Download: Coriolis Mass Flow Meter Application Questionnaire

Industry
SITRANS F C Coriolis MASSFLO Flow Meter Application Data Sheet
Email To: [email protected] or FAX TO: 972-522-4503
Instructions: Navigate through the form using the TAB key or mouse. To select a checkbox, click with mouse or press the SPACEBAR. To select units,
click and choose from drop-down menu.
Requestor Information
Customer Information
End-User Information
Company Name:
Company Name:
Company Name:
Requestor Name:
City:
City:
Phone:
State:
State:
E-mail:
Country:
Country:
Selected Part Number(s) For This Application
Process Information For Process Fluid
Fluid Name / Description:
(Liquid or Gas)
Amount of Solids:
Min:
Process Temperature Range:
Pressure @ zero flow:
PSIG
Particle Size:
(If Known)
% (If Applicable)
Operating:
BAR
Max:
Pressure @ operating flow:
PSIG
BAR
(Unit)
ºF
ºC
Max. Pressure
Drop Allowable:
PSIG
BAR
Density of Fluid in Weight (mass) Unit of Measure:
(e.g. 230 Kg/m3, 19.5 Lbs/gallon, 0.89 SG, etc)
Viscosity of Fluid:
per
cP OR cSt (circle one)
Fluid pH:
(If Known)
Process Application
Tag #:
Flow Rate Unit:
Flow Rate Amount:
Minimum:
The Flow Is:
Flow Rate Time Unit, per:
Nominal:
Single Direction
Bi-Directional
Second
Maximum:
Continuous
Pulsing
If Pulsing, Describe On/Off Times or Batch Size:
Time on:
Time off:
Batch Size:
Installation
Pipe Material / Schedule:
Nominal Process Pipe Diameter:
Connection:
Flanged
in
NPT
mm
Hygenic (TriClamp or TriClover)
Size Desired:
© Siemens Industry, Inc.
Rev. MAY 2012
Minute
Hour
Day
Industry
Sensor Location
Flow Sensor Located:
Indoors
Outdoors
Area and Agency Rating:
General Purpose
Hazardous Area:
FM/CSA:
Sensor Location With Respect To Transmitter:
Pipe Orientation:
Horizontal
Class:
Integral
Vertical
Direction Of Flow For Vertical / Inclined:
Div:
No
Protection Group:
Other:
Remotely Mounted; Distance:
Inclined
Up
Yes
Full Pipe:
Yes
No
Intermittent
Down
Sensor Data
Calibration Required:
Factory Standard
Sensor Material:
316 Stainless Steel
Special Density
Brix
Fraction
%
(A) in
%
(B)
Hastelloy C
Length Required From Transmitter To Flow Sensor:
Ft
Meters
Transmitter
Will flow transmitter be in a hazardous area?
Area and Agency Rating:
Temperature @ Flow Transmitter:
NEMA 4X (IP67)
Yes
General Purpose
Min:
No
Power:
FM/CSA: Class
Typ:
Max:
Div.
ºF
18-30 VDC / 20-30 VAC
Protection Group:
Other:
ºC
DIN Rail Mounted, FC070
Rack-Mounted (NEMA 2 / 4X)
87-253 VAC
Outputs required:
FC070 Ex Version
Communications:
Current / Analog 4-20 mA
Digital Pulse
Modbus
HART
Foundation Fieldbus
Relay (Low power)
Digital Frequency
Profibus DP
Profibus PA
DeviceNet
Calibration Accuracy
Accuracy Required:
+/-
0.1%
Other :
(specify)
Disclaimer
The information contained in this data sheet is believed to be accurate however we do not assume any responsibility for errors or any
liability arising from the application or use of any product herein. This data sheet neither states nor implies warranty of any kind,
including fitness for any particular application.
© Siemens Industry, Inc.
Rev. MAY 2012
Industry
Insert a photo or a sketch of the application if available. Simply copy and paste into this table. Bitmaps should be no larger than 640 X 480
© Siemens Industry, Inc.
Rev. MAY 2012