For more information, please visit the product page. date 08/23/2012 page 1 of 6 SERIES: VSCP-800 │ DESCRIPTION: AC-DC POWER SUPPLY RoHS (Vdc) VSCP-800-09 9 VSCP-800-12 12 VSCP-800-15 15 VSCP-800-18 18 VSCP-800-36 ripple and noise3 efficiency max (A) max (W) max (mVp-p) typ (%) 44 / 88 800 90 83 33 / 66 800 120 84 26 / 53 800 150 85 22 / 44.4 800 180 85 24 16 / 33 800 240 88 36 11 / 22.2 800 360 88 48 8 / 16 800 480 89 6 / 13 800 600 90 O VSCP-800-48 60 1. output voltage is measured at output power connector 2. maximum current is measured at 100~120 V input / 200~240 V input 3. ripple and noise is measured from 10 KHz to 20 MHz at output terminals with 0.1 μF ceramic capacitor and a 22 μF electrolytic capacitor in parallel IS C Notes: output power N VSCP-800-24 VSCP-800-60 output current2 TI output voltage1 MODEL U up to 800 W continuous power universal input (90~260 Vac / 130~370 Vdc) single output from 9~60 V programmable output voltage active power correction (98%) current sharing capable power good, remote sense, remote on/off control built-in DC fan over load, over voltage, over temperature, and short circuit protections ctions UL and TUV safety approvals efficiency up to 90% N • • • • • • • • • • • ED FEATURES PART NUMBER KEY VSCP-800 - XX Base Number D Output Voltage cui.com For more information, please visit the product page. CUI Inc │ SERIES: VSCP-800 │ DESCRIPTION: AC-DC POWER SUPPLY date 08/23/2012 │ page 2 of 6 INPUT conditions/description min max units voltage 100 ~ 120 / 200 ~ 240 Vac (see derating curve) 130 ~ 185 / 260 ~ 370 Vdc (see derating curve) 100 130 240 370 Vac Vdc 47 63 Hz 4.5 A 60 A frequency current at 90-264 Vac, full load inrush current peak measured at 230 Vac, cold start power factor correction at 230 Vac, full load 0.98 OUTPUT parameter typ ED parameter conditions/description min typ max 0 ~ 50°C 230 Vac at full load adjustability adjustable with built-in trim pot, 25 ~ 100% adjustment by 1 ~ 5 Vdc external control programming output voltage programmable through external 0 ~ 5 V control voltage on VCI. Control voltage can also be obtained from VCO via a 470 KΩ pot. see application diagrams remote sense Designated as (VS+) and (VS-). Total voltage compensation from cable losses with respect to the main output. remote inhibit Designated as (INH), requires a low signal to inhibit the output. current sharing Designated as (PAR), use in parallel for forced current sharing function. U temperature coefficient hold-up time 25 N conditions/description N parameter over voltage protection %/°C 12 ±7.5 TI PROTECTION min typ 110 ms % 100 % max units 135 % current limiting 3 times with auto recovery before shutdown over current protection4 4. Protection mode sends a pulse, waits 1.5 seconds, sends second pulse, waits 3 seconds, sends third pulse, waits 5 seconds. If overload is still present, the unit will shutdown. O Notes: ±0.04 units SAFETY & COMPLIANCE parameter conditions/description min typ max units 3.5 mA max units TUV EN60950, UL/cUL 1950 IS C safety approvals EMI/EMC EN 55022, EN 61000-4-(2,3,4,5,6,8,11), EN 61000-3-(2,3), ENV50204 leakage current at 240 Vac RoHS compliant yes ENVIRONMENTAL parameter conditions/description min 0 50 °C storage temperature -20 85 °C operating humidity 20 90 % storage humidity 10 95 % 10 200 Hz D operating temperature typ vibration for 60 minutes, each axis cui.com For more information, please visit the product page. CUI Inc │ SERIES: VSCP-800 │ DESCRIPTION: AC-DC POWER SUPPLY date 08/23/2012 │ page 3 of 6 Load (%) ≈ 100 ED DERATING CURVES 80 60 50 40 ≈ U 20 -25 0 10 20 30 40 50 60 70 N Ambient Temperature (°C) parameter TI MECHANICAL conditions/description weight O N 11.42 x 4.72 x 2.66 inches (290 x 120 x 67.5mm) D IS C enclosure min cui.com typ 4.5 max units Kg mm For more information, please visit the product page. CUI Inc │ SERIES: VSCP-800 │ DESCRIPTION: AC-DC POWER SUPPLY date 08/23/2012 │ page 4 of 6 MECHANICAL DRAWING ED tolerance: ±1.0mm unless otherwise specified 290.00 11.417 67.50 26.50 1.043 N U 120.00 4.724 #6-32 (4 PLCS) 38.00 1.496 M3(NUT)X3H (4 PLCS) O 251.00 9.882 89.00 3.504 IS C D 200.00 7.874 N M3(NUT)X3H (4 PLCS) 25.00 0.984 TI 200.00 7.874 LOGIC CONNECTOR 1 VS+ output voltage remote sense+ 2 VS- output voltage remote sense- 3 VCI command input voltage for output programming 4 VCO 5~10 Vdc reference for output programming 5 FAL power failure detected 6 PG power good signal 7 PAR current sharing / parallel function 8 GND return / output ground 9 INH inhibit / remote on-off cui.com For more information, please visit the product page. CUI Inc │ SERIES: VSCP-800 │ DESCRIPTION: AC-DC POWER SUPPLY date 08/23/2012 │ page 5 of 6 D IS C O N TI N U ED LOGIC CONNECTIONS cui.com For more information, please visit the product page. CUI Inc │ SERIES: VSCP-800 │ DESCRIPTION: AC-DC POWER SUPPLY date 08/23/2012 │ page 6 of 6 REVISION HISTORY description date 08/20/2007 1.0 initial release 1.01 new template applied 1.02 V-Infinity branding removed ED rev. 12/22/2011 08/23/2012 D IS C O N TI N U The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.