IR 500/501 Series Framing Systems and 350/500 IR Entrances Single-Source Hurricane Resistant Solutions and More Cancer Center of Sacred Heart Hospital, Pensacola, Florida Architect: Caldwell Associates Architects, Pensacola, Florida Customer: Merritt Glass Co, Inc., Pensacola, Florida Photo: © CJ Berg Photographics Kawneer provides a single-source solution to the growing need for hurricane resistant products in the east and Gulf Coast states from New York through Texas. IR 500/501 Series Framing Systems and 350/500 IR Entrances are large missile impact resistant, fully tested and easy to fabricate and install. In addition, IR 501T and IR 501UT framing provides improved thermal performance to increase energy efficiency by employing IsoLock™ thermal breaks. IR 500/501 Series Framing Systems Our hurricane resistant framing systems are designed and engineered for single-span storefronts, low- to mid-rise ribbon window and punched opening applications. Testing IR 500/501 Framing Systems are tested to high velocity hurricane zone requirements of the international building code and Florida building code, which meet ASTM E 1886 and TAS 201 and TAS 203 for impact and cycle pressure differentials. Additionally, all of our systems have been tested to ASTM E 331, ASTM E 283 and ASTM E 330 for air, water and structural performance. For thermal and acoustical performance, IR 501UT has been tested to AAMA 1503, AAMA 1801 and ASTM E 1425. Fabrication 350/500 IR Entrances All the IR 500/501 Series Framing Systems offer a flush glazed look with either interior structural silicone seal (wet glazed) or optional EPDM gasket (dry glazed) for large missile applications. Screw spline fabrication provides the option to pre-assemble units with controlled shop labor costs and smaller field crews. The framing systems are center glazed from the exterior side and are designed to accept 350/500 IR Entrances. Entrances are 1-3/4" (44.45 mm) deep and provide the extra strength for applications where more stringent code requirements call for windborne debris protection. IR 500 IR 501 IR 501T IR 501UT Sightline 2-1/2" (63.5 mm) 2-1/2" (63.5 mm) 2-3/4" (69.85 mm) 2-3/4" (69.85 mm) System Depth 5" (127 mm) 5" (127 mm) 5" (127 mm) 5" (127 mm) Infill Options 9/16", 5/8" (Impact), 1/4" (Non-Impact) 1-5/16" (Impact), 1" (Non-Impact) 1-5/16" (Impact) 1-5/16" (Impact) Thermal No No IsoLock™ Thermal Break Dual IsoLock™ Thermal Break Hurricane Resistant Tested Large Missile Small Missile Large Missile Small Missile Large Missile Small Missile Large Missile Typical Detail Testing 350/500 IR Entrances are tested to the High Velocity Hurricane Zone requirements of the International Building Code and Florida Building Code. Meeting ASTM E 1886, and TAS 201 and TAS 203 for impact and cycle pressure differentials. Features 350 IR Entrances feature standard 3-1/2" (88.9 mm) vertical stiles, 3-1/2" (88.9 mm) top rails and 6-1/2" (165.1 mm) bottom rails. 500 IR Entrances feature standard 5" (127 mm) vertical stiles, 5" (127 mm) top rails and 6-1/2" (165.1 mm) bottom rails. Bottom rail options are 7-1/2" (190.5 mm) and 10" (254 mm) for aesthetics or applications where higher bottom rails are required to meet local building codes. 350/500 IR Entrances are single acting and available in singles or pairs to suit any project. The entrances feature the proven Dual Moment welded corner construction with 16 welds per door and Kawneer’s Limited Lifetime Warranty. Standard hinging hardware includes top, bottom and intermediate offset pivots, 1-1/2 pair of butt hinges or continuous geared hinges. Standard MS 1850 threepoint locks are available as well as concealed vertical rod exit device hardware options. Tarpon Springs Public Safety Building, Tarpon Springs, Florida Architect: Gee & Jenson, Engineers, Architects, Planners, Inc., West Palm Beach, Florida Glazing Contractor: Ashe Glass & Mirror, Temple Terrace, Florida Photo © Gordon Schenck, Jr. Entrances accommodate 1/4", 7/16" and 9/16" impact resistant glazing infills using square glass stops with an interior silicone seal. Additional glazing options include 3M VHB Structural Glazing Tape and dry/dry glazing gaskets. Pairs include an adjustable astragal, utilizing pile weathering with a polymeric fin at the meeting stiles, and all doors include an EPDM blade gasket at the threshold. Polymeric bulb weather stripping is used in the door frames. Standard door jambs, transom bars and headers from the IR 500/501 Series Framing Systems are designed for use with 350/500 IR Entrances. Optional door frames include Trifab™ VG 450 center glazed, Trifab™ VG 451 center glazed, and 1600 Wall System™ sub-frames. L-R: IR 500, IR 501UT and IR 501 Framing Kawneer Company, Inc. Technology Park / Atlanta 555 Guthridge Court Norcross, GA 30092 kawneer.com 770 . 449 . 5555 © Kawneer Company, Inc. 2015 LITHO IN U.S.A. Form No. 15-2206 Trifab™ VG 450, Trifab™ VG 451, IsoLock™ and 1600 Wall System™ are trademarks of Kawneer Company, Inc. and Alcoa Inc. IR 500/501 FEBRUARY, 2012 EC 97911-37 FEATURES HURRICANE RESISTANT PRODUCT Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Features • • • • • • • • IR 500/501 is 5" (127) deep and has a 2-1/2" (63.5) sightline {Expansion mullions have a 2-3/4" (69.9) sightline} Screw Spline fabrication Center glazed Outside glazed with internal silicone seal IR 500 glazing options are 9/16", (14.3) 5/8" (15.9) and 1/4" (6.4) (non-impact) IR 501 glazing options are 1-5/16" (33.3) and 1" (25.4) (non-impact) Permanodic® anodized finishes in 7 choices Painted finishes in standard and custom choices Optional Features • Integrated entrance framing • 350 IR Medium Stile - single or pairs of entrances • • • • Impact resistant Storefront, ribbom window or punched opening Low to mid-rise Single span © Kawneer Company, Inc., 2012 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Product Applications For specific product applications, Consult your Kawneer representative. kawneer.com 1 kawneer.com © Kawneer Company, Inc., 2012 BLANK PAGE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. IR 500/501 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 FEBRUARY, 2012 EC 97911-37 HURRICANE RESISTANT PRODUCT IR 500/501 FEBRUARY, 2012 EC 97911-37 3 INDEX IR 500 BASIC FRAMING DETAILS...................................................... 4 IR 500 ENTRANCE FRAMING DETAILS............................................. 5 IR 501 BASIC FRAMING DETAILS...................................................... 6 IR 501 ENTRANCE FRAMING DETAILS............................................. 7 IR 500 MISCELLANEOUS FRAMING.................................................. 8 IR 501 MISCELLANEOUS FRAMING.................................................. 9 IR 500 WINDLOAD CHARTS ........................................................ 10-13 IR 501 WINDLOAD CHARTS ....................................................... 14, 15 IR 500 / 501 DEADLOAD CHARTS............................................... 16-18 IR 501 THERMAL CHARTS........................................................... 19-22 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. The following metric (SI) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal © Kawneer Company, Inc., 2012 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. HURRICANE RESISTANT PRODUCT Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com IR 500 4 DECEMBER, 2011 EC 97911-37 BASIC FRAMING DETAILS HURRICANE RESISTANT PRODUCT 1 6 4 8 8 5 4 7 7 2 9 3 9 ELEVATION IS NUMBER KEYED TO DETAILS 5/8" infill 9/16" infill 575-001 575-001 575-001 575-013 2-1/2" (63.5) 5 VERTICAL 4 JAMB 2-1/2" (63.5) 2-1/2" (63.5) 4 JAMB 5 VERTICAL 4 JAMB Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 5 VERTICAL 575-002 575-002 575-002 5" (69.85) 2-1/2" (63.5) 575-013 5" (69.85) 575-013 9/16" INFILL (DRY-GLAZED) 575-012 575-012 575-012 5" (69.85) 5" (69.85) 1 HEAD 1 HEAD 575-011 575-004 575-004 575-004 575-157 3 SILL 2 HORIZONTAL 575-058 575-057 575-004 575-157 3 SILL 575-011 575-004 2 HORIZONTAL 575-058 575-057 575-011 575-004 2 HORIZONTAL 1 HEAD 575-058 575-057 575-157 3 SILL kawneer.com © Kawneer Company, Inc., 2010 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SCALE 3" = 1'-0" IR 500 DECEMBER, 2011 EC 97911-37 ENTRANCE FRAMING DETAILS HURRICANE RESISTANT PRODUCT SCALE 3" = 1'-0" 5/8" infill 9/16" infill 575-035 575-035 575-033 6 DOOR JAMB AT TRANSOM 6 DOOR JAMB AT TRANSOM 575-051 575-035 575-035 575-022 © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 575-051 7 DOOR JAMB 7 DOOR JAMB 575-004 575-004 575-022 7 DOOR JAMB 575-004 575-022 8 DOOR WITH TRANSOM 8 DOOR WITH TRANSOM 8 DOOR WITH TRANSOM 9 BOTTOM RAIL 9 BOTTOM RAIL 9 BOTTOM RAIL 200-795 kawneer.com 575-033 6 DOOR JAMB AT TRANSOM 575-051 575-035 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 575-033 575-051 (Mod.) 575-035 575-051 (Mod.) 575-051 (Mod.) 069-139 9/16" INFILL (DRY-GLAZED) 200-795 200-795 069-139 069-139 5 1 6 4 1-5/16" infill 575-101 575-116 2-1/2" (63.5) 4 JAMB 5 VERTICAL 575-112 575-104 575-115 575-104 575-159 575-158 3 SILL 8 5 4 2 7 7 3 9 1 HEAD 2 HORIZONTAL 9 ELEVATIONS ARE NUMBER KEYED TO DETAILS 1-5/16" INFILL (DRY GLAZED) 575-101 575-116 2-1/2" (63.5) 4 JAMB 575-112 1 HEAD 575-104 575-115 2 HORIZONTAL 575-104 575-159 575-158 575-157 575-157 3 SILL kawneer.com © Kawneer Company, Inc., 2010 BASIC FRAMING DETAILS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. IR 501 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 5" (69.85) SCALE 3" = 1'-0" 575-102 575-102 5" (69.85) 6 DECEMBER, 2011 EC 97911-37 HURRICANE RESISTANT PRODUCT 1 8 5 VERTICAL © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. kawneer.com 575-135 575-135 575-135 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 575-133 575-104 069-139 575-135 DECEMBER, 2011 IR 501 EC 97911-37 ENTRANCE FRAMING DETAILS HURRICANE RESISTANT PRODUCT SCALE 3" = 1'-0" 1-5/16" infill 1-5/16" INFILL (DRY GLAZED) 575-051 (Mod.) 575-051 (Mod.) 6 DOOR JAMB AT TRAMSOM 575-051 575-122 575-133 6 DOOR JAMB AT TRAMSOM 575-051 7 DOOR JAMB 7 DOOR JAMB 575-104 200-795 069-139 575-122 8 DOOR WITH TRANSOM 8 DOOR WITH TRANSOM 9 BOTTOM RAIL 9 BOTTOM RAIL 200-795 7 575-064 575-006 575-065 575-004 575-007 575-003 OPTIONAL RADIUS HEAD 575-004 575-003 575-006 575-037 575-037 OPTIONAL HEAD & SILL (FOR CONCEALED PERIMETER FASTENERS) 575-010 575-009 2-3/4" (69.6) EXPANSION MULLION 1/4" INFILL (NON-IMPACT) GLAZING ADAPTOR 575-036 575-036 575-012 575-001 STRAP ANCHORS kawneer.com © Kawneer Company, Inc., 2010 MISCELLANEOUS FRAMING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. IR 500 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 575-004 575-007 575-044 575-004 575-029 8 DECEMBER, 2011 EC 97911-37 HURRICANE RESISTANT PRODUCT SCALE 3" = 1'-0" 575-063 575-013 © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. EC 97911-37 575-164 OPTIONAL HEAD WITH STOP 575-118 kawneer.com 575-117 EXPANSION MULLION 575-036 575-036 575-112 575-101 STRAP ANCHORS 451-VG-030 575-102 575-104 451-VG-030 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2011 IR 501 MISCELLANEOUS FRAMING HURRICANE RESISTANT PRODUCT SCALE 3" = 1'-0" 575-163 575-065 575-103 OPTIONAL RADIUS HEAD 575-116 2-3/4" (69.6) 1" INFILL (NON-IMPACT) GLAZING ADAPTOR 9 IR 500 10 DECEMBER, 2011 WINDLOAD CHARTS EC 97911-37 HURRICANE RESISTANT PRODUCT 575-013 & 575-002 WITHOUT HORIZONTALS A = 40 PSF (1920) B = 50 PSF (2400) C = 60 PSF (2880) D = 70 PSF (3360) E = 80 PSF (3840) F = 90 PSF (4320) 16 15 WIDTH IN METERS 1.0 2.0 16 15 14 14 4.0 13 10 3.0 A 9 B C D E F 2.0 8 7 HEIGHT IN FEET 11 A 3.0 B C D E F 10 9 8 7 6 2.0 6 5 5 4 1.0 1 2 3 4 5 6 7 8 WIDTH IN FEET 575-013/575-002 4 IA = 8.422 in4 (350.55 x 104 mm4) SA = 3.363 in3 (55.11 x 103 mm3) 3 1.0 1 2 3 4 5 6 7 8 WIDTH IN FEET 575-013 & 575-002 AND 575-110 STEEL WITH HORIZONTALS 575-013 & 575-002 AND 575-110 STEEL WITHOUT HORIZONTALS WIDTH IN METERS 1.0 2.0 WIDTH IN METERS 1.0 2.0 16 16 15 15 14 4.0 13 12 A 10 B C D E F 9 8 7 3.0 HEIGHT IN FEET 11 HEIGHT IN METERS 12 10 9 8 575-013/575-002 AND 575-110 STEEL 6 5 IA = 8.422 in4 (350.55 x 104 mm4) SA = 3.363 in3 (55.11 x 103 mm3) 5 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 8 B C D 3.0 E F 7 2.0 4 A 11 6 3 4.0 13 IS = 1.729 in4 (71.97 x 104 mm4) SS = 0.808 in3 (13.24 x 103 mm3) HEIGHT IN METERS 14 HEIGHT IN FEET 11 HEIGHT IN METERS 12 HEIGHT IN METERS HEIGHT IN FEET 12 3 4.0 13 2.0 4 3 1.0 1 2 3 4 5 6 7 8 WIDTH IN FEET kawneer.com © Kawneer Company, Inc., 2010 WIDTH IN METERS 1.0 2.0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 575-013 & 575-002 WITH HORIZONTALS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH and WITHOUT HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable windload stress for ALUMINUM 15,152 p.s.i. (104MPa). STEEL 20,000 p.s.i. (138MPa.) Charted curves, in all cases are for the limiting value. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. IR 500 DECEMBER, 2011 EC 97911-37 11 WINDLOAD CHARTS WIDTH IN METERS 1.0 2.0 16 16 15 14 14 4.0 11 10 A B C D E F 9 8 7 3.0 12 HEIGHT IN FEET 12 11 A 10 B C D E F 9 8 7 2.0 6 3.0 2.0 6 5 5 575-009/575-010 1 2 3 4 5 6 WIDTH IN FEET 7 4 IA = 9.086 in4 (378.19 x 104 mm4) SA = 3.627 in3 (59.44 x 103 mm3) 1.0 8 3 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 8 575-009 & 575-010 AND 575-110 STEEL WITH HORIZONTALS 575-009 & 575-010 AND 575-110 STEEL WITHOUT HORIZONTALS WIDTH IN METERS 1.0 2.0 WIDTH IN METERS 1.0 2.0 16 16 15 15 14 14 4.0 A 10 B C D E F 9 8 7 3.0 HEIGHT IN FEET 11 12 HEIGHT IN METERS 12 10 9 8 6 575-009/575-010 AND 575-110 STEEL 6 5 IA = 9.086 in4 (378.19 x 104 mm4) SA = 3.627 in3 (59.44 x 103 mm3) 5 3 1.0 1 kawneer.com 2 3 4 5 6 WIDTH IN FEET 7 8 A B C D 3.0 E F 11 7 2.0 4 4.0 13 IS = 1.729 in4 (71.97 x 104 mm4) SS = 0.808 in3 (13.24 x 103 mm3) 2.0 4 3 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 8 HEIGHT IN METERS 4 HEIGHT IN FEET 4.0 13 HEIGHT IN METERS 13 13 © Kawneer Company, Inc., 2010 WIDTH IN METERS 1.0 2.0 15 3 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 575-009 & 575-010 WITHOUT HORIZONTALS A = 40 PSF (1920) B = 50 PSF (2400) C = 60 PSF (2880) D = 70 PSF (3360) E = 80 PSF (3840) F = 90 PSF (4320) HEIGHT IN METERS 575-009 & 575-010 WITH HORIZONTALS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. HURRICANE RESISTANT PRODUCT IR 500 12 DECEMBER, 2011 WINDLOAD CHARTS EC 97911-37 16 15 15 14 14 4.0 11 10 3.0 A 9 B C D E F 2.0 8 7 6 12 HEIGHT IN FEET 12 A 3.0 10 B C D E F 9 8 2.0 6 5 575-050/575-035 1 2 3 4 5 6 WIDTH IN FEET 7 4 IA = 8.209 in4 (341.68 x 104 mm4) SA = 3.049 in3 (49.96 x 103 mm3) 1.0 8 3 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 8 575-050 & 575-035 AND 575-111 STEEL WITH HORIZONTALS 575-050 & 575-035 AND 575-111 STEEL WITHOUT HORIZONTALS WIDTH IN METERS 1.0 2.0 WIDTH IN METERS 1.0 2.0 16 16 15 15 14 14 4.0 A 11 B C 3.0 D E F 10 9 8 7 9 8 575-050/575-035 AND 575-111 STEEL 6 5 IA = 8.209 in4 (341.68 x 104 mm4) SA = 3.049 in3 (49.96 x 103 mm3) 5 3 1 2 3 4 5 6 WIDTH IN FEET 7 8 C D E 3.0 F 10 6 1.0 B 11 7 2.0 4 A 12 HEIGHT IN FEET 12 4.0 13 HEIGHT IN METERS 13 IS = 1. 729 in4 (71.97 x 104 mm4) SS = 0. 808 in3 (13.24 x 103 mm3) HEIGHT IN METERS 4 HEIGHT IN FEET 11 7 5 3 4.0 13 HEIGHT IN METERS 13 2.0 4 3 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 8 kawneer.com © Kawneer Company, Inc., 2010 16 WIDTH IN METERS 1.0 2.0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. WIDTH IN METERS 1.0 2.0 HEIGHT IN FEET 575-050 & 575-035 WITHOUT HORIZONTALS A = 40 PSF (1920) B = 50 PSF (2400) C = 60 PSF (2880) D = 70 PSF (3360) E = 80 PSF (3840) F = 90 PSF (4320) HEIGHT IN METERS 575-050 & 575-035 WITH HORIZONTALS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. HURRICANE RESISTANT PRODUCT IR 500 DECEMBER, 2011 EC 97911-37 13 WINDLOAD CHARTS WIDTH IN METERS 1.0 2.0 16 16 15 14 14 4.0 11 10 3.0 A 9 B C D E F 2.0 8 7 6 12 HEIGHT IN FEET 12 4 3 4 5 6 WIDTH IN FEET 7 A 10 B C D E F 9 8 575-051/575-035 6 IA = 8.233 in4 (342.68 x 104 mm4) SA = 3.177 in3 (52.06 x 103 mm3) 5 3.0 2.0 4 1.0 2 11 7 5 1 4.0 13 HEIGHT IN METERS 13 3 8 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 8 575-051 & 575-035 AND 575-111 STEEL WITH HORIZONTALS 575-051 & 575-035 AND 575-111 STEEL WITHOUT HORIZONTALS WIDTH IN METERS 1.0 2.0 WIDTH IN METERS 1.0 2.0 16 15 15 14 14 4.0 11 B C 10 D E F 9 3.0 8 7 10 9 8 6 575-051/575-035 AND 575-111 STEEL 6 5 IA = 8.233 in4 (342.68 x 104 mm4) SA = 3.177 in3 (52.06 x 103 mm3) 5 3 1.0 1 kawneer.com 2 3 4 5 6 WIDTH IN FEET 7 8 B C D E 3.0 F 11 7 2.0 4 A 12 HEIGHT IN FEET A HEIGHT IN METERS HEIGHT IN FEET 12 4.0 13 IS = 2.946 in4 (122.62 x 104 mm4) SS = 1.473 in3 (24.14 x 103 mm3) 2.0 4 3 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 8 HEIGHT IN METERS 16 13 © Kawneer Company, Inc., 2010 WIDTH IN METERS 1.0 2.0 15 3 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 575-051 & 575-035 WITHOUT HORIZONTALS A = 40 PSF (1920) B = 50 PSF (2400) C = 60 PSF (2880) D = 70 PSF (3360) E = 80 PSF (3840) F = 90 PSF (4320) HEIGHT IN METERS 575-051 & 575-035 WITH HORIZONTALS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. HURRICANE RESISTANT PRODUCT IR 501 14 DECEMBER, 2011 WINDLOAD CHARTS EC 97911-37 16 15 15 14 14 4.0 11 10 A 9 B C D E F 8 7 3.0 12 HEIGHT IN FEET 12 9 8 2.0 5 575-116/575-102 1 2 3 4 5 6 WIDTH IN FEET 7 4 IA = 8.612 in4 (358.46 x 104 mm4) SA = 3.472 in3 (56.90 x 103 mm3) 1.0 8 3 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 575-117 & 575-118 WITH HORIZONTALS 575-117 & 575-118 WITHOUT HORIZONTALS WIDTH IN METERS 1.0 2.0 WIDTH IN METERS 1.0 2.0 16 16 15 15 14 14 4.0 11 10 A 9 3.0 B C D E F 8 7 12 HEIGHT IN FEET 12 4.0 13 HEIGHT IN METERS 13 8 11 A 10 B C D E F 9 8 7 2.0 6 3.0 HEIGHT IN METERS 4 2.0 6 5 5 575-117/575-118 4 3 A 3.0 B C D E F 10 6 5 HEIGHT IN FEET 11 7 2.0 6 3 4.0 13 HEIGHT IN METERS 13 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 8 IA = 9.285 in4 (386.47 x 104 mm4) SA = 3.704 in3 (60.70 x 103 mm3) 4 3 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 8 kawneer.com © Kawneer Company, Inc., 2010 16 WIDTH IN METERS 1.0 2.0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. WIDTH IN METERS 1.0 2.0 HEIGHT IN FEET 575-116 & 575-102 WITHOUT HORIZONTALS A = 40 PSF (1920) B = 50 PSF (2400) C = 60 PSF (2880) D = 70 PSF (3360) E = 80 PSF (3840) F = 90 PSF (4320) HEIGHT IN METERS 575-116 & 575-102 WITH HORIZONTALS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. HURRICANE RESISTANT PRODUCT IR 501 DECEMBER, 2011 EC 97911-37 15 WINDLOAD CHARTS WIDTH IN METERS 1.0 2.0 16 16 15 14 14 4.0 11 10 3.0 A B C D E F 2.0 9 8 7 12 HEIGHT IN FEET 12 A 3.0 10 B C D E F 9 8 2.0 6 5 5 575-050/575-135 1 2 3 4 5 6 7 4 IA = 8.371 in4 (348.43 x 104 mm4) SA = 3.226 in3 (52.86 x 103 mm3) 1.0 8 3 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 575-051 & 575-135 WITH HORIZONTALS 575-051 & 575-135 WITHOUT HORIZONTALS WIDTH IN METERS 1.0 2.0 WIDTH IN METERS 1.0 2.0 16 16 15 15 14 14 4.0 11 10 3.0 A 9 B C D E F 2.0 8 7 12 HEIGHT IN FEET 12 4.0 13 HEIGHT IN METERS 13 8 11 A 3.0 B C D E F 10 9 8 7 6 2.0 6 5 5 575-051/575-135 4 1.0 1 kawneer.com 2 3 4 5 6 WIDTH IN FEET 7 8 IA = 8.393 in4 (349.34 x 104 mm4) SA = 3.255 in3 (53.34 x 103 mm3) 4 3 1.0 1 2 3 4 5 6 WIDTH IN FEET 7 8 HEIGHT IN METERS 4 HEIGHT IN FEET 11 7 6 3 4.0 13 HEIGHT IN METERS 13 WIDTH IN FEET © Kawneer Company, Inc., 2010 WIDTH IN METERS 1.0 2.0 15 3 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 575-050 & 575-135 WITHOUT HORIZONTALS A = 40 PSF (1920) B = 50 PSF (2400) C = 60 PSF (2880) D = 70 PSF (3360) E = 80 PSF (3840) F = 90 PSF (4320) HEIGHT IN METERS 575-050 & 575-135 WITH HORIZONTALS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. HURRICANE RESISTANT PRODUCT IR 500/501 16 FEBRUARY, 2012 DEADLOAD CHARTS EC 97911-37 HURRICANE RESISTANT PRODUCT Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 9/16" or 5/8" thick impact resistant glass or 1-5/16" thick insulated impact resistant glass supported on two setting blocks placed at the loading points shown. 575-011 575-115 WIDTH IN METERS WIDTH IN METERS 1.0 2.0 16 16 15 15 14 14 12 11 11 9 8 2.0 10 8 7 6 6 5 5 4 C 3 B 2 A 1 2 3 4 5 6 WIDTH IN FEET 7 8 3.0 9 2.0 4 1.0 C 1.0 3 B 2 575-011 (IR 500) I = 1.043 in4 (43.41 x 104 mm4) S = 0.697 in3 (11.42 x 103 mm3) 1 A 1 2 3 4 5 6 WIDTH IN FEET 7 8 575-115 (IR 501) I = 0.929 in4 (38.67 x 104 mm4) S = 0.620 in3 (10.16 x 103 mm3) kawneer.com © Kawneer Company, Inc., 2012 7 HEIGHT IN FEET 3.0 HEIGHT IN METERS HEIGHT IN FEET 12 10 4.0 13 HEIGHT IN METERS 4.0 13 1 2.0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1.0 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = (1/4 POINT LOADING) B = (1/6 POINT LOADING) C = (1/8 POINT LOADING) IR 500/501 FEBRUARY, 2012 EC 97911-37 DEADLOAD CHARTS HURRICANE RESISTANT PRODUCT DEADLOADS ON ENTRANCE TRANSOM BARS Height limitations for transom glass over a doorway are based on a 1/16" (1.6) maximum allowable deflection at the center of a transom bar. The accompanying chart is calculated for 9/16" or 5/8" thick impact resistant glass or 1-5/16" thick insulated impact resistant glass supported on two setting blocks placed at the loading points shown. 15 14 14 4.0 13 12 11 11 9 8 7 2.0 HEIGHT IN FEET 3.0 HEIGHT IN METERS 12 10 10 3.0 9 8 7 2.0 6 6 5 5 4 4 C 3 B 2 A 1.0 3 1 2 3 4 5 6 7 WIDTH IN FEET 8 C B A 575-022 (IR 500) I = 1.248 in4 (51.95 x 104 mm4) S = 0.777 in3 (12.73 x 103 mm3) 575-023 HORIZONTAL WIDTH IN METERS 1.0 2.0 16 15 14 4.0 13 11 10 3.0 9 8 7 C2.0 HEIGHT IN METERS 12 HEIGHT IN FEET 4.0 13 6 B 5 4 A 3 1.0 2 1 1 2 3 4 5 6 WIDTH IN FEET kawneer.com 7 8 575-023 (IR 500) I = 1.764 in4 (73.42 x 104 mm4) S = 1.081 in3 (17.71 x 103 mm3) 1 1 2 3 4 5 6 WIDTH IN FEET 7 8 HEIGHT IN METERS 16 15 1 © Kawneer Company, Inc., 2012 WIDTH IN METERS 1.0 2.0 16 2 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 575-122 HORIZONTAL A = (1/4 POINT LOADING) B = (1/6 POINT LOADING) C = (1/8 POINT LOADING) WIDTH IN METERS 1.0 2.0 HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 575-022 HORIZONTAL 1.0 575-122 (IR 501) I = 1.177 in4 (48.99 x 104 mm4) S = 0.722 in3 (11.83 x 103 mm3) 17 IR 500/501 18 FEBRUARY, 2012 EC 97911-37 DEADLOAD CHARTS HURRICANE RESISTANT PRODUCT 575-120 WIDTH IN METERS 2.0 1.0 16 15 15 14 14 4.0 12 12 11 11 3.0 9 8 7 2.0 HEIGHT IN FEET 10 10 8 7 6 5 5 4 1.0 2 1 2 3 4 5 6 WIDTH IN FEET 7 8 575-020 (IR 500) I = 1.148 in4 (47.78 x 104 mm4) S = 0.751 in3 (12.31 x 103 mm3) 2.0 4 C 3 B 2 A 1 1 2 3 4 5 6 WIDTH IN FEET 7 8 1.0 575-120 (IR 501) I = 1.080 in4 (44.95 x 104 mm4) S = 0.683 in3 (11.19 x 103 mm3) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 C B A 3.0 9 6 3 4.0 13 HEIGHT IN METERS HEIGHT IN FEET 13 2.0 HEIGHT IN METERS 1.0 16 575-021 WIDTH IN METERS 1.0 2.0 16 15 14 4.0 13 HEIGHT IN FEET 11 10 3.0 9 8 7 2.0 6 HEIGHT IN METERS 12 C 5 B 4 A 3 1.0 2 1 1 2 3 4 5 6 WIDTH IN FEET 7 8 575-021 (IR 500) I = 1.621 in4 (67.47 x 104 mm4) S = 1.234 in3 (20.22 x 103 mm3) kawneer.com © Kawneer Company, Inc., 2012 575-020 WIDTH IN METERS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = (1/4 POINT LOADING) B = (1/6 POINT LOADING) C = (1/8 POINT LOADING) IR 501 DECEMBER, 2011 EC 97911-37 THERMAL CHARTS HURRICANE RESISTANT PRODUCT Project Specific U-factor Example Calculation 15'-10" 2'-0" 9'-7 1/2" 7'-0" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 5'-0" Example Glass U-factor= 0.42 Btu/hr·ft2·oF Total Daylight Opening = 3(5' x 7') + 3(5' x 2') = 135ft2 Total Projected Area = (Total Daylight Opening + Total Area of Framing System) = 15'-10" x 9'-7 1/2" = 152.39ft2 Percent of Glass = (Total Daylight Opening ÷ Total Projected Area) = (135 ÷ 152.39)100 = 88% System U-factor vs Percent of Glass Area 0.80 0.70 0.65 X E COG U-factor 0.55 M 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.50 P 0.45 L 0.40 E © Kawneer Company, Inc., 2010 0.60 A 0.35 0.30 0.25 88% 70 75 80 90 85 0.20 95 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.75 Percent of Glass Based on 88% glass and center of glass (COG) U-factor of 0.42 System U-factor is equal to 0.51 Btu/hr x ft2 x oF kawneer.com 0.51 19 System U-Factor for Vision Glass COG U-factor 0.48 (2.73) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) Vision Area / Total Area (%) kawneer.com © Kawneer Company, Inc., 2010 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. IR 501 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System U-Factor (Btu/h·ft2·°F) 20 DECEMBER, 2011 EC 97911-37 HURRICANE RESISTANT PRODUCT Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. System VT © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2011 kawneer.com IR 501 EC 97911-37 COG SHGC Vision Ares / Total Area (%) Charts are generated per AAMA 507. 21 THERMAL CHARTS HURRICANE RESISTANT PRODUCT System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area Vision Area / Total Area (%) Charts are generated per AAMA 507. COG VT System Visible Transmittance (VT) vs Percent of Vision Area IR 501 DECEMBER, 2011 EC 97911-37 THERMAL PERFORMANCE MATRIX (NFRC SIZE) HURRICANE RESISTANT PRODUCT Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.65 0.46 0.63 0.44 0.62 0.42 0.60 0.40 0.59 0.38 0.57 0.36 0.56 0.34 0.54 0.32 0.52 0.30 0.51 0.28 0.49 0.26 0.48 0.24 0.46 0.22 0.45 0.20 0.43 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.66 0.75 0.65 0.70 0.62 0.70 0.60 0.65 0.58 0.65 0.56 0.60 0.53 0.60 0.52 0.55 0.49 0.55 0.47 0.50 0.45 0.50 0.43 0.45 0.40 0.45 0.39 0.40 0.36 0.40 0.34 0.35 0.32 0.35 0.30 0.30 0.27 0.30 0.26 0.25 0.23 0.25 0.22 0.20 0.19 0.20 0.17 0.15 0.15 0.15 0.13 0.10 0.10 0.10 0.09 0.05 0.06 0.05 0.04 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200. 3. Glass properties are based on center of glass values and are obtained from your glass supplier. 4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). kawneer.com © Kawneer Company, Inc., 2010 SHGC Matrix 2 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 22