Vista 10SE Keypad/Console Command Summary Command / Function Name Entering Program Mode Syntax Arming Away Installer Code + 8 + 0 (default = 4111) Code + 2 Arming Stay Code + 3 Arming Instant Code + 7 Arming Maximum Code + 4 Disarming Code + 1 Bypass Code + 6 + Zone # Comments/Notes If this does not work then power down & up then hit * + # simultaneously within 50 seconds. This arming mode gives you exit & entry delays & arms perimeter & interior zones. This arming mode gives you exit & entry delays & arms perimeter zones. This arming mode gives you exit & no entry delay & arms perimeter zones. This arming mode gives you exit but no entry delay & arms perimeter & interior zones. Always Enabled Quick Forced Bypass Code + 6 (wait 2 seconds) If enabled in field *23 Chime Mode Code + 9 Chimes on perimeter & entry/exit zones Site-initiated download Code + # +1 Calls modem at offsite computer System Test Code + 5 Code + 1 exits Transmitter ID Sniffer Mode Code + # + 3 Go/No Go Test Mode Code + # + 4 Displays all numbers, which disappear when transmision is received, to exit hit code + 1 Puts receiver in ½ gain mode, to exit hit code + 1 House ID Sniffer Mode Code + # + 2 Adding User Codes Master code + 8 + user 2-6 + new code Master code + 8 + 8 + Duress code Installer Code + 8 + 2 + New Code Master code + 8 + 2 + new code + new code Adding Duress Code Adding a Master Code Changing master code Allows you to check the house ID on wireless devices.