Datasheet

Series CCT-39S
COAX SWITCHES
Multi-Throw DC-10 GHz, SP9T & SP10T
Latching Coaxial Switch, Internal 50Ω Termination
PART NUMBER
DESCRIPTION
CCT-39S
Commercial Latching Multi-throw, DC-10GHz
The CCT-39S is a broadband, multi-throw, electromechanical coaxial switch designed to switch a
microwave signal from a common input to any of 9 or 10 outputs. The characteristic impedance is 50
Ohms. Each position has an individual actuator mechanism allowing random position selection. This also
minimizes switching time.
The CCT-39S comes with a latching actuator. The latching switch remains in the last position selected
when the switch is de-energized. STD dual command requires a reset pulse before a new selected
position. A separate reset circuit allows all positions to be set to an open position. User must provide both
reset (clear) and set (select new position) commands.
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS
ELECTRICAL CHARACTERISTICS
Operating Temperature
Commercial Model, CCT-39S
Form Factor
Multi-Throw,
break before make
–40°C to 65°C
Vibration (MIL-STD-202 Method 214,
Condition D, non-operating)
10 g’s RMS
Shock (MIL-STD-202 Method 213,
Condition D, non-operating)
500 g’s
Standard Actuator Life
Actuator Life w/ Additional Features
3,000,000 cycles
1,000,000 cycles
Connector Type
SMA
Humidity (Moisture Seal)
Available
Weight
9 oz. (255.2g) (max.)
Frequency Range
CCT-39S
DC–10 GHz
Characteristic Impedance
50 Ohms
Operate Time
20 ms (max.)
Actuation Voltage Available
12
15
24
28 V
Actuation Current
110 105
90
105 mA
Reset Current (# of Positions)
(9)
990 945 810 945 mA
(10)
1100 1050 900 1050 mA
PERFORMANCE CHARACTERISTICS
Frequency
DC–2.3 GHz
2.3-3.0 GHz
3.0-6.0 GHz
6.0-8.0 GHz
8.0-10.0 GHz
0.2
0.25
0.30
0.40
0.6
Insertion Loss, dB,
max.
Isolation, dB, min.
VSWR , max.
80
70
65
60
60
1.15:1
1.20:1
1.30:1
1.40:1
1.60:1
PART NUMBERING SYSTEM
CCT-39
S
6
0
C
-
T **
Series
Options
Connectors
Actuator Type
Actuator Voltage
Number of Positions
CONNECTOR
ACTUATOR VOLTAGE
NUMBER OF POSITIONS
ACTUATOR TYPE
OPTIONS
S: SMA FEMALE
6: 28 VDC LATCHING
9: SP9T
0: NO INDICATOR CONTACTS
T: TTL DRIVERS WITH DIODES
7: 15 VDC LATCHING
0: SP10T
C: INDICATOR CONTACTS
D: COIL TRANSIENT SUPPRESSION DIODES
8: 12 VDC LATCHING
R: POSITIVE
+ COMMON
9: 24 VDC LATCHING
TD: DECODERS AND TTL DRIVERS WITH
DIODES
**SEE PART NUMBER ON PAGE
10
M: MOISTURE SEAL
S: D-SUB CONNECTOR*
For additional options, please contact factory.
* D-Sub Connector may be 15 or 26 pin depending on number of throws. (See
Connector Pinout page)
**1 D-Sub Connectors is standard configuration on all models unless
otherwise specified
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCT-39S/Page 1
CCT-39S\072013\Q3
Series CCT-39S
Multi-Throw DC-10 GHz, SP9T & SP10T
Latching Coaxial Switch, Internal 50Ω Termination
COAX SWITCHES
SCHEMATICS AND MECHANICAL OUTLINE
“-S OPTION” 15-PIN D-SUB OR 26-PIN D-MICRO CONNECTOR (EXAMPLE:
CCT-39 Page 2
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
CCT-39S690-S)
© 2013 TELEDYNE COAX SWITCHES
CCT-39S\072013\Q3
Series CCT-39S
COAX SWITCHES
Multi-Throw DC-10 GHz, SP9T & SP10T
Latching Coaxial Switch, Internal 50Ω Termination
CONNECTOR PINOUT FOR LATCHING SP9T MULTI-THROW SWITCHES
EXAMPLE
CCT-39S690-S
INDICATOR
CCT-39S69C-S
CCT-39S690-TS
TTL
CCT39S69C-TS
CCT-39S690-TDS
YES
YES
YES
YES
DECODERS & TTL
CCT-39S69C-TDS
YES
YES
YES
PIN NO.
15-PIN
26-PIN
15-PIN
26-PIN
15-PIN
26-PIN
1
PORT 1
PORT 1
TTL 1
TTL 1
LOGIC 1
LOGIC 1
2
PORT 2
PORT 2
TTL 2
TTL 2
LOGIC 2
LOGIC 2
3
PORT 3
PORT 3
TTL 3
TTL 3
LOGIC 3
LOGIC 3
4
PORT 4
PORT 4
TTL 4
TTL 4
LOGIC 4
LOGIC 4
5
PORT 5
PORT 5
TTL 5
TTL 5
6
PORT 6
PORT 6
TTL 6
TTL 6
7
PORT 7
PORT 7
TTL 7
TTL 7
8
PORT 8
PORT 8
TTL 8
TTL 8
9
PORT 9
PORT 9
TTL 9
TTL 9
VSW
VSW
14
Reset
Reset
Reset
Reset
15
COMMMON
COMMMON
COMMMON
15-PIN D-SUB CONNECTOR
26-PIN D-SUB CONNECTOR
10
11
12
13
COMMMON
VSW
VSW
COMMMON
COMMMON
16
D Indicator (COM)
D Indicator
(COM)
D Indicator (COM)
17
E Indicator
E Indicator
E Indicator
18
F Indicator
F Indicator
F Indicator
19
G Indicator
G Indicator
G Indicator
20
H Indicator
H Indicator
H Indicator
21
K Indicator
K Indicator
K Indicator
22
L Indicator
L Indicator
L Indicator
23
M Indicator
M Indicator
M Indicator
24
N Indicator
N Indicator
N Indicator
25
P Indicator
P Indicator
P Indicator
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCT-39S/Page 3
CCT-39S\072013\Q3
Series CCT-39S
COAX SWITCHES
Multi-Throw DC-10 GHz, SP9T & SP10T
Latching Coaxial Switch, Internal 50Ω Termination
SP9T TRUTH TABLE Latching
CCT-39SX9C-T
Logic Input
RF Path
Indicator Switches
1
2
3
4
5
6
7
8
9
R
J1
J2
J3
J4
J5
J6
J7
J8
J9
Reset
E
F
G
H
K
L
M
N
O
1
0
0
0
0
0
0
0
0
0
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
C
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
Off
On
Off
Off
Off
Off
Off
Off
Off
Off
0
C
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
Off
Off
On
Off
Off
Off
Off
Off
Off
Off
0
0
C
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
Off
Off
Off
On
Off
Off
Off
Off
Off
Off
0
0
0
C
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
Off
Off
Off
Off
On
Off
Off
Off
Off
Off
0
0
0
0
C
0
0
0
0
0
0
0
0
0
1
0
0
0
0
Off
Off
Off
Off
Off
On
Off
Off
Off
Off
0
0
0
0
0
C
0
0
0
0
0
0
0
0
0
1
0
0
0
Off
Off
Off
Off
Off
Off
On
Off
Off
Off
0
0
0
0
0
0
C
0
0
0
0
0
0
0
0
0
1
0
0
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
0
0
0
0
0
0
0
C
0
0
0
0
0
0
0
0
0
1
0
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
0
0
0
0
0
0
0
0
C
TRUTH TABLE Latching
CCT-39SX9C-TD
Logic Input
RF Path
Indicator Switches
1
2
3
4
J1
J2
J3
J4
J5
J6
J7
J8
J9
Reset
E
F
G
H
K
L
M
N
O
0
0
0
0
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
C
0
0
0
0
0
0
0
0
1
0
0
0
Off
On
Off
Off
Off
Off
Off
Off
Off
Off
0
C
0
0
0
0
0
0
0
0
1
0
0
Off
Off
On
Off
Off
Off
Off
Off
Off
Off
0
0
C
0
0
0
0
0
0
1
1
0
0
Off
Off
Off
On
Off
Off
Off
Off
Off
Off
0
0
0
C
0
0
0
0
0
0
0
1
0
Off
Off
Off
Off
On
Off
Off
Off
Off
Off
0
0
0
0
C
0
0
0
0
1
0
1
0
Off
Off
Off
Off
Off
On
Off
Off
Off
Off
0
0
0
0
0
C
0
0
0
0
1
1
0
Off
Off
Off
Off
Off
Off
On
Off
Off
Off
0
0
0
0
0
0
C
0
0
1
1
1
0
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
0
0
0
0
0
0
0
C
0
0
0
0
1
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
0
0
0
0
0
0
0
0
C
1
0
0
1
Off
Off
Off
Off
Off
Off
Off
Off
Off
Reset
1
1
1
1
CCT-39 Page 4
COIL OFF
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCT-39S\072013\Q3
Series CCT-39S
COAX SWITCHES
Multi-Throw DC-10 GHz, SP9T & SP10T
Latching Coaxial Switch, Internal 50Ω Termination
CONNECTOR PINOUT FOR LATCHING SP10T MULTI-THROW SWITCHES
EXAMPLE
CCT-39S600-S
INDICATOR
CCT-39S60C-S
CCT-39S600-TS
TTL
CCT-39S60C-TS
CCT-39S600-TDS
YES
YES
YES
YES
DECODERS & TTL
CCT-39S60C-TDS
YES
YES
YES
PIN NO.
15-PIN
26-PIN
15-PIN
26-PIN
15-PIN
26-PIN
1
PORT 1
PORT 1
TTL 1
TTL 1
LOGIC 1
LOGIC 1
2
PORT 2
PORT 2
TTL 2
TTL 2
LOGIC 2
LOGIC 2
3
PORT 3
PORT 3
TTL 3
TTL 3
LOGIC 3
LOGIC 3
4
PORT 4
PORT 4
TTL 4
TTL 4
LOGIC 4
LOGIC 4
5
PORT 5
PORT 5
TTL 5
TTL 5
6
PORT 6
PORT 6
TTL 6
TTL 6
7
PORT 7
PORT 7
TTL 7
TTL 7
8
PORT 8
PORT 8
TTL 8
TTL 8
9
PORT 9
PORT 9
TTL 9
TTL 9
10
PORT 10
PORT 10
TTL 10
TTL 10
VSW
VSW
14
Reset
Reset
Reset
Reset
15
COMMMON
COMMMON
COMMMON
15-PIN D-SUB CONNECTOR
26-PIN D-SUB CONNECTOR
11
12
13
COMMMON
VSW
COMMMON
VSW
COMMMON
16
D Indicator (COM)
D Indicator (COM)
D Indicator (COM)
17
E Indicator
E Indicator
E Indicator
18
F Indicator
F Indicator
F Indicator
19
G Indicator
G Indicator
G Indicator
20
H Indicator
H Indicator
H Indicator
21
K Indicator
K Indicator
K Indicator
22
L Indicator
L Indicator
L Indicator
23
M Indicator
M Indicator
M Indicator
24
N Indicator
N Indicator
N Indicator
25
P Indicator
P Indicator
P Indicator
26
T Indicator
T Indicator
T Indicator
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCT-39S/Page 5
CCT-39S\072013\Q3
Series CCT-39S
COAX SWITCHES
Multi-Throw DC-10 GHz, SP9T & SP10T
Latching Coaxial Switch, Internal 50Ω Termination
SP10T TRUTH TABLE Latching
CCT-39SX0C-T
Logic Input
RF Path
Indicator Switches
1
2
3
4
5
6
7
8
9
10
R
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
Reset
E
F
G
H
K
L
M
N
O
P
1
0
0
0
0
0
0
0
0
0
0
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
C
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
Off
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
0
C
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
Off
Off
On
Off
Off
Off
Off
Off
Off
Off
Off
0
0
C
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
Off
Off
Off
On
Off
Off
Off
Off
Off
Off
Off
0
0
0
C
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
Off
Off
Off
Off
On
Off
Off
Off
Off
Off
Off
0
0
0
0
C
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
Off
Off
Off
Off
Off
On
Off
Off
Off
Off
Off
0
0
0
0
0
C
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
Off
Off
Off
Off
Off
Off
On
Off
Off
Off
Off
0
0
0
0
0
0
C
0
0
0
0
0
0
0
0
0
0
1
0
0
0
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
Off
0
0
0
0
0
0
0
C
0
0
0
0
0
0
0
0
0
0
1
0
0
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
0
0
0
0
0
0
0
0
C
0
0
0
0
0
0
0
0
0
0
1
0
Off
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
0
0
0
0
0
0
0
0
0
C
TRUTH TABLE Latching
CCT-39SX0C-TD
Logic Input
RF Path
Indicator Switches
1
2
3
4
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
Reset
E
F
G
H
K
L
M
N
O
P
0
0
0
0
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
C
0
0
0
0
0
0
0
0
0
1
0
0
0
Off
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
0
C
0
0
0
0
0
0
0
0
0
1
0
0
Off
Off
On
Off
Off
Off
Off
Off
Off
Off
Off
0
0
C
0
0
0
0
0
0
0
1
1
0
0
Off
Off
Off
On
Off
Off
Off
Off
Off
Off
Off
0
0
0
C
0
0
0
0
0
0
0
0
1
0
Off
Off
Off
Off
On
Off
Off
Off
Off
Off
Off
0
0
0
0
C
0
0
0
0
0
1
0
1
0
Off
Off
Off
Off
Off
On
Off
Off
Off
Off
Off
0
0
0
0
0
C
0
0
0
0
0
1
1
0
Off
Off
Off
Off
Off
Off
On
Off
Off
Off
Off
0
0
0
0
0
0
C
0
0
0
0
1
1
1
0
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
Off
0
0
0
0
0
0
0
C
0
0
0
0
1
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
0
0
0
0
0
0
0
0
C
0
1
0
0
1
Off
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
0
0
0
0
0
0
0
0
0
C
0
1
0
1
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Reset
0
0
0
0
0
0
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
0
0
0
CCT-39 Page 6
COIL OFF
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCT-39S\072013\Q3
Series CCT-39S
COAX SWITCHES
Multi-Throw DC-10 GHz, SP9T & SP10T
Latching Coaxial Switch, Internal 50Ω Termination
TYPICAL RF PERFORMANCE CURVES
Insertion Loss (DC-10GHz)
0.0
-0.1
-0.2
Isolaion (dB)
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1.0
0
1
2
3
4
5
6
7
8
9
10
7
8
9
10
Frequency (GHz)
VSWR (DC-10GHz)
2.0
1.9
1.8
VSWR (dB)
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0
1
2
3
4
5
6
Frequency (GHz)
Isolation (DC-10Ghz)
0
-20
Isolation (dB)
-40
-60
-80
-100
-120
-140
0
1
2
3
4
5
6
7
8
9
10
Frequency (GHz)
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCT-39S/Page 7
CCT-39S\072013\Q3
Series CCT-39S
COAX SWITCHES
Multi-Throw DC-10 GHz, SP9T & SP10T
Latching Coaxial Switch, Internal 50Ω Termination
TYPICAL POWER PERFORMANCE CURVE
Power Handling vs. Frequency
3000
2000
1000
800
600
Power (W)
400
STA
ND
300
ARD
200
SM
AS
WIT
CH
ES
100
80
60
40
30
20
10
.1
.2
.3 .4 .6 .8 1
2
4
6 8 10
12
Frequency GHz
Estimates based on the following reference conditions:
• Ambient temperature of 40°C or less
• Sea level operation
• Load VSWR of 1.20:1 maximum
• No high-power (hot) switching
Please contact Teledyne Coax Switches for derating factors when applications do not meet the foregoing reference conditions.
CCT-39 Page 8
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCT-39S\072013\Q3
Series CCT-39S
COAX SWITCHES
Multi-Throw DC-10 GHz, SP9T & SP10T
Latching Coaxial Switch, Internal 50Ω Termination
GLOSSARY
Actuator
An actuator is the electromechanical mechanism that transfers the
RF contacts from one position to another upon DC command.
Arc Suppression Diode
A diode is connected in parallel with the coil. This diode limits the
“reverse EMF spike” generated when the coil de-energizes to 0.7
volts. The diode cathode is connected to the positive side of the
coil and the anode is connected to the negative side.
Actuator Current vs Temperature
The resistance of the actuator coil varies as a function of
temperature. There is an inverse relationship between the
operating temperature of the switch and the actuator drive current.
For switches operating at 28 VDC, the approximate actuator drive
current at temperature, T, can be calculated using the equation:
IT =
Date Code
All switches are marked with either a unique serial number or a
date code. Date codes are in accordance with MIL-STD-1285
Paragraph 5.2.5 and consist of four digits. The first two digits
define the year and the last two digits define the week of the year
(YYWW). Thus, 1032 identifies switches that passed through final
inspection during the 32nd week of 2010.
IA
[1 + .00385 (T-20)]
Where:
IT = Actuator current at temperature, T
IA = Room temperature actuator current –
see data sheet
T = Temperature of interest in °C
Indicator
Indicators tell the system which position the switch is in. Other
names for indicators are telemetry contacts or tellback circuit.
Indicators are usually a set of internally mounted DC contacts
linked to the actuator. They can be wired to digital input lines,
status lights, or interlocks. Unless otherwise specified, the
maximum indicator contact rating is 30 Vdc, 50 mA, or 1.5 Watts
into a resistive load.
Magnetic Sensitivity
An electro-mechanical switch can be sensitive to ferrous materials
and external magnetic fields. Neighboring ferrous materials should
be permitted no closer than 0.5 inches and adjacent external
magnetic fields should be limited to a flux density of less than 5
Gauss.
Isolation
Isolation is the measure of the power level at the output connector
of an unconnected RF channel as referenced to the power at the
input connector. It is specified in dB below the input power level.
SPECIAL FEATURE
Multi-Throw Latching Switch
A multi-throw switch is a switch with one input and three or more
output ports. The CCR-39 can switch a microwave signal to any of
10 outputs from a single common input.
Switching High-Power or Highly Sensitive Signals
Ensure the most linear response with the best galvanically
matched contact system in the industry. Extremely low
passive intermodulation is standard on all of our switches.
Switching Time
Switching time is the total interval beginning with the arrival of the
leading edge of the command pulse at the switch DC input and
ending with the completion of the switch transfer, including contact
bounce. It consists of three parts: (1) inductive delay in the coil, (2)
transfer time of the physical movement of the contacts, and (3) the
bounce time of the RF contacts.
TTL Switch Driver Option
As a special option, switch drivers can be provided for both failsafe
and latching switches, which are compatible with industry-standard
low-power Schottky TTL circuits.
Carrier
Frequency 1
Carrier
Frequency 2
PIM 3rd Order
Frequency
PIM 5th Order
Frequency
870 MHz
893 MHz
847 MHz
824 MHz
Multiple
Positions
3rd Order
Intermodulation
5th Order
Intermodulation
–96 dBm
–115 dBm
–139 dBc
–158 dBc
TD-Option
This option includes a decoder. The 3-bit parallel command is
decoded to internally select the appropriate position. See the logic
tables. The TD-Option increases the Vsw supply current demand
by 50mA max at 28Vdc and +20°C.
Performance Parameters vs Frequency
Generally speaking, the RF performance of coaxial switches is
frequency dependent. With increasing frequency, VSWR and
insertion loss increase while isolation decreases. All data sheets
specify these three parameters as “worst case” at the highest
operating frequency. If the switch is to be used over a narrow
frequency band, better performance can be achieved.
© 2013 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCT-39S/Page 9
CCT-39S\072013\Q3
Series CCT-39S
COAX SWITCHES
Multi-Throw DC-10 GHz, SP9T & SP10T
Latching Coaxial Switch, Internal 50Ω Termination
LATCHING CCT-39S PART NUMBER LIST
PART NO.
CCT-39SX9C
1
*
PART NO.
43
CCT-39SX90-TMS
PART NO.
85
CCT-39SX00-TDS
2
CCT-39SX9C-D
44
CCT-39SX90-TS
86
CCT-39SX00-TM
3
CCT-39SX9C-DM
45
CCT-39SX0C
87
CCT-39SX00-TMS
4
CCT-39SX9C-DR
46
CCT-39SX0C-D
88
CCT-39SX00-TS
5
CCT-39SX9C-DRM
47
CCT-39SX0C-DM
6
CCT-39SX9C-DRS
48
CCT-39SX0C-DR
7
CCT-39SX9C-DS
49
CCT-39SX0C-DRM
8
CCT-39SX9C-M
50
CCT-39SX0C-DRS
9
CCT-39SX9C-MS
51
CCT-39SX0C-DS
10
CCT-39SX9C-R
52
CCT-39SX0C-M
11
CCT-39SX9C-RM
53
CCT-39SX0C-MS
12
CCT-39SX9C-RMS
54
CCT-39SX0C-R
13
CCT-39SX9C-RS
55
CCT-39SX0C-RM
14
CCT-39SX9C-S
56
CCT-39SX0C-RMS
15
CCT-39SX9C-T
57
CCT-39SX0C-RS
16
CCT-39SX9C-TD
58
CCT-39SX0C-S
17
CCT-39SX9C-TDM
39
CCT-39SX0C-T
18
CCT-39SX9C-TDMS
60
CCT-39SX0C-TD
19
CCT-39SX9C-TDS
61
CCT-39SX0C-TDM
20
CCT-39SX9C-TM
62
CCT-39SX0C-TDMS
21
CCT-39SX9C-TMS
63
CCT-39SX0C-TDS
22
CCT-39SX9C-TS
64
CCT-39SX0C-TM
23
CCT-39SX90
65
CCT-39SX0C-TMS
24
CCT-39SX90-D
66
CCT-39SX0C-TS
25
CCT-39SX90-DM
67
CCT-39SX00
26
CCT-39SX90-DR
68
CCT-39SX00-D
27
CCT-39SX90-DRM
69
CCT-39SX00-DM
28
CCT-39SX90-DRS
70
CCT-39SX00-DR
29
CCT-39SX90-DS
71
CCT-39SX00-DRM
30
CCT-39SX90-M
72
CCT-39SX00-DRS
31
CCT-39SX90-MS
73
CCT-39SX00-DS
32
CCT-39SX90-R
74
CCT-39SX00-M
33
CCT-39SX90-RM
75
CCT-39SX00-MS
34
CCT-39SX90-RMS
76
CCT-39SX00-R
35
CCT-39SX90-RS
77
CCT-39SX00-RM
36
CCT-39SX90-S
78
CCT-39SX00-RMS
37
CCT-39SX90-T
79
CCT-39SX00-RS
38
CCT-39SX90-TD
80
CCT-39SX00-S
39
CCT-39SX90-TDM
81
CCT-39SX00-T
40
CCT-39SX90-TDMS
82
CCT-39SX00-TD
41
CCT-39SX90-TDS
83
CCT-39SX00-TDM
42
CCT-39SX90-TM
84
CCT-39SX00-TDMS
X = 6 (28Vdc), 7 (15Vdc), 8 (12Vdc) and 9 (24Vdc)
CCT-39 Page 10
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2013 TELEDYNE COAX SWITCHES
CCT-39S\072013\Q3