Automotive ICs
MLX80001
4-Channel LIN Transceiver
Intelligent Drivers
and Actuators
Features
Hall ICs
The MLX80001 is a 4 channel physical layer device for applications
using the Local Interconnect Network (LIN) protocol. The device is
designed in accordance to the physical layer definition of the LIN
Protocol Specification Package 2.0 and the SAE J2602 standard .The
IC furthermore can be used in ISO9141 systems.
Because of the very low current consumption of the MLX80001 in the
recessive state it’s suitable for ECU applications with hard standby
current requirements. An advanced sleep mode capability allows a
shutdown of a complete master node.
4 Channel enhanced Master Transceiver
• Slew rate selection for 10.4kbps (J2602) and 20kbps (LIN 2.x) for optimized radiated emission behavior
BUS ICs
• Compatible to LIN 2.x and J2602
• High EMI immunity
• Disable of slew rate control for fast programming or test modes
• High impedance LIN in case of loss of ground , loss of battery and under voltage condition
• LIN terminals proof against short-circuits and transients in the automotive environment
Silicon MEMS
Protections
• LIN short to ground protection
• ±5kV ESD protection pin LIN, ±4kV ESD protection on any other high voltage pin
Power consumtion
CMOS Imaging
• Thermal overload protection
• Only 20µA typical power consumption in sleep mode
• Remote wake up via LIN traffic
Bus ICs
Other Features
• Integrated 1k master termination resistors and decoupling diodes
• 5V and 3.3V compatible digital inputs without any external component required
• Automotive Temperature Range of –40°C to 125°C
• Small MLF 5x5 20pin package
• Available as lead-free and ROHS compliant
IR Temperature
• Control output for voltage regulator
Applications
VS
• LIN Master Nodes with multiple LIN Bus connections
• Body Control Module
INH
Vs
20
Hall ICs
WakeFilter
TxD4
MODE0
MODE1
GNDD
TxD1
VS
Rec-Filter
RxD1
Receiver
1K
LIN1
TSHD
MR
VCC
Driver
control
14
MLX80001
13
3
MLPQ5x 5
4
channel2
LIN2
channel3
LIN3
channel4
LIN4
TxD2
TxD3
RxD4
TxD4
12
11
5
channel1
RxD2
RxD3
BUS Ics
15
2
6
Filter
TxD1
1
RxD1
LIN1
GNDL
Intelligent Drivers
and Actuators
200K
16
Charge
pump
RCO
17
Sleep timer
INH
RxD3
TxD3
GNDA
TxD2
10
RxDx time out
Wake-up
Control
18
MODE1
Pinout - MLPQ 5x5 20
UV/POR
9
Mode
Control
Vs
monitor/
POR
LIN2
RxD2
MODE0
Temp.
Protection
8
TSHD
RxD4
LIN4
GNDL
LIN3
Vs
VBG
Bandgap
7
Aux.
Supply
19
Automotive ICs
Block Diagram
Application Schematic
1N4001
VBAT_ECU
2.2uF
100nF
Silicon MEMS
Voltage
regulator
VBAT
Master
ECU
INH
+5V
100nF
CMOS Imaging
47nF
VDD
MCU
INH
VSUP
MLX80001
10
Rx/Tx LIN1
RxD1
TxD1
LINBUS1
LIN1
180pF
ESD
protection
Rx/Tx LIN2
Rx/Tx LIN3
Bus ICs
CAN
SWCAN
TH8056
or
HSCAN
RxD2
TxD2
(E.g. PESD1CAN)
LIN2
180pF
RxD3
TxD3
LINBUS2
10
10
LINBUS3
LIN3
INH
Control
CAN Rx/Tx LIN4
Rx/Tx
CAN
Control
LIN
GND
180pF
RxD4
TxD4
ESD
protection
(E.g. PESD1CAN)
MODE0
MODE1 GND
LIN4
180pF
10
LINBUS4
Devices sold by Melexis are covered by the warranty and patent indemnification provisions appearing in its Term of Sale. Melexis makes no warranty, express, statutory, implied, or by
description regarding the information set forth herein or regarding the freedom of the described devices from patent infringement. Melexis reserves the right to change specifications and
prices at any time and without notice. Therefore, prior to designing this product into a system, it is necessary to check with Melexis for current information. This product is intended for use
in normal commercial applications. Applications requiring extended temperature range, unusual environmental requirements, or high reliability applications, such as military, medical lifesupport or life-sustaining equipment are specifically not recommended without additional processing by Melexis for each application. The information furnished by Melexis is believed to be
correct and accurate. However, Melexis shall not be liable to recipient or any third party for any damages, including but not limited to personal injury, property damage, loss of profits, loss
of use, interrupt of business or indirect, special incidental or consequential damages, of any kind, in connection with or arising out of the furnishing, performance or use of the technical
data herein. No obligation or liability to recipient or any third party shall arise or flow out of Melexis’ rendering of technical or other services.
© 2006 Melexis NV. All rights reserved.
Email Europe and rest of the world:
[email protected]
Email USA :
[email protected]
For additional information go to our website at:
Email Asia:
[email protected]
Jan 2007
IR Temperature
Disclaimer: