For more information, please visit the product page. date 05/14/2014 page 1 of 6 SERIES: PQM3-M │ DESCRIPTION: DC-DC CONVERTER FEATURES • • • • • • • • • • 3 W isolated output smaller package single regulated output 1,500 Vdc isolation continuous short circuit temperature range (-40~105°C) high efficiency at light load high power density high vibration tolerance efficiency up to 81% MODEL input voltage output voltage output current output power ripple and noise1 efficiency typ (Vdc) range (Vdc) (Vdc) min (mA) max (mA) max (W) max (mVp-p) typ (%) PQM3-D12-S5-M 12 9~18 5 30 600 3 60 75 PQM3-D12-S12-M 12 9~18 12 12 250 3 60 77 PQM3-D12-S15-M 12 9~18 15 10 200 3 60 79 PQM3-D24-S5-M 24 18~36 5 30 600 3 60 76 PQM3-D24-S12-M 24 18~36 12 12 250 3 60 81 PQM3-D24-S15-M 24 18~36 15 10 200 3 60 80 PQM3-D48-S5-M 48 36~75 5 30 600 3 60 77 PQM3-D48-S12-M 48 36~75 12 12 250 3 60 80 PQM3-D48-S15-M 48 36~75 15 10 200 3 60 80 Notes: 1. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 µF ceramic and 10 µF electrolytic capacitors on the output. PART NUMBER KEY PQM3 - DXX - SXX - M - X Base Number Input Voltage Output Voltage cui.com Packaging Style SMT Package Options "blank" = standard TR = Tape & Reel For more information, please visit the product page. CUI Inc │ SERIES: PQM3-M │ DESCRIPTION: DC-DC CONVERTER date 05/14/2014 │ page 2 of 6 INPUT parameter conditions/description min typ max units operating input voltage 12 V input models 24 V input models 48 V input models 9 18 36 12 24 48 18 36 75 Vdc Vdc Vdc start-up voltage 12 V input models 24 V input models 48 V input models 4.5 11 24 8 16 33 9 18 36 Vdc Vdc Vdc surge voltage for maximum of 1 second 12 V input models 24 V input models 48 V input models -0.7 -0.7 -0.7 25 50 100 Vdc Vdc Vdc filter pi filter OUTPUT parameter conditions/description typ max units line regulation full load, input voltage from low to high min ±0.2 ±0.4 % load regulation 5% to 100% load ±0.2 ±0.75 % voltage accuracy 5% to 100% load ±1 ±3 % 5V models no-load output voltage accuracy all other models ±1.5 ±1.5 ±5 ±3 % % switching frequency 100% load, nominal input voltage (PFM mode) 350 transient recovery time 25% load step change 0.5 1 ms transient response deviation 25% load step change ±2 ±5 % temperature coeffecient 100% load ±0.02 ±0.03 %/°C min typ max units min typ max units KHz PROTECTIONS parameter conditions/description short circuit protection continuous, automatic recovery SAFETY AND COMPLIANCE parameter conditions/description isolation voltage for 1 minute at 1 mA max. 1,500 Vdc isolation resistance at 500 Vdc 1,000 MΩ conducted emissions CISPR22/EN55022, class B (external circuit required, see Figure 1-b) radiated emissions CISPR22/EN55022, class B (external circuit required, see Figure 1-b) ESD IEC/EN61000-4-2, class B, contact ± 4kV radiated immunity IEC/EN61000-4-3, class A, 10V/m EFT/burst IEC/EN61000-4-4, class B, ± 2kV (external circuit required, see Figure 1-a) surge IEC/EN61000-4-5, class B, ± 2kV (external circuit required, see Figure 1-a) conducted immunity IEC/EN61000-4-6, class A, 3 Vr.m.s voltage dips & interruptions IEC/EN61000-4-29, class B, 0%-70% MTBF as per MIL-HDBK-217F @ 25°C RoHS 2011/65/EU 1,000,000 cui.com hours For more information, please visit the product page. CUI Inc │ SERIES: PQM3-M │ DESCRIPTION: DC-DC CONVERTER date 05/14/2014 │ page 3 of 6 ENVIRONMENTAL parameter conditions/description min max units operating temperature see derating curve -40 105 °C -55 125 °C 95 % storage temperature storage humidity non-condensing temperature rise at full load, Ta=25°C typ 25 °C SOLDERABILITY parameter conditions/description hand soldering reflow soldering min typ max units 1.5 mm from case for 10 seconds 300 °C see reflow soldering profile 240 °C max units MECHANICAL parameter conditions/description dimensions 23.86 x 13.70 x 8.00 (0.939 x 0.539 x 0.315 inch) min case material epoxy resin (UL94-V0) typ mm weight 5.2 g MECHANICAL DRAWING units: mm[inch] tolerance: ±0.25[±0.010] pin section tolerance: ±0.10[±0.004] 23.86±0.50[0.939±0.020] 16 2.54[0.100] 10 9 1 7 8 13.70[0.539] 15.24[0.600] A A 1.34 [0.053] Side View PIN CONNECTIONS 1.02[0.040] 0.50[0.020] Front View 1 7 PCB Layout Top View 8 2.50 [0.098] 10 9 19.42 [0.765] 16 Grid Size: 2.54mm x 2.54mm 1.20[0.047] cui.com 0.25[0.010] 5 max 18.10 [0.713] 8.00 [0.315] 7.50 [0.295] Top View 18.10±0.40[0.713±0.0016] max 3.34[0.131] PIN Function 1 GND 7 NC 8 NC 9 +Vo 10 0V 16 Vin For more information, please visit the product page. CUI Inc │ SERIES: PQM3-M │ DESCRIPTION: DC-DC CONVERTER date 05/14/2014 │ page 4 of 6 DERATING CURVES Temperature Derating Curve Reflow Soldering Profile 250 Peak.Temp 240 C 10 Sec Max 60 Sec Max (>220 C) Load (%) Tem per at ur e ( C ) 100 220 C 200 150 100 80 60 Safe operating area 40 20 50 -40 0 -20 0 Tim e (s ec . ) 20 40 60 85 Ambient Temperature (°C) EMC RECOMMENDED CIRCUIT Vi n FU SE LD M1 LD M2 Vi n + Figure 1 MO V GND TVS C0 C1 (a) EUT C2 (b) +Vo L O AD 0V GND Recommended external circuit components Vin (Vdc) FUSE Table 1 12 24 48 choose according to practical input current MOV -- 10D560 10D101 LDM1 -- 56μH 56μH TVS SMCJ28A SMCJ48A SMCJ90A C0 680μF/25V 120μF/50V 120μF/100V LDM2 12μH 12μH 12μH C1 4.7μF/50V 4.7μF/50V 4.7μF/100V C2 4.7μF/50V 4.7μF/50V 4.7μF/100V TEST CONFIGURATION Figure 2 Table 2 Oscilloscope Lin Cin Lin(4.7µH) External components Current Probe DC DC Load Cin(220µF, ESR < 1.0Ω at 100 KHz) Note: Input reflected-ripple current is measured with an inductor Lin and Capacitor Cin to simulate source impedance. cui.com Lin 4.7μH Cin 220μF, ESR < 1.0Ω at 100 KHz 105 120 For more information, please visit the product page. CUI Inc │ SERIES: PQM3-M │ DESCRIPTION: DC-DC CONVERTER date 05/14/2014 │ page 5 of 6 APPLICATION NOTES 1. Output load requirement To ensure this module can operate efficiently and reliably, the minimum output load may not be less than 5% of the full load during operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load. 2. Recommended circuit This series has been tested according to the following recommended testing circuit before leaving the factory. This series should be tested under load (see Figure 3 & Table 3). If you want to further decrease the input/output ripple, you can increase the capacitance accordingly or choose capacitors with low ESR. However, the capacitance of the output filter capacitor must be appropriate. If the capacitance is too high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the maximum capacitance must be less than the maximum capacitive load (see Table 4). +Vo Vin Figure 3 C in DC DC Co ut 0V GND Table 3 Vin (Vdc) Table 4 Cin (µF) Cout (µF/mA) Vout (Vdc) Max. Capacitive Load (μF) 12 100 24 10~47 10/100 5 3300 10/100 12 1800 48 10~47 10/100 15 1000 3. Input Current When it is used in an unregulated condition, make sure that the input fluctuations and ripple voltage do not exceed the module standard. Refer to Figure 4 & Table 5 for the startup current of this dc-dc module. Figure 4 Input Current(A) Table 5 Ip Input Voltage Range Vin (Vdc) Ip (mA) 12 640 24 320 48 160 Input Voltage (V) Note: 1. Minimum load shouldn't be less than 5%, otherwise ripple may increase dramatically. Operation under minimum load will not damage the converter, however, they may not meet all specifications listed. 2. Maximum capacitive load is tested at input voltage range and full load. 3. All specifications are measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified. cui.com For more information, please visit the product page. CUI Inc │ SERIES: PQM3-M │ DESCRIPTION: DC-DC CONVERTER date 05/14/2014 │ page 6 of 6 REVISION HISTORY rev. description date 1.0 initial release 03/19/2013 1.01 updated emc recommendations, updated spec 05/14/2014 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.