Series 602 10A, 250Vac Optically Isolated AC Solid-State Relay Part* DESC Drawing Relay Description Number Number 602-1W 602-1Y 10 A, 250 VAC AC Solid State Relay 86031-001 10 A, 250 VAC AC Solid State Relay * The Y suffix denotes parameters tested to MIL-PRF-28750 test methods. The W suffix denotes parameters tested to Teledyne specifications. ELECTRICAL SPECIFICATIONS FEATURES • Available to DESC drawing 86031-001 (-55°C TO +95°C UNLESS OTHERWISE SPECIFIED) • Optical isolation INPUT (CONTROL) CHARACTERISTICS Min Typ • Low minimum output current Max Units • Zero voltage turn-on Input Current (See Figure 1) VIN = 5 Vdc VIN=32 Vdc 15 mA dc 16 mA dc Turn-Off Voltage (Guaranteed Off) Turn-On Voltage (Guaranteed On) 1.0 3.8 Vdc Vdc Reverse Voltage Protection Input Voltage Range 3.8 -32 Vdc 32 Vdc OUTPUT (LOAD) SPECIFICATIONS Min Typ Max Units Output Current Range (See Figure 3) 0.1 10 Amps Output voltage Rating 25 250 Vac Frequency Range 45 440 Hz Output Voltage Drop @ 10 Amp (See Figure 2) 1.5 Vrms Off-State Leakage Current (250 Vac, 400 Hz) 8.0 mA Turn-On Time 1/2 Cycle Turn-Off Time 1 Cycle Transient Voltage (20 msec) +460 V pk Overload Current (16.6 msec) 100 Amps Zero Voltage Turn-On Point +15 dv/dt @ 25oC (See Note 4) 200 Load Power Factor 0.2 Insulation Resistance @ 500 Vdc 109 Input to Output Capacitance 602 82 • Extremely low EMI • Zero current turn-off • Logic compatible input • Available to Y screening levels of MIL-PRF-28750 DESCRIPTION The 602-1 is an AC output solidstate relay designed for power switching. The relay incorporates a hermetically sealed, optically coupled solid state relay as a driver. This driver provides zero voltage turn-on as well as a logic compatible control circuit. The relay output is rated for 10A at 250Vac and switches the load with a hermetically sealed triac. A builtin snubber circuit provides reliable switching of both resistive and reactive loads with power factors as low as 0.2. The internal components are potted with a thermally conductive epoxy, which provides an environmental seal for severe environmental conditions encountered in military and aerospace applications. The 602-1 is available in W and Y screening levels. The 602-1Y is available to DESC drawing 86031-001. Vpk V/µs WIRING DIAGRAM Ohm 15 pF SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2002 TELEDYNE RELAYS 602\072002\Q1 Series 602 OUTPUT (LOAD) SPECIFICATIONS Min Dielectric Withstanding Voltage Typ Max 1500 Units Vac o Junction Temperature (TJ Max) 150 C Thermal Resistance Junction to Ambient (θJA) 15.5 o Thermal Resistance Junction to Case (θJC) 2.5 o C/W C/W ENVIRONMENTAL SPECIFICATIONS Min Ambient Temperature Operating Storage Typ -55 -55 Max +95 +110 Units o o INPUT CURRENT VS INPUT VOLTAGE FIGURE 1 C C Shock for 6 ms 100 g Vibration, 78 to 2000 Hz 30 g 100 g (0.1 Double Amplitude 10 to 78 Hz) Acceleration MECHANICAL SPECIFICATIONS LOAD CURRENT VS TYPICAL OUTPUT VOLTAGE DROP FIGURE 2 THERMAL DERATING CURVES FIGURE 3 DIMENSIONS ARE SHOWN IN INCHES (MILLIMETERS) • Case Material: Self extinguishing plastic • Epoxy Filled • Case Color: Black • Base Plate Material: Aluminum • Circuit diagram shown on part is terminal view. © 2002 TELEDYNE RELAYS NOTES: 1. UNLESS OTHERWISE SPECIFIED, TOLERANCES: .XXX = ± .005 (0.13mm); .XX = ± .01 (0.25mm). 2. Weight: max. 3 oz. 3. BUILT IN SNUBBER (R = 100 W C = 0.01mF). 4. Output may lose blocking capabilities during and after surge until TJ falls below maximum. 5. 100mS pulse @ 1 Hz reptitive rate at 25°C, maximum 10 cycles. (800) 284-7007 • www.teledynerelays.com 602 83 602\072002\Q1