optional support for TCP/IP performance with a seamless upgrade path initial installation modules may be connected to the • Large, local controller database allows configurable in a WIN-PAK hosted system • Scalable architecture ensures optimal • Any combination of eight I/O or reader battery backup ensures system reliability • Option to include or exclude fields during database configuration to maximise memory usage • True 32-bit microprocessor provides fast transaction processing for the most • Automatic calculation of leap-year and daylight savings demanding network applications A C C E S S C O N T R O L F E AT U R E S • Supports a wide range of reader technologies including Wiegand, magnetic stripe, proximity and keypad • Supports multiple reader and card formats for maximum flexibility and security options • System off-line modes customisable per • Configurable as fail-secure (energise to • ADA compliant allowing expanded door times selectable per reader • Up to 12 intervals per time zone where • Anti-passback support - free pass and day map. The day map indicates the day of exempt flags, last area accessed, last reader accessed and time /date of last access card or PIN and PIN only • Activation and deactivation dates by card each interval is a start time, stop time and (no access) and unlocked (full access) facility code, card only, card and PIN, up to eights digits • Up to eight card formats per reader reader include facility code access, locked • Operating modes include locked, unlocked, • Personal Identification Number (PIN) with activate) or fail-safe (de-energise to activate) the week or holiday • 255 possible holidays are defined by a starting date and duration • Up to 32 access levels per card or individual time zones per readers • Entire card bit-stream reported with invalid facility code or invalid card format • 9-digit (32-bit) user ID standard / 15-digit maximum I N P U T / O U T P U T C O N T R O L F E AT U R E S • User programmable relay outputs allow for specific control needs • Pulse control: single pulse (up to 24 hours) or repeating pulses (on/off in 0.1 second increments, up to 255 times) • Configurable as standard, entry delay • Alarm circuit type - normally open, normally latching, entry delay non-latching and closed, non-supervised, supervised (with exit delay correct EOL). Meets requirements for • User programmable alarm inputs offer UL294 and CUL flexible system configuration and control E N C L O S U R E F E AT U R E S • Up to nine modules, power-supply and • Auto switching power supply allows • Up to 2 modules and battery can be battery can be accommodated by the 110 / 220 operation with PRO22E1PSE in accommodated by the PRO22ENC3 PRO22ENC1 and PRO22ENC2 enclosures PRO22ENC1 and PRO22ENC2 enclosure for remote door installation (PSX220 transformer required for mains power) S Y S T E M S P E C I F I C AT I O N S • PRO22ENC3 (Tile-mount) Database: Access Modules: • Flash programming for firmware • Eight total devices available per controller Capacity: Two modules. Battery included. • Access modules available: Recommended Power Supply: PSX220 revision updates Transformer 240VAC / 16VAC • Memory for 20,000 cards - Single reader module (PRO22R1) • Memory for 5,000 events - Dual reader module (PRO22R2) Dimensions: • Access codes: Unlimited - 16 relay output module (PRO22OUT) • Board: 22.86 cm H x 13.97 cm W • Holidays: Unlimited - 16 alarm input module (PRO22IN) • Time codes: 255 • Card reader formats: eight per reader • Credential facility codes: eight • Lift support: 128 floors • Dedicated tamper alarm • Dedicated power fail alarm • Real time clock: - Geographic time zone support - Daylight Saving Time - Leap year support - 4-bit parallel accurate to 50 ppm • Precision access groups/levels • Multiple access groups/levels • Module connectivity via RS485 protocol (1250m) Access Control Operational Functionality: • Duress detection • Operational modes: x 22.86 cm D • PRO22ENC2: 35.3 cm H x 48 cm W x 22.86 cm D • PRO22ENC3: 35.56 cm H x 40.64 cm W x 10.2 cm D - Card only Environment (Controllers): - PIN only • Temperature: 0°C to 70°C operational; - Card or PIN - Card and PIN -55°C to 85°C storage • Humidity: 0 to 95% RHNC - Facility code only • Maximum PIN size: 8 digits Environment (Modules): • Door object support • Temperature: 0°C to 49°C operational; Communication Modules: • Threat level support: 100 levels • Primary communication support: • Two person access rule - RS232 x 2.54 cm D • PRO22ENC1: 35.3 cm H x 43.18 cm W • Offline modes (selectable per reader): -55°C to 85°C storage • Humidity: 0 to 85% RHNC Wiring Requirements: - RS485 - Facility code access - Dial-up modem* - Locked (no access) • Power - twisted pair, 18 AWG - Ethernet (TCP/IP)* - Unlocked (free access) • RS485 - 24 AWG, 1,200m max, two • Communication speed: 38.4 Kbps • Automatic dial back: - Dial-back on alarm condition - Dial-back on transaction buffer capacity reached - Dial-back on primary power loss • Download functionality: - System functional during system download: Yes - System functional during credential download: Yes *Requires additional hardware • Anti-Passback support: - While preventing access (hard) - While allowing access (soft) • Transaction prioritisation: 99 levels Enclosures: • PRO22ENC1 (Wall-mount) Capacity: nine modules. Power supply and battery not included • PRO22ENC2 (19" Rack-mount) Capacity: nine modules. Power supply and battery not included twisted pairs with shield (120 W, 23 pF, Belden 9842 or equivalent) • RS232 - 24AWG, 7.6 m max • Alarm input - twisted pair, 30 ohms max PRO2200 Professional Modular Access Control Hardware M O D U L E S P E C I F I C AT I O N S Reader Modules PRO2200 Series Single Reader Module (PRO22R1) Module Specifications Port 1 reader port - 12 VDC at 50 mA, clock / data or data0 / data1 Keypad 2 reader ports - 12 VDC at 50 mA, clock / data or data0 / data1 Keypad multiplexed with card data Wire Support Two-wire or one-wire bi-colour LED support Buzzer Support Buzzer support only with one-wire LED control Door Alarm Inputs 2 supervised, door status and egress inputs with programmable circuit type 4 supervised, door status and egress inputs and 2 general purpose alarm inputs with programmable circuit type (2 additional supervised inputs available when using PRO22ENC3 enclosure) 1 dedicated alarm input for tamper detection 2 dedicated alarm inputs for tamper detection and power loss Alarm Inputs Door Control Relays Output Relays 1 door control output relay, form C, 5 A 28 VDC 2 general purpose output relays, form C, 5 A 28 VDC 1 general purpose output relay, form C, 1 A 28 VDC 2 general purpose output relays, form C, 2 A 28 VDC (2 additional output relays available when using PRO22ENC3 enclosure) Alarm Input Properties Inputs Circuit Type PRO2200 Series Dual Reader Module (PRO22R2) Inputs may be assigned to door related functions or general purpose I/O Circuit type - normally open, normally closed, non-supervised, supervised (with standard 1K or custom end-of-line resistance 200-10K) Line Conditioning Line conditioning - programmable sensitivity and hold time Output Control Properties Outputs Outputs may be assigned to door related functions or general purpose I/O Relay Rating The 5 A relay(s) are rated to handle the inductive loads of door locking devices Configurable Configurable as fail-secure (energise to activate) or fail-safe (de-energise to activate) Pulse Time 1-32,400 seconds, 1-255 for door relays RS485 Port RS485 port, 1,250m total bus length Default Speed 38.4 Kbps I/O Modules PRO2200 Series 16 Relay Output Module (PRO22OUT) Module Specifications Alarm Inputs Alarm Inputs Output Relays PRO2200 Series 16 Alarm Input Module (PRO22IN) 2 dedicated alarm inputs for tamper detection and power loss (tile-mounted only) N/A 16 general purpose inputs with programmable circuit type 12 general purpose output relays, form C, 2 A 30 VDC (four additional are available when using PRO22ENC3 enclosure) 1 general purpose, form C, 2 A 30 VDC relay (one additional is available when using PRO22ENC3 enclosure) Output Control Properties Outputs All 16 relay outputs (mounted in PRO22ENC3) or 12 relay outputs (in PRO22ENC1 and PRO22ENC2) are available for general purpose I/O Both relay outputs are available for general purpose I/O The 2 A relays are rated to handle dry circuit logic Both relay outputs are rated to handle dry circuit logic Dry Circuit Logic Pulse Time Configurable 1-32,400 seconds Configurable as fail-secure (energise to activate) or fail-safe (de-energise to activate) N/A Alarm Input Properties Inputs N/A All 16 inputs may be assigned to door related functions or general purpose I/O Circuit Type N/A Circuit type - normally open, normally closed, non-supervised, supervised (with correct EOL) Line Conditioning N/A Line conditioning - programmable sensitivity and hold time Communication Features Measurements Default Speed RS485 port, 1250m total bus length per port 38.4 Kbps T Y P I C A L S Y S T E M C O N F I G U R AT I O N PRO22ENC1 and PRO22ENC2 Module Reader Inputs Outputs PRO22R1 1 N/A PRO22R2 2 6 PRO22OUT 0 PRO22IN 0 PRO22ENC3 Inputs Outputs N/A 2 2 4 10** 6 0 12 2** 16 16 1 18** 2 **Two are used to monitor Power and Tamper PRO22ENC1 and PRO22ENC2=9 Board Capacity / PRO22ENC3=2 Board Capacity PRO2200 Professional Modular Access Control Hardware ORDERING PRO2200 Controllers PRO2200 High Density Enclosures and Accessories PRO22IC PRO2200 Intelligent Controller PRO22ENC1 PRO22R1 PRO2200 Single Reader Module supply, main controller and up to eight modules. PRO22R2 PRO2200 Dual Reader Module Power supply and battery not included PRO22OUT PRO2200 16* Relay Output Module PRO22IN PRO2200 16 Alarm Input Module PRO22ENC2 modules. Power supply and battery not included Ethernet daughter board for TCP/IP PRO22E1PSE communication for PRO22IC PCI3 19" Rack-mount, high-density enclosure for power supply, main controller and up to eight Communication Devices PRO22EN Wall-mount, high-density enclosure for power 110V/240VAC - 12VDC /4 A rack-mounted power supply with battery backup RS232 to RS485 single port converter PRO22DCC PRO2200 power/communication daisy chain harness PRO2200 Remote Enclosure and Accessories PRO22ENC3 Wall-mount enclosure with battery for two modules. Power supply not included PSX220 * Only 12 relay outputs are available when using the PRO22ENC1 and PRO22ENC2 enclosures For more information, visit www.honeywell.com/security/uk Honeywell Security Group Charles Avenue Burgess Hill West Sussex RH15 9UF Tel: 08448 006 890 www.honeywell.com HAS-PRO2200-01-UK(0411)DS-E April 2011 © 2011 Honeywell International Inc. 240VAC / 16VAC transformer