Download

1000 mA DC-DC Step Down Converter P78BS-Series
●
●
●
●
●
●
●
●
Non isolated
10 Pin SMD package
Function compatible with 78xx linear regulator
Efficiency up to 93 %
Operating temperature range -40...+85 °C
Continuous short circuit protected
Thermal shut down
Adjustable output voltage
Model guide
Type
P78BS1R5
P78BS1R8
P78BS2R5
P78BS3R3
P78BS05
P78BS6R5
Input voltage
Range
Nominal
[VDC]
4.75..15
4.75..15
5..18
5..18
7..18
8.5..18
[VDC]
12
12
12
12
12
12
Output
Voltage
[VDC]
1.5
1.8
2.5
3.3
5.0
6.5
Adjust trim
range
[VDC]
fixed
1.5…3.6
1.5…3.9
1.8…5.5
2.5…8
fixed
Current
[mA]
1000
1000
1000
1000
1000
1000
Capacitive
load max.
[µF]
1000
1000
1000
1000
1000
1000
Efficiency
@ Vin min.
@ Vin max.
[%]
76
79
83
84
90
93
[%]
74
77
81
84
88
91
Specifications
Output
Voltage accuracy
Input voltage regulation
Load regulation
Dynamic load stability
Temperature coefficient
Ripple (at 20 MHz BW)
Noise (at 20 MHz BW)
Short circuit protection
(hiccup mode)
Thermal shutdown
Output current limit
Transient peak deviation
Transient recovery time
Input
Filter
Short circuit input power
Quiescent current
No load input power consumption
ON control threshold
OFF control threshold
ON / OFF control current
Shut down quiescent current
± 3 %, max.
± 0.5 %, max.
± 1 % @ load change 10..100 %
± 75 mV @ load 10..100 %
± 0.02 % / °C
35 mVp-p, max.
15 mVp-p, max.
Continuous, automatic recovery
150 °C, typ. internal temp.
1.8 A, typ.
± 100 mV, max. @ load change 10..100 %
100 µs, max. @ load change 10..100 %
Capacitive, 1 µF
1.8 W, max.
15 mA, typ.
54 mW, max.
1.2 V min., 6 V max. or open pin 10
< 0.6 V
< 200 µA
200 µA, max.
General
Thermal shutdown
Switching frequency
Reliability calc. MTBF @
25 °C MIL-HDBK-217F
Environmental
Operating ambient temperature
Operating case temperature
Storage temperature
Derating
Storage humidity
Cooling
Physical
Dimensions
Weight
Case material
Soldering temperature
160 °C, internal junction
1.4 MHz, typ.
> 1 Mio. h
-40 °C ... +85 °C
100 °C, max.
-55 °C ... +125 °C
see diagram
Up to 95%, non condensing
Free air convection
SMD10, 15.24 x 8.5 x 7.25 mm
2.3 g
Plastic UL94-V0
See soldering profile
Page 1 of 6
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Hochstrasse 355
CH-8200 Schaffhausen
Tel.: 052 647 42 00
E-Mail: [email protected]
1000 mA DC-DC Step Down Converter P78BS-Series
Standard application circuit
5
1
P78BS
+Vin
+Vout
Rtd
7, 9
10
C1
10 µF
Ceramic
6
Open
ONstate
Rtu
470
pF
C2
100 µF
GND
GND
1.
2.
3.
C1,C2 are require and should be placed close to the pins of the converter, with shortest possible traces.
Do not connect the converter parallel or a hot swap
Do not connect the converter parallel or a hot swap
Adjustment resistor values
Type
Adj. range
P78BS1R8
1.5…3.6 V
Adj. Vout [V]
Rtd [kΩ]
Rtu [kΩ]
1.5
1.8
2.5
3.0
3.3
3.6
3.9
4.5
4.9
5.0
5.1
5.5
6.0
6.5
188
-
81.4
32.2
18.6
9.5
-
P78BS2R5
1.5…3.9 V
Rtd
Rtu
[kΩ]
[kΩ]
15.4
68.6
88.7
41.3
20.1
8.0
-
P78BS3R3
1.8…5.5 V
Rtd
Rtu
[kΩ]
[kΩ]
15.4
87
339
121
51
16.6
8
6.5
5.2
1.1
-
P78BS5
2.5…6.5 V
Rtd
Rtu [kΩ]
[kΩ]
9.7
30.5
48.8
75
115
338
1835
426
58.7
16.9
3.2
Note: The above dates only are as reference, you could make corresponding adjustment with actual output when they
are at practical application.
Application circuit to reduce output ripple.
It is recommented to add a LC filter to output.
5
1
+Vin
10
C1
10 µF
GND
L 10…47µH
P78BS
7,9
+Vout
6
470
pF
C2
100µF
C3
22 µF
GND
Page 2 of 6
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Hochstrasse 355
CH-8200 Schaffhausen
Tel.: 052 647 42 00
E-Mail: [email protected]
1000 mA DC-DC Step Down Converter P78BS-Series
ON / OFF control function
The ON/OFF pin 10 provides several features for adjusting and sequencing the power supply.
An user has the flexibility of using the ON/OFF pin 10 as:
1) A digital on/off control by pulling down the ON/OFF pin with an open-drain transistor.
1
+Vin
C1
On/Off
Contr.
+Vout
C2
6
7, 9
10
5
P78BS
ON/
OFF
C3
470
pF
GND
GND
EMC Specification
EMI
CE
RE
ESD
EMS
RS
EFT
Surge
CS
Voltage dips,
short and
interruptions
immunity
CISPR22 / EN55022
CISPR22 / EN55022
CISPR22 / EN55022
IEC / EN61000-4-2
IEC / EN61000-4-2
IEC / EN61000-4-3
IEC / EN61000-4-4
IEC / EN61000-4-5
IEC / EN61000-4-6
Contact ±6 kV
Air ±8 kV
10 V/m
±2 kV
±2 kV
3 V rms
Class A,
Class B,
Class A,
perf. Criteria B
perf. Criteria B
perf. Criteria A
perf. Criteria B,
perf. Criteria B,
perf. Criteria A
IEC / EN61000-4-29
0…70 %
perf. Criteria B
without external circuit
with external filter circuit 2
with external filter circuit 2
with ext. filter circuit 1
with ext. filter circuit 1
EMC Application circuit
82 µH
33 µH
+Vin
P78BS
1
TVS
SMC36A
MOV
10D560
120 µF
+
4.7 µF
5
10
7, 9
6
Load
470 pF
GND
Circuit 1
Circuit 2
Test circuit for output ripple & noise, start up time and load tansient response
25.4
+Vin
P78BS
1
10
7, 9
C1
12.7
Unit:mm
1µ
+Vout
10 µ
Cer.
Cer.
5
6
C2
470
pF
12.7
C3
Oscilloscope
measure points
GND
GND
Page 3 of 6
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Hochstrasse 355
CH-8200 Schaffhausen
Tel.: 052 647 42 00
E-Mail: [email protected]
1000 mA DC-DC Step Down Converter P78BS-Series
Page 4 of 6
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Hochstrasse 355
CH-8200 Schaffhausen
Tel.: 052 647 42 00
E-Mail: [email protected]
1000 mA DC-DC Step Down Converter P78BS-Series
Page 5 of 6
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Hochstrasse 355
CH-8200 Schaffhausen
Tel.: 052 647 42 00
E-Mail: [email protected]
1000 mA DC-DC Step Down Converter P78BS-Series
Dimensions
Pin
1
5
6
7
9
10
Connections
+V Input
+V Output
Trim input
GND
GND
ON/OFF control
PHI-CON is a trademark of HY-LINE Holding GmbH.
Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions for
use carefully before using!
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without
the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and
whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably
expected to result in significant injury to the user. Rev: 2.16 f
Page 6 of 6
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Hochstrasse 355
CH-8200 Schaffhausen
Tel.: 052 647 42 00
E-Mail: [email protected]