WebAccess Configuration Manual ADAM 5000 ADAM 5000 Driver Configuration Manual Version 7.0 rev 0a Advantech Corp., Ltd. page 1 WebAccess Configuration Manual ADAM 5000 Table of Contents ADAM 5000 Driver Configuration Manual 1 1. 2 ADAM 5000 Configuration 1.1 1.2 2. ADAM 5000 ........................................................................................ 2 Module Settings .................................................................................. 3 WebAccess Configuration 2.1 2.2 2.3 2.4 2.5 2.6 4 Port ..................................................................................................... 4 2.1.1 Check the port number .......................................................... 4 2.1.2 WebAccess Comport Page ................................................... 6 2.1.3 Comport Number ................................................................... 6 2.1.4 Description ............................................................................. 6 2.1.5 Baud Rate .............................................................................. 7 2.1.6 Data Bits ................................................................................ 7 2.1.7 Stop Bits ................................................................................ 7 2.1.8 Parity...................................................................................... 7 2.1.9 Scan Time ............................................................................. 7 2.1.10 Timeout .................................................................................. 7 2.1.11 Retry Count ........................................................................... 7 2.1.12 Auto Recover Time ................................................................ 8 2.1.13 Hand Shake RTS................................................................... 8 2.1.14 Hand Shake DTR .................................................................. 8 2.1.15 Backup Port ........................................................................... 9 Device ................................................................................................. 9 2.2.1 Unit Number .......................................................................... 9 Block ................................................................................................... 9 2.3.1 Block Type ........................................................................... 10 2.3.2 Offset ................................................................................... 10 Tag.................................................................................................... 10 2.4.1 Parameter ............................................................................ 11 2.4.2 Address ............................................................................... 11 2.4.3 Scaling Type ........................................................................ 11 Supported Block List ......................................................................... 11 2.5.1 A5013RTD ........................................................................... 11 2.5.2 A5017 .................................................................................. 13 2.5.3 A5017H ................................................................................ 17 2.5.4 A5018 .................................................................................. 21 2.5.5 A5024 .................................................................................. 26 2.5.6 A5051 .................................................................................. 27 2.5.7 A5056 .................................................................................. 28 2.5.8 A5080 .................................................................................. 28 Main Parameter List ......................................................................... 31 Version 7.0 rev 0a Advantech Corp., Ltd. page 1-1 WebAccess Configuration Manual ADAM 5000 1. ADAM 5000 Configuration 1.1 ADAM 5000 The ADAM-5000 Distributed I/O Systems from Advantech are supported by the ADAM5K Device Type drivers in WebAccess. The ADAM5K Device driver reads the IO Modules of the ADAM-5000 directly. The modules contain a RS-485 port. It only has the data+ and dataconnectors. If you want to connect it to an RS-232 port on your computer please use a converter. The ADAM 4520 is a RS-422/485 to RS-232 converter module. Note that when you use a converter the baud rate of the converter must be set to 9600bps and the handshaking of the converter should match the handshaking setting on your computer. Version 7.0 rev 0a Advantech Corp., Ltd. page 2 WebAccess Configuration Manual 1.2 ADAM 5000 Module Settings Start your module while linking the init connector to the ground (to enable the initial mode) and connect it to the computer. On the computer start the Adam/Apax .NET Utility The module will automatically appear in the left tree under the serial port it is connected to. If you are using virtual com port from (EKI serial server) or USB to serial adapters you need to refresh the com port list first and then the module list. The * next to the module name means it is in initial mode. Make sure that the protocol is Advantech and note the Address, baud rate and checksum as they will be required in WebAccess settings. Version 7.0 rev 0a Advantech Corp., Ltd. page 3 WebAccess Configuration Manual ADAM 5000 Then close the utility and restart the module. 2. WebAccess Configuration 2.1 Port The ADAM5K protocol uses a serial port. Even if you use a serial port server or a USB to serial converter the apparent port in your computer (and therefore the port to select in WebAccess) is a serial port. 2.1.1 Check the port number If you are using a comport emulator and you do not know the port number then open the “Start Menu” and right click on “Computer” and select “Manage” In the device manager section you can see the list of COM ports on your computer and recognize the virtual port by its driver name Version 7.0 rev 0a Advantech Corp., Ltd. page 4 WebAccess Configuration Manual Version 7.0 rev 0a ADAM 5000 Advantech Corp., Ltd. page 5 WebAccess Configuration Manual 2.1.2 ADAM 5000 WebAccess Comport Page Open your WebAccess Configuration and select the SCADA node you want to add the device to. Then select “Add a new Comport” All the settings in this page must match the settings in all the modules attached to the port. So all the modules attached to the same comport must have the same settings. 2.1.3 Comport Number The Serial Comport requires the comport number to match that of the physical interface (e.g. COM1, COM2, COM3, etc) on the SCADA Node. 2.1.4 Description This is an optional field used for user reference. Version 7.0 rev 0a Advantech Corp., Ltd. page 6 WebAccess Configuration Manual ADAM 5000 2.1.5 Baud Rate For the Adam 5K modules the typical baud rate is 9600. This must match the baud rate configured in the module and the eventual RS485 to RS-232 converter. 2.1.6 Data Bits The packets can have 7 or 8 Data Bits. The typical setting for Adam 5K is 8 bits. 2.1.7 Stop Bits The packets can have 1 or 2 Stop Bits. The typical setting for Adam 5K is 1 Stop bit. 2.1.8 Parity The Parity can be None, Odd, Even or Disabled. The typical setting for Adam 5K is Parity = None. 2.1.9 Scan Time This is the time in milliseconds to scan the Devices. This must match the ability of the device to respond. A typical scan rate is 1 per second. If the Device cannot respond as fast as the SCAN Time entered, WebAccess will scan at a slower rate. 2.1.10 Timeout With a 1 second scan rate, a typical Time Out = 200 Milliseconds. Timeout is the time waited before re-sending a communications packet that did not have a reply. Timeout specifies how long the software waits for a response to a data request, specifically to wait for a reply from one packet. A recommended value is one-fifth the scan rate, longer if the communication device is slow. Combined with Retry count, Timeout also determines time to consider a device or port as BAD. Timeout is the time to wait since last communication packet sent without a reply. Time is in milliseconds. Slow or poor quality communications require longer timeout. The faster the communications, the shorter the timeout required. Shorter timeouts result in faster reconnects after communication failures. 2.1.11 Retry Count A typical Retry count = 3. Version 7.0 rev 0a Advantech Corp., Ltd. page 7 WebAccess Configuration Manual ADAM 5000 Number of times to retry communications if no reply is received from a device. Combined with Timeout, also determines time to consider a device or port as BAD. This is the number of times after the first attempt has failed that communication should be attempted before indicating a failure. (If Retry count is 3, a total of 4 failed requests have occurred before tags are marked bad). Specifically, this is how many times to send a single packet after the field device fails to respond to the first packet. After the retry count is exceeded, all the tags in the packet are marked with asterisks and the next packet of requests is sent. A reasonable value is 3 to 5 times. After this number of tries, the tags in this packet are marked as "fail to respond" (i.e. asterisks) and are disabled. In reality, increasing the number of retries hides failures on the part of the field device to respond to a request. Essentially, increasing the retries gives the field device more chances to reply. 2.1.12 Auto Recover Time A typical Auto Recover Time = 60 Seconds. Auto Recover Time is the time to wait before attempting to re-establish communications with a BAD device or port. If communications to the PLC is unusually slow due to hardware, communications or network issues, you might consider increasing this value. If communications to the PLC or RTU fails frequently, you may want to decrease this number in order to have WebAccess try to re-establish communications sooner. If communications to the PLC, RTU or device Fails (i.e. exceeds Timeout) WebAccess will wait the Auto Recover Time before trying to re-establish communications. 2.1.13 Hand Shake RTS The typical setting for Adam 5K is HandShakeRts = No. The RTS (Request To Send) signal is raised and lowered on the Serial Communications Port if this value set to Yes. RTS is determined by settings in the field device. Refer to your device interface manual to determine the value for this field and the type of cable used. 2.1.14 Hand Shake DTR The typical setting for Adam 5K is HandShakeDtr = No. The DTR (Data Terminal Ready) signal raised and lowered on the Serial Communications Port if this value is set to Yes. DTR is determined by settings in the field device and the type of cable used. Version 7.0 rev 0a Advantech Corp., Ltd. page 8 WebAccess Configuration Manual ADAM 5000 2.1.15 Backup Port The Backup Port has not been tested for Adam 5K 2.2 Device Then Go to the port page and select “Add a new device”. Select the ADAM5K device Type. 2.2.1 Unit Number The Unit number must match the “unit number” (or “address”) set in the module. 2.3 Block To allow users to add Adam 5K modules easily in WebAccess we created a block for each module. The block contains all the tags of the module and will allow an easy access and display. Version 7.0 rev 0a Advantech Corp., Ltd. page 9 WebAccess Configuration Manual 2.3.1 ADAM 5000 Block Type The block type allows you to select which group of parameters you want to import (Counter, PID, I/O …). For Adam 5K select the module type. It will add all the channels and parameters available in the device. Each Slot contains a different module so you should add a block for each slot. 2.3.2 Offset The offset should correspond to the address of the first parameter of the block. All the other parameters addresses will then be calculated based on the first one. In the ADAM4K driver the offset format is: 5017,1,0 The first number should correspond to the device type and the second one to the slot number; leave the third one to 0. 2.4 Tag If you do not use all the channels in the device and you want to reduce your tag count you can add the parameters one by one using “Add tag”. Version 7.0 rev 0a Advantech Corp., Ltd. page 10 WebAccess Configuration Manual 2.4.1 ADAM 5000 Parameter The parameter gives the type of tag you want to import. Try to select a parameter as close to the tag type as possible because it will fill the other option with the default parameters. In Adam 5K almost all the available tags have been put to the parameter list so by choosing the correct one all the other fields are set automatically. 2.4.2 Address For Adam 5K the address starts with the module type (replace 0 by 5017) followed by the slot number (here 0). The last number should correspond to the channel number (0 for the AI 0). 2.4.3 Scaling Type If the data sent by the module is not in a human readable unit you can use the scaling to change the unit and display a more convenient unit in the node. In most cases a linear scaling type will be sufficient. 2.5 Supported Block List There is a block for each ADAM module. The block contain all the possible parameters in the module. Here are a few of our most used blocks. 2.5.1 A5013RTD 3-ch RTD Input Module Parameter Version 7.0 rev 0a Description Advantech Corp., Ltd. page 11 WebAccess Configuration Manual ADAM 5000 Parameter Description A0_H_C Alarm H Channel Link A0_H_LMT High Alarm Limit A0_H_S Alarm H Slot Connection A0_L_C Alarm L Channel Link A0_L_LMT Low Alarm Limit A0_L_S Alarm L Slot Connection A0_H_MOD High Alarm Mode A0_H_STS High Alarm Status A0_L_MOD Low Alarm Mode A0_L_STS Low Alarm Status A1_H_C Alarm H Channel Link A1_H_LMT High Alarm Limit A1_H_S Alarm H Slot Connection A1_L_C Alarm L Channel Link A1_L_LMT Low Alarm Limit A1_L_S Alarm L Slot Connection A1_H_MOD High Alarm Mode A1_H_STS High Alarm Status A1_L_MOD Low Alarm Mode A1_L_STS Low Alarm Status A2_H_C Alarm H Channel Link A2_H_LMT High Alarm Limit A2_H_S Alarm H Slot Connection A2_L_C Alarm L Channel Link A2_L_LMT Low Alarm Limit A2_L_S Alarm L Slot Connection A2_H_MOD High Alarm Mode Version 7.0 rev 0a Advantech Corp., Ltd. page 12 WebAccess Configuration Manual ADAM 5000 Parameter Description A2_H_STS High Alarm Status A2_L_MOD Low Alarm Mode A2_L_STS Low Alarm Status AI_0 Analog Input AI_0_ST Multiplexing Status AI_1 Analog Input AI_1_ST Multiplexing Status AI_2 Analog Input AI_2_ST Multiplexing Status AI_FMT Data Format AI_INI Initialize EEPROM AI_IT Integration Time AI_Range Range AI_SCL RTD Self Calibration AI_SPCL Span Clibration AI_ZCL Zero Calibration 2.5.2 A5017 8-ch Analog Input Module Parameter Description A0_H_C Alarm H Channel Link A0_H_LMT High Alarm Limit A0_H_S Alarm H Slot Connection A0_L_C Alarm L Channel Link A0_L_LMT Low Alarm Limit A0_L_S Alarm L Slot Connection A0_H_MOD High Alarm Mode Version 7.0 rev 0a Advantech Corp., Ltd. page 13 WebAccess Configuration Manual ADAM 5000 Parameter Description A0_H_STS High Alarm Status A0_L_MOD Low Alarm Mode A0_L_STS Low Alarm Status A1_H_C Alarm H Channel Link A1_H_LMT High Alarm Limit A1_H_S Alarm H Slot Connection A1_L_C Alarm L Channel Link A1_L_LMT Low Alarm Limit A1_L_S Alarm L Slot Connection A1_H_MOD High Alarm Mode A1_H_STS High Alarm Status A1_L_MOD Low Alarm Mode A1_L_STS Low Alarm Status A2_H_C Alarm H Channel Link A2_H_LMT High Alarm Limit A2_H_S Alarm H Slot Connection A2_L_C Alarm L Channel Link A2_L_LMT Low Alarm Limit A2_L_S Alarm L Slot Connection A2_H_MOD High Alarm Mode A2_H_STS High Alarm Status A2_L_MOD Low Alarm Mode A2_L_STS Low Alarm Status A3_H_C Alarm H Channel Link A3_H_LMT High Alarm Limit A3_H_S Alarm H Slot Connection A3_L_C Alarm L Channel Link Version 7.0 rev 0a Advantech Corp., Ltd. page 14 WebAccess Configuration Manual ADAM 5000 Parameter Description A3_L_LMT Low Alarm Limit A3_L_S Alarm L Slot Connection A3_H_MOD High Alarm Mode A3_H_STS High Alarm Status A3_L_MOD Low Alarm Mode A3_L_STS Low Alarm Status A4_H_C Alarm H Channel Link A4_H_LMT High Alarm Limit A4_H_S Alarm H Slot Connection A4_L_C Alarm L Channel Link A4_L_LMT Low Alarm Limit A4_L_S Alarm L Slot Connection A4_H_MOD High Alarm Mode A4_H_STS High Alarm Status A4_L_MOD Low Alarm Mode A4_L_STS Low Alarm Status A5_H_C Alarm H Channel Link A5_H_LMT High Alarm Limit A5_H_S Alarm H Slot Connection A5_L_C Alarm L Channel Link A5_L_LMT Low Alarm Limit A5_L_S Alarm L Slot Connection A5_H_MOD High Alarm Mode A5_H_STS High Alarm Status A5_L_MOD Low Alarm Mode A5_L_STS Low Alarm Status A6_H_C Alarm H Channel Link Version 7.0 rev 0a Advantech Corp., Ltd. page 15 WebAccess Configuration Manual ADAM 5000 Parameter Description A6_H_LMT High Alarm Limit A6_H_S Alarm H Slot Connection A6_L_C Alarm L Channel Link A6_L_LMT Low Alarm Limit A6_L_S Alarm L Slot Connection A6_H_MOD High Alarm Mode A6_H_STS High Alarm Status A6_L_MOD Low Alarm Mode A6_L_STS Low Alarm Status A7_H_C Alarm H Channel Link A7_H_LMT High Alarm Limit A7_H_S Alarm H Slot Connection A7_L_C Alarm L Channel Link A7_L_LMT Low Alarm Limit A7_L_S Alarm L Slot Connection A7_H_MOD High Alarm Mode A7_H_STS High Alarm Status A7_L_MOD Low Alarm Mode A7_L_STS Low Alarm Status AI_0 Analog Input AI_0_ST Multiplexing Status AI_1 Analog Input AI_1_ST Multiplexing Status AI_2 Analog Input AI_2_ST Multiplexing Status AI_3 Analog Input AI_3_ST Multiplexing Status Version 7.0 rev 0a Advantech Corp., Ltd. page 16 WebAccess Configuration Manual ADAM 5000 Parameter Description AI_4 Analog Input AI_4_ST Multiplexing Status AI_5 Analog Input AI_5_ST Multiplexing Status AI_6 Analog Input AI_6_ST Multiplexing Status AI_7 Analog Input AI_7_ST Multiplexing Status AI_CJC AI Cold Junction Compensation AI_FMT Data Format AI_INI Initialize EEPROM AI_IT Integration Time AI_Range Range AI_SCL RTD Self Calibration AI_SPCL Span Clibration AI_ZCL Zero Calibration 2.5.3 A5017H 8-channel High-speed Analog Input Module Parameter Description A0_H_C Alarm H Channel Link A0_H_LMT High Alarm Limit A0_H_S Alarm H Slot Connection A0_L_C Alarm L Channel Link A0_L_LMT Low Alarm Limit A0_L_S Alarm L Slot Connection A0_H_MOD High Alarm Mode Version 7.0 rev 0a Advantech Corp., Ltd. page 17 WebAccess Configuration Manual ADAM 5000 Parameter Description A0_H_STS High Alarm Status A0_L_MOD Low Alarm Mode A0_L_STS Low Alarm Status A1_H_C Alarm H Channel Link A1_H_LMT High Alarm Limit A1_H_S Alarm H Slot Connection A1_L_C Alarm L Channel Link A1_L_LMT Low Alarm Limit A1_L_S Alarm L Slot Connection A1_H_MOD High Alarm Mode A1_H_STS High Alarm Status A1_L_MOD Low Alarm Mode A1_L_STS Low Alarm Status A2_H_C Alarm H Channel Link A2_H_LMT High Alarm Limit A2_H_S Alarm H Slot Connection A2_L_C Alarm L Channel Link A2_L_LMT Low Alarm Limit A2_L_S Alarm L Slot Connection A2_H_MOD High Alarm Mode A2_H_STS High Alarm Status A2_L_MOD Low Alarm Mode A2_L_STS Low Alarm Status A3_H_C Alarm H Channel Link A3_H_LMT High Alarm Limit A3_H_S Alarm H Slot Connection A3_L_C Alarm L Channel Link Version 7.0 rev 0a Advantech Corp., Ltd. page 18 WebAccess Configuration Manual ADAM 5000 Parameter Description A3_L_LMT Low Alarm Limit A3_L_S Alarm L Slot Connection A3_H_MOD High Alarm Mode A3_H_STS High Alarm Status A3_L_MOD Low Alarm Mode A3_L_STS Low Alarm Status A4_H_C Alarm H Channel Link A4_H_LMT High Alarm Limit A4_H_S Alarm H Slot Connection A4_L_C Alarm L Channel Link A4_L_LMT Low Alarm Limit A4_L_S Alarm L Slot Connection A4_H_MOD High Alarm Mode A4_H_STS High Alarm Status A4_L_MOD Low Alarm Mode A4_L_STS Low Alarm Status A5_H_C Alarm H Channel Link A5_H_LMT High Alarm Limit A5_H_S Alarm H Slot Connection A5_L_C Alarm L Channel Link A5_L_LMT Low Alarm Limit A5_L_S Alarm L Slot Connection A5_H_MOD High Alarm Mode A5_H_STS High Alarm Status A5_L_MOD Low Alarm Mode A5_L_STS Low Alarm Status A6_H_C Alarm H Channel Link Version 7.0 rev 0a Advantech Corp., Ltd. page 19 WebAccess Configuration Manual ADAM 5000 Parameter Description A6_H_LMT High Alarm Limit A6_H_S Alarm H Slot Connection A6_L_C Alarm L Channel Link A6_L_LMT Low Alarm Limit A6_L_S Alarm L Slot Connection A6_H_MOD High Alarm Mode A6_H_STS High Alarm Status A6_L_MOD Low Alarm Mode A6_L_STS Low Alarm Status A7_H_C Alarm H Channel Link A7_H_LMT High Alarm Limit A7_H_S Alarm H Slot Connection A7_L_C Alarm L Channel Link A7_L_LMT Low Alarm Limit A7_L_S Alarm L Slot Connection A7_H_MOD High Alarm Mode A7_H_STS High Alarm Status A7_L_MOD Low Alarm Mode A7_L_STS Low Alarm Status AI_0 Analog Input AI_0_R Range AI_0_ST Multiplexing Status AI_1 Analog Input AI_1_R Range AI_1_ST Multiplexing Status AI_2 Analog Input AI_2_R Range Version 7.0 rev 0a Advantech Corp., Ltd. page 20 WebAccess Configuration Manual ADAM 5000 Parameter Description AI_2_ST Multiplexing Status AI_3 Analog Input AI_3_R Range AI_3_ST Multiplexing Status AI_4 Analog Input AI_4_R Range AI_4_ST Multiplexing Status AI_5 Analog Input AI_5_R Range AI_5_ST Multiplexing Status AI_6 Analog Input AI_6_R Range AI_6_ST Multiplexing Status AI_7 Analog Input AI_7_R Range AI_7_ST Multiplexing Status AI_INI Initialize EEPROM AI_SPCL Span Clibration AI_ZCL Zero Calibration 2.5.4 A5018 7-ch Thermocouple Input Module Parameter Description A0_H_C Alarm H Channel Link A0_H_LMT High Alarm Limit A0_H_S Alarm H Slot Connection A0_L_C Alarm L Channel Link Version 7.0 rev 0a Advantech Corp., Ltd. page 21 WebAccess Configuration Manual ADAM 5000 Parameter Description A0_L_LMT Low Alarm Limit A0_L_S Alarm L Slot Connection A0_H_MOD High Alarm Mode A0_H_STS High Alarm Status A0_L_MOD Low Alarm Mode A0_L_STS Low Alarm Status A1_H_C Alarm H Channel Link A1_H_LMT High Alarm Limit A1_H_S Alarm H Slot Connection A1_L_C Alarm L Channel Link A1_L_LMT Low Alarm Limit A1_L_S Alarm L Slot Connection A1_H_MOD High Alarm Mode A1_H_STS High Alarm Status A1_L_MOD Low Alarm Mode A1_L_STS Low Alarm Status A2_H_C Alarm H Channel Link A2_H_LMT High Alarm Limit A2_H_S Alarm H Slot Connection A2_L_C Alarm L Channel Link A2_L_LMT Low Alarm Limit A2_L_S Alarm L Slot Connection A2_H_MOD High Alarm Mode A2_H_STS High Alarm Status A2_L_MOD Low Alarm Mode A2_L_STS Low Alarm Status A3_H_C Alarm H Channel Link Version 7.0 rev 0a Advantech Corp., Ltd. page 22 WebAccess Configuration Manual ADAM 5000 Parameter Description A3_H_LMT High Alarm Limit A3_H_S Alarm H Slot Connection A3_L_C Alarm L Channel Link A3_L_LMT Low Alarm Limit A3_L_S Alarm L Slot Connection A3_H_MOD High Alarm Mode A3_H_STS High Alarm Status A3_L_MOD Low Alarm Mode A3_L_STS Low Alarm Status A4_H_C Alarm H Channel Link A4_H_LMT High Alarm Limit A4_H_S Alarm H Slot Connection A4_L_C Alarm L Channel Link A4_L_LMT Low Alarm Limit A4_L_S Alarm L Slot Connection A4_H_MOD High Alarm Mode A4_H_STS High Alarm Status A4_L_MOD Low Alarm Mode A4_L_STS Low Alarm Status A5_H_C Alarm H Channel Link A5_H_LMT High Alarm Limit A5_H_S Alarm H Slot Connection A5_L_C Alarm L Channel Link A5_L_LMT Low Alarm Limit A5_L_S Alarm L Slot Connection A5_H_MOD High Alarm Mode A5_H_STS High Alarm Status Version 7.0 rev 0a Advantech Corp., Ltd. page 23 WebAccess Configuration Manual ADAM 5000 Parameter Description A5_L_MOD Low Alarm Mode A5_L_STS Low Alarm Status A6_H_C Alarm H Channel Link A6_H_LMT High Alarm Limit A6_H_S Alarm H Slot Connection A6_L_C Alarm L Channel Link A6_L_LMT Low Alarm Limit A6_L_S Alarm L Slot Connection A6_H_MOD High Alarm Mode A6_H_STS High Alarm Status A6_L_MOD Low Alarm Mode A6_L_STS Low Alarm Status A7_H_C Alarm H Channel Link A7_H_LMT High Alarm Limit A7_H_S Alarm H Slot Connection A7_L_C Alarm L Channel Link A7_L_LMT Low Alarm Limit A7_L_S Alarm L Slot Connection A7_H_MOD High Alarm Mode A7_H_STS High Alarm Status A7_L_MOD Low Alarm Mode A7_L_STS Low Alarm Status AI_0 Analog Input AI_0_CJC Cold Junc. Comp. AI_0_R Range AI_0_ST Multiplexing Status AI_1 Analog Input Version 7.0 rev 0a Advantech Corp., Ltd. page 24 WebAccess Configuration Manual ADAM 5000 Parameter Description AI_1_CJC Cold Junc. Comp. AI_1_R Range AI_1_ST Multiplexing Status AI_2 Analog Input AI_2_CJC Cold Junc. Comp. AI_2_R Range AI_2_ST Multiplexing Status AI_3 Analog Input AI_3_CJC Cold Junc. Comp. AI_3_R Range AI_3_ST Multiplexing Status AI_4 Analog Input AI_4_CJC Cold Junc. Comp. AI_4_R Range AI_4_ST Multiplexing Status AI_5 Analog Input AI_5_CJC Cold Junc. Comp. AI_5_R Range AI_5_ST Multiplexing Status AI_6 Analog Input AI_6_CJC Cold Junc. Comp. AI_6_R Range AI_6_ST Multiplexing Status AI_7 Analog Input AI_7_CJC Cold Junc. Comp. AI_7_R Range AI_7_ST Multiplexing Status Version 7.0 rev 0a Advantech Corp., Ltd. page 25 WebAccess Configuration Manual 2.5.5 ADAM 5000 A5024 4-ch Analog Output Module Parameter Description AO_0 Analog Output AO_0_SLW Slew Rate AO_0_TCL Trim Calibration AO_0_20C 20mA Calibration AO_0_4CL 4mA Calibration AO_0_FMT Data Format AO_0_R Range AO_0_ST Set Startup Value AO_1 Analog Output AO_1_SLW Slew Rate AO_1_TCL Trim Calibration AO_1_20C 20mA Calibration AO_1_4CL 4mA Calibration AO_1_FMT Data Format AO_1_R Range AO_1_ST Set Startup Value AO_2 Analog Output AO_2_SLW Slew Rate AO_2_TCL Trim Calibration AO_2_20C 20mA Calibration AO_2_4CL 4mA Calibration AO_2_FMT Data Format AO_2_R Range AO_2_ST Set Startup Value Version 7.0 rev 0a Advantech Corp., Ltd. page 26 WebAccess Configuration Manual ADAM 5000 Parameter Description AO_3 Analog Output AO_3_SLW Slew Rate AO_3_TCL Trim Calibration AO_3_20C 20mA Calibration AO_3_4CL 4mA Calibration AO_3_FMT Data Format AO_3_R Range AO_3_ST Set Startup Value 2.5.6 A5051 16-ch Digital Input Module Parameter Description DI_00 Digital Input DI_01 Digital Input DI_02 Digital Input DI_03 Digital Input DI_04 Digital Input DI_05 Digital Input DI_06 Digital Input DI_07 Digital Input DI_08 Digital Input DI_09 Digital Input DI_10 Digital Input DI_11 Digital Input DI_12 Digital Input DI_13 Digital Input DI_14 Digital Input Version 7.0 rev 0a Advantech Corp., Ltd. page 27 WebAccess Configuration Manual ADAM 5000 Parameter Description DI_15 Digital Input 2.5.7 A5056 16-ch Digital Output Module Parameter Description DO_00M Masking Status DO_01M Masking Status DO_02M Masking Status DO_03M Masking Status DO_04M Masking Status DO_05M Masking Status DO_06M Masking Status DO_07M Masking Status DO_08M Masking Status DO_09M Masking Status DO_10M Masking Status DO_11M Masking Status DO_12M Masking Status DO_13M Masking Status DO_14M Masking Status DO_15M Masking Status 2.5.8 A5080 4-ch Counter/Frequency Module Parameter Description A0_H_C Alarm H Channel Link A0_H_LMT High Alarm Limit Version 7.0 rev 0a Advantech Corp., Ltd. page 28 WebAccess Configuration Manual ADAM 5000 Parameter Description A0_H_S Alarm H Slot Connection A0_L_C Alarm L Channel Link A0_L_LMT Low Alarm Limit A0_L_S Alarm L Slot Connection A0_H_MOD High Alarm Mode A0_H_STS High Alarm Status A0_L_MOD Low Alarm Mode A0_L_STS Low Alarm Status A1_H_C Alarm H Channel Link A1_H_LMT High Alarm Limit A1_H_S Alarm H Slot Connection A1_L_C Alarm L Channel Link A1_L_LMT Low Alarm Limit A1_L_S Alarm L Slot Connection A1_H_MOD High Alarm Mode A1_H_STS High Alarm Status A1_L_MOD Low Alarm Mode A1_L_STS Low Alarm Status A2_H_C Alarm H Channel Link A2_H_LMT High Alarm Limit A2_H_S Alarm H Slot Connection A2_L_C Alarm L Channel Link A2_L_LMT Low Alarm Limit A2_L_S Alarm L Slot Connection A2_H_MOD High Alarm Mode A2_H_STS High Alarm Status A2_L_MOD Low Alarm Mode Version 7.0 rev 0a Advantech Corp., Ltd. page 29 WebAccess Configuration Manual ADAM 5000 Parameter Description A2_L_STS Low Alarm Status A3_H_C Alarm H Channel Link A3_H_LMT High Alarm Limit A3_H_S Alarm H Slot Connection A3_L_C Alarm L Channel Link A3_L_LMT Low Alarm Limit A3_L_S Alarm L Slot Connection A3_H_MOD High Alarm Mode A3_H_STS High Alarm Status A3_L_MOD Low Alarm Mode A3_L_STS Low Alarm Status CF_0 Counter Data CF_0_INI Counter Initial Value CF_0_CLR Clear CF CF_0_OVR Overflow Flag CF_0_ST Status CF_1 Counter Data CF_1_INI Counter Initial Value CF_1_CLR Clear CF CF_1_OVR Overflow Flag CF_1_ST Status CF_2 Counter Data CF_2_INI Counter Initial Value CF_2_CLR Clear CF CF_2_OVR Overflow Flag CF_2_ST Status CF_3 Counter Data Version 7.0 rev 0a Advantech Corp., Ltd. page 30 WebAccess Configuration Manual ADAM 5000 Parameter Description CF_3_INI Counter Initial Value CF_3_CLR Clear CF CF_3_OVR Overflow Flag CF_3_ST Status CF_FILTER C/F Filter CF_FMT C/F Data Format CF_MODE C/F Mode 2.6 Main Parameter List Parameter Description A0_H_C Alarm H Channel Link A0_H_LMT High Alarm Limit A0_H_S Alarm H Slot Connection A0_L_C Alarm L Channel Link A0_L_LMT Low Alarm Limit A0_L_S Alarm L Slot Connection A1_H_C Alarm H Channel Link A1_H_LMT High Alarm Limit A1_H_S Alarm H Slot Connection A1_L_C Alarm L Channel Link A1_L_LMT Low Alarm Limit A1_L_S Alarm L Slot Connection A2_H_C Alarm H Channel Link A2_H_LMT High Alarm Limit Version 7.0 rev 0a Advantech Corp., Ltd. page 31 WebAccess Configuration Manual ADAM 5000 Parameter Description A2_H_S Alarm H Slot Connection A2_L_C Alarm L Channel Link A2_L_LMT Low Alarm Limit A2_L_S Alarm L Slot Connection A3_H_C Alarm H Channel Link A3_H_LMT High Alarm Limit A3_H_S Alarm H Slot Connection A3_L_C Alarm L Channel Link A3_L_LMT Low Alarm Limit A3_L_S Alarm L Slot Connection A4_H_C Alarm H Channel Link A4_H_LMT High Alarm Limit A4_H_S Alarm H Slot Connection A4_L_C Alarm L Channel Link A4_L_LMT Low Alarm Limit A4_L_S Alarm L Slot Connection A5_H_C Alarm H Channel Link A5_H_LMT High Alarm Limit A5_H_S Alarm H Slot Connection A5_L_C Alarm L Channel Link A5_L_LMT Low Alarm Limit A5_L_S Alarm L Slot Connection A6_H_C Alarm H Channel Link A6_H_LMT High Alarm Limit A6_H_S Alarm H Slot Connection A6_L_C Alarm L Channel Link A6_L_LMT Low Alarm Limit Version 7.0 rev 0a Advantech Corp., Ltd. page 32 WebAccess Configuration Manual ADAM 5000 Parameter Description A6_L_S Alarm L Slot Connection A7_H_C Alarm H Channel Link A7_H_LMT High Alarm Limit A7_H_S Alarm H Slot Connection A7_L_C Alarm L Channel Link A7_L_LMT Low Alarm Limit A7_L_S Alarm L Slot Connection AI_0 Analog Input AI_0_CJC Cold Junc. Comp. AI_0_R Range AI_1 Analog Input AI_1_CJC Cold Junc. Comp. AI_1_R Range AI_2 Analog Input AI_2_CJC Cold Junc. Comp. AI_2_R Range AI_3 Analog Input AI_3_CJC Cold Junc. Comp. AI_3_R Range AI_4 Analog Input AI_4_CJC Cold Junc. Comp. AI_4_R Range AI_5 Analog Input AI_5_CJC Cold Junc. Comp. AI_5_R Range AI_6 Analog Input AI_6_CJC Cold Junc. Comp. Version 7.0 rev 0a Advantech Corp., Ltd. page 33 WebAccess Configuration Manual ADAM 5000 Parameter Description AI_6_R Range AI_7 Analog Input AI_7_CJC Cold Junc. Comp. AI_7_R Range AI_CJC AI Cold Junction Compensation AI_RANGE AI Range AO_0 Analog Output AO_0_SLW Slew Rate AO_0_TCL Trim Calibration AO_1 Analog Output AO_1_SLW Slew Rate AO_1_TCL Trim Calibration AO_2 Analog Output AO_2_SLW Slew Rate AO_2_TCL Trim Calibration AO_3 Analog Output AO_3_SLW Slew Rate AO_3_TCL Trim Calibration CF_0 Counter Data CF_0_INI Counter Initial Value CF_1 Counter Data CF_1_INI Counter Initial Value CF_2 Counter Data CF_2_INI Counter Initial Value CF_3 Counter Data CF_3_INI Counter Initial Value CF_FILTER Counter Filter Version 7.0 rev 0a Advantech Corp., Ltd. page 34 WebAccess Configuration Manual ADAM 5000 Parameter Description A0_H_MOD High Alarm Mode A0_H_STS High Alarm Status A0_L_MOD Low Alarm Mode A0_L_STS Low Alarm Status A1_H_MOD High Alarm Mode A1_H_STS High Alarm Status A1_L_MOD Low Alarm Mode A1_L_STS Low Alarm Status A2_H_MOD High Alarm Mode A2_H_STS High Alarm Status A2_L_MOD Low Alarm Mode A2_L_STS Low Alarm Status A3_H_MOD High Alarm Mode A3_H_STS High Alarm Status A3_L_MOD Low Alarm Mode A3_L_STS Low Alarm Status A4_H_MOD High Alarm Mode A4_H_STS High Alarm Status A4_L_MOD Low Alarm Mode A4_L_STS Low Alarm Status A5_H_MOD High Alarm Mode A5_H_STS High Alarm Status A5_L_MOD Low Alarm Mode A5_L_STS Low Alarm Status A6_H_MOD High Alarm Mode A6_H_STS High Alarm Status A6_L_MOD Low Alarm Mode Version 7.0 rev 0a Advantech Corp., Ltd. page 35 WebAccess Configuration Manual ADAM 5000 Parameter Description A6_L_STS Low Alarm Status A7_H_MOD High Alarm Mode A7_H_STS High Alarm Status A7_L_MOD Low Alarm Mode A7_L_STS Low Alarm Status AI_0_FMT Data Format AI_0_INI Initialize EEPROM AI_0_IT Integration Time AI_0_SCL Span Calibration AI_0_ST Multiplexing Status AI_0_ZCL Zero Calibration AI_1_FMT Data Format AI_1_INI Initialize EEPROM AI_1_IT Integration Time AI_1_SCL Span Calibration AI_1_ST Multiplexing Status AI_1_ZCL Zero Calibration AI_2_FMT Data Format AI_2_INI Initialize EEPROM AI_2_IT Integration Time AI_2_SCL Span Calibration AI_2_ST Multiplexing Status AI_2_ZCL Zero Calibration AI_3_FMT Data Format AI_3_INI Initialize EEPROM AI_3_IT Integration Time AI_3_SCL Span Calibration Version 7.0 rev 0a Advantech Corp., Ltd. page 36 WebAccess Configuration Manual ADAM 5000 Parameter Description AI_3_ST Multiplexing Status AI_3_ZCL Zero Calibration AI_4_FMT Data Format AI_4_INI Initialize EEPROM AI_4_IT Integration Time AI_4_SCL Span Calibration AI_4_ST Multiplexing Status AI_4_ZCL Zero Calibration AI_5_FMT Data Format AI_5_INI Initialize EEPROM AI_5_IT Integration Time AI_5_SCL Span Calibration AI_5_ST Multiplexing Status AI_5_ZCL Zero Calibration AI_6_FMT Data Format AI_6_INI Initialize EEPROM AI_6_IT Integration Time AI_6_SCL Span Calibration AI_6_ST Multiplexing Status AI_6_ZCL Zero Calibration AI_7_FMT Data Format AI_7_INI Initialize EEPROM AI_7_IT Integration Time AI_7_SCL Span Calibration AI_7_ST Multiplexing Status AI_7_ZCL Zero Calibration AI_FMT Data Format Version 7.0 rev 0a Advantech Corp., Ltd. page 37 WebAccess Configuration Manual ADAM 5000 Parameter Description AI_INI Initialize EEPROM AI_IT Integration Time AI_SCL RTD Self Calibration AI_SPCL Span Clibration AI_ZCL Zero Calibration AO_0_20C 20mA Calibration AO_0_4CL 4mA Calibration AO_0_FMT Data Format AO_0_R Range AO_0_ST Set Startup Value AO_1_20C 20mA Calibration AO_1_4CL 4mA Calibration AO_1_FMT Data Format AO_1_R Range AO_1_ST Set Startup Value AO_2_20C 20mA Calibration AO_2_4CL 4mA Calibration AO_2_FMT Data Format AO_2_R Range AO_2_ST Set Startup Value AO_3_20C 20mA Calibration AO_3_4CL 4mA Calibration AO_3_FMT Data Format AO_3_R Range AO_3_ST Set Startup Value CF_0_CLR Clear CF CF_0_OVR Overflow Flag Version 7.0 rev 0a Advantech Corp., Ltd. page 38 WebAccess Configuration Manual ADAM 5000 Parameter Description CF_0_ST Status CF_1_CLR Clear CF CF_1_OVR Overflow Flag CF_1_ST Status CF_2_CLR Clear CF CF_2_OVR Overflow Flag CF_2_ST Status CF_3_CLR Clear CF CF_3_OVR Overflow Flag CF_3_ST Status CF_FMT C/F Data Format CF_MODE C/F Mode DI_00 Digital Input DI_01 Digital Input DI_02 Digital Input DI_03 Digital Input DI_04 Digital Input DI_05 Digital Input DI_06 Digital Input DI_07 Digital Input DI_08 Digital Input DI_09 Digital Input DI_10 Digital Input DI_11 Digital Input DI_12 Digital Input DI_13 Digital Input DI_14 Digital Input Version 7.0 rev 0a Advantech Corp., Ltd. page 39 WebAccess Configuration Manual ADAM 5000 Parameter Description DI_15 Digital Input DO_00 Digital Output DO_01 Digital Output DO_02 Digital Output DO_03 Digital Output DO_04 Digital Output DO_05 Digital Output DO_06 Digital Output DO_07 Digital Output DO_08 Digital Output DO_09 Digital Output DO_10 Digital Output DO_11 Digital Output DO_12 Digital Output DO_13 Digital Output DO_14 Digital Output DO_15 Digital Output DO_00M Masking Status DO_01M Masking Status DO_02M Masking Status DO_03M Masking Status DO_04M Masking Status DO_05M Masking Status DO_06M Masking Status DO_07M Masking Status DO_08M Masking Status DO_09M Masking Status Version 7.0 rev 0a Advantech Corp., Ltd. page 40 WebAccess Configuration Manual ADAM 5000 Parameter Description DO_10M Masking Status DO_11M Masking Status DO_12M Masking Status DO_13M Masking Status DO_14M Masking Status DO_15M Masking Status Version 7.0 rev 0a Advantech Corp., Ltd. page 41