MURATA NTV0509MC

NTV Series
www.murata-ps.com
3kVDC Isolated 1W Dual Output SM DC/DC Converters
SELECTION GUIDE
Order Code
Nominal
Input
Voltage
V
NTV0505MC
NTV0509MC
NTV0512MC
NTV0515MC
NTV1205MC
NTV1209MC
NTV1212MC
NTV1215MC
5
5
5
5
12
12
12
12
1
FEATURES
„
RoHS compliant
„
Efficiency up to 82%
„
Wide temperature performance at full
1 Watt load, –40°C to 85°C
„
UL 94V-0 package material
V
mA
Input
Current at
Rated Load
mA
±5
±9
±12
±15
±5
±9
±12
±15
±100
±55
±42
±33
±100
±55
±42
±33
282
260
253
250
114
105
104
101
Output
Voltage
Output
Current
Isolation
MTTF2
Capacitance
Efficiency
%
pF
kHrs
71
77
79
80
73
79
80
82
33
38
44
43
50
72
89
100
1697
682
343
188
559
375
243
154
When operated with additional external load capacitance the rise time of the input voltage will determine the maximum external
capacitance value for guaranteed start up. The slower the rise time of the input voltage the greater the maximum value of the
additional external capacitance for reliable start up.
„
Footprint over pins 1.64cm2
INPUT CHARACTERISTICS
„
Lead frame technology
Parameter
Conditions
Min.
Typ.
Max.
„
Dual isolated output
Voltage range
Continuous operation, 5V input types
Continuous operation, 12V input types
4.5
10.8
„
5V & 12V input
Reflected ripple current
5
12
41
5.5
13.2
47
mA p-p
Typ.
Max.
Units
1.0
W
1.2
12
8.0
8.5
7.0
75
65
60
60
%/%
„
5V, 9V, 12V and 15V output
OUTPUT CHARACTERISTICS
„
Internal SMD construction
Parameter
Conditions
Rated Power
Voltage Set Point Accuracy
Line regulation
TA=-40°C to 85°C
See tolerance envelope
High VIN to low VIN
10% load to rated load, 5V output types
10% load to rated load, 9V output types
10% load to rated load, 12V output types
10% load to rated load, 15V output types
BW=DC to 20MHz, 5V output types
BW=DC to 20MHz, 9V output types
BW=DC to 20MHz, 12V output types
BW=DC to 20MHz, 15V output types
„
Toroidal magnetics
„
Plastic encapsulated
„
3kVDC isolation (1 minute)
„
MTTF up to 1.7 million hours
Load Regulation3
„
Power density 1.36W/cm3
„
No heatsink required
„
Custom solutions available
„
Multi layer ceramic capacitors
Ripple and Noise
Min.
1.0
10
6.5
6.0
6.0
50
40
40
40
Units
V
%
mV p-p
ABSOLUTE MAXIMUM RATINGS
PRODUCT OVERVIEW
The NTV series of 3kV isolation miniature
surface mounted DC/DC converters employ
leadframe technology and transfer moulding
techniques to bring all of the benefits of IC style
packaging to hybrid circuitry. The co-planarity of the pin positions is based upon IEC
191-6:1990. The devices are suitable for all
applications where high volume production is
envisaged.
Short-circuit protection4
Lead temperature 1.5mm from case for 10 seconds
Internal power dissipation
Input voltage VIN, NTV05 types
Input voltage VIN, NTV12 types
1 second
300°C
550mW
7V
15V
1. If components are required in tape and reel format suffix order code code with -R, e.g. NTV0505MC-R.
2. Calculated using MIL-HDBK-217F with nominal input voltage at full load.
3. 12V input types have typically 3% less load regulation change.
4. Supply voltage must be disconnected at the end of the short circuit duration.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_NTV.E08 Page 1 of 4
NTV Series
3kVDC Isolated 1W Dual Output SM DC/DC Converters
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
Isolation test voltage
Resistance
Flash tested for 1 minute
Viso= 1000VDC
3000
10
Typ.
Parameter
Conditions
Min.
Switching frequency
5V input types
12V input types
Max.
Units
VDC
GΩ
GENERAL CHARACTERISTICS
Typ.
Max.
115
120
Units
kHz
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Min.
Specification
Storage
All output types
-40
-55
Case temperature above ambient
Cooling
°C
TOLERANCE ENVELOPE
+10%
+5%
VNOM
85°C
Output Voltage
Output Power (W)
0
-40
Units
33
25
1.5
0.5
Max.
85
125
5V output types
All other output types
Free air convection
TEMPERATURE DERATING GRAPH
1.0
Typ.
Safe Operating Area
100
50
0
Ambient Temperature (°C)
150
Typical
L
oad Line
+2.5%
-2.5%
-7.5%
10
75
50
25
Output Load Current (%)
100
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NTV series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 3kVDC for 1 minute.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
For a part holding no specific agency approvals, such as the NTV series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or
60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part
could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must
be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to
safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The NTV series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
www.murata-ps.com/support
KDC_NTV.E08 Page 2 of 4
NTV Series
3kVDC Isolated 1W Dual Output SM DC/DC Converters
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
PIN CONNECTIONS
15.24
(0.600)
12.70
(0.500)
22
11.20
10.40
(0.441)
(0.409)
20
7.70
(0.303)
18
12
14
NTV0505MC
P
XYYWW
1
3
5
9
1.50 (0.059)
1.20 (0.47)
11
10 PINS
0.2 (0.008)
0.65 (0.026)
0.55 (0.022)
2.54 (0.1)
±5.00°
S
2.10
(0.083)
6.60 (0.260) 6.35 (0.250)
5.95 (0.234) 5.85 (0.230)
0.5 (0.020)
REFERENCE
PLANE
DETAIL A
0.25 (0.010)
0.10 (0.004)
S
Pin
Function
1
-VIN
3
+VIN
5
NA
9
OV
11
-VOUT
12
NA
14
+VOUT
18
NA
20
NA
22
NA
SEATING
PLANE
NA - Not available for electrical connection.
10 PINS
0.1 (0.004) S
2.79 (0.11) MAX
1.875 (0.074) MAX
0.30 (0.012)
0.20 (0.008)
Weight: 1.53g
All dimensions in mm ±0.25mm (inches ±0.01). All pins on a 2.54 (0.1) pitch.
TUBE OUTLINE DIMENSIONS
RECOMMENDED FOOTPRINT DETAILS
12.70
(0.5)
0.60±0.15 (0.024±0.006)
2.10 (0.083)
2.00
(0.079)
9.40 (0.370)
14.35 (0.565)
9.70
(0.382)
6.70 (0.264)
2.54 (0.1)
1.00 (0.040) MIN
Unless otherwise stated all dimensions in mm±0.5 (inches ±0.02).
Tube length : 475±2.0 (18.70±0.07).
Tube Quantity : 25
RoHS COMPLIANCE, MSL AND PSL INFORMATION
This series is compatible with RoHS soldering systems and is also backward compatible with Sn/Pb soldering systems.
The NTV series has a process, moisture, and reflow sensitivity classification of MSL1 PSL R7F as defined in J-STD-020
and J-STD-075. This translates to: MSL1 = unlimited floor life, PSL R7F = Peak reflow temperature 245°C with a
limitation on the time above liquidus (217°C) which for this series is 60sec max. The pin termination finish on this product
series is Gold with a plating thickness of 0.05 microns minimum.
For further information please visit www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_NTV.E08 Page 3 of 4
NTV Series
3kVDC Isolated 1W Dual Output SM DC/DC Converters
TAPE & REEL SPECIFICATIONS
REEL OUTLINE DIMENSIONS
TAPE OUTLINE DIMENSIONS
330
(12.99) MAX
15.75
(0.62)
0.60 (0.02) MAX
100
Ø (3.94) MIN
+0.10 (+0.004)
-0.00 (-0.00)
DIRECTION OF UNREELING
13.00±0.25
Ø (0.51±0.009)
2.00
(0.08)
30.40 (1.20) MAX
+2.00
24.40 (0.96)(0.08) (AT HUB SECTION)
-0.00
(0.00)
Ø1.50 (0.06)
16.00 (0.63)
11.60
(0.46)
4.00
(0.16)
6.60
(0.26)
1.75 (0.07)
11.50
(0.45)
24.00±0.30
(0.94±0.04)
REEL PACKAGING DETAILS
XYYWW
NTV0505MC
XYYWW
NTV0505MC
XYYWW
NTV0505MC
Product Orientation
Pin 1, located nearest to
carrier drive sprocket.
TRAILER SECTION
160 (6.30) MIN
GOODS ENCLOSURE
SECTION
CARRIER TAPE START
100 (3.94) MIN
LEADER SECTION
400 (15.75) MIN
Reel Quantity : 500
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2012 Murata Power Solutions, Inc.
www.murata-ps.com/support
KDC_NTV.E08 Page 4 of 4