Advantech ADAM 5K

WebAccess Configuration Manual
ADAM 5000
ADAM 5000 Driver
Configuration Manual
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 1
WebAccess Configuration Manual
ADAM 5000
Table of Contents
ADAM 5000 Driver Configuration Manual
1
1.
2
ADAM 5000 Configuration
1.1
1.2
2.
ADAM 5000 ........................................................................................ 2
Module Settings .................................................................................. 3
WebAccess Configuration
2.1
2.2
2.3
2.4
2.5
2.6
4
Port ..................................................................................................... 4
2.1.1
Check the port number .......................................................... 4
2.1.2
WebAccess Comport Page ................................................... 6
2.1.3
Comport Number ................................................................... 6
2.1.4
Description ............................................................................. 6
2.1.5
Baud Rate .............................................................................. 7
2.1.6
Data Bits ................................................................................ 7
2.1.7
Stop Bits ................................................................................ 7
2.1.8
Parity...................................................................................... 7
2.1.9
Scan Time ............................................................................. 7
2.1.10
Timeout .................................................................................. 7
2.1.11
Retry Count ........................................................................... 7
2.1.12
Auto Recover Time ................................................................ 8
2.1.13
Hand Shake RTS................................................................... 8
2.1.14
Hand Shake DTR .................................................................. 8
2.1.15
Backup Port ........................................................................... 9
Device ................................................................................................. 9
2.2.1
Unit Number .......................................................................... 9
Block ................................................................................................... 9
2.3.1
Block Type ........................................................................... 10
2.3.2
Offset ................................................................................... 10
Tag.................................................................................................... 10
2.4.1
Parameter ............................................................................ 11
2.4.2
Address ............................................................................... 11
2.4.3
Scaling Type ........................................................................ 11
Supported Block List ......................................................................... 11
2.5.1
A5013RTD ........................................................................... 11
2.5.2
A5017 .................................................................................. 13
2.5.3
A5017H ................................................................................ 17
2.5.4
A5018 .................................................................................. 21
2.5.5
A5024 .................................................................................. 26
2.5.6
A5051 .................................................................................. 27
2.5.7
A5056 .................................................................................. 28
2.5.8
A5080 .................................................................................. 28
Main Parameter List ......................................................................... 31
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 1-1
WebAccess Configuration Manual
ADAM 5000
1. ADAM 5000 Configuration
1.1
ADAM 5000
The ADAM-5000 Distributed I/O Systems from Advantech are supported by
the ADAM5K Device Type drivers in WebAccess.
The ADAM5K Device driver reads the IO Modules of the ADAM-5000 directly.
The modules contain a RS-485 port. It only has the data+ and dataconnectors. If you want to connect it to an RS-232 port on your computer
please use a converter. The ADAM 4520 is a RS-422/485 to RS-232 converter
module.
Note that when you use a converter the baud rate of the converter must be
set to 9600bps and the handshaking of the converter should match the
handshaking setting on your computer.
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 2
WebAccess Configuration Manual
1.2
ADAM 5000
Module Settings
Start your module while linking the init connector to the ground (to enable
the initial mode) and connect it to the computer.
On the computer start the Adam/Apax .NET Utility
The module will automatically appear in the left tree under the serial port it is
connected to.
If you are using virtual com port from (EKI serial server) or USB to serial
adapters you need to refresh the com port list first and then the module list.
The * next to the module name means it is in initial mode. Make sure that the
protocol is Advantech and note the Address, baud rate and checksum as they
will be required in WebAccess settings.
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 3
WebAccess Configuration Manual
ADAM 5000
Then close the utility and restart the module.
2. WebAccess Configuration
2.1
Port
The ADAM5K protocol uses a serial port. Even if you use a serial port server
or a USB to serial converter the apparent port in your computer (and
therefore the port to select in WebAccess) is a serial port.
2.1.1
Check the port number
If you are using a comport emulator and you do not know the port number
then open the “Start Menu” and right click on “Computer” and select
“Manage”
In the device manager section you can see the list of COM ports on your
computer and recognize the virtual port by its driver name
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 4
WebAccess Configuration Manual
Version 7.0 rev 0a
ADAM 5000
Advantech Corp., Ltd.
page 5
WebAccess Configuration Manual
2.1.2
ADAM 5000
WebAccess Comport Page
Open your WebAccess Configuration and select the SCADA node you want to
add the device to. Then select “Add a new Comport”
All the settings in this page must match the settings in all the modules
attached to the port. So all the modules attached to the same comport must
have the same settings.
2.1.3 Comport Number
The Serial Comport requires the comport number to match that of the
physical interface (e.g. COM1, COM2, COM3, etc) on the SCADA Node.
2.1.4 Description
This is an optional field used for user reference.
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 6
WebAccess Configuration Manual
ADAM 5000
2.1.5 Baud Rate
For the Adam 5K modules the typical baud rate is 9600.
This must match the baud rate configured in the module and the eventual RS485 to RS-232 converter.
2.1.6 Data Bits
The packets can have 7 or 8 Data Bits. The typical setting for Adam 5K is 8
bits.
2.1.7 Stop Bits
The packets can have 1 or 2 Stop Bits. The typical setting for Adam 5K is 1
Stop bit.
2.1.8 Parity
The Parity can be None, Odd, Even or Disabled. The typical setting for Adam
5K is Parity = None.
2.1.9 Scan Time
This is the time in milliseconds to scan the Devices. This must match the
ability of the device to respond. A typical scan rate is 1 per second.
If the Device cannot respond as fast as the SCAN Time entered, WebAccess
will scan at a slower rate.
2.1.10 Timeout
With a 1 second scan rate, a typical Time Out = 200 Milliseconds.
Timeout is the time waited before re-sending a communications packet that
did not have a reply.
Timeout specifies how long the software waits for a response to a data
request, specifically to wait for a reply from one packet. A recommended
value is one-fifth the scan rate, longer if the communication device is slow.
Combined with Retry count, Timeout also determines time to consider a
device or port as BAD. Timeout is the time to wait since last communication
packet sent without a reply. Time is in milliseconds. Slow or poor quality
communications require longer timeout. The faster the communications, the
shorter the timeout required. Shorter timeouts result in faster reconnects
after communication failures.
2.1.11 Retry Count
A typical Retry count = 3.
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 7
WebAccess Configuration Manual
ADAM 5000
Number of times to retry communications if no reply is received from a device.
Combined with Timeout, also determines time to consider a device or port as
BAD.
This is the number of times after the first attempt has failed that
communication should be attempted before indicating a failure. (If Retry
count is 3, a total of 4 failed requests have occurred before tags are marked
bad). Specifically, this is how many times to send a single packet after the
field device fails to respond to the first packet. After the retry count is
exceeded, all the tags in the packet are marked with asterisks and the next
packet of requests is sent. A reasonable value is 3 to 5 times. After this
number of tries, the tags in this packet are marked as "fail to respond" (i.e.
asterisks) and are disabled. In reality, increasing the number of retries hides
failures on the part of the field device to respond to a request. Essentially,
increasing the retries gives the field device more chances to reply.
2.1.12 Auto Recover Time
A typical Auto Recover Time = 60 Seconds.
Auto Recover Time is the time to wait before attempting to re-establish
communications with a BAD device or port.
If communications to the PLC is unusually slow due to hardware,
communications or network issues, you might consider increasing this value.
If communications to the PLC or RTU fails frequently, you may want to
decrease this number in order to have WebAccess try to re-establish
communications sooner.
If communications to the PLC, RTU or device Fails (i.e. exceeds Timeout)
WebAccess will wait the Auto Recover Time before trying to re-establish
communications.
2.1.13 Hand Shake RTS
The typical setting for Adam 5K is HandShakeRts = No.
The RTS (Request To Send) signal is raised and lowered on the Serial
Communications Port if this value set to Yes. RTS is determined by settings
in the field device. Refer to your device interface manual to determine the
value for this field and the type of cable used.
2.1.14 Hand Shake DTR
The typical setting for Adam 5K is HandShakeDtr = No.
The DTR (Data Terminal Ready) signal raised and lowered on the Serial
Communications Port if this value is set to Yes. DTR is determined by settings
in the field device and the type of cable used.
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 8
WebAccess Configuration Manual
ADAM 5000
2.1.15 Backup Port
The Backup Port has not been tested for Adam 5K
2.2
Device
Then Go to the port page and select “Add a new device”. Select the ADAM5K
device Type.
2.2.1
Unit Number
The Unit number must match the “unit number” (or “address”) set in the
module.
2.3
Block
To allow users to add Adam 5K modules easily in WebAccess we created a
block for each module. The block contains all the tags of the module and will
allow an easy access and display.
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 9
WebAccess Configuration Manual
2.3.1
ADAM 5000
Block Type
The block type allows you to select which group of parameters you want to
import (Counter, PID, I/O …).
For Adam 5K select the module type. It will add all the channels and
parameters available in the device. Each Slot contains a different module so
you should add a block for each slot.
2.3.2
Offset
The offset should correspond to the address of the first parameter of the
block. All the other parameters addresses will then be calculated based on the
first one.
In the ADAM4K driver the offset format is: 5017,1,0
The first number should correspond to the device type and the second one to
the slot number; leave the third one to 0.
2.4
Tag
If you do not use all the channels in the device and you want to reduce your
tag count you can add the parameters one by one using “Add tag”.
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 10
WebAccess Configuration Manual
2.4.1
ADAM 5000
Parameter
The parameter gives the type of tag you want to import. Try to select a
parameter as close to the tag type as possible because it will fill the other
option with the default parameters.
In Adam 5K almost all the available tags have been put to the parameter list
so by choosing the correct one all the other fields are set automatically.
2.4.2
Address
For Adam 5K the address starts with the module type (replace 0 by 5017)
followed by the slot number (here 0). The last number should correspond to
the channel number (0 for the AI 0).
2.4.3
Scaling Type
If the data sent by the module is not in a human readable unit you can use
the scaling to change the unit and display a more convenient unit in the node.
In most cases a linear scaling type will be sufficient.
2.5
Supported Block List
There is a block for each ADAM module. The block contain all the possible
parameters in the module. Here are a few of our most used blocks.
2.5.1
A5013RTD
3-ch RTD Input Module
Parameter
Version 7.0 rev 0a
Description
Advantech Corp., Ltd.
page 11
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
A0_H_C
Alarm H Channel Link
A0_H_LMT
High Alarm Limit
A0_H_S
Alarm H Slot Connection
A0_L_C
Alarm L Channel Link
A0_L_LMT
Low Alarm Limit
A0_L_S
Alarm L Slot Connection
A0_H_MOD
High Alarm Mode
A0_H_STS
High Alarm Status
A0_L_MOD
Low Alarm Mode
A0_L_STS
Low Alarm Status
A1_H_C
Alarm H Channel Link
A1_H_LMT
High Alarm Limit
A1_H_S
Alarm H Slot Connection
A1_L_C
Alarm L Channel Link
A1_L_LMT
Low Alarm Limit
A1_L_S
Alarm L Slot Connection
A1_H_MOD
High Alarm Mode
A1_H_STS
High Alarm Status
A1_L_MOD
Low Alarm Mode
A1_L_STS
Low Alarm Status
A2_H_C
Alarm H Channel Link
A2_H_LMT
High Alarm Limit
A2_H_S
Alarm H Slot Connection
A2_L_C
Alarm L Channel Link
A2_L_LMT
Low Alarm Limit
A2_L_S
Alarm L Slot Connection
A2_H_MOD
High Alarm Mode
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 12
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
A2_H_STS
High Alarm Status
A2_L_MOD
Low Alarm Mode
A2_L_STS
Low Alarm Status
AI_0
Analog Input
AI_0_ST
Multiplexing Status
AI_1
Analog Input
AI_1_ST
Multiplexing Status
AI_2
Analog Input
AI_2_ST
Multiplexing Status
AI_FMT
Data Format
AI_INI
Initialize EEPROM
AI_IT
Integration Time
AI_Range
Range
AI_SCL
RTD Self Calibration
AI_SPCL
Span Clibration
AI_ZCL
Zero Calibration
2.5.2
A5017
8-ch Analog Input Module
Parameter
Description
A0_H_C
Alarm H Channel Link
A0_H_LMT
High Alarm Limit
A0_H_S
Alarm H Slot Connection
A0_L_C
Alarm L Channel Link
A0_L_LMT
Low Alarm Limit
A0_L_S
Alarm L Slot Connection
A0_H_MOD
High Alarm Mode
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 13
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
A0_H_STS
High Alarm Status
A0_L_MOD
Low Alarm Mode
A0_L_STS
Low Alarm Status
A1_H_C
Alarm H Channel Link
A1_H_LMT
High Alarm Limit
A1_H_S
Alarm H Slot Connection
A1_L_C
Alarm L Channel Link
A1_L_LMT
Low Alarm Limit
A1_L_S
Alarm L Slot Connection
A1_H_MOD
High Alarm Mode
A1_H_STS
High Alarm Status
A1_L_MOD
Low Alarm Mode
A1_L_STS
Low Alarm Status
A2_H_C
Alarm H Channel Link
A2_H_LMT
High Alarm Limit
A2_H_S
Alarm H Slot Connection
A2_L_C
Alarm L Channel Link
A2_L_LMT
Low Alarm Limit
A2_L_S
Alarm L Slot Connection
A2_H_MOD
High Alarm Mode
A2_H_STS
High Alarm Status
A2_L_MOD
Low Alarm Mode
A2_L_STS
Low Alarm Status
A3_H_C
Alarm H Channel Link
A3_H_LMT
High Alarm Limit
A3_H_S
Alarm H Slot Connection
A3_L_C
Alarm L Channel Link
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 14
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
A3_L_LMT
Low Alarm Limit
A3_L_S
Alarm L Slot Connection
A3_H_MOD
High Alarm Mode
A3_H_STS
High Alarm Status
A3_L_MOD
Low Alarm Mode
A3_L_STS
Low Alarm Status
A4_H_C
Alarm H Channel Link
A4_H_LMT
High Alarm Limit
A4_H_S
Alarm H Slot Connection
A4_L_C
Alarm L Channel Link
A4_L_LMT
Low Alarm Limit
A4_L_S
Alarm L Slot Connection
A4_H_MOD
High Alarm Mode
A4_H_STS
High Alarm Status
A4_L_MOD
Low Alarm Mode
A4_L_STS
Low Alarm Status
A5_H_C
Alarm H Channel Link
A5_H_LMT
High Alarm Limit
A5_H_S
Alarm H Slot Connection
A5_L_C
Alarm L Channel Link
A5_L_LMT
Low Alarm Limit
A5_L_S
Alarm L Slot Connection
A5_H_MOD
High Alarm Mode
A5_H_STS
High Alarm Status
A5_L_MOD
Low Alarm Mode
A5_L_STS
Low Alarm Status
A6_H_C
Alarm H Channel Link
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 15
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
A6_H_LMT
High Alarm Limit
A6_H_S
Alarm H Slot Connection
A6_L_C
Alarm L Channel Link
A6_L_LMT
Low Alarm Limit
A6_L_S
Alarm L Slot Connection
A6_H_MOD
High Alarm Mode
A6_H_STS
High Alarm Status
A6_L_MOD
Low Alarm Mode
A6_L_STS
Low Alarm Status
A7_H_C
Alarm H Channel Link
A7_H_LMT
High Alarm Limit
A7_H_S
Alarm H Slot Connection
A7_L_C
Alarm L Channel Link
A7_L_LMT
Low Alarm Limit
A7_L_S
Alarm L Slot Connection
A7_H_MOD
High Alarm Mode
A7_H_STS
High Alarm Status
A7_L_MOD
Low Alarm Mode
A7_L_STS
Low Alarm Status
AI_0
Analog Input
AI_0_ST
Multiplexing Status
AI_1
Analog Input
AI_1_ST
Multiplexing Status
AI_2
Analog Input
AI_2_ST
Multiplexing Status
AI_3
Analog Input
AI_3_ST
Multiplexing Status
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 16
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
AI_4
Analog Input
AI_4_ST
Multiplexing Status
AI_5
Analog Input
AI_5_ST
Multiplexing Status
AI_6
Analog Input
AI_6_ST
Multiplexing Status
AI_7
Analog Input
AI_7_ST
Multiplexing Status
AI_CJC
AI Cold Junction Compensation
AI_FMT
Data Format
AI_INI
Initialize EEPROM
AI_IT
Integration Time
AI_Range
Range
AI_SCL
RTD Self Calibration
AI_SPCL
Span Clibration
AI_ZCL
Zero Calibration
2.5.3
A5017H
8-channel High-speed Analog Input Module
Parameter
Description
A0_H_C
Alarm H Channel Link
A0_H_LMT
High Alarm Limit
A0_H_S
Alarm H Slot Connection
A0_L_C
Alarm L Channel Link
A0_L_LMT
Low Alarm Limit
A0_L_S
Alarm L Slot Connection
A0_H_MOD
High Alarm Mode
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 17
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
A0_H_STS
High Alarm Status
A0_L_MOD
Low Alarm Mode
A0_L_STS
Low Alarm Status
A1_H_C
Alarm H Channel Link
A1_H_LMT
High Alarm Limit
A1_H_S
Alarm H Slot Connection
A1_L_C
Alarm L Channel Link
A1_L_LMT
Low Alarm Limit
A1_L_S
Alarm L Slot Connection
A1_H_MOD
High Alarm Mode
A1_H_STS
High Alarm Status
A1_L_MOD
Low Alarm Mode
A1_L_STS
Low Alarm Status
A2_H_C
Alarm H Channel Link
A2_H_LMT
High Alarm Limit
A2_H_S
Alarm H Slot Connection
A2_L_C
Alarm L Channel Link
A2_L_LMT
Low Alarm Limit
A2_L_S
Alarm L Slot Connection
A2_H_MOD
High Alarm Mode
A2_H_STS
High Alarm Status
A2_L_MOD
Low Alarm Mode
A2_L_STS
Low Alarm Status
A3_H_C
Alarm H Channel Link
A3_H_LMT
High Alarm Limit
A3_H_S
Alarm H Slot Connection
A3_L_C
Alarm L Channel Link
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 18
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
A3_L_LMT
Low Alarm Limit
A3_L_S
Alarm L Slot Connection
A3_H_MOD
High Alarm Mode
A3_H_STS
High Alarm Status
A3_L_MOD
Low Alarm Mode
A3_L_STS
Low Alarm Status
A4_H_C
Alarm H Channel Link
A4_H_LMT
High Alarm Limit
A4_H_S
Alarm H Slot Connection
A4_L_C
Alarm L Channel Link
A4_L_LMT
Low Alarm Limit
A4_L_S
Alarm L Slot Connection
A4_H_MOD
High Alarm Mode
A4_H_STS
High Alarm Status
A4_L_MOD
Low Alarm Mode
A4_L_STS
Low Alarm Status
A5_H_C
Alarm H Channel Link
A5_H_LMT
High Alarm Limit
A5_H_S
Alarm H Slot Connection
A5_L_C
Alarm L Channel Link
A5_L_LMT
Low Alarm Limit
A5_L_S
Alarm L Slot Connection
A5_H_MOD
High Alarm Mode
A5_H_STS
High Alarm Status
A5_L_MOD
Low Alarm Mode
A5_L_STS
Low Alarm Status
A6_H_C
Alarm H Channel Link
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 19
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
A6_H_LMT
High Alarm Limit
A6_H_S
Alarm H Slot Connection
A6_L_C
Alarm L Channel Link
A6_L_LMT
Low Alarm Limit
A6_L_S
Alarm L Slot Connection
A6_H_MOD
High Alarm Mode
A6_H_STS
High Alarm Status
A6_L_MOD
Low Alarm Mode
A6_L_STS
Low Alarm Status
A7_H_C
Alarm H Channel Link
A7_H_LMT
High Alarm Limit
A7_H_S
Alarm H Slot Connection
A7_L_C
Alarm L Channel Link
A7_L_LMT
Low Alarm Limit
A7_L_S
Alarm L Slot Connection
A7_H_MOD
High Alarm Mode
A7_H_STS
High Alarm Status
A7_L_MOD
Low Alarm Mode
A7_L_STS
Low Alarm Status
AI_0
Analog Input
AI_0_R
Range
AI_0_ST
Multiplexing Status
AI_1
Analog Input
AI_1_R
Range
AI_1_ST
Multiplexing Status
AI_2
Analog Input
AI_2_R
Range
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 20
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
AI_2_ST
Multiplexing Status
AI_3
Analog Input
AI_3_R
Range
AI_3_ST
Multiplexing Status
AI_4
Analog Input
AI_4_R
Range
AI_4_ST
Multiplexing Status
AI_5
Analog Input
AI_5_R
Range
AI_5_ST
Multiplexing Status
AI_6
Analog Input
AI_6_R
Range
AI_6_ST
Multiplexing Status
AI_7
Analog Input
AI_7_R
Range
AI_7_ST
Multiplexing Status
AI_INI
Initialize EEPROM
AI_SPCL
Span Clibration
AI_ZCL
Zero Calibration
2.5.4
A5018
7-ch Thermocouple Input Module
Parameter
Description
A0_H_C
Alarm H Channel Link
A0_H_LMT
High Alarm Limit
A0_H_S
Alarm H Slot Connection
A0_L_C
Alarm L Channel Link
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 21
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
A0_L_LMT
Low Alarm Limit
A0_L_S
Alarm L Slot Connection
A0_H_MOD
High Alarm Mode
A0_H_STS
High Alarm Status
A0_L_MOD
Low Alarm Mode
A0_L_STS
Low Alarm Status
A1_H_C
Alarm H Channel Link
A1_H_LMT
High Alarm Limit
A1_H_S
Alarm H Slot Connection
A1_L_C
Alarm L Channel Link
A1_L_LMT
Low Alarm Limit
A1_L_S
Alarm L Slot Connection
A1_H_MOD
High Alarm Mode
A1_H_STS
High Alarm Status
A1_L_MOD
Low Alarm Mode
A1_L_STS
Low Alarm Status
A2_H_C
Alarm H Channel Link
A2_H_LMT
High Alarm Limit
A2_H_S
Alarm H Slot Connection
A2_L_C
Alarm L Channel Link
A2_L_LMT
Low Alarm Limit
A2_L_S
Alarm L Slot Connection
A2_H_MOD
High Alarm Mode
A2_H_STS
High Alarm Status
A2_L_MOD
Low Alarm Mode
A2_L_STS
Low Alarm Status
A3_H_C
Alarm H Channel Link
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 22
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
A3_H_LMT
High Alarm Limit
A3_H_S
Alarm H Slot Connection
A3_L_C
Alarm L Channel Link
A3_L_LMT
Low Alarm Limit
A3_L_S
Alarm L Slot Connection
A3_H_MOD
High Alarm Mode
A3_H_STS
High Alarm Status
A3_L_MOD
Low Alarm Mode
A3_L_STS
Low Alarm Status
A4_H_C
Alarm H Channel Link
A4_H_LMT
High Alarm Limit
A4_H_S
Alarm H Slot Connection
A4_L_C
Alarm L Channel Link
A4_L_LMT
Low Alarm Limit
A4_L_S
Alarm L Slot Connection
A4_H_MOD
High Alarm Mode
A4_H_STS
High Alarm Status
A4_L_MOD
Low Alarm Mode
A4_L_STS
Low Alarm Status
A5_H_C
Alarm H Channel Link
A5_H_LMT
High Alarm Limit
A5_H_S
Alarm H Slot Connection
A5_L_C
Alarm L Channel Link
A5_L_LMT
Low Alarm Limit
A5_L_S
Alarm L Slot Connection
A5_H_MOD
High Alarm Mode
A5_H_STS
High Alarm Status
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 23
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
A5_L_MOD
Low Alarm Mode
A5_L_STS
Low Alarm Status
A6_H_C
Alarm H Channel Link
A6_H_LMT
High Alarm Limit
A6_H_S
Alarm H Slot Connection
A6_L_C
Alarm L Channel Link
A6_L_LMT
Low Alarm Limit
A6_L_S
Alarm L Slot Connection
A6_H_MOD
High Alarm Mode
A6_H_STS
High Alarm Status
A6_L_MOD
Low Alarm Mode
A6_L_STS
Low Alarm Status
A7_H_C
Alarm H Channel Link
A7_H_LMT
High Alarm Limit
A7_H_S
Alarm H Slot Connection
A7_L_C
Alarm L Channel Link
A7_L_LMT
Low Alarm Limit
A7_L_S
Alarm L Slot Connection
A7_H_MOD
High Alarm Mode
A7_H_STS
High Alarm Status
A7_L_MOD
Low Alarm Mode
A7_L_STS
Low Alarm Status
AI_0
Analog Input
AI_0_CJC
Cold Junc. Comp.
AI_0_R
Range
AI_0_ST
Multiplexing Status
AI_1
Analog Input
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 24
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
AI_1_CJC
Cold Junc. Comp.
AI_1_R
Range
AI_1_ST
Multiplexing Status
AI_2
Analog Input
AI_2_CJC
Cold Junc. Comp.
AI_2_R
Range
AI_2_ST
Multiplexing Status
AI_3
Analog Input
AI_3_CJC
Cold Junc. Comp.
AI_3_R
Range
AI_3_ST
Multiplexing Status
AI_4
Analog Input
AI_4_CJC
Cold Junc. Comp.
AI_4_R
Range
AI_4_ST
Multiplexing Status
AI_5
Analog Input
AI_5_CJC
Cold Junc. Comp.
AI_5_R
Range
AI_5_ST
Multiplexing Status
AI_6
Analog Input
AI_6_CJC
Cold Junc. Comp.
AI_6_R
Range
AI_6_ST
Multiplexing Status
AI_7
Analog Input
AI_7_CJC
Cold Junc. Comp.
AI_7_R
Range
AI_7_ST
Multiplexing Status
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 25
WebAccess Configuration Manual
2.5.5
ADAM 5000
A5024
4-ch Analog Output Module
Parameter
Description
AO_0
Analog Output
AO_0_SLW
Slew Rate
AO_0_TCL
Trim Calibration
AO_0_20C
20mA Calibration
AO_0_4CL
4mA Calibration
AO_0_FMT
Data Format
AO_0_R
Range
AO_0_ST
Set Startup Value
AO_1
Analog Output
AO_1_SLW
Slew Rate
AO_1_TCL
Trim Calibration
AO_1_20C
20mA Calibration
AO_1_4CL
4mA Calibration
AO_1_FMT
Data Format
AO_1_R
Range
AO_1_ST
Set Startup Value
AO_2
Analog Output
AO_2_SLW
Slew Rate
AO_2_TCL
Trim Calibration
AO_2_20C
20mA Calibration
AO_2_4CL
4mA Calibration
AO_2_FMT
Data Format
AO_2_R
Range
AO_2_ST
Set Startup Value
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 26
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
AO_3
Analog Output
AO_3_SLW
Slew Rate
AO_3_TCL
Trim Calibration
AO_3_20C
20mA Calibration
AO_3_4CL
4mA Calibration
AO_3_FMT
Data Format
AO_3_R
Range
AO_3_ST
Set Startup Value
2.5.6
A5051
16-ch Digital Input Module
Parameter
Description
DI_00
Digital Input
DI_01
Digital Input
DI_02
Digital Input
DI_03
Digital Input
DI_04
Digital Input
DI_05
Digital Input
DI_06
Digital Input
DI_07
Digital Input
DI_08
Digital Input
DI_09
Digital Input
DI_10
Digital Input
DI_11
Digital Input
DI_12
Digital Input
DI_13
Digital Input
DI_14
Digital Input
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 27
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
DI_15
Digital Input
2.5.7
A5056
16-ch Digital Output Module
Parameter
Description
DO_00M
Masking Status
DO_01M
Masking Status
DO_02M
Masking Status
DO_03M
Masking Status
DO_04M
Masking Status
DO_05M
Masking Status
DO_06M
Masking Status
DO_07M
Masking Status
DO_08M
Masking Status
DO_09M
Masking Status
DO_10M
Masking Status
DO_11M
Masking Status
DO_12M
Masking Status
DO_13M
Masking Status
DO_14M
Masking Status
DO_15M
Masking Status
2.5.8
A5080
4-ch Counter/Frequency Module
Parameter
Description
A0_H_C
Alarm H Channel Link
A0_H_LMT
High Alarm Limit
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 28
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
A0_H_S
Alarm H Slot Connection
A0_L_C
Alarm L Channel Link
A0_L_LMT
Low Alarm Limit
A0_L_S
Alarm L Slot Connection
A0_H_MOD
High Alarm Mode
A0_H_STS
High Alarm Status
A0_L_MOD
Low Alarm Mode
A0_L_STS
Low Alarm Status
A1_H_C
Alarm H Channel Link
A1_H_LMT
High Alarm Limit
A1_H_S
Alarm H Slot Connection
A1_L_C
Alarm L Channel Link
A1_L_LMT
Low Alarm Limit
A1_L_S
Alarm L Slot Connection
A1_H_MOD
High Alarm Mode
A1_H_STS
High Alarm Status
A1_L_MOD
Low Alarm Mode
A1_L_STS
Low Alarm Status
A2_H_C
Alarm H Channel Link
A2_H_LMT
High Alarm Limit
A2_H_S
Alarm H Slot Connection
A2_L_C
Alarm L Channel Link
A2_L_LMT
Low Alarm Limit
A2_L_S
Alarm L Slot Connection
A2_H_MOD
High Alarm Mode
A2_H_STS
High Alarm Status
A2_L_MOD
Low Alarm Mode
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 29
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
A2_L_STS
Low Alarm Status
A3_H_C
Alarm H Channel Link
A3_H_LMT
High Alarm Limit
A3_H_S
Alarm H Slot Connection
A3_L_C
Alarm L Channel Link
A3_L_LMT
Low Alarm Limit
A3_L_S
Alarm L Slot Connection
A3_H_MOD
High Alarm Mode
A3_H_STS
High Alarm Status
A3_L_MOD
Low Alarm Mode
A3_L_STS
Low Alarm Status
CF_0
Counter Data
CF_0_INI
Counter Initial Value
CF_0_CLR
Clear CF
CF_0_OVR
Overflow Flag
CF_0_ST
Status
CF_1
Counter Data
CF_1_INI
Counter Initial Value
CF_1_CLR
Clear CF
CF_1_OVR
Overflow Flag
CF_1_ST
Status
CF_2
Counter Data
CF_2_INI
Counter Initial Value
CF_2_CLR
Clear CF
CF_2_OVR
Overflow Flag
CF_2_ST
Status
CF_3
Counter Data
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 30
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
CF_3_INI
Counter Initial Value
CF_3_CLR
Clear CF
CF_3_OVR
Overflow Flag
CF_3_ST
Status
CF_FILTER
C/F Filter
CF_FMT
C/F Data Format
CF_MODE
C/F Mode
2.6
Main Parameter List
Parameter
Description
A0_H_C
Alarm H Channel Link
A0_H_LMT
High Alarm Limit
A0_H_S
Alarm H Slot Connection
A0_L_C
Alarm L Channel Link
A0_L_LMT
Low Alarm Limit
A0_L_S
Alarm L Slot Connection
A1_H_C
Alarm H Channel Link
A1_H_LMT
High Alarm Limit
A1_H_S
Alarm H Slot Connection
A1_L_C
Alarm L Channel Link
A1_L_LMT
Low Alarm Limit
A1_L_S
Alarm L Slot Connection
A2_H_C
Alarm H Channel Link
A2_H_LMT
High Alarm Limit
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 31
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
A2_H_S
Alarm H Slot Connection
A2_L_C
Alarm L Channel Link
A2_L_LMT
Low Alarm Limit
A2_L_S
Alarm L Slot Connection
A3_H_C
Alarm H Channel Link
A3_H_LMT
High Alarm Limit
A3_H_S
Alarm H Slot Connection
A3_L_C
Alarm L Channel Link
A3_L_LMT
Low Alarm Limit
A3_L_S
Alarm L Slot Connection
A4_H_C
Alarm H Channel Link
A4_H_LMT
High Alarm Limit
A4_H_S
Alarm H Slot Connection
A4_L_C
Alarm L Channel Link
A4_L_LMT
Low Alarm Limit
A4_L_S
Alarm L Slot Connection
A5_H_C
Alarm H Channel Link
A5_H_LMT
High Alarm Limit
A5_H_S
Alarm H Slot Connection
A5_L_C
Alarm L Channel Link
A5_L_LMT
Low Alarm Limit
A5_L_S
Alarm L Slot Connection
A6_H_C
Alarm H Channel Link
A6_H_LMT
High Alarm Limit
A6_H_S
Alarm H Slot Connection
A6_L_C
Alarm L Channel Link
A6_L_LMT
Low Alarm Limit
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 32
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
A6_L_S
Alarm L Slot Connection
A7_H_C
Alarm H Channel Link
A7_H_LMT
High Alarm Limit
A7_H_S
Alarm H Slot Connection
A7_L_C
Alarm L Channel Link
A7_L_LMT
Low Alarm Limit
A7_L_S
Alarm L Slot Connection
AI_0
Analog Input
AI_0_CJC
Cold Junc. Comp.
AI_0_R
Range
AI_1
Analog Input
AI_1_CJC
Cold Junc. Comp.
AI_1_R
Range
AI_2
Analog Input
AI_2_CJC
Cold Junc. Comp.
AI_2_R
Range
AI_3
Analog Input
AI_3_CJC
Cold Junc. Comp.
AI_3_R
Range
AI_4
Analog Input
AI_4_CJC
Cold Junc. Comp.
AI_4_R
Range
AI_5
Analog Input
AI_5_CJC
Cold Junc. Comp.
AI_5_R
Range
AI_6
Analog Input
AI_6_CJC
Cold Junc. Comp.
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 33
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
AI_6_R
Range
AI_7
Analog Input
AI_7_CJC
Cold Junc. Comp.
AI_7_R
Range
AI_CJC
AI Cold Junction Compensation
AI_RANGE
AI Range
AO_0
Analog Output
AO_0_SLW
Slew Rate
AO_0_TCL
Trim Calibration
AO_1
Analog Output
AO_1_SLW
Slew Rate
AO_1_TCL
Trim Calibration
AO_2
Analog Output
AO_2_SLW
Slew Rate
AO_2_TCL
Trim Calibration
AO_3
Analog Output
AO_3_SLW
Slew Rate
AO_3_TCL
Trim Calibration
CF_0
Counter Data
CF_0_INI
Counter Initial Value
CF_1
Counter Data
CF_1_INI
Counter Initial Value
CF_2
Counter Data
CF_2_INI
Counter Initial Value
CF_3
Counter Data
CF_3_INI
Counter Initial Value
CF_FILTER
Counter Filter
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 34
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
A0_H_MOD
High Alarm Mode
A0_H_STS
High Alarm Status
A0_L_MOD
Low Alarm Mode
A0_L_STS
Low Alarm Status
A1_H_MOD
High Alarm Mode
A1_H_STS
High Alarm Status
A1_L_MOD
Low Alarm Mode
A1_L_STS
Low Alarm Status
A2_H_MOD
High Alarm Mode
A2_H_STS
High Alarm Status
A2_L_MOD
Low Alarm Mode
A2_L_STS
Low Alarm Status
A3_H_MOD
High Alarm Mode
A3_H_STS
High Alarm Status
A3_L_MOD
Low Alarm Mode
A3_L_STS
Low Alarm Status
A4_H_MOD
High Alarm Mode
A4_H_STS
High Alarm Status
A4_L_MOD
Low Alarm Mode
A4_L_STS
Low Alarm Status
A5_H_MOD
High Alarm Mode
A5_H_STS
High Alarm Status
A5_L_MOD
Low Alarm Mode
A5_L_STS
Low Alarm Status
A6_H_MOD
High Alarm Mode
A6_H_STS
High Alarm Status
A6_L_MOD
Low Alarm Mode
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 35
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
A6_L_STS
Low Alarm Status
A7_H_MOD
High Alarm Mode
A7_H_STS
High Alarm Status
A7_L_MOD
Low Alarm Mode
A7_L_STS
Low Alarm Status
AI_0_FMT
Data Format
AI_0_INI
Initialize EEPROM
AI_0_IT
Integration Time
AI_0_SCL
Span Calibration
AI_0_ST
Multiplexing Status
AI_0_ZCL
Zero Calibration
AI_1_FMT
Data Format
AI_1_INI
Initialize EEPROM
AI_1_IT
Integration Time
AI_1_SCL
Span Calibration
AI_1_ST
Multiplexing Status
AI_1_ZCL
Zero Calibration
AI_2_FMT
Data Format
AI_2_INI
Initialize EEPROM
AI_2_IT
Integration Time
AI_2_SCL
Span Calibration
AI_2_ST
Multiplexing Status
AI_2_ZCL
Zero Calibration
AI_3_FMT
Data Format
AI_3_INI
Initialize EEPROM
AI_3_IT
Integration Time
AI_3_SCL
Span Calibration
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 36
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
AI_3_ST
Multiplexing Status
AI_3_ZCL
Zero Calibration
AI_4_FMT
Data Format
AI_4_INI
Initialize EEPROM
AI_4_IT
Integration Time
AI_4_SCL
Span Calibration
AI_4_ST
Multiplexing Status
AI_4_ZCL
Zero Calibration
AI_5_FMT
Data Format
AI_5_INI
Initialize EEPROM
AI_5_IT
Integration Time
AI_5_SCL
Span Calibration
AI_5_ST
Multiplexing Status
AI_5_ZCL
Zero Calibration
AI_6_FMT
Data Format
AI_6_INI
Initialize EEPROM
AI_6_IT
Integration Time
AI_6_SCL
Span Calibration
AI_6_ST
Multiplexing Status
AI_6_ZCL
Zero Calibration
AI_7_FMT
Data Format
AI_7_INI
Initialize EEPROM
AI_7_IT
Integration Time
AI_7_SCL
Span Calibration
AI_7_ST
Multiplexing Status
AI_7_ZCL
Zero Calibration
AI_FMT
Data Format
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 37
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
AI_INI
Initialize EEPROM
AI_IT
Integration Time
AI_SCL
RTD Self Calibration
AI_SPCL
Span Clibration
AI_ZCL
Zero Calibration
AO_0_20C
20mA Calibration
AO_0_4CL
4mA Calibration
AO_0_FMT
Data Format
AO_0_R
Range
AO_0_ST
Set Startup Value
AO_1_20C
20mA Calibration
AO_1_4CL
4mA Calibration
AO_1_FMT
Data Format
AO_1_R
Range
AO_1_ST
Set Startup Value
AO_2_20C
20mA Calibration
AO_2_4CL
4mA Calibration
AO_2_FMT
Data Format
AO_2_R
Range
AO_2_ST
Set Startup Value
AO_3_20C
20mA Calibration
AO_3_4CL
4mA Calibration
AO_3_FMT
Data Format
AO_3_R
Range
AO_3_ST
Set Startup Value
CF_0_CLR
Clear CF
CF_0_OVR
Overflow Flag
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 38
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
CF_0_ST
Status
CF_1_CLR
Clear CF
CF_1_OVR
Overflow Flag
CF_1_ST
Status
CF_2_CLR
Clear CF
CF_2_OVR
Overflow Flag
CF_2_ST
Status
CF_3_CLR
Clear CF
CF_3_OVR
Overflow Flag
CF_3_ST
Status
CF_FMT
C/F Data Format
CF_MODE
C/F Mode
DI_00
Digital Input
DI_01
Digital Input
DI_02
Digital Input
DI_03
Digital Input
DI_04
Digital Input
DI_05
Digital Input
DI_06
Digital Input
DI_07
Digital Input
DI_08
Digital Input
DI_09
Digital Input
DI_10
Digital Input
DI_11
Digital Input
DI_12
Digital Input
DI_13
Digital Input
DI_14
Digital Input
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 39
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
DI_15
Digital Input
DO_00
Digital Output
DO_01
Digital Output
DO_02
Digital Output
DO_03
Digital Output
DO_04
Digital Output
DO_05
Digital Output
DO_06
Digital Output
DO_07
Digital Output
DO_08
Digital Output
DO_09
Digital Output
DO_10
Digital Output
DO_11
Digital Output
DO_12
Digital Output
DO_13
Digital Output
DO_14
Digital Output
DO_15
Digital Output
DO_00M
Masking Status
DO_01M
Masking Status
DO_02M
Masking Status
DO_03M
Masking Status
DO_04M
Masking Status
DO_05M
Masking Status
DO_06M
Masking Status
DO_07M
Masking Status
DO_08M
Masking Status
DO_09M
Masking Status
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 40
WebAccess Configuration Manual
ADAM 5000
Parameter
Description
DO_10M
Masking Status
DO_11M
Masking Status
DO_12M
Masking Status
DO_13M
Masking Status
DO_14M
Masking Status
DO_15M
Masking Status
Version 7.0 rev 0a
Advantech Corp., Ltd.
page 41