IR 500-501 Framing

IR 500/501 Series Framing Systems
and 350/500 IR Entrances
Single-Source
Hurricane Resistant
Solutions and More
Cancer Center of Sacred Heart Hospital, Pensacola, Florida
Architect: Caldwell Associates Architects, Pensacola, Florida
Customer: Merritt Glass Co, Inc., Pensacola, Florida
Photo: © CJ Berg Photographics
Kawneer provides a single-source solution to the growing need for
hurricane resistant products in the east and Gulf Coast states from
New York through Texas. IR 500/501 Series Framing Systems and
350/500 IR Entrances are large missile impact resistant, fully tested
and easy to fabricate and install. In addition, IR 501T and IR 501UT
framing provides improved thermal performance to increase energy
efficiency by employing IsoLock™ thermal breaks.
IR 500/501 Series Framing Systems
Our hurricane resistant framing systems are designed and engineered
for single-span storefronts, low- to mid-rise ribbon window and
punched opening applications.
Testing
IR 500/501 Framing Systems are tested to high velocity hurricane
zone requirements of the international building code and Florida
building code, which meet ASTM E 1886 and TAS 201 and TAS 203
for impact and cycle pressure differentials. Additionally, all of our
systems have been tested to ASTM E 331, ASTM E 283 and ASTM E
330 for air, water and structural performance.
For thermal and acoustical performance, IR 501UT has been tested to
AAMA 1503, AAMA 1801 and ASTM E 1425.
Fabrication
350/500 IR Entrances
All the IR 500/501 Series Framing Systems offer a flush glazed look
with either interior structural silicone seal (wet glazed) or optional
EPDM gasket (dry glazed) for large missile applications. Screw spline
fabrication provides the option to pre-assemble units with controlled
shop labor costs and smaller field crews. The framing systems are
center glazed from the exterior side and are designed to accept
350/500 IR Entrances.
Entrances are 1-3/4" (44.45 mm) deep and
provide the extra strength for applications
where more stringent code requirements call
for windborne debris protection.
IR 500
IR 501
IR 501T
IR 501UT
Sightline
2-1/2" (63.5 mm)
2-1/2" (63.5 mm)
2-3/4" (69.85 mm) 2-3/4" (69.85 mm)
System Depth
5" (127 mm)
5" (127 mm)
5" (127 mm)
5" (127 mm)
Infill Options
9/16", 5/8"
(Impact), 1/4"
(Non-Impact)
1-5/16"
(Impact), 1"
(Non-Impact)
1-5/16" (Impact)
1-5/16" (Impact)
Thermal
No
No
IsoLock™
Thermal Break
Dual IsoLock™
Thermal Break
Hurricane
Resistant
Tested
Large Missile
Small Missile
Large Missile
Small Missile
Large Missile
Small Missile
Large Missile
Typical Detail
Testing
350/500 IR Entrances are tested to the High Velocity Hurricane Zone
requirements of the International Building Code and Florida Building
Code. Meeting ASTM E 1886, and TAS 201 and TAS 203 for impact
and cycle pressure differentials.
Features
350 IR Entrances feature standard 3-1/2" (88.9 mm)
vertical stiles, 3-1/2" (88.9 mm) top rails and 6-1/2"
(165.1 mm) bottom rails. 500 IR Entrances feature
standard 5" (127 mm) vertical stiles, 5" (127 mm) top
rails and 6-1/2" (165.1 mm) bottom rails. Bottom rail
options are 7-1/2" (190.5 mm) and 10" (254 mm) for
aesthetics or applications where higher bottom rails
are required to meet local building codes. 350/500 IR
Entrances are single acting and available in singles
or pairs to suit any project. The entrances feature the
proven Dual Moment welded corner construction
with 16 welds per door and Kawneer’s Limited
Lifetime Warranty.
Standard hinging hardware includes top, bottom and
intermediate offset pivots, 1-1/2 pair of butt hinges or
continuous geared hinges. Standard MS 1850 threepoint locks are available as well as concealed vertical
rod exit device hardware options.
Tarpon Springs Public Safety Building, Tarpon Springs, Florida
Architect: Gee & Jenson, Engineers, Architects, Planners, Inc.,
West Palm Beach, Florida
Glazing Contractor: Ashe Glass & Mirror, Temple Terrace, Florida
Photo © Gordon Schenck, Jr.
Entrances accommodate 1/4", 7/16" and 9/16" impact resistant
glazing infills using square glass stops with an interior silicone seal.
Additional glazing options include 3M VHB Structural Glazing Tape
and dry/dry glazing gaskets. Pairs include an adjustable astragal,
utilizing pile weathering with a polymeric fin at the meeting stiles,
and all doors include an EPDM blade gasket at the threshold.
Polymeric bulb weather stripping is used in the door frames.
Standard door jambs, transom bars and headers from the
IR 500/501 Series Framing Systems are designed for use with
350/500 IR Entrances. Optional door frames include Trifab™ VG
450 center glazed, Trifab™ VG 451 center glazed, and 1600 Wall
System™ sub-frames.
L-R: IR 500, IR 501UT and IR 501 Framing
Kawneer Company, Inc.
Technology Park / Atlanta
555 Guthridge Court
Norcross, GA 30092
kawneer.com
770 . 449 . 5555
© Kawneer Company, Inc. 2015 LITHO IN U.S.A. Form No. 15-2206
Trifab™ VG 450, Trifab™ VG 451, IsoLock™ and 1600 Wall System™ are trademarks of Kawneer Company, Inc. and Alcoa Inc.
IR 500/501
FEBRUARY, 2012
EC 97911-37
FEATURES
HURRICANE RESISTANT PRODUCT
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Features
•
•
•
•
•
•
•
•
IR 500/501 is 5" (127) deep and has a 2-1/2" (63.5) sightline
{Expansion mullions have a 2-3/4" (69.9) sightline}
Screw Spline fabrication
Center glazed
Outside glazed with internal silicone seal
IR 500 glazing options are 9/16", (14.3) 5/8" (15.9) and
1/4" (6.4) (non-impact)
IR 501 glazing options are 1-5/16" (33.3) and 1" (25.4) (non-impact)
Permanodic® anodized finishes in 7 choices
Painted finishes in standard and custom choices
Optional Features
• Integrated entrance framing
• 350 IR Medium Stile - single or pairs of entrances
•
•
•
•
Impact resistant
Storefront, ribbom window or punched opening
Low to mid-rise
Single span
© Kawneer Company, Inc., 2012
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Product Applications
For specific product applications,
Consult your Kawneer representative.
kawneer.com
1
kawneer.com
© Kawneer Company, Inc., 2012
BLANK PAGE
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
IR 500/501
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2
FEBRUARY, 2012
EC 97911-37
HURRICANE RESISTANT PRODUCT
IR 500/501
FEBRUARY, 2012
EC 97911-37
3
INDEX
IR 500 BASIC FRAMING DETAILS...................................................... 4
IR 500 ENTRANCE FRAMING DETAILS............................................. 5
IR 501 BASIC FRAMING DETAILS...................................................... 6
IR 501 ENTRANCE FRAMING DETAILS............................................. 7
IR 500 MISCELLANEOUS FRAMING.................................................. 8
IR 501 MISCELLANEOUS FRAMING.................................................. 9
IR 500 WINDLOAD CHARTS ........................................................ 10-13
IR 501 WINDLOAD CHARTS ....................................................... 14, 15
IR 500 / 501 DEADLOAD CHARTS............................................... 16-18
IR 501 THERMAL CHARTS........................................................... 19-22
LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED
ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT
CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR
GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR.
Metric (SI) conversion figures are included throughout these details for reference.
Numbers in parentheses ( ) are millimeters unless otherwise noted.
The following metric (SI) units are found in these details:
m –meter
cm – centimeter
mm –millimeter
s –second
Pa –pascal
MPa –megapascal
© Kawneer Company, Inc., 2012
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
HURRICANE RESISTANT PRODUCT
Kawneer reserves the right to change configurations without prior notice when deemed necessary
for product improvement.
kawneer.com
IR 500
4
DECEMBER, 2011
EC 97911-37
BASIC FRAMING DETAILS
HURRICANE RESISTANT PRODUCT
1
6
4
8
8
5
4
7
7
2
9
3
9
ELEVATION IS NUMBER KEYED TO DETAILS
5/8" infill
9/16" infill
575-001
575-001
575-001
575-013
2-1/2"
(63.5)
5
VERTICAL
4
JAMB
2-1/2"
(63.5)
2-1/2"
(63.5)
4
JAMB
5
VERTICAL
4
JAMB
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
5
VERTICAL
575-002
575-002
575-002
5"
(69.85)
2-1/2"
(63.5)
575-013
5"
(69.85)
575-013
9/16" INFILL (DRY-GLAZED)
575-012
575-012
575-012
5"
(69.85)
5"
(69.85)
1
HEAD
1
HEAD
575-011
575-004
575-004
575-004
575-157
3
SILL
2
HORIZONTAL
575-058
575-057
575-004
575-157
3
SILL
575-011
575-004
2
HORIZONTAL
575-058
575-057
575-011
575-004
2
HORIZONTAL
1
HEAD
575-058
575-057
575-157
3
SILL
kawneer.com
© Kawneer Company, Inc., 2010
1
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
SCALE 3" = 1'-0"
IR 500
DECEMBER, 2011
EC 97911-37
ENTRANCE FRAMING DETAILS
HURRICANE RESISTANT PRODUCT
SCALE 3" = 1'-0"
5/8" infill
9/16" infill
575-035
575-035
575-033
6
DOOR JAMB AT TRANSOM
6
DOOR JAMB AT TRANSOM
575-051
575-035
575-035
575-022
© Kawneer Company, Inc., 2010
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
575-051
7
DOOR JAMB
7
DOOR JAMB
575-004
575-004
575-022
7
DOOR JAMB
575-004
575-022
8
DOOR WITH
TRANSOM
8
DOOR WITH
TRANSOM
8
DOOR WITH
TRANSOM
9
BOTTOM RAIL
9
BOTTOM RAIL
9
BOTTOM RAIL
200-795
kawneer.com
575-033
6
DOOR JAMB AT TRANSOM
575-051
575-035
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
575-033
575-051 (Mod.)
575-035
575-051 (Mod.)
575-051 (Mod.)
069-139
9/16" INFILL (DRY-GLAZED)
200-795
200-795
069-139
069-139
5
1
6
4
1-5/16" infill
575-101
575-116
2-1/2"
(63.5)
4
JAMB
5
VERTICAL
575-112
575-104
575-115
575-104
575-159
575-158
3
SILL
8
5
4
2
7
7
3
9
1
HEAD
2
HORIZONTAL
9
ELEVATIONS ARE NUMBER KEYED TO DETAILS
1-5/16" INFILL (DRY GLAZED)
575-101
575-116
2-1/2"
(63.5)
4
JAMB
575-112
1
HEAD
575-104
575-115
2
HORIZONTAL
575-104
575-159
575-158
575-157
575-157
3
SILL
kawneer.com
© Kawneer Company, Inc., 2010
BASIC FRAMING DETAILS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
IR 501
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
5"
(69.85)
SCALE 3" = 1'-0"
575-102
575-102
5"
(69.85)
6
DECEMBER, 2011
EC 97911-37
HURRICANE RESISTANT PRODUCT
1
8
5
VERTICAL
© Kawneer Company, Inc., 2010
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
kawneer.com
575-135
575-135
575-135
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
575-133
575-104
069-139
575-135
DECEMBER, 2011
IR 501
EC 97911-37
ENTRANCE FRAMING DETAILS
HURRICANE RESISTANT PRODUCT
SCALE 3" = 1'-0"
1-5/16" infill
1-5/16" INFILL (DRY GLAZED)
575-051 (Mod.)
575-051 (Mod.)
6
DOOR JAMB AT TRAMSOM
575-051
575-122
575-133
6
DOOR JAMB AT TRAMSOM
575-051
7
DOOR JAMB
7
DOOR JAMB
575-104
200-795
069-139
575-122
8
DOOR WITH
TRANSOM
8
DOOR WITH
TRANSOM
9
BOTTOM RAIL
9
BOTTOM RAIL
200-795
7
575-064
575-006
575-065
575-004
575-007
575-003
OPTIONAL
RADIUS HEAD
575-004
575-003
575-006
575-037
575-037
OPTIONAL
HEAD & SILL
(FOR CONCEALED PERIMETER FASTENERS)
575-010
575-009
2-3/4"
(69.6)
EXPANSION MULLION
1/4" INFILL (NON-IMPACT)
GLAZING ADAPTOR
575-036
575-036
575-012
575-001
STRAP ANCHORS
kawneer.com
© Kawneer Company, Inc., 2010
MISCELLANEOUS FRAMING
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
IR 500
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
575-004
575-007
575-044
575-004
575-029
8
DECEMBER, 2011
EC 97911-37
HURRICANE RESISTANT PRODUCT
SCALE 3" = 1'-0"
575-063
575-013
© Kawneer Company, Inc., 2010
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
EC 97911-37
575-164
OPTIONAL HEAD
WITH STOP
575-118
kawneer.com
575-117
EXPANSION MULLION
575-036
575-036
575-112
575-101
STRAP ANCHORS
451-VG-030
575-102
575-104
451-VG-030
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2011
IR 501
MISCELLANEOUS FRAMING
HURRICANE RESISTANT PRODUCT
SCALE 3" = 1'-0"
575-163
575-065
575-103
OPTIONAL
RADIUS HEAD
575-116
2-3/4"
(69.6)
1" INFILL (NON-IMPACT)
GLAZING ADAPTOR
9
IR 500
10
DECEMBER, 2011
WINDLOAD CHARTS
EC 97911-37
HURRICANE RESISTANT PRODUCT
575-013 & 575-002
WITHOUT HORIZONTALS
A = 40 PSF (1920)
B = 50 PSF (2400)
C = 60 PSF (2880)
D = 70 PSF (3360)
E = 80 PSF (3840)
F = 90 PSF (4320)
16
15
WIDTH IN METERS
1.0
2.0
16
15
14
14
4.0
13
10
3.0
A
9
B
C
D
E
F 2.0
8
7
HEIGHT IN FEET
11
A
3.0
B
C
D
E
F
10
9
8
7
6
2.0
6
5
5
4
1.0
1
2
3
4
5
6
7
8
WIDTH IN FEET
575-013/575-002
4
IA = 8.422 in4 (350.55 x 104 mm4)
SA = 3.363 in3 (55.11 x 103 mm3)
3
1.0
1
2
3
4
5
6
7
8
WIDTH IN FEET
575-013 & 575-002 AND 575-110 STEEL
WITH HORIZONTALS
575-013 & 575-002 AND 575-110 STEEL
WITHOUT HORIZONTALS
WIDTH IN METERS
1.0
2.0
WIDTH IN METERS
1.0
2.0
16
16
15
15
14
4.0
13
12
A
10
B
C
D
E
F
9
8
7
3.0
HEIGHT IN FEET
11
HEIGHT IN METERS
12
10
9
8
575-013/575-002 AND 575-110 STEEL
6
5
IA = 8.422 in4 (350.55 x 104 mm4)
SA = 3.363 in3 (55.11 x 103 mm3)
5
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
8
B
C
D 3.0
E
F
7
2.0
4
A
11
6
3
4.0
13
IS = 1.729 in4 (71.97 x 104 mm4)
SS = 0.808 in3 (13.24 x 103 mm3)
HEIGHT IN METERS
14
HEIGHT IN FEET
11
HEIGHT IN METERS
12
HEIGHT IN METERS
HEIGHT IN FEET
12
3
4.0
13
2.0
4
3
1.0
1
2
3
4
5
6
7
8
WIDTH IN FEET
kawneer.com
© Kawneer Company, Inc., 2010
WIDTH IN METERS
1.0
2.0
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
575-013 & 575-002
WITH HORIZONTALS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are
for mullions WITH and WITHOUT HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable windload stress for
ALUMINUM 15,152 p.s.i. (104MPa). STEEL 20,000 p.s.i. (138MPa.) Charted curves, in all cases are for the limiting value.
A 4/3 increase in allowable stress has not been used to develop these curves.
For special situations not covered by these curves, contact your Kawneer representative for additional information.
IR 500
DECEMBER, 2011
EC 97911-37
11
WINDLOAD CHARTS
WIDTH IN METERS
1.0
2.0
16
16
15
14
14
4.0
11
10
A
B
C
D
E
F
9
8
7
3.0
12
HEIGHT IN FEET
12
11
A
10
B
C
D
E
F
9
8
7
2.0
6
3.0
2.0
6
5
5
575-009/575-010
1
2
3
4
5
6
WIDTH IN FEET
7
4
IA = 9.086 in4 (378.19 x 104 mm4)
SA = 3.627 in3 (59.44 x 103 mm3)
1.0
8
3
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
8
575-009 & 575-010 AND 575-110 STEEL
WITH HORIZONTALS
575-009 & 575-010 AND 575-110 STEEL
WITHOUT HORIZONTALS
WIDTH IN METERS
1.0
2.0
WIDTH IN METERS
1.0
2.0
16
16
15
15
14
14
4.0
A
10
B
C
D
E
F
9
8
7
3.0
HEIGHT IN FEET
11
12
HEIGHT IN METERS
12
10
9
8
6
575-009/575-010 AND 575-110 STEEL
6
5
IA = 9.086 in4 (378.19 x 104 mm4)
SA = 3.627 in3 (59.44 x 103 mm3)
5
3
1.0
1
kawneer.com
2
3
4
5
6
WIDTH IN FEET
7
8
A
B
C
D 3.0
E
F
11
7
2.0
4
4.0
13
IS = 1.729 in4 (71.97 x 104 mm4)
SS = 0.808 in3 (13.24 x 103 mm3)
2.0
4
3
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
8
HEIGHT IN METERS
4
HEIGHT IN FEET
4.0
13
HEIGHT IN METERS
13
13
© Kawneer Company, Inc., 2010
WIDTH IN METERS
1.0
2.0
15
3
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
575-009 & 575-010
WITHOUT HORIZONTALS
A = 40 PSF (1920)
B = 50 PSF (2400)
C = 60 PSF (2880)
D = 70 PSF (3360)
E = 80 PSF (3840)
F = 90 PSF (4320)
HEIGHT IN METERS
575-009 & 575-010
WITH HORIZONTALS
HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
HURRICANE RESISTANT PRODUCT
IR 500
12
DECEMBER, 2011
WINDLOAD CHARTS
EC 97911-37
16
15
15
14
14
4.0
11
10
3.0
A
9
B
C
D
E
F 2.0
8
7
6
12
HEIGHT IN FEET
12
A 3.0
10
B
C
D
E
F
9
8
2.0
6
5
575-050/575-035
1
2
3
4
5
6
WIDTH IN FEET
7
4
IA = 8.209 in4 (341.68 x 104 mm4)
SA = 3.049 in3 (49.96 x 103 mm3)
1.0
8
3
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
8
575-050 & 575-035 AND 575-111 STEEL
WITH HORIZONTALS
575-050 & 575-035 AND 575-111 STEEL
WITHOUT HORIZONTALS
WIDTH IN METERS
1.0
2.0
WIDTH IN METERS
1.0
2.0
16
16
15
15
14
14
4.0
A
11
B
C
3.0
D
E
F
10
9
8
7
9
8
575-050/575-035 AND 575-111 STEEL
6
5
IA = 8.209 in4 (341.68 x 104 mm4)
SA = 3.049 in3 (49.96 x 103 mm3)
5
3
1
2
3
4
5
6
WIDTH IN FEET
7
8
C
D
E 3.0
F
10
6
1.0
B
11
7
2.0
4
A
12
HEIGHT IN FEET
12
4.0
13
HEIGHT IN METERS
13
IS = 1. 729 in4 (71.97 x 104 mm4)
SS = 0. 808 in3 (13.24 x 103 mm3)
HEIGHT IN METERS
4
HEIGHT IN FEET
11
7
5
3
4.0
13
HEIGHT IN METERS
13
2.0
4
3
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
8
kawneer.com
© Kawneer Company, Inc., 2010
16
WIDTH IN METERS
1.0
2.0
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
WIDTH IN METERS
1.0
2.0
HEIGHT IN FEET
575-050 & 575-035
WITHOUT HORIZONTALS
A = 40 PSF (1920)
B = 50 PSF (2400)
C = 60 PSF (2880)
D = 70 PSF (3360)
E = 80 PSF (3840)
F = 90 PSF (4320)
HEIGHT IN METERS
575-050 & 575-035
WITH HORIZONTALS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
HURRICANE RESISTANT PRODUCT
IR 500
DECEMBER, 2011
EC 97911-37
13
WINDLOAD CHARTS
WIDTH IN METERS
1.0
2.0
16
16
15
14
14
4.0
11
10
3.0
A
9
B
C
D
E
F 2.0
8
7
6
12
HEIGHT IN FEET
12
4
3
4
5
6
WIDTH IN FEET
7
A
10
B
C
D
E
F
9
8
575-051/575-035
6
IA = 8.233 in4 (342.68 x 104 mm4)
SA = 3.177 in3 (52.06 x 103 mm3)
5
3.0
2.0
4
1.0
2
11
7
5
1
4.0
13
HEIGHT IN METERS
13
3
8
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
8
575-051 & 575-035 AND 575-111 STEEL
WITH HORIZONTALS
575-051 & 575-035 AND 575-111 STEEL
WITHOUT HORIZONTALS
WIDTH IN METERS
1.0
2.0
WIDTH IN METERS
1.0
2.0
16
15
15
14
14
4.0
11
B
C
10
D
E
F
9
3.0
8
7
10
9
8
6
575-051/575-035 AND 575-111 STEEL
6
5
IA = 8.233 in4 (342.68 x 104 mm4)
SA = 3.177 in3 (52.06 x 103 mm3)
5
3
1.0
1
kawneer.com
2
3
4
5
6
WIDTH IN FEET
7
8
B
C
D
E 3.0
F
11
7
2.0
4
A
12
HEIGHT IN FEET
A
HEIGHT IN METERS
HEIGHT IN FEET
12
4.0
13
IS = 2.946 in4 (122.62 x 104 mm4)
SS = 1.473 in3 (24.14 x 103 mm3)
2.0
4
3
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
8
HEIGHT IN METERS
16
13
© Kawneer Company, Inc., 2010
WIDTH IN METERS
1.0
2.0
15
3
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
575-051 & 575-035
WITHOUT HORIZONTALS
A = 40 PSF (1920)
B = 50 PSF (2400)
C = 60 PSF (2880)
D = 70 PSF (3360)
E = 80 PSF (3840)
F = 90 PSF (4320)
HEIGHT IN METERS
575-051 & 575-035
WITH HORIZONTALS
HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
HURRICANE RESISTANT PRODUCT
IR 501
14
DECEMBER, 2011
WINDLOAD CHARTS
EC 97911-37
16
15
15
14
14
4.0
11
10
A
9
B
C
D
E
F
8
7
3.0
12
HEIGHT IN FEET
12
9
8
2.0
5
575-116/575-102
1
2
3
4
5
6
WIDTH IN FEET
7
4
IA = 8.612 in4 (358.46 x 104 mm4)
SA = 3.472 in3 (56.90 x 103 mm3)
1.0
8
3
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
575-117 & 575-118
WITH HORIZONTALS
575-117 & 575-118
WITHOUT HORIZONTALS
WIDTH IN METERS
1.0
2.0
WIDTH IN METERS
1.0
2.0
16
16
15
15
14
14
4.0
11
10
A
9
3.0
B
C
D
E
F
8
7
12
HEIGHT IN FEET
12
4.0
13
HEIGHT IN METERS
13
8
11
A
10
B
C
D
E
F
9
8
7
2.0
6
3.0
HEIGHT IN METERS
4
2.0
6
5
5
575-117/575-118
4
3
A
3.0
B
C
D
E
F
10
6
5
HEIGHT IN FEET
11
7
2.0
6
3
4.0
13
HEIGHT IN METERS
13
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
8
IA = 9.285 in4 (386.47 x 104 mm4)
SA = 3.704 in3 (60.70 x 103 mm3)
4
3
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
8
kawneer.com
© Kawneer Company, Inc., 2010
16
WIDTH IN METERS
1.0
2.0
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
WIDTH IN METERS
1.0
2.0
HEIGHT IN FEET
575-116 & 575-102
WITHOUT HORIZONTALS
A = 40 PSF (1920)
B = 50 PSF (2400)
C = 60 PSF (2880)
D = 70 PSF (3360)
E = 80 PSF (3840)
F = 90 PSF (4320)
HEIGHT IN METERS
575-116 & 575-102
WITH HORIZONTALS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
HURRICANE RESISTANT PRODUCT
IR 501
DECEMBER, 2011
EC 97911-37
15
WINDLOAD CHARTS
WIDTH IN METERS
1.0
2.0
16
16
15
14
14
4.0
11
10
3.0
A
B
C
D
E
F 2.0
9
8
7
12
HEIGHT IN FEET
12
A 3.0
10
B
C
D
E
F
9
8
2.0
6
5
5
575-050/575-135
1
2
3
4
5
6
7
4
IA = 8.371 in4 (348.43 x 104 mm4)
SA = 3.226 in3 (52.86 x 103 mm3)
1.0
8
3
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
575-051 & 575-135
WITH HORIZONTALS
575-051 & 575-135
WITHOUT HORIZONTALS
WIDTH IN METERS
1.0
2.0
WIDTH IN METERS
1.0
2.0
16
16
15
15
14
14
4.0
11
10
3.0
A
9
B
C
D
E
F 2.0
8
7
12
HEIGHT IN FEET
12
4.0
13
HEIGHT IN METERS
13
8
11
A 3.0
B
C
D
E
F
10
9
8
7
6
2.0
6
5
5
575-051/575-135
4
1.0
1
kawneer.com
2
3
4
5
6
WIDTH IN FEET
7
8
IA = 8.393 in4 (349.34 x 104 mm4)
SA = 3.255 in3 (53.34 x 103 mm3)
4
3
1.0
1
2
3
4
5
6
WIDTH IN FEET
7
8
HEIGHT IN METERS
4
HEIGHT IN FEET
11
7
6
3
4.0
13
HEIGHT IN METERS
13
WIDTH IN FEET
© Kawneer Company, Inc., 2010
WIDTH IN METERS
1.0
2.0
15
3
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
575-050 & 575-135
WITHOUT HORIZONTALS
A = 40 PSF (1920)
B = 50 PSF (2400)
C = 60 PSF (2880)
D = 70 PSF (3360)
E = 80 PSF (3840)
F = 90 PSF (4320)
HEIGHT IN METERS
575-050 & 575-135
WITH HORIZONTALS
HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
HURRICANE RESISTANT PRODUCT
IR 500/501
16
FEBRUARY, 2012
DEADLOAD CHARTS
EC 97911-37
HURRICANE RESISTANT PRODUCT
Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate horizontal member.
The accompanying charts are calculated for 9/16" or 5/8" thick impact resistant glass or 1-5/16" thick insulated impact resistant glass supported on
two setting blocks placed at the loading points shown.
575-011
575-115
WIDTH IN METERS
WIDTH IN METERS
1.0
2.0
16
16
15
15
14
14
12
11
11
9
8
2.0
10
8
7
6
6
5
5
4
C
3
B
2
A
1
2
3
4
5
6
WIDTH IN FEET
7
8
3.0
9
2.0
4
1.0
C 1.0
3
B
2
575-011
(IR 500)
I = 1.043 in4 (43.41 x 104 mm4)
S = 0.697 in3 (11.42 x 103 mm3)
1
A
1
2
3
4
5
6
WIDTH IN FEET
7
8
575-115
(IR 501)
I = 0.929 in4 (38.67 x 104 mm4)
S = 0.620 in3 (10.16 x 103 mm3)
kawneer.com
© Kawneer Company, Inc., 2012
7
HEIGHT IN FEET
3.0
HEIGHT IN METERS
HEIGHT IN FEET
12
10
4.0
13
HEIGHT IN METERS
4.0
13
1
2.0
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1.0
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
A = (1/4 POINT LOADING)
B = (1/6 POINT LOADING)
C = (1/8 POINT LOADING)
IR 500/501
FEBRUARY, 2012
EC 97911-37
DEADLOAD CHARTS
HURRICANE RESISTANT PRODUCT
DEADLOADS ON ENTRANCE TRANSOM BARS
Height limitations for transom glass over a doorway are based on a 1/16" (1.6) maximum allowable deflection at the center of a transom bar.
The accompanying chart is calculated for 9/16" or 5/8" thick impact resistant glass or 1-5/16" thick insulated impact resistant glass supported on
two setting blocks placed at the loading points shown.
15
14
14
4.0
13
12
11
11
9
8
7
2.0
HEIGHT IN FEET
3.0
HEIGHT IN METERS
12
10
10
3.0
9
8
7
2.0
6
6
5
5
4
4
C
3
B
2
A
1.0
3
1
2
3
4
5
6
7
WIDTH IN FEET
8
C
B
A
575-022
(IR 500)
I = 1.248 in4 (51.95 x 104 mm4)
S = 0.777 in3 (12.73 x 103 mm3)
575-023 HORIZONTAL
WIDTH IN METERS
1.0
2.0
16
15
14
4.0
13
11
10
3.0
9
8
7
C2.0
HEIGHT IN METERS
12
HEIGHT IN FEET
4.0
13
6
B
5
4
A
3
1.0
2
1
1
2
3
4
5
6
WIDTH IN FEET
kawneer.com
7
8
575-023
(IR 500)
I = 1.764 in4 (73.42 x 104 mm4)
S = 1.081 in3 (17.71 x 103 mm3)
1
1
2
3
4
5
6
WIDTH IN FEET
7
8
HEIGHT IN METERS
16
15
1
© Kawneer Company, Inc., 2012
WIDTH IN METERS
1.0
2.0
16
2
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
575-122 HORIZONTAL
A = (1/4 POINT LOADING)
B = (1/6 POINT LOADING)
C = (1/8 POINT LOADING)
WIDTH IN METERS
1.0
2.0
HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
575-022 HORIZONTAL
1.0
575-122
(IR 501)
I = 1.177 in4 (48.99 x 104 mm4)
S = 0.722 in3 (11.83 x 103 mm3)
17
IR 500/501
18
FEBRUARY, 2012
EC 97911-37
DEADLOAD CHARTS
HURRICANE RESISTANT PRODUCT
575-120
WIDTH IN METERS
2.0
1.0
16
15
15
14
14
4.0
12
12
11
11
3.0
9
8
7
2.0
HEIGHT IN FEET
10
10
8
7
6
5
5
4
1.0
2
1
2
3
4
5
6
WIDTH IN FEET
7
8
575-020
(IR 500)
I = 1.148 in4 (47.78 x 104 mm4)
S = 0.751 in3 (12.31 x 103 mm3)
2.0
4
C
3
B
2
A
1
1
2
3
4
5
6
WIDTH IN FEET
7
8
1.0
575-120
(IR 501)
I = 1.080 in4 (44.95 x 104 mm4)
S = 0.683 in3 (11.19 x 103 mm3)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1
C
B
A
3.0
9
6
3
4.0
13
HEIGHT IN METERS
HEIGHT IN FEET
13
2.0
HEIGHT IN METERS
1.0
16
575-021
WIDTH IN METERS
1.0
2.0
16
15
14
4.0
13
HEIGHT IN FEET
11
10
3.0
9
8
7
2.0
6
HEIGHT IN METERS
12
C
5
B
4
A
3
1.0
2
1
1
2
3
4
5
6
WIDTH IN FEET
7
8
575-021
(IR 500)
I = 1.621 in4 (67.47 x 104 mm4)
S = 1.234 in3 (20.22 x 103 mm3)
kawneer.com
© Kawneer Company, Inc., 2012
575-020
WIDTH IN METERS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
A = (1/4 POINT LOADING)
B = (1/6 POINT LOADING)
C = (1/8 POINT LOADING)
IR 501
DECEMBER, 2011
EC 97911-37
THERMAL CHARTS
HURRICANE RESISTANT PRODUCT
Project Specific U-factor Example Calculation
15'-10"
2'-0"
9'-7 1/2"
7'-0"
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
5'-0"
Example Glass U-factor= 0.42 Btu/hr·ft2·oF
Total Daylight Opening = 3(5' x 7') + 3(5' x 2') = 135ft2
Total Projected Area
= (Total Daylight Opening + Total Area of Framing System)
= 15'-10" x 9'-7 1/2" = 152.39ft2
Percent of Glass
= (Total Daylight Opening ÷ Total Projected Area)
= (135 ÷ 152.39)100 = 88%
System U-factor vs Percent of Glass Area
0.80
0.70
0.65
X
E
COG
U-factor
0.55
M
0.48
0.46
0.44
0.42
0.40
0.38
0.36
0.34
0.32
0.30
0.28
0.26
0.24
0.22
0.20
0.50
P
0.45
L
0.40
E
© Kawneer Company, Inc., 2010
0.60
A
0.35
0.30
0.25
88%
70
75
80
90
85
0.20
95
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.75
Percent of Glass
Based on 88% glass and center of glass (COG) U-factor of 0.42
System U-factor is equal to 0.51 Btu/hr x ft2 x oF
kawneer.com
0.51
19
System U-Factor for Vision Glass
COG
U-factor
0.48 (2.73)
0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.40 (2.27)
0.38 (2.16)
0.36 (2.05)
0.34 (1.93)
0.32 (1.82)
0.30 (1.71)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
Vision Area / Total Area (%)
kawneer.com
© Kawneer Company, Inc., 2010
THERMAL CHARTS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
IR 501
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System U-Factor (Btu/h·ft2·°F)
20
DECEMBER, 2011
EC 97911-37
HURRICANE RESISTANT PRODUCT
Note:
Values in parentheses are metric.
COG=Center of Glass.
Charts are generated per AAMA 507.
System VT
© Kawneer Company, Inc., 2010
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2011
kawneer.com
IR 501
EC 97911-37
COG
SHGC
Vision Ares / Total Area (%)
Charts are generated per AAMA 507.
21
THERMAL CHARTS
HURRICANE RESISTANT PRODUCT
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
Vision Area / Total Area (%)
Charts are generated per AAMA 507.
COG
VT
System Visible Transmittance (VT) vs Percent of Vision Area
IR 501
DECEMBER, 2011
EC 97911-37
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
HURRICANE RESISTANT PRODUCT
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Overall U-Factor 4
0.48
0.65
0.46
0.63
0.44
0.62
0.42
0.60
0.40
0.59
0.38
0.57
0.36
0.56
0.34
0.54
0.32
0.52
0.30
0.51
0.28
0.49
0.26
0.48
0.24
0.46
0.22
0.45
0.20
0.43
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.66
0.75
0.65
0.70
0.62
0.70
0.60
0.65
0.58
0.65
0.56
0.60
0.53
0.60
0.52
0.55
0.49
0.55
0.47
0.50
0.45
0.50
0.43
0.45
0.40
0.45
0.39
0.40
0.36
0.40
0.34
0.35
0.32
0.35
0.30
0.30
0.27
0.30
0.26
0.25
0.23
0.25
0.22
0.20
0.19
0.20
0.17
0.15
0.15
0.15
0.13
0.10
0.10
0.10
0.09
0.05
0.06
0.05
0.04
NOTE: For glass values that are not listed, linear interpolation is permitted.
1. U-Factors are determined in accordance with NFRC 100.
2. SHGC and VT values are determined in accordance with NFRC 200.
3. Glass properties are based on center of glass values and are obtained from your glass supplier.
4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of
2000mm wide by 2000mm high (78-3/4" by 78-3/4").
kawneer.com
© Kawneer Company, Inc., 2010
SHGC Matrix 2
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
22