IR 501T/IR 501UT Framing FEBRUARY, 2015 EC 97911-073 FEATURES HURRICANE RESISTANT PRODUCT Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Features • IR 501T/IR 501UT is 5" (127) deep and has a 2-3/4" (69.9) sightline {Expansion mullions have a 3" (76.2) sightline} • Screw Spline fabrication • IR 501T Single IsoLockTM lanced pour and debridge thermal break • IR 501UT Dual IsolockTM lanced pour and debridge thermal break • Center glazed • Outside glazed •PermanodicTM anodized finishes in seven choices • Painted finishes in standard and custom choices Optional Features • • • • • Integrated entrance framing 350 IR/500 IR - single or pairs of entrances Strap anchor at head and jamb Acoustical rating per AAMA 1801 and ASTM E 1425 Project specific U-Factor (see thermal charts) • • • • Impact resistant Storefront, ribbon window or punched opening Low to mid-rise Single span © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Product Applications For specific product applications, Consult your Kawneer representative. kawneer.com ADMC093 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. IR 501T/IR 501UT Framing BLANK PAGE ADMC093 kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 FEBRUARY, 2015 EC 97911-073 HURRICANE RESISTANT PRODUCT FEBRUARY, 2015 IR 501T/IR 501UT Framing EC 97911-073 3 INDEX BASIC FRAMING DETAILS.................................................................. 4 MISCELLANEOUS DETAILS............................................................... 5 STRAP ANCHOR DETAILS................................................................. 6 CORNER DETAILS............................................................................... 7 ENTRANCE FRAMING......................................................................... 8 GLASSvent TM WINDOW DETAILS ...................................................... 9 WINDLOAD CHARTS ................................................................... 10-17 DEADLOAD CHARTS........................................................................ 18 THERMAL CHARTS...................................................................... 19-25 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. The following metric (SI) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. HURRICANE RESISTANT PRODUCT Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADMC093 IR 501T/IR 501UT Framing 4 FEBRUARY, 2015 EC 97911-073 BASIC FRAMING DETAILS HURRICANE RESISTANT PRODUCT SCALE 3" = 1'-0" 1 5 2 IR 501UT DUAL IsoLockTM THERMAL BREAK ELEVATION IS NUMBER KEYED TO DETAILS 1-5/16" INFILL (DRY GLAZED) 1-5/16" INFILL (WET GLAZED) 575UT514 [575T514] 575UT514 [575T514] 575531 2-3/4" (69.9) 4 JAMB 5 VERTICAL 5" (127.4) 2-3/4" (69.9) 2-3/4" (69.9) 4 JAMB 5 VERTICAL THERMAL FILLER 1 HEAD 2-3/4" (69.9) 1 HEAD 3/8" (9.5) 575532 3/8" (9.5) 2-3/4" (69.9) 3/8" (9.5) 3/8" (9.5) 575UT500 [575T500] 575532 THERMAL FILLER 2-3/4" (69.9) 575UT500 [575T500] THERMAL FILLER 5" (127.0) 5" (127.4) 5" (127.0) THERMAL FILLER 575531 575UT501 [575T501] 575UT501 [575T501] 5" (127.4) 5" (127.4) 2 HORIZONTAL 2-3/4" (69.9) 3/8" (9.5) 575UT513 [575T513] 3 SILL 575UT537 [575T537] 2-15/32" (63.1) ADMC093 575504 575UT511 [575T511] 575504 575UT513 [575T513] 1/2" (12.7) 2-3/4" (69.9) 3 SILL 1/2" (12.7) 2-3/4" (69.9) 575504 3/8" (9.5) 2 HORIZONTAL 575UT511 [575T511] 2-3/4" (69.9) 575504 575UT537 [575T537] 2-15/32" (63.1) kawneer.com © Kawneer Company, Inc., 2014 3 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. IR 501T Single IsoLockTM THERMAL BREAK IR 501T/IR 501UT Framing FEBRUARY, 2015 EC 97911-073 MISCELLANEOUS DETAILS HURRICANE RESISTANT PRODUCT SCALE 3" = 1'-0" 1-5/16" INFILL (DRY GLAZED) 3/8" (9.5) 3/8" (9.5) THERMAL FILLER 2-3/4" (69.9) 2-3/4" (69.9) THERMAL FILLER 575504 575504 575UT503 [575T503] 575UT503 [575T503] 5" (126.6) 5" (126.6) OPTIONAL HEAD WITH STOP 575T510 OPTIONAL HEAD WITH STOP 575T509 575T510 1/4" (6.4) 575T509 1/4" (6.4) 3" (76.2) 3" (76.2) EXPANSION MULLION EXPANSION MULLION 5" (127.0) 575UT516 [575T516] 5" (127.0) 575UT516 [575T516] © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1-5/16" INFILL (WET GLAZED) 575UT515 [575T515] 575UT515 [575T515] 5" (127.0) 5" (127.0) 5" x 5" MULLION kawneer.com 5" x 5" MULLION ADMC093 5 IR 501T/IR 501UT Framing FEBRUARY, 2015 STRAP ANCHOR DETAILS EC 97911-073 HURRICANE RESISTANT PRODUCT SCALE 3" = 1'-0" STRAP ANCHOR 2-3/4" (69.9) 2-3/4" (69.9) 3/8" (9.5) 3/8" (9.5) STRAP ANCHOR 575UT501 [575T501] 575UT501 [575T501] 5" (127.0) 6-1/2" (165.1) 7-7/8" (200.0) 5" (127.0) 6-1/2" (165.1) 7-7/8" (200.0) HEAD HEAD 3/8" (9.5) STRAP ANCHOR 575504 575UT503 [575T503] OPTIONAL HEAD WITH STOP OPTIONAL HEAD WITH STOP STRAP ANCHOR 5" (127.0) 6-1/2" (165.1) 7-7/8" (200.0) 5" (127.0) 6-1/2" (165.1) 7-7/8" (200.0) 5" (127.0) 6-1/2" (165.1) 7-7/8" (200.0) 5" (127.0) 6-1/2" (165.1) 7-7/8" (200.0) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 575UT503 [575T503] STRAP ANCHOR 575UT500 [575T500] 575UT500 [575T500] 2-3/4" (69.9) 3/8" (9.5) JAMB 2-3/4" (69.9) JAMB ADMC093 kawneer.com © Kawneer Company, Inc., 2014 2-3/4" (69.9) 3/8" (9.5) STRAP ANCHOR 575504 3/8" (9.5) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1-5/16" INFILL (DRY GLAZED) 1-5/16" INFILL (WET GLAZED) 2-3/4" (69.9) 6 IR 501T/IR 501UT Framing FEBRUARY, 2015 EC 97911-073 7 CORNER DETAILS HURRICANE RESISTANT PRODUCT SCALE 3" = 1'-0" 1-5/16" INFILL (DRY GLAZED) 575UT536 [575T536] 5" (127.0) 5" (127.0) 575UT536 [575T536] 575UT516 [575T516] 575UT516 [575T516] 5" (127.0) 5" (127.0) 575UT535 [575T535] 5" (127.0) 5" (127.0) 575UT535 [575T535] 575UT515 [575T515] 575UT515 [575T515] 5" (127.0) 135° 135° 575UT528 [575T528] 575UT528 [575T528] 5" ) 7.0 5" ) 7.0 (12 (12 575UT534 [575T534] 3-1 /2 (88 " .9) © Kawneer Company, Inc., 2014 575UT534 [575T534] 3-1 /2 (88 " .9) /2" 3-1 ) .9 (88 575UT534 [575T534] 135° 575UT534 [575T534] 575UT528 [575T528] 5" 7.0 5" 7.0 ) ) 135° /2" 3-1 ) .9 8 ( 8 (12 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 5" (127.0) 575UT528 [575T528] 1-7 /16 " (36 .3) kawneer.com 1-7 /16 " (36 .3) ADMC093 (12 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1-5/16" INFILL (WET GLAZED) IR 501T/IR 501UT Framing 8 FEBRUARY, 2015 ENTRANCE FRAMING EC 97911-073 HURRICANE RESISTANT PRODUCT SCALE 3" = 1'-0" 2 5 4 8 7 6 4 575551 2 575135 3 THERMAL FILLER 3/8" (9.5) 7 1 2-3/4" (69.9) 1 575UT501 [575T501] 2-3/4" (69.9) 3 1 TRANSOM HEAD OPTIONAL 2-3/4" DOOR JAMB ELEVATION IS NUMBER KEYED TO DETAILS 5" (127) 575051 575051 575133 575122 575104 2-1/2" (63.5) 1-1/8" (28.6) 8 DOOR JAMB AT TRANSOM 7 DOOR JAMB AT TRANSOM 575051 2 DOOR WITH TRANSOM 3/32" (2.4) 2-1/2" (63.5) 3-1/2" (88.9) 3-1/2" (88.9) 3/32" (2.4) 6-1/2" (165.1) 575135 575135 575051 2-1/2" (63.5) 200795 6 DOOR JAMB 4 DOOR JAMB 11/16" (17.5) 069139 3-1/2" (88.9) 1/8" (3.2) 3 THRESHOLD 3-1/2" (88.9) 5 PAIR OF DOORS ADMC093 kawneer.com © Kawneer Company, Inc., 2014 1-1/8" (28.6) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2-1/2" (63.5) 3-1/2" (88.9) 575135 1/8" (3.2) 575135 2-1/2" (63.5) 575133 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. IR 501 FRAMING INCORPORATING KAWNEER 350 IR DOORS. DOOR FRAMING NON-THERMAL ONLY. SEE 350 IR ENTRANCES FOR ADDITIONAL DOOR AND ENTRANCE FRAMING OPTIONS. IR 501T/IR 501UT Framing FEBRUARY, 2015 EC 97911-073 GLASSventTM WINDOW DETAILS HURRICANE RESISTANT PRODUCT SCALE 3" = 1'-0" 575UT511 [575T511] 575504 1 575204 1 3 4 5 2 ELEVATION IS NUMBER KEYED TO DETAILS 575504 575204 Hardware: Hinge:Stainless Steel 4-Bar Lock: Hurricane Cam Handles 2 575UT537 [575T537] 575UT513 [575T513] PROJECT-OUT VERTICAL SECTION 575531 575531 575532 3 575UT514 [575T514] 575532 575UT500 [575T500] 4 NOTE: Black spacer is recommended when 1" insulating glass is used. kawneer.com THERMAL FILLER 575204 575204 575204 575UT514 [575T514] © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. PROJECT-OUT HORIZONTAL SECTION ADMC093 5 9 IR 501T/IR 501UT Framing 10 FEBRUARY, 2015 WINDLOAD CHARTS EC 97911-073 HURRICANE RESISTANT PRODUCT A = 30 PSF (1440) B = 40 PSF (1920) C = 50 PSF (2400) D = 70 PSF (3360) E = 90 PSF (4320) 575T500 WITH HORIZONTALS WIDTH IN METERS 2.0 15 WIDTH IN METERS 1.0 14 14 11 11 9 8 7 A 6 2.0 B 5 C 4 1 2 3 4 5 6 WIDTH IN FEET 7 8 B C 7 D E 2.0 5 1.0 3 2 1 2 3 4 5 6 WIDTH IN FEET 7 8 575UT500 WITHOUT HORIZONTALS ** 84" maximum vertical DLO anchored at top and bottom only. Add perimeter fasteners to increase DLO height. 2.0 16 15 WIDTH IN METERS 1.0 2.0 16 15 14 14 10 3.0 9 8 7 2.0 6 A 5 B C 4 D 1 2 3 4 5 6 WIDTH IN FEET 7 E 8 12 575UT500 WINDLOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505 HEIGHT IN FEET 11 HEIGHT IN METERS 12 4.0 13 11 10 3.0 9 A 8 B C 7 D E 6 HEIGHT IN METERS 4.0 13 HEIGHT IN FEET A 8 * 92 3/4" maximum DLO with anchors located at top and bottom of intermediate horizontals. WIDTH IN METERS 3 9 6 MAXIMUM ALLOWABLE STRESS AND DEFLECTION for 575T500 and 575UT500 8,000 PSI WITH HORIZONTALS* 9,000 PSI WITHOUT HORIZONTALS** 1/4" ALLOWABLE DEFLECTION @ JAMBS 575UT500 WITH HORIZONTALS 1.0 WINDLOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505 3.0 4 D 1.0 E 3 575T500 10 2.0 5 4 1.0 3 ADMC093 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 8 kawneer.com © Kawneer Company, Inc., 2014 3.0 HEIGHT IN FEET 12 HEIGHT IN METERS HEIGHT IN FEET 12 10 4.0 13 HEIGHT IN METERS 4.0 13 2 2.0 15 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1.0 575T500 WITHOUT HORIZONTALS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L\175 up to 13'-6" and L\240 + 1/4" above 13'-6". These curves are for mullions WITH and WITHOUT HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM (assuming full lateral buckling support) 15,152 psi (104 MPa), FORMED STEEL 30,000 P.S.I. (207 MPa), STEEL BAR 20,000 psi (138 MPa). Charted curves, in all cases, are for the limiting value. If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. IR 501T/IR 501UT Framing FEBRUARY, 2015 11 EC 97911-073 575T509 & 575T510 WITH HORIZONTALS 1.0 2.0 16 575T509 & 575T510 WITHOUT HORIZONTALS WIDTH IN METERS 1.0 15 14 14 A 10 3.0 B 9 8 C 7 2.0 6 D 5 12 575T509 / 575T510 WINDLOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505 E 4 HEIGHT IN FEET 11 HEIGHT IN METERS 12 4.0 13 A 11 B 10 C 9 3.0 D E 8 7 2.0 6 5 4 1.0 2 3 4 5 6 WIDTH IN FEET 7 3 8 © Kawneer Company, Inc., 2014 1 ADMC093 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 8 HEIGHT IN METERS 4.0 13 kawneer.com 2.0 16 15 3 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. A = 30 PSF (1440) B = 40 PSF (1920) C = 50 PSF (2400) D = 70 PSF (3360) E = 90 PSF (4320) WIDTH IN METERS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. HURRICANE RESISTANT PRODUCT IR 501T/IR 501UT Framing 12 FEBRUARY, 2015 WINDLOAD CHARTS EC 97911-073 2.0 15 WIDTH IN METERS 1.0 14 14 12 11 11 9 8 A 7 2.0 6 C 4 D 3 E 1 2 3 4 5 6 WIDTH IN FEET 7 2.0 D 2.0 E 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 8 575UT514 WITHOUT HORIZONTALS WIDTH IN METERS 1.0 2.0 16 15 15 14 14 10 3.0 9 A 8 7 B 6 2.0 C 5 D E 4 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 12 HEIGHT IN FEET 11 HEIGHT IN METERS 12 4.0 13 575UT514 WINDLOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505 11 10 A 3.0 9 B 8 C 7 D ADMC093 2.0 5 4 3 8 E 6 HEIGHT IN METERS 4.0 13 HEIGHT IN FEET C 7 3 A = 30 PSF (1440) B = 40 PSF (1920) C = 50 PSF (2400) D = 70 PSF (3360) E = 90 PSF (4320) 16 3 8 2 WIDTH IN METERS B 4 8 575UT514 WITH HORIZONTALS 1.0 9 3.0 5 WINDLOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505 1.0 A 10 6 575T514 B 5 HEIGHT IN FEET 3.0 HEIGHT IN METERS HEIGHT IN FEET 12 10 4.0 13 HEIGHT IN METERS 4.0 13 2 2.0 15 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 8 kawneer.com © Kawneer Company, Inc., 2014 WIDTH IN METERS 1.0 575T514 WITHOUT HORIZONTALS A = 30 PSF (1440) B = 40 PSF (1920) C = 50 PSF (2400) D = 70 PSF (3360) E = 90 PSF (4320) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 575T514 WITH HORIZONTALS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. HURRICANE RESISTANT PRODUCT IR 501T/IR 501UT Framing FEBRUARY, 2015 13 EC 97911-073 575T515 & 575T535 WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN METERS 2.0 1.0 15 14 11 11 3.0 9 A 8 B 7 C 6 2.0 D 5 E HEIGHT IN FEET 12 HEIGHT IN METERS 12 10 * B 8 C 7 * LOCATE FASTENER 6" FROM EACH END AND 9" O.C. 5 3.0 D E 2.0 4 3 1 2 3 4 5 6 WIDTH IN FEET 7 8 1.0 3 2 1 2 3 4 5 6 WIDTH IN FEET 7 575UT515 & 575UT535 WITH HORIZONTALS 575UT515 & 575UT535 WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN METERS 2.0 1.0 16 8 2.0 16 15 15 3/4" ALLOWABLE DEFLECTION 14 14 10 3.0 9 A 8 B 7 C 6 2.0 D 5 4 1.0 2 3 4 5 6 WIDTH IN FEET 7 8 * 11 10 A 9 3.0 B 8 C 575UT515 / 575UT535 7 * LOCATE FASTENER 6" FROM EACH END AND 9" O.C. D E 2.0 6 5 E 1 12 HEIGHT IN FEET 11 HEIGHT IN METERS 12 4.0 13 WINDLOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505 ADMC093 4 3 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 8 HEIGHT IN METERS 4.0 13 HEIGHT IN FEET A 9 6 WINDLOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505 1.0 1.0 © Kawneer Company, Inc., 2014 10 575T515 / 575T535 4 kawneer.com 4.0 13 HEIGHT IN METERS 3/4" ALLOWABLE DEFLECTION 4.0 13 3 2.0 15 14 2 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 575T515 & 575T535 WITH HORIZONTALS 1.0 HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. HURRICANE RESISTANT PRODUCT IR 501T/IR 501UT Framing 14 FEBRUARY, 2015 WINDLOAD CHARTS EC 97911-073 14 11 9 A 8 B 7 C 6 2.0 575T516 / 575T536 E 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 8 575UT516 & 575UT536 WITH HORIZONTALS 2.0 16 15 14 11 3.0 9 A C 6 2.0 D 5 4 3 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 8 1 2 3 4 5 6 WIDTH IN FEET 1.0 7 8 2.0 15 14 4.0 12 * 575UT516 / 575UT536 * LOCATE FASTENER 6" FROM EACH END AND 9" O.C. E 1.0 16 B 7 2.0 4 13 HEIGHT IN METERS HEIGHT IN FEET 12 8 E WIDTH IN METERS 4.0 10 7 575UT516 & 575UT536 WITHOUT HORIZONTALS 3/4" ALLOWABLE DEFLECTION 13 C D 2 A = 30 PSF (1440) B = 40 PSF (1920) C = 50 PSF (2400) D = 70 PSF (3360) E = 90 PSF (4320) WIDTH IN METERS 1.0 B 8 3 WINDLOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505 HEIGHT IN FEET 2 9 5 * LOCATE FASTENER 6" FROM EACH END AND 9" O.C. 4 3 A 3.0 10 6 D 5 * HEIGHT IN FEET 11 HEIGHT IN METERS HEIGHT IN FEET 12 3.0 4.0 13 12 10 2.0 14 3/4" ALLOWABLE DEFLECTION 4.0 13 1.0 15 WINDLOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505 ADMC093 11 10 A 9 3.0 B 8 C 7 D E 2.0 6 5 4 3 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 8 kawneer.com © Kawneer Company, Inc., 2014 15 WIDTH IN METERS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2.0 HEIGHT IN METERS WIDTH IN METERS 1.0 575T516 & 575T536 WITHOUT HORIZONTALS A = 30 PSF (1440) B = 40 PSF (1920) C = 50 PSF (2400) D = 70 PSF (3360) E = 90 PSF (4320) HEIGHT IN METERS 575T516 & 575T536 WITH HORIZONTALS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. HURRICANE RESISTANT PRODUCT IR 501T/IR 501UT Framing FEBRUARY, 2015 EC 97911-073 15 WINDLOAD CHARTS 575T534 & 575T528 WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN METERS 2.0 1.0 3/4" ALLOWABLE DEFLECTION 15 14 11 11 A 3.0 9 B 8 7 C 2.0 6 * * HEIGHT IN FEET 12 HEIGHT IN METERS 12 10 D * LOCATE FASTENER 6" FROM EACH END AND 18" O.C. E 4 1 2 3 4 5 6 WIDTH IN FEET 7 8 D 8 E 7 2.0 5 2 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 575UT534 & 575UT528 WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN METERS 2.0 1.0 3/4" ALLOWABLE DEFLECTION 8 2.0 16 15 15 14 4.0 11 10 3.0 A 9 8 B 7 C 6 2.0 * * 575UT534 / 575UT528 * LOCATE FASTENER 6" FROM EACH END AND 18" O.C. D 5 12 4 1.0 2 3 4 5 6 WIDTH IN FEET 7 8 11 A 10 B 9 3.0 C D 8 E 7 2.0 6 5 E 1 HEIGHT IN FEET 12 4.0 13 HEIGHT IN METERS 13 WINDLOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505 ADMC093 4 3 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 8 HEIGHT IN METERS 14 HEIGHT IN FEET 3.0 9 3 WINDLOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505 16 © Kawneer Company, Inc., 2014 C 575UT534 & 575UT528 WITH HORIZONTALS 1.0 kawneer.com B 10 4 1.0 3 A 6 575T534 / 575T528 5 4.0 13 HEIGHT IN METERS 4.0 13 3 2.0 15 14 2 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 575T534 & 575T528 WITH HORIZONTALS 1.0 HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. HURRICANE RESISTANT PRODUCT IR 501T/IR 501UT Framing 16 FEBRUARY, 2015 WINDLOAD CHARTS WINDLOAD CHARTS EC 97911-073 A = 30 PSF (1440) B = 40 PSF (1920) C = 50 PSF (2400) D = 70 PSF (3360) E = 90 PSF (4320) 575T501 SINGLE SPAN 575UT501 SINGLE SPAN HORIZONTAL CENTERS IN METERS 1.0 HORIZONTAL CENTERS IN METERS 2.0 1.0 15 14 15 4.0 10 3.0 9 8 7 A 6 2.0 B 5 WINDLOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505 C 4 1 12 11 10 3.0 9 A 8 7 B C D 2.0 6 E 5 D 1.0 E 3 4.0 13 HORIZONTAL LENGTH IN METERS 11 575UT501 HORIZONTAL LENGTH IN FEET HORIZONTAL LENGTH IN FEET 12 14 HORIZONTAL LENGTH IN METERS 13 2 2.0 16 4 3 2 3 4 5 6 7 8 HORIZONTAL CENTERS IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. HURRICANE RESISTANT PRODUCT 1.0 1 2 3 4 5 6 7 8 HORIZONTAL CENTERS IN FEET 575UT503 SINGLE SPAN HORIZONTAL CENTERS IN METERS HORIZONTAL CENTERS IN METERS 1.0 1.0 2.0 14 15 4.0 10 3.0 9 8 7 A 2.0 6 B 5 WINDLOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505 C 4 1 12 11 10 3.0 9 8 A 7 B C D 6 2.0 E 5 D 1.0 E 3 4.0 13 HORIZONTAL LENGTH IN METERS 11 575UT503 HORIZONTAL LENGTH IN FEET 12 14 HORIZONTAL LENGTH IN METERS HORIZONTAL LENGTH IN FEET 13 2 2.0 16 15 4 3 2 3 4 5 6 7 8 HORIZONTAL CENTERS IN FEET 1.0 1 2 3 4 5 6 7 8 HORIZONTAL CENTERS IN FEET 575T503 ADMC093 kawneer.com © Kawneer Company, Inc., 2014 575T503 SINGLE SPAN Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 575T501 IR 501T/IR 501UT Framing FEBRUARY, 2015 EC 97911-073 17 WINDLOAD CHARTS A = 30 PSF (1440) B = 40 PSF (1920) C = 50 PSF (2400) D = 70 PSF (3360) E = 90 PSF (4320) 575T511 SINGLE SPAN 575UT511 SINGLE SPAN HORIZONTAL CENTERS IN METERS 1.0 HORIZONTAL CENTERS IN METERS 1.0 2.0 14 15 4.0 10 3.0 9 8 7 A 6 2.0 B 5 WINDLOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505 1 11 10 3.0 9 8 A 7 B C D 2.0 E 5 D 1.0 E 3 12 6 C 4 4.0 13 HORIZONTAL LENGTH IN METERS 11 575UT511 HORIZONTAL LENGTH IN FEET 12 14 HORIZONTAL LENGTH IN METERS 13 2 2.0 16 15 HORIZONTAL LENGTH IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. HURRICANE RESISTANT PRODUCT 4 3 2 3 4 5 6 7 8 HORIZONTAL CENTERS IN FEET 1.0 1 2 3 4 5 6 7 8 HORIZONTAL CENTERS IN FEET 575T513 SINGLE SPAN 575UT513 SINGLE SPAN HORIZONTAL CENTERS IN METERS HORIZONTAL CENTERS IN METERS 1.0 1.0 2.0 15 14 4.0 10 3.0 9 8 7 A 2.0 6 B 5 WINDLOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505 C 4 D 1.0 E 3 1 12 11 10 3.0 9 8 7 A B C 2.0 6 D 5 E 4 3 2 3 4 5 6 7 8 HORIZONTAL CENTERS IN FEET 575T513 kawneer.com 4.0 13 ADMC093 1.0 1 2 3 4 5 6 7 8 HORIZONTAL CENTERS IN FEET HORIZONTAL LENGTH IN METERS 11 575UT513 HORIZONTAL LENGTH IN FEET 12 14 HORIZONTAL LENGTH IN METERS HORIZONTAL LENGTH IN FEET 13 2 2.0 16 15 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 575T511 IR 501T/IR 501UT Framing 18 FEBRUARY, 2015 DEADLOAD CHARTS EC 97911-073 HURRICANE RESISTANT PRODUCT Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1-5/16" thick insulated impact resistant glass supported on two setting blocks placed at the loading points shown. 575UT011 575T011 WIDTH IN METERS WIDTH IN METERS 1.0 2.0 15 16 14 15 4.0 12 13 11 12 9 8 7 2.0 6 10 3.0 9 8 7 2.0 6 5 4 5 1.0 4 B 2 1.0 3 A 1 1 2 5 6 3 4 WIDTH IN FEET 7 8 B 2 1 575T011 ADMC093 A 1 2 5 6 3 4 WIDTH IN FEET 7 8 575UT011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3 0 4.0 11 HEIGHT IN FEET 3.0 HEIGHT IN METERS 10 HEIGHT IN FEET 14 kawneer.com © Kawneer Company, Inc., 2014 13 2.0 HEIGHT IN METERS 1.0 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = (1/4 POINT LOADING) B = (1/8 POINT LOADING) IR 501T/IR 501UT Framing FEBRUARY, 2015 EC 97911-073 THERMAL CHARTS HURRICANE RESISTANT PRODUCT Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines) 15'-8" 2'-0" 9'-6" 7'-0" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 5'-0" Example Glass U-factor= 0.42 Btu/hr·ft2·oF Total Daylight Opening = 3(5' x 7') + 3(5' x 2') = 135ft2 Total Projected Area = (Total Daylight Opening + Total Area of Framing System) = 15'-8" x 9'-6" = 148.83ft2 Percent of Glass = (Total Daylight Opening ÷ Total Projected Area) = (135 ÷ 148.83)100 = 91% System U-factor vs Percent of Glass Area 0.75 0.70 0.65 X E COG U-factor 0.55 0.50 P 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.45 L 0.40 E © Kawneer Company, Inc., 2014 0.60 M A 0.35 0.30 0.25 70 75 80 90 91% 85 0.20 95 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.80 Percent of Glass Based on 91% glass and center of glass (COG) U-factor of 0.42 System U-factor is equal to 0.49 Btu/hr x ft2 x oF kawneer.com ADMC093 0.49 19 IR 501T/IR 501UT Framing FEBRUARY, 2015 EC 97911-073 THERMAL CHARTS HURRICANE RESISTANT PRODUCT IR 501T Framing COG U-factor 0.48 (2.73) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.03) 0.16 (0.91) 0.14 (0.80) 0.12 (0.69) 0.10 (0.57) Vision Area / Total Area (%) ADMC093 kawneer.com © Kawneer Company, Inc., 2014 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-Factor for Vision Glass Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. System U-Factor (Btu/h·ft2·°F) 20 System VT © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. FEBRUARY, 2015 COG SHGC COG VT kawneer.com IR 501T/IR 501UT Framing EC 97911-073 Vision Area / Total Area (%) Charts are generated per AAMA 507. ADMC093 21 THERMAL CHARTS HURRICANE RESISTANT PRODUCT System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area IR 501T Framing Vision Area / Total Area (%) Charts are generated per AAMA 507. System Visible Transmittance (VT) vs Percent of Vision Area IR 501T Framing IR 501T/IR 501UT Framing FEBRUARY, 2015 EC 97911-073 THERMAL PERFORMANCE MATRIX (NFRC SIZE) HURRICANE RESISTANT PRODUCT Thermal Transmittance 1 (BTU/hr • ft 2 • °F) 0.48 0.55 0.46 0.53 0.44 0.51 0.42 0.50 0.40 0.48 0.38 0.47 0.36 0.45 0.34 0.44 0.32 0.42 0.30 0.40 0.28 0.39 0.26 0.37 0.24 0.36 0.22 0.34 0.20 0.33 0.18 0.31 0.16 0.29 0.14 0.27 0.12 0.26 0.10 0.24 IR 501T Framing NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.65 0.75 0.64 0.70 0.61 0.70 0.60 0.65 0.56 0.65 0.55 0.60 0.52 0.60 0.51 0.55 0.48 0.55 0.47 0.50 0.44 0.50 0.43 0.45 0.39 0.45 0.38 0.40 0.35 0.40 0.34 0.35 031 0.35 0.30 0.30 0.27 0.30 0.26 0.25 0.22 0.25 0.21 0.20 0.18 0.20 0.17 0.15 0.14 0.15 0.13 0.10 0.10 0.10 0.09 0.05 0.05 0.05 0.04 ADMC093 kawneer.com © Kawneer Company, Inc., 2014 Overall U-Factor 4 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 22 FEBRUARY, 2015 IR 501T/IR 501UT Framing EC 97911-073 23 THERMAL CHARTS HURRICANE RESISTANT PRODUCT Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. IR 501UT Framing Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-Factor for Vision Glass System U-Factor (Btu/h·ft2·°F) COG U-factor 0.48 (2.73) 0.46 (2.61) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.44 (2.50) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) Vision Area / Total Area (%) kawneer.com ADMC093 COG SHGC Vision Area / Total Area (%) COG VT System Visible Transmittance (VT) vs Percent of Vision Area IR 501UT Framing Vision Area / Total Area (%) Charts are generated per AAMA 507. ADMC093 kawneer.com © Kawneer Company, Inc., 2014 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC IR 501T/IR 501UT Framing Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 24 FEBRUARY, 2015 EC 97911-073 HURRICANE RESISTANT PRODUCT System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area IR 501UT Framing Charts are generated per AAMA 507. IR 501T/IR 501UT Framing FEBRUARY, 2015 EC 97911-073 25 THERMAL PERFORMANCE MATRIX (NFRC SIZE) HURRICANE RESISTANT PRODUCT Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.52 0.46 0.50 0.44 0.49 0.42 0.47 0.40 0.45 0.38 0.44 0.36 0.42 0.34 0.41 0.32 0.39 0.30 0.38 0.28 0.36 0.26 0.34 0.24 0.33 0.22 0.31 0.20 0.30 IR 501UT Framing NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.65 0.75 0.64 0.70 0.60 0.70 0.60 0.65 0.56 0.65 0.55 0.60 0.52 0.60 0.51 0.55 0.48 0.55 0.47 0.50 0.43 0.50 0.43 0.45 0.39 0.45 0.38 0.40 0.35 0.40 0.34 0.35 0.31 0.35 0.30 0.30 0.26 0.30 0.26 0.25 0.22 0.25 0.21 0.20 0.18 0.20 0.17 0.15 0.14 0.15 0.13 0.10 0.09 0.10 0.09 0.05 0.05 0.05 0.04 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com ADMC093 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. IR 501T/IR 501UT Framing BLANK PAGE ADMC093 kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 26 FEBRUARY, 2015 EC 97911-073 HURRICANE RESISTANT PRODUCT