IR 501T/501UT - Architectural Detail Manual

IR 501T/IR 501UT Framing
FEBRUARY, 2015
EC 97911-073
FEATURES
HURRICANE RESISTANT PRODUCT
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Features
• IR 501T/IR 501UT is 5" (127) deep and has a 2-3/4" (69.9) sightline
{Expansion mullions have a 3" (76.2) sightline}
• Screw Spline fabrication
• IR 501T Single IsoLockTM lanced pour and debridge thermal break
• IR 501UT Dual IsolockTM lanced pour and debridge thermal break
• Center glazed
• Outside glazed
•PermanodicTM anodized finishes in seven choices
• Painted finishes in standard and custom choices
Optional Features
•
•
•
•
•
Integrated entrance framing
350 IR/500 IR - single or pairs of entrances
Strap anchor at head and jamb
Acoustical rating per AAMA 1801 and ASTM E 1425
Project specific U-Factor (see thermal charts)
•
•
•
•
Impact resistant
Storefront, ribbon window or punched opening
Low to mid-rise
Single span
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Product Applications
For specific product applications,
Consult your Kawneer representative.
kawneer.com
ADMC093
1
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
IR 501T/IR 501UT Framing
BLANK PAGE
ADMC093
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2
FEBRUARY, 2015
EC 97911-073
HURRICANE RESISTANT PRODUCT
FEBRUARY, 2015
IR 501T/IR 501UT Framing
EC 97911-073
3
INDEX
BASIC FRAMING DETAILS.................................................................. 4
MISCELLANEOUS DETAILS............................................................... 5
STRAP ANCHOR DETAILS................................................................. 6
CORNER DETAILS............................................................................... 7
ENTRANCE FRAMING......................................................................... 8
GLASSvent TM WINDOW DETAILS ...................................................... 9
WINDLOAD CHARTS ................................................................... 10-17
DEADLOAD CHARTS........................................................................ 18
THERMAL CHARTS...................................................................... 19-25
LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED
ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT
CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR
GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR.
Metric (SI) conversion figures are included throughout these details for reference.
Numbers in parentheses (
) are millimeters unless otherwise noted.
The following metric (SI) units are found in these details:
m –meter
cm – centimeter
mm –millimeter
s –second
Pa –pascal
MPa –megapascal
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
HURRICANE RESISTANT PRODUCT
Kawneer reserves the right to change configurations without prior notice when deemed necessary
for product improvement.
kawneer.com
ADMC093
IR 501T/IR 501UT Framing
4
FEBRUARY, 2015
EC 97911-073
BASIC FRAMING DETAILS
HURRICANE RESISTANT PRODUCT
SCALE 3" = 1'-0"
1
5
2
IR 501UT DUAL IsoLockTM
THERMAL BREAK
ELEVATION IS NUMBER KEYED TO DETAILS
1-5/16" INFILL (DRY GLAZED)
1-5/16" INFILL (WET GLAZED)
575UT514
[575T514]
575UT514
[575T514]
575531
2-3/4"
(69.9)
4
JAMB
5
VERTICAL
5"
(127.4)
2-3/4"
(69.9)
2-3/4"
(69.9)
4
JAMB
5
VERTICAL
THERMAL FILLER
1
HEAD
2-3/4"
(69.9)
1
HEAD
3/8"
(9.5)
575532
3/8"
(9.5)
2-3/4"
(69.9)
3/8"
(9.5)
3/8"
(9.5)
575UT500
[575T500]
575532
THERMAL FILLER
2-3/4"
(69.9)
575UT500
[575T500]
THERMAL
FILLER
5"
(127.0)
5"
(127.4)
5"
(127.0)
THERMAL
FILLER
575531
575UT501
[575T501]
575UT501
[575T501]
5"
(127.4)
5"
(127.4)
2
HORIZONTAL
2-3/4"
(69.9)
3/8"
(9.5)
575UT513
[575T513]
3
SILL
575UT537
[575T537]
2-15/32"
(63.1)
ADMC093
575504
575UT511
[575T511]
575504
575UT513
[575T513]
1/2"
(12.7)
2-3/4"
(69.9)
3
SILL
1/2"
(12.7)
2-3/4"
(69.9)
575504
3/8"
(9.5)
2
HORIZONTAL
575UT511
[575T511]
2-3/4"
(69.9)
575504
575UT537
[575T537]
2-15/32"
(63.1)
kawneer.com
© Kawneer Company, Inc., 2014
3
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
4
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
IR 501T Single IsoLockTM
THERMAL BREAK
IR 501T/IR 501UT Framing
FEBRUARY, 2015
EC 97911-073
MISCELLANEOUS DETAILS
HURRICANE RESISTANT PRODUCT
SCALE 3" = 1'-0"
1-5/16" INFILL (DRY GLAZED)
3/8"
(9.5)
3/8"
(9.5)
THERMAL FILLER
2-3/4"
(69.9)
2-3/4"
(69.9)
THERMAL FILLER
575504
575504
575UT503
[575T503]
575UT503
[575T503]
5"
(126.6)
5"
(126.6)
OPTIONAL HEAD
WITH STOP
575T510
OPTIONAL HEAD
WITH STOP
575T509
575T510
1/4"
(6.4)
575T509
1/4"
(6.4)
3"
(76.2)
3"
(76.2)
EXPANSION MULLION
EXPANSION MULLION
5"
(127.0)
575UT516
[575T516]
5"
(127.0)
575UT516
[575T516]
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1-5/16" INFILL (WET GLAZED)
575UT515
[575T515]
575UT515
[575T515]
5"
(127.0)
5"
(127.0)
5" x 5" MULLION
kawneer.com
5" x 5" MULLION
ADMC093
5
IR 501T/IR 501UT Framing
FEBRUARY, 2015
STRAP ANCHOR DETAILS
EC 97911-073
HURRICANE RESISTANT PRODUCT
SCALE 3" = 1'-0"
STRAP ANCHOR
2-3/4"
(69.9)
2-3/4"
(69.9)
3/8"
(9.5)
3/8"
(9.5)
STRAP ANCHOR
575UT501
[575T501]
575UT501
[575T501]
5"
(127.0)
6-1/2"
(165.1)
7-7/8"
(200.0)
5"
(127.0)
6-1/2"
(165.1)
7-7/8"
(200.0)
HEAD
HEAD
3/8"
(9.5)
STRAP ANCHOR
575504
575UT503
[575T503]
OPTIONAL HEAD
WITH STOP
OPTIONAL HEAD
WITH STOP
STRAP
ANCHOR
5"
(127.0)
6-1/2"
(165.1)
7-7/8"
(200.0)
5"
(127.0)
6-1/2"
(165.1)
7-7/8"
(200.0)
5"
(127.0)
6-1/2"
(165.1)
7-7/8"
(200.0)
5"
(127.0)
6-1/2"
(165.1)
7-7/8"
(200.0)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
575UT503
[575T503]
STRAP
ANCHOR
575UT500
[575T500]
575UT500
[575T500]
2-3/4"
(69.9)
3/8"
(9.5)
JAMB
2-3/4"
(69.9)
JAMB
ADMC093
kawneer.com
© Kawneer Company, Inc., 2014
2-3/4"
(69.9)
3/8"
(9.5)
STRAP ANCHOR
575504
3/8"
(9.5)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1-5/16" INFILL (DRY GLAZED)
1-5/16" INFILL (WET GLAZED)
2-3/4"
(69.9)
6
IR 501T/IR 501UT Framing
FEBRUARY, 2015
EC 97911-073
7
CORNER DETAILS
HURRICANE RESISTANT PRODUCT
SCALE 3" = 1'-0"
1-5/16" INFILL (DRY GLAZED)
575UT536
[575T536]
5"
(127.0)
5"
(127.0)
575UT536
[575T536]
575UT516
[575T516]
575UT516
[575T516]
5"
(127.0)
5"
(127.0)
575UT535
[575T535]
5"
(127.0)
5"
(127.0)
575UT535
[575T535]
575UT515
[575T515]
575UT515
[575T515]
5"
(127.0)
135°
135°
575UT528
[575T528]
575UT528
[575T528]
5"
)
7.0
5"
)
7.0
(12
(12
575UT534 [575T534]
3-1
/2
(88 "
.9)
© Kawneer Company, Inc., 2014
575UT534 [575T534]
3-1
/2
(88 "
.9)
/2"
3-1 )
.9
(88
575UT534
[575T534]
135°
575UT534
[575T534]
575UT528
[575T528]
5"
7.0
5"
7.0
)
)
135°
/2"
3-1 )
.9
8
( 8
(12
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
5"
(127.0)
575UT528
[575T528]
1-7
/16
"
(36
.3)
kawneer.com
1-7
/16
"
(36
.3)
ADMC093
(12
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1-5/16" INFILL (WET GLAZED)
IR 501T/IR 501UT Framing
8
FEBRUARY, 2015
ENTRANCE FRAMING
EC 97911-073
HURRICANE RESISTANT PRODUCT
SCALE 3" = 1'-0"
2
5
4
8
7
6
4
575551
2
575135
3
THERMAL
FILLER
3/8"
(9.5)
7
1
2-3/4"
(69.9)
1
575UT501
[575T501]
2-3/4"
(69.9)
3
1
TRANSOM HEAD
OPTIONAL
2-3/4" DOOR JAMB
ELEVATION IS NUMBER KEYED TO DETAILS
5"
(127)
575051
575051
575133
575122
575104
2-1/2"
(63.5)
1-1/8"
(28.6)
8
DOOR JAMB
AT TRANSOM
7
DOOR JAMB
AT TRANSOM
575051
2
DOOR WITH TRANSOM
3/32"
(2.4)
2-1/2"
(63.5)
3-1/2"
(88.9)
3-1/2"
(88.9)
3/32"
(2.4)
6-1/2"
(165.1)
575135
575135
575051
2-1/2"
(63.5)
200795
6
DOOR JAMB
4
DOOR JAMB
11/16"
(17.5)
069139
3-1/2"
(88.9)
1/8"
(3.2)
3
THRESHOLD
3-1/2"
(88.9)
5
PAIR OF DOORS
ADMC093
kawneer.com
© Kawneer Company, Inc., 2014
1-1/8"
(28.6)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2-1/2"
(63.5)
3-1/2"
(88.9)
575135
1/8"
(3.2)
575135
2-1/2"
(63.5)
575133
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
IR 501 FRAMING INCORPORATING KAWNEER 350 IR DOORS. DOOR FRAMING NON-THERMAL ONLY. SEE 350 IR ENTRANCES FOR
ADDITIONAL DOOR AND ENTRANCE FRAMING OPTIONS.
IR 501T/IR 501UT Framing
FEBRUARY, 2015
EC 97911-073
GLASSventTM WINDOW DETAILS
HURRICANE RESISTANT PRODUCT
SCALE 3" = 1'-0"
575UT511
[575T511]
575504
1
575204
1
3
4
5
2
ELEVATION IS NUMBER KEYED TO DETAILS
575504
575204
Hardware:
Hinge:Stainless Steel 4-Bar
Lock: Hurricane Cam Handles
2
575UT537
[575T537]
575UT513
[575T513]
PROJECT-OUT
VERTICAL SECTION
575531
575531
575532
3
575UT514
[575T514]
575532
575UT500
[575T500]
4
NOTE: Black spacer is recommended when 1" insulating glass is used.
kawneer.com
THERMAL
FILLER
575204
575204
575204
575UT514
[575T514]
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
PROJECT-OUT
HORIZONTAL SECTION
ADMC093
5
9
IR 501T/IR 501UT Framing
10
FEBRUARY, 2015
WINDLOAD CHARTS
EC 97911-073
HURRICANE RESISTANT PRODUCT
A = 30 PSF (1440)
B = 40 PSF (1920)
C = 50 PSF (2400)
D = 70 PSF (3360)
E = 90 PSF (4320)
575T500
WITH HORIZONTALS
WIDTH IN METERS
2.0
15
WIDTH IN METERS
1.0
14
14
11
11
9
8
7
A
6
2.0
B
5
C
4
1
2
3
4
5
6
WIDTH IN FEET
7
8
B
C
7
D
E
2.0
5
1.0
3
2
1
2
3
4
5
6
WIDTH IN FEET
7
8
575UT500
WITHOUT HORIZONTALS
** 84" maximum vertical DLO anchored at top and bottom
only. Add perimeter fasteners to increase DLO height.
2.0
16
15
WIDTH IN METERS
1.0
2.0
16
15
14
14
10
3.0
9
8
7
2.0
6
A
5
B
C
4
D
1
2
3
4
5
6
WIDTH IN FEET
7
E
8
12
575UT500
WINDLOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH ARE
CALCULATED IN ACCORDANCE WITH
AAMA TIR-8 AND AAMA 505
HEIGHT IN FEET
11
HEIGHT IN METERS
12
4.0
13
11
10
3.0
9
A
8
B
C
7
D
E
6
HEIGHT IN METERS
4.0
13
HEIGHT IN FEET
A
8
* 92 3/4" maximum DLO with anchors located at top and
bottom of intermediate horizontals.
WIDTH IN METERS
3
9
6
MAXIMUM ALLOWABLE STRESS AND DEFLECTION
for 575T500 and 575UT500
8,000 PSI WITH HORIZONTALS*
9,000 PSI WITHOUT HORIZONTALS**
1/4" ALLOWABLE DEFLECTION @ JAMBS
575UT500
WITH HORIZONTALS
1.0
WINDLOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH ARE
CALCULATED IN ACCORDANCE WITH
AAMA TIR-8 AND AAMA 505
3.0
4
D
1.0
E
3
575T500
10
2.0
5
4
1.0
3
ADMC093
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
8
kawneer.com
© Kawneer Company, Inc., 2014
3.0
HEIGHT IN FEET
12
HEIGHT IN METERS
HEIGHT IN FEET
12
10
4.0
13
HEIGHT IN METERS
4.0
13
2
2.0
15
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1.0
575T500
WITHOUT HORIZONTALS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L\175 up to 13'-6" and L\240 + 1/4" above 13'-6". These curves are
for mullions WITH and WITHOUT HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for
ALUMINUM (assuming full lateral buckling support) 15,152 psi (104 MPa), FORMED STEEL 30,000 P.S.I. (207 MPa), STEEL BAR 20,000 psi (138 MPa).
Charted curves, in all cases, are for the limiting value. If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier
editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop
these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information.
IR 501T/IR 501UT Framing
FEBRUARY, 2015
11
EC 97911-073
575T509 & 575T510
WITH HORIZONTALS
1.0
2.0
16
575T509 & 575T510
WITHOUT HORIZONTALS
WIDTH IN METERS
1.0
15
14
14
A
10
3.0
B
9
8
C
7
2.0
6
D
5
12
575T509 / 575T510
WINDLOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH ARE
CALCULATED IN ACCORDANCE WITH
AAMA TIR-8 AND AAMA 505
E
4
HEIGHT IN FEET
11
HEIGHT IN METERS
12
4.0
13
A
11
B
10
C
9
3.0
D
E
8
7
2.0
6
5
4
1.0
2
3
4
5
6
WIDTH IN FEET
7
3
8
© Kawneer Company, Inc., 2014
1
ADMC093
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
8
HEIGHT IN METERS
4.0
13
kawneer.com
2.0
16
15
3
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
A = 30 PSF (1440)
B = 40 PSF (1920)
C = 50 PSF (2400)
D = 70 PSF (3360)
E = 90 PSF (4320)
WIDTH IN METERS
HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
HURRICANE RESISTANT PRODUCT
IR 501T/IR 501UT Framing
12
FEBRUARY, 2015
WINDLOAD CHARTS
EC 97911-073
2.0
15
WIDTH IN METERS
1.0
14
14
12
11
11
9
8
A
7
2.0
6
C
4
D
3
E
1
2
3
4
5
6
WIDTH IN FEET
7
2.0
D 2.0
E
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
8
575UT514
WITHOUT HORIZONTALS
WIDTH IN METERS
1.0
2.0
16
15
15
14
14
10
3.0
9
A
8
7
B
6
2.0
C
5
D
E
4
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
12
HEIGHT IN FEET
11
HEIGHT IN METERS
12
4.0
13
575UT514
WINDLOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH ARE
CALCULATED IN ACCORDANCE WITH
AAMA TIR-8 AND AAMA 505
11
10
A 3.0
9
B
8
C
7
D
ADMC093
2.0
5
4
3
8
E
6
HEIGHT IN METERS
4.0
13
HEIGHT IN FEET
C
7
3
A = 30 PSF (1440)
B = 40 PSF (1920)
C = 50 PSF (2400)
D = 70 PSF (3360)
E = 90 PSF (4320)
16
3
8
2
WIDTH IN METERS
B
4
8
575UT514
WITH HORIZONTALS
1.0
9
3.0
5
WINDLOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH ARE
CALCULATED IN ACCORDANCE WITH
AAMA TIR-8 AND AAMA 505
1.0
A
10
6
575T514
B
5
HEIGHT IN FEET
3.0
HEIGHT IN METERS
HEIGHT IN FEET
12
10
4.0
13
HEIGHT IN METERS
4.0
13
2
2.0
15
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
8
kawneer.com
© Kawneer Company, Inc., 2014
WIDTH IN METERS
1.0
575T514
WITHOUT HORIZONTALS
A = 30 PSF (1440)
B = 40 PSF (1920)
C = 50 PSF (2400)
D = 70 PSF (3360)
E = 90 PSF (4320)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
575T514
WITH HORIZONTALS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
HURRICANE RESISTANT PRODUCT
IR 501T/IR 501UT Framing
FEBRUARY, 2015
13
EC 97911-073
575T515 & 575T535
WITHOUT HORIZONTALS
WIDTH IN METERS
WIDTH IN METERS
2.0
1.0
15
14
11
11
3.0
9
A
8
B
7
C
6
2.0
D
5
E
HEIGHT IN FEET
12
HEIGHT IN METERS
12
10
*
B
8
C
7
* LOCATE FASTENER 6" FROM EACH END AND 9" O.C.
5
3.0
D
E
2.0
4
3
1
2
3
4
5
6
WIDTH IN FEET
7
8
1.0
3
2
1
2
3
4
5
6
WIDTH IN FEET
7
575UT515 & 575UT535
WITH HORIZONTALS
575UT515 & 575UT535
WITHOUT HORIZONTALS
WIDTH IN METERS
WIDTH IN METERS
2.0
1.0
16
8
2.0
16
15
15
3/4" ALLOWABLE DEFLECTION
14
14
10
3.0
9
A
8
B
7
C
6
2.0
D
5
4
1.0
2
3
4
5
6
WIDTH IN FEET
7
8
*
11
10
A
9
3.0
B
8
C
575UT515 / 575UT535
7
* LOCATE FASTENER 6" FROM EACH END AND 9" O.C.
D
E 2.0
6
5
E
1
12
HEIGHT IN FEET
11
HEIGHT IN METERS
12
4.0
13
WINDLOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH ARE
CALCULATED IN ACCORDANCE WITH
AAMA TIR-8 AND AAMA 505
ADMC093
4
3
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
8
HEIGHT IN METERS
4.0
13
HEIGHT IN FEET
A
9
6
WINDLOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH ARE
CALCULATED IN ACCORDANCE WITH
AAMA TIR-8 AND AAMA 505
1.0
1.0
© Kawneer Company, Inc., 2014
10
575T515 / 575T535
4
kawneer.com
4.0
13
HEIGHT IN METERS
3/4" ALLOWABLE DEFLECTION
4.0
13
3
2.0
15
14
2
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
575T515 & 575T535
WITH HORIZONTALS
1.0
HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
HURRICANE RESISTANT PRODUCT
IR 501T/IR 501UT Framing
14
FEBRUARY, 2015
WINDLOAD CHARTS
EC 97911-073
14
11
9
A
8
B
7
C
6
2.0
575T516 / 575T536
E
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
8
575UT516 & 575UT536
WITH HORIZONTALS
2.0
16
15
14
11
3.0
9
A
C
6
2.0
D
5
4
3
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
8
1
2
3
4
5
6
WIDTH IN FEET
1.0
7
8
2.0
15
14
4.0
12
*
575UT516 / 575UT536
* LOCATE FASTENER 6" FROM EACH END AND 9" O.C.
E
1.0
16
B
7
2.0
4
13
HEIGHT IN METERS
HEIGHT IN FEET
12
8
E
WIDTH IN METERS
4.0
10
7
575UT516 & 575UT536
WITHOUT HORIZONTALS
3/4" ALLOWABLE DEFLECTION
13
C
D
2
A = 30 PSF (1440)
B = 40 PSF (1920)
C = 50 PSF (2400)
D = 70 PSF (3360)
E = 90 PSF (4320)
WIDTH IN METERS
1.0
B
8
3
WINDLOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH ARE
CALCULATED IN ACCORDANCE WITH
AAMA TIR-8 AND AAMA 505
HEIGHT IN FEET
2
9
5
* LOCATE FASTENER 6" FROM EACH END AND 9" O.C.
4
3
A 3.0
10
6
D
5
*
HEIGHT IN FEET
11
HEIGHT IN METERS
HEIGHT IN FEET
12
3.0
4.0
13
12
10
2.0
14
3/4" ALLOWABLE DEFLECTION
4.0
13
1.0
15
WINDLOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH ARE
CALCULATED IN ACCORDANCE WITH
AAMA TIR-8 AND AAMA 505
ADMC093
11
10
A
9
3.0
B
8
C
7
D
E 2.0
6
5
4
3
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
8
kawneer.com
© Kawneer Company, Inc., 2014
15
WIDTH IN METERS
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2.0
HEIGHT IN METERS
WIDTH IN METERS
1.0
575T516 & 575T536
WITHOUT HORIZONTALS
A = 30 PSF (1440)
B = 40 PSF (1920)
C = 50 PSF (2400)
D = 70 PSF (3360)
E = 90 PSF (4320)
HEIGHT IN METERS
575T516 & 575T536
WITH HORIZONTALS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
HURRICANE RESISTANT PRODUCT
IR 501T/IR 501UT Framing
FEBRUARY, 2015
EC 97911-073
15
WINDLOAD CHARTS
575T534 & 575T528
WITHOUT HORIZONTALS
WIDTH IN METERS
WIDTH IN METERS
2.0
1.0
3/4" ALLOWABLE DEFLECTION
15
14
11
11
A
3.0
9
B
8
7
C 2.0
6
*
*
HEIGHT IN FEET
12
HEIGHT IN METERS
12
10
D
* LOCATE FASTENER 6" FROM EACH END AND 18" O.C.
E
4
1
2
3
4
5
6
WIDTH IN FEET
7
8
D
8
E
7
2.0
5
2
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
575UT534 & 575UT528
WITHOUT HORIZONTALS
WIDTH IN METERS
WIDTH IN METERS
2.0
1.0
3/4" ALLOWABLE DEFLECTION
8
2.0
16
15
15
14
4.0
11
10
3.0
A
9
8
B
7
C
6
2.0
*
*
575UT534 / 575UT528
* LOCATE FASTENER 6" FROM EACH END AND 18" O.C.
D
5
12
4
1.0
2
3
4
5
6
WIDTH IN FEET
7
8
11
A
10
B
9
3.0
C
D
8
E
7
2.0
6
5
E
1
HEIGHT IN FEET
12
4.0
13
HEIGHT IN METERS
13
WINDLOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH ARE
CALCULATED IN ACCORDANCE WITH
AAMA TIR-8 AND AAMA 505
ADMC093
4
3
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
8
HEIGHT IN METERS
14
HEIGHT IN FEET
3.0
9
3
WINDLOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH ARE
CALCULATED IN ACCORDANCE WITH
AAMA TIR-8 AND AAMA 505
16
© Kawneer Company, Inc., 2014
C
575UT534 & 575UT528
WITH HORIZONTALS
1.0
kawneer.com
B
10
4
1.0
3
A
6
575T534 / 575T528
5
4.0
13
HEIGHT IN METERS
4.0
13
3
2.0
15
14
2
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
575T534 & 575T528
WITH HORIZONTALS
1.0
HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
HURRICANE RESISTANT PRODUCT
IR 501T/IR 501UT Framing
16
FEBRUARY, 2015
WINDLOAD CHARTS
WINDLOAD CHARTS
EC 97911-073
A = 30 PSF (1440)
B = 40 PSF (1920)
C = 50 PSF (2400)
D = 70 PSF (3360)
E = 90 PSF (4320)
575T501
SINGLE SPAN
575UT501
SINGLE SPAN
HORIZONTAL CENTERS IN METERS
1.0
HORIZONTAL CENTERS IN METERS
2.0
1.0
15
14
15
4.0
10
3.0
9
8
7
A
6
2.0
B
5
WINDLOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH ARE
CALCULATED IN ACCORDANCE WITH
AAMA TIR-8 AND AAMA 505
C
4
1
12
11
10
3.0
9
A
8
7
B
C
D 2.0
6
E
5
D
1.0
E
3
4.0
13
HORIZONTAL LENGTH IN METERS
11
575UT501
HORIZONTAL LENGTH IN FEET
HORIZONTAL LENGTH IN FEET
12
14
HORIZONTAL LENGTH IN METERS
13
2
2.0
16
4
3
2
3
4
5
6
7
8
HORIZONTAL CENTERS IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
HURRICANE RESISTANT PRODUCT
1.0
1
2
3
4
5
6
7
8
HORIZONTAL CENTERS IN FEET
575UT503
SINGLE SPAN
HORIZONTAL CENTERS IN METERS
HORIZONTAL CENTERS IN METERS
1.0
1.0
2.0
14
15
4.0
10
3.0
9
8
7
A 2.0
6
B
5
WINDLOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH ARE
CALCULATED IN ACCORDANCE WITH
AAMA TIR-8 AND AAMA 505
C
4
1
12
11
10
3.0
9
8
A
7
B
C
D
6
2.0
E
5
D
1.0
E
3
4.0
13
HORIZONTAL LENGTH IN METERS
11
575UT503
HORIZONTAL LENGTH IN FEET
12
14
HORIZONTAL LENGTH IN METERS
HORIZONTAL LENGTH IN FEET
13
2
2.0
16
15
4
3
2
3
4
5
6
7
8
HORIZONTAL CENTERS IN FEET
1.0
1
2
3
4
5
6
7
8
HORIZONTAL CENTERS IN FEET
575T503
ADMC093
kawneer.com
© Kawneer Company, Inc., 2014
575T503
SINGLE SPAN
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
575T501
IR 501T/IR 501UT Framing
FEBRUARY, 2015
EC 97911-073
17
WINDLOAD CHARTS
A = 30 PSF (1440)
B = 40 PSF (1920)
C = 50 PSF (2400)
D = 70 PSF (3360)
E = 90 PSF (4320)
575T511
SINGLE SPAN
575UT511
SINGLE SPAN
HORIZONTAL CENTERS IN METERS
1.0
HORIZONTAL CENTERS IN METERS
1.0
2.0
14
15
4.0
10
3.0
9
8
7
A
6
2.0
B
5
WINDLOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH ARE
CALCULATED IN ACCORDANCE WITH
AAMA TIR-8 AND AAMA 505
1
11
10
3.0
9
8
A
7
B
C
D
2.0
E
5
D 1.0
E
3
12
6
C
4
4.0
13
HORIZONTAL LENGTH IN METERS
11
575UT511
HORIZONTAL LENGTH IN FEET
12
14
HORIZONTAL LENGTH IN METERS
13
2
2.0
16
15
HORIZONTAL LENGTH IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
HURRICANE RESISTANT PRODUCT
4
3
2
3
4
5
6
7
8
HORIZONTAL CENTERS IN FEET
1.0
1
2
3
4
5
6
7
8
HORIZONTAL CENTERS IN FEET
575T513
SINGLE SPAN
575UT513
SINGLE SPAN
HORIZONTAL CENTERS IN METERS
HORIZONTAL CENTERS IN METERS
1.0
1.0
2.0
15
14
4.0
10
3.0
9
8
7
A 2.0
6
B
5
WINDLOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH ARE
CALCULATED IN ACCORDANCE WITH
AAMA TIR-8 AND AAMA 505
C
4
D
1.0
E
3
1
12
11
10
3.0
9
8
7
A
B
C 2.0
6
D
5
E
4
3
2
3
4
5
6
7
8
HORIZONTAL CENTERS IN FEET
575T513
kawneer.com
4.0
13
ADMC093
1.0
1
2
3
4
5
6
7
8
HORIZONTAL CENTERS IN FEET
HORIZONTAL LENGTH IN METERS
11
575UT513
HORIZONTAL LENGTH IN FEET
12
14
HORIZONTAL LENGTH IN METERS
HORIZONTAL LENGTH IN FEET
13
2
2.0
16
15
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
575T511
IR 501T/IR 501UT Framing
18
FEBRUARY, 2015
DEADLOAD CHARTS
EC 97911-073
HURRICANE RESISTANT PRODUCT
Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate horizontal member.
The accompanying charts are calculated for 1-5/16" thick insulated impact resistant glass supported on two setting blocks placed at the loading
points shown.
575UT011
575T011
WIDTH IN METERS
WIDTH IN METERS
1.0
2.0
15
16
14
15
4.0
12
13
11
12
9
8
7
2.0
6
10
3.0
9
8
7
2.0
6
5
4
5
1.0
4
B
2
1.0
3
A
1
1
2
5
6
3
4
WIDTH IN FEET
7
8
B
2
1
575T011
ADMC093
A
1
2
5
6
3
4
WIDTH IN FEET
7
8
575UT011
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
3
0
4.0
11
HEIGHT IN FEET
3.0
HEIGHT IN METERS
10
HEIGHT IN FEET
14
kawneer.com
© Kawneer Company, Inc., 2014
13
2.0
HEIGHT IN METERS
1.0
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
A = (1/4 POINT LOADING)
B = (1/8 POINT LOADING)
IR 501T/IR 501UT Framing
FEBRUARY, 2015
EC 97911-073
THERMAL CHARTS
HURRICANE RESISTANT PRODUCT
Generic Project Specific U-factor Example Calculation
(Percent of Glass will vary on specific products depending on sitelines)
15'-8"
2'-0"
9'-6"
7'-0"
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
5'-0"
Example Glass U-factor= 0.42 Btu/hr·ft2·oF
Total Daylight Opening = 3(5' x 7') + 3(5' x 2') = 135ft2
Total Projected Area
= (Total Daylight Opening + Total Area of Framing System)
= 15'-8" x 9'-6" = 148.83ft2
Percent of Glass
= (Total Daylight Opening ÷ Total Projected Area)
= (135 ÷ 148.83)100 = 91%
System U-factor vs Percent of Glass Area
0.75
0.70
0.65
X
E
COG
U-factor
0.55
0.50
P
0.48
0.46
0.44
0.42
0.40
0.38
0.36
0.34
0.32
0.30
0.28
0.26
0.24
0.22
0.20
0.45
L
0.40
E
© Kawneer Company, Inc., 2014
0.60
M
A
0.35
0.30
0.25
70
75
80
90
91%
85
0.20
95
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.80
Percent of Glass
Based on 91% glass and center of glass (COG) U-factor of 0.42
System U-factor is equal to 0.49 Btu/hr x ft2 x oF
kawneer.com
ADMC093
0.49
19
IR 501T/IR 501UT Framing
FEBRUARY, 2015
EC 97911-073
THERMAL CHARTS
HURRICANE RESISTANT PRODUCT
IR 501T Framing
COG
U-factor
0.48 (2.73)
0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.40 (2.27)
0.38 (2.16)
0.36 (2.05)
0.34 (1.93)
0.32 (1.82)
0.30 (1.71)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
0.18 (1.03)
0.16 (0.91)
0.14 (0.80)
0.12 (0.69)
0.10 (0.57)
Vision Area / Total Area (%)
ADMC093
kawneer.com
© Kawneer Company, Inc., 2014
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System U-Factor for Vision Glass
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Note:
Values in parentheses are metric.
COG=Center of Glass.
Charts are generated per AAMA 507.
System U-Factor (Btu/h·ft2·°F)
20
System VT
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
FEBRUARY, 2015
COG
SHGC
COG
VT
kawneer.com
IR 501T/IR 501UT Framing
EC 97911-073
Vision Area / Total Area (%)
Charts are generated per AAMA 507.
ADMC093
21
THERMAL CHARTS
HURRICANE RESISTANT PRODUCT
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
IR 501T Framing
Vision Area / Total Area (%)
Charts are generated per AAMA 507.
System Visible Transmittance (VT) vs Percent of Vision Area
IR 501T Framing
IR 501T/IR 501UT Framing
FEBRUARY, 2015
EC 97911-073
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
HURRICANE RESISTANT PRODUCT
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
0.48
0.55
0.46
0.53
0.44
0.51
0.42
0.50
0.40
0.48
0.38
0.47
0.36
0.45
0.34
0.44
0.32
0.42
0.30
0.40
0.28
0.39
0.26
0.37
0.24
0.36
0.22
0.34
0.20
0.33
0.18
0.31
0.16
0.29
0.14
0.27
0.12
0.26
0.10
0.24
IR 501T Framing
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
SHGC Matrix 2
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 2000mm wide by
2000mm high (78-3/4" by 78-3/4").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.65
0.75
0.64
0.70
0.61
0.70
0.60
0.65
0.56
0.65
0.55
0.60
0.52
0.60
0.51
0.55
0.48
0.55
0.47
0.50
0.44
0.50
0.43
0.45
0.39
0.45
0.38
0.40
0.35
0.40
0.34
0.35
031
0.35
0.30
0.30
0.27
0.30
0.26
0.25
0.22
0.25
0.21
0.20
0.18
0.20
0.17
0.15
0.14
0.15
0.13
0.10
0.10
0.10
0.09
0.05
0.05
0.05
0.04
ADMC093
kawneer.com
© Kawneer Company, Inc., 2014
Overall U-Factor 4
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
22
FEBRUARY, 2015
IR 501T/IR 501UT Framing
EC 97911-073
23
THERMAL CHARTS
HURRICANE RESISTANT PRODUCT
Note:
Values in parentheses are metric.
COG=Center of Glass.
Charts are generated per AAMA 507.
IR 501UT Framing
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System U-Factor for Vision Glass
System U-Factor (Btu/h·ft2·°F)
COG
U-factor
0.48 (2.73)
0.46 (2.61)
0.42 (2.39)
0.40 (2.27)
0.38 (2.16)
0.36 (2.05)
0.34 (1.93)
0.32 (1.82)
0.30 (1.71)
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.44 (2.50)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
Vision Area / Total Area (%)
kawneer.com
ADMC093
COG
SHGC
Vision Area / Total Area (%)
COG
VT
System Visible Transmittance (VT) vs Percent of Vision Area
IR 501UT Framing
Vision Area / Total Area (%)
Charts are generated per AAMA 507.
ADMC093
kawneer.com
© Kawneer Company, Inc., 2014
THERMAL CHARTS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System SHGC
IR 501T/IR 501UT Framing
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System VT
24
FEBRUARY, 2015
EC 97911-073
HURRICANE RESISTANT PRODUCT
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
IR 501UT Framing
Charts are generated per AAMA 507.
IR 501T/IR 501UT Framing
FEBRUARY, 2015
EC 97911-073
25
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
HURRICANE RESISTANT PRODUCT
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Overall U-Factor 4
0.48
0.52
0.46
0.50
0.44
0.49
0.42
0.47
0.40
0.45
0.38
0.44
0.36
0.42
0.34
0.41
0.32
0.39
0.30
0.38
0.28
0.36
0.26
0.34
0.24
0.33
0.22
0.31
0.20
0.30
IR 501UT Framing
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
SHGC Matrix 2
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 2000mm wide by
2000mm high (78-3/4" by 78-3/4").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.65
0.75
0.64
0.70
0.60
0.70
0.60
0.65
0.56
0.65
0.55
0.60
0.52
0.60
0.51
0.55
0.48
0.55
0.47
0.50
0.43
0.50
0.43
0.45
0.39
0.45
0.38
0.40
0.35
0.40
0.34
0.35
0.31
0.35
0.30
0.30
0.26
0.30
0.26
0.25
0.22
0.25
0.21
0.20
0.18
0.20
0.17
0.15
0.14
0.15
0.13
0.10
0.09
0.10
0.09
0.05
0.05
0.05
0.04
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
kawneer.com
ADMC093
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
IR 501T/IR 501UT Framing
BLANK PAGE
ADMC093
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
26
FEBRUARY, 2015
EC 97911-073
HURRICANE RESISTANT PRODUCT