Download

New Product
Switch Mode Power Supply
S8EX (15, 30, 50, 100, 150, and 240-W Models)
Newly Released High-capacity 240-W Models in S8EX-series Lineup
Rated Output of 300 W for 200 VAC.*
* From 170 to 264 VAC.
New 240-W Models
• Lineup of models with 24-, 36-, and 48-VDC output
voltages.
15-W, 35-W, 50-W, 100-W, and 150-W Models
• Lineup of models with from 5 to 48-VDC output
voltages.
All Models
• Approved standards:
UL60950-1, cUR CSA C22.2 No. 60950-1, EN 50178,
and EN 60950-1
• Lineup includes open-frame models, models with
chassis, and models with chassis and covers.
• Wide-range power supply: 100 to 240 VAC
• Complies with harmonic current standard in EN
61000-3-2 (50-W to 240-W models).
• The top class in industry for compact size.
• Boost current output (some models excluded).
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Refer to Safety Precautions on page 22.
Model Number Structure
Model Number Legend
Note: Not all combinations are possible. Refer to List of Models in Ordering Information on page 2.
S8EX-@@@@@@@@-@@@-@@
1 2
3
4 5
6
1. Power Boost Function
Blank: None
B: Power boost for output current
7 8
2. Power Factor Improvement Function
N: None
P: Power factor improvement function provided *
* Harmonic current standard: EN 61000-3-2 compliant.
3. Power Ratings
015: 15 W
030: 30 W
050: 50 W
100: 100 W
150: 150 W
240: 240 W
4. Output Voltage
05: 5 V
12: 12 V
15: 15 V
24: 24 V
36: 36 V
48: 48 V
5. Configuration
None: Open-frame
L: With chassis
LC: With chassis and cover
6. Option 1
None: Standard model
CN1: XH connector (manufactured by J.S.T. Mfg. Co., Ltd.) *
* This option is applicable only for 15-W models.
7. Option 2
None: Standard model
R: Remote control *
* This option is applicable only for 50-W, 100-W, 150-W, and
240-W models.
* This option is applicable only for open-frame models.
8. Option 3
None: Standard model
C: Coating (one side) *
* This option is applicable only for open-frame models.
1
S8EX
Ordering Information
List of Models
Note: For details on normal stock models, contact your nearest OMRON representative.
Open frame
Power ratings
15 W
30 W
50 W
100 W
150 W
Output voltage
5V
12 V
15 V
24 V
48 V
5V
12 V
15 V
24 V
48 V
5V
12 V
24 V
48 V
5V
12 V
24 V
48 V
5V
12 V
24 V
48 V
24 V
240 W
36 V
48 V
Output current
3A
1.3 A
1A
0.7 A
0.32 A
6A
2.5 A
2A
1.3 A
0.65 A
10 A
4.3 A
2.1 A
1.1 A
20 A
8.5 A
4.3 A
2.1 A
30 A
12.5 A
6.3 A
3.2 A
10 A (100 VAC)
12.5 A (200 VAC)
6.7 A (100 VAC)
8.4 A (200 VAC)
5 A (100 VAC)
6.3 A (200 VAC)
Note: The input voltage is 100 to 240 VAC for all models.
2
Boost current
15 A
6.5 A
4.2 A
2.2 A
--12.8 A
8.6 A
4.2 A
--18.8 A
12.6 A
6.4 A
Model
S8EX-N01505
S8EX-N01512
S8EX-N01515
S8EX-N01524
S8EX-N01548
S8EX-N03005
S8EX-N03012
S8EX-N03015
S8EX-N03024
S8EX-N03048
S8EX-BP05005
S8EX-BP05012
S8EX-BP05024
S8EX-BP05048
S8EX-P10005
S8EX-BP10012
S8EX-BP10024
S8EX-BP10048
S8EX-P15005
S8EX-BP15012
S8EX-BP15024
S8EX-BP15048
20 A
S8EX-BP24024
13.4 A
S8EX-BP24036
10 A
S8EX-BP24048
---
---
S8EX
With chassis
Power ratings
15 W
30 W
50 W
100 W
150 W
Output voltage
5V
12 V
15 V
24 V
48 V
5V
12 V
15 V
24 V
48 V
5V
12 V
24 V
48 V
5V
12 V
24 V
48 V
5V
12 V
24 V
48 V
24 V
240 W
36 V
48 V
Output current
3A
1.3 A
1A
0.7 A
0.32 A
6A
2.5 A
2A
1.3 A
0.65 A
10 A
4.3 A
2.1 A
1.1 A
20 A
8.5 A
4.3 A
2.1 A
30 A
12.5 A
6.3 A
3.2 A
10 A (100 VAC)
12.5 A (200 VAC)
6.7 A (100 VAC)
8.4 A (200 VAC)
5 A (100 VAC)
6.3 A (200 VAC)
Boost current
15 A
6.5 A
4.2 A
2.2 A
--12.8 A
8.6 A
4.2 A
--18.8 A
12.6 A
6.4 A
Model
S8EX-N01505L
S8EX-N01512L
S8EX-N01515L
S8EX-N01524L
S8EX-N01548L
S8EX-N03005L
S8EX-N03012L
S8EX-N03015L
S8EX-N03024L
S8EX-N03048L
S8EX-BP05005L
S8EX-BP05012L
S8EX-BP05024L
S8EX-BP05048L
S8EX-P10005L
S8EX-BP10012L
S8EX-BP10024L
S8EX-BP10048L
S8EX-P15005L
S8EX-BP15012L
S8EX-BP15024L
S8EX-BP15048L
20 A
S8EX-BP24024L
13.4 A
S8EX-BP24036L
10 A
S8EX-BP24048L
---
---
Note: The input voltage is 100 to 240 VAC for all models.
3
S8EX
With chassis and cover
Power ratings
15 W
30 W
50 W
100 W
150 W
Output voltage
5V
12 V
15 V
24 V
48 V
5V
12 V
15 V
24 V
48 V
5V
12 V
24 V
48 V
5V
12 V
24 V
48 V
5V
12 V
24 V
48 V
24 V
240 W
36 V
48 V
Output current
3A
1.3 A
1A
0.7 A
0.32 A
6A
2.5 A
2A
1.3 A
0.65 A
10 A
4.3 A
2.1 A
1.1 A
20 A
8.5 A
4.3 A
2.1 A
30 A
12.5 A
6.3 A
3.2 A
10 A (100 VAC)
12.5 A (200 VAC)
6.7 A (100 VAC)
8.4 A (200 VAC)
5 A (100 VAC)
6.3 A (200 VAC)
Note: The input voltage is 100 to 240 VAC for all models.
4
Boost current
15 A
6.5 A
4.2 A
2.2 A
--12.8 A
8.6 A
4.2 A
--18.8 A
12.6 A
6.4 A
Model
S8EX-N01505LC
S8EX-N01512LC
S8EX-N01515LC
S8EX-N01524LC
S8EX-N01548LC
S8EX-N03005LC
S8EX-N03012LC
S8EX-N03015LC
S8EX-N03024LC
S8EX-N03048LC
S8EX-BP05005LC
S8EX-BP05012LC
S8EX-BP05024LC
S8EX-BP05048LC
S8EX-P10005LC
S8EX-BP10012LC
S8EX-BP10024LC
S8EX-BP10048LC
S8EX-P15005LC
S8EX-BP15012LC
S8EX-BP15024LC
S8EX-BP15048LC
20 A
S8EX-BP24024LC
13.4 A
S8EX-BP24036LC
10 A
S8EX-BP24048LC
---
---
S8EX
Ratings, Characteristics, and Functions
Power ratings
Item
Efficiency (Typ.)
5V
12 V
15 V
24 V
48 V
100 VAC input
74%
77%
80%
80%
83%
200 VAC input
74%
77%
78%
78%
82%
100 to 240 VAC (allowable voltage: 85 to 264 VAC or 120 to 370 VDC *6)
Voltage *1
Frequency *1
Current (Typ.)
Input
Leakage current
Inrush current (Typ.)
Output
15 W
Output voltage
50/60 Hz (47 to 450 Hz)
100 VAC input
0.4 A
200 VAC input
0.25 A
100 VAC input
0.5 mA max.
200 VAC input
1 mA max.
100 VAC input
15 A (for a cold start at 25°C)
200 VAC input
30 A (for a cold start at 25°C)
Voltage adjustment range *2
±10% (with V. ADJ)
Ripple *3
150 mV max.
Input variation influence
0.5% max. (with 85 to 264 VAC input at 100% load)
Load variation influence
2% max. (0 to 100%
load, rated input
voltage)
Temperature variation influence
0.05%/°C max.
Startup time (Typ.)
100 VAC input
800 ms
Hold time (Typ.)
100 VAC input
20 ms
Overload protection
Additional Overvoltage protection *4
functions Series operation
240 mV max.
300 mV max.
480 mV max.
960 mV max.
1.5% max. (0 to 100% load, rated input voltage)
105% to 160% of rated current, voltage drop, intermittent, and automatic reset
Yes
Yes (For up to two Power Supplies; external diodes required.)
Parallel operation
No (However, backup operation is possible; external diodes required.)
Ambient operating temperature
−10 to 70°C (Derating is required according to the temperature.) (with no icing or condensation)
Storage temperature
−25 to 75°C (with no icing or condensation)
Ambient operating humidity
25% to 85% (Storage humidity: 25% to 90%)
Dielectric strength
3.0 kVAC for 1 min. (between all inputs and outputs; Cutoff current: 10 mA)
2.0 kVAC for 1 min. (between all inputs and PE; Cutoff current: 10 mA)
1.0 kVAC for 1 min. (between all outputs and PE; Cutoff current: 20 mA)
Insulation resistance
100 MΩ min. (between all outputs and all inputs/PE terminal) at 500 VDC
Vibration resistance
10 to 55 Hz, 19.6 m/s2 (2 G) for 1 h each in X, Y, and Z directions
Shock resistance
196.1 m/s2, 3 times each in ±X, ±Y, ±Z directions
EMI
Other
EMS
Conducted Emissions
Conforms to EN 55011 Group 1 Class B *7
Radiated Emissions
Conforms to EN 55011 Group 1 Class B *7
Electrostatic Discharge
Conforms to EN61000-4-2
Radiated
Electromagnetic Field
Conforms to EN61000-4-3
Electrical
Conforms to EN61000-4-4
Fast Transient/Burst
Surge
Conforms to EN61000-4-5
Conducted Disturbance
Conforms to EN61000-4-6
Voltage Dips/Short
Interruptions
Conforms to EN61000-4-11
Approved standards
UL UR: UL 60950-1 (Recognition)
cUR: CSA C22.2 No. 60950-1
EN: EN50178, EN60950-1
SEMI
SEMI F47-0706 (at 200 VAC)
Weight *5
70 g max. (without chassis and cover)
*1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal
temperature of the Power Supply may result in ignition or burning.
*2. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by +10% of the allowable voltage range. When adjusting the output
voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.
*3. Rated input voltage: 100 or 200 VAC at 100% load.
The measurement method is based on JEITA standard RC-9131A.
For details, refer to Ripple Noise Voltage on page 24.
*4. To reset the protection after power is shut off, turn OFF the input power for three minutes or longer and then turn it back ON.
*5. The weight is for an open-frame model.
*6. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
*7. Class B compliance was met with an aluminum plate placed under the Power Supply.
5
S8EX
Power ratings
Item
Output voltage
Efficiency (Typ.)
Current (Typ.)
Leakage current
Inrush current (Typ.)
12 V
15 V
24 V
48 V
77%
82%
83%
85%
85%
200 VAC input
79%
83%
83%
86%
86%
100 to 240 VAC (allowable voltage: 85 to 264 VAC, 120 to 370 VDC *6)
Frequency *1
Input
5V
100 VAC input
Voltage *1
Output
30 W
50/60 Hz (47 to 450 Hz)
100 VAC input
0.7 A
200 VAC input
0.4 A
100 VAC input
0.5 mA max.
200 VAC input
1mA max.
100 VAC input
15 A (for a cold start at 25°C)
200 VAC input
30 A (for a cold start at 25°C)
Voltage adjustment range *2
±10% (with V. ADJ)
Ripple *3
150 mV max.
Input variation influence
0.5% max. (with 85 to 264 VAC input at 100% load)
Load variation influence
2% max. (0 to 100%
load, rated input
voltage)
Temperature variation influence
0.05%/°C max.
Startup time (Typ.)
100 VAC input
800 ms
Hold time (Typ.)
100 VAC input
20 ms
Overload protection
Additional Overvoltage protection *4
functions Series operation
240 mV max.
300 mV max.
480 mV max.
960 mV max.
1.5% max. (0 to 100% load, rated input voltage)
105% to 160% of rated current, voltage drop, intermittent, automatic reset
Yes
Yes (For up to two Power Supplies; external diodes required.)
Parallel operation
No (However, backup operation is possible; external diodes required.)
Ambient operating temperature
−10 to 70°C (Derating is required according to the temperature.) (with no icing or condensation)
Storage temperature
−25 to 75°C (with no icing or condensation)
Ambient operating humidity
25% to 85% (Storage humidity: 25% to 90%)
Dielectric strength
3.0 kVAC for 1 min. (between all inputs and outputs; Cutoff current: 10 mA)
2.0 kVAC for 1 min. (between all inputs and PE; Cutoff current: 10 mA)
1.0 kVAC for 1 min. (between all outputs and PE; Cutoff current: 20 mA)
Insulation resistance
100 MΩ min. (between all outputs and all inputs/PE terminal) at 500 VDC
Vibration resistance
10 to 55 Hz, 19.6 m/s2 (2 G) for 1 h each in X, Y, and Z directions
Shock resistance
196.1 m/s2, 3 times each in ±X, ±Y, ±Z directions
EMI
Other
EMS
Conducted Emissions
Conforms to EN 55011 Group 1 Class B *7
Radiated Emissions
Conforms to EN 55011 Group 1 Class B *7
Electrostatic Discharge
Conforms to EN61000-4-2
Radiated
Electromagnetic Field
Conforms to EN61000-4-3
Electrical
Conforms to EN61000-4-4
Fast Transient/Burst
Surge
Conforms to EN61000-4-5
Conducted Disturbance
Conforms to EN61000-4-6
Voltage Dips/Short
Interruptions
Conforms to EN61000-4-11
Approved standards
UL UR: UL 60950-1 (Recognition)
cUR: CSA C22.2 No. 60950-1
EN: EN50178, EN60950-1
SEMI
SEMI F47-0706 (at 200 VAC)
Weight *5
110 g max. (without chassis and cover)
*1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal
temperature of the Power Supply may result in ignition or burning.
*2. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by +10% of the allowable voltage range. When adjusting the output
voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.
*3. Rated input voltage: 100 or 200 VAC at 100% load.
The measurement method is based on JEITA standard RC-9131A.
For details, refer to Ripple Noise Voltage on page 24.
*4. To reset the protection after power is shut off, turn OFF the input power for three minutes or longer and then turn it back ON.
*5. The weight is for an open-frame model.
*6. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
*7. Class B compliance was met with an aluminum plate placed under the Power Supply.
6
S8EX
Power ratings
Item
Efficiency (Typ.)
100 VAC input
200 VAC input
Voltage *1
Current (Typ.)
24 V
48 V
79%
83%
82%
82%
81%
86%
85%
85%
50/60 Hz (47 to 63 Hz)
100 VAC input
200 VAC input
0.65 A
0.35 A
0.9 min.
Harmonic current emissions
Conforms to EN 61000-3-2 Class A.
Inrush current (Typ.)
100 VAC input
0.5 mA max.
200 VAC input
1 mA max.
100 VAC input
14.1 A max. (for a cold start at 25°C)
200 VAC input
28.3 A max. (for a cold start at 25°C)
Voltage adjustment range *2
±10% (with V. ADJ)
Ripple *3
150 mV max.
Input variation influence
0.5% max. (with 85 to 264 VAC input at 100% load)
Load variation influence
2% max. (0 to 100%
load, rated input
voltage)
Temperature variation influence
0.05%/°C max.
Startup time (Typ.)
100 VAC input
440 ms
460 ms
500 ms
460 ms
Hold time (Typ.)
100 VAC input
25 ms
20 ms
23 ms
22 ms
Overload protection
240 mV max.
480 mV max.
960 mV max.
1.5% max. (0 to 100% load, rated input voltage)
100% to 110% of rated load current, voltage drop, intermittent, automatic reset
Overvoltage protection *4
Additional
Series operation
functions
Parallel operation
Yes
Yes (For up to two Power Supplies.)
No (However, backup operation is possible; external diodes required.)
Remote control
Yes (Only for models with remote control option.)
Ambient operating temperature
−10 to 70°C (Derating is required according to the temperature.) (with no icing or
condensation)
Storage temperature
−25 to 75°C (with no icing or condensation)
Ambient operating humidity
25% to 85% (Storage humidity: 25% to 90%)
Dielectric strength
3.0 kVAC for 1 min. (between all inputs and outputs; Cutoff current: 10 mA)
2.0 kVAC for 1 min. (between all inputs and PE; Cutoff current: 10 mA)
1.0 kVAC for 1 min. (between all outputs and PE; Cutoff current: 20 mA)
Insulation resistance
100 MΩ min. (between all outputs and all inputs/PE terminal) at 500 VDC
Vibration resistance
10 to 55 Hz, 19.6 m/s2 (2 G) for 1 h each in X, Y, and Z directions
196.1 m/s2, 3 times each in ±X, ±Y, ±Z directions
Shock resistance
Other
12 V
Power factor (rate, 100% load)
Leakage current
Output
5V
100 to 240 VAC (allowable voltage: 85 to 264 VAC, 120 to 370 VDC *6)
Frequency *1
Input
50 W
Output voltage
EMI
EMS
Conducted Emissions
Conforms to EN 55011 Group 1 Class B *7
Radiated Emissions
Conforms to EN 55011 Group 1 Class B *7
Electrostatic Discharge
Conforms to EN61000-4-2
Radiated Electromagnetic Field
Conforms to EN61000-4-3
Electrical Fast Transient/Burst
Conforms to EN61000-4-4
Surge
Conforms to EN61000-4-5
Conducted Disturbance
Conforms to EN61000-4-6
Voltage Dips/Short Interruptions Conforms to EN61000-4-11
Approved standards
UL UR: UL 60950-1 (Recognition)
cUR: CSA C22.2 No. 60950-1
EN: EN50178, EN60950-1
SEMI
SEMI F47-0706 (at 200 VAC)
Weight *5
150 g max. (without chassis and cover)
*1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal
temperature of the Power Supply may result in ignition or burning.
*2. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by +10% of the allowable voltage range. When adjusting the output
voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.
*3. Rated input voltage: 100 or 200 VAC at 100% load.
The measurement method is based on JEITA standard RC-9131A.
For details, refer to Ripple Noise Voltage on page 24.
*4. To reset the protection after power is shut off, turn OFF the input power for three minutes or longer and then turn it back ON.
*5. The weight is for an open-frame model.
*6. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
*7. Class B compliance was met with an aluminum plate placed under the Power Supply.
7
S8EX
Power ratings
Item
Efficiency (Typ.)
100 VAC input
200 VAC input
Voltage *1
Current (Typ.)
24 V
48 V
81%
82%
84%
84%
84%
85%
86%
86%
50/60 Hz (47 to 63 Hz)
100 VAC input
200 VAC input
1.3 A
0.65 A
0.9 min.
Harmonic current emissions
Conforms to EN 61000-3-2 Class A.
Inrush current (Typ.)
100 VAC input
0.5 mA max.
200 VAC input
1 mA max.
100 VAC input
14.1 A max. (for a cold start at 25°C)
200 VAC input
28.3 A max. (for a cold start at 25°C)
Voltage adjustment range *2
±10% (with V. ADJ)
Ripple *3
150 mV max.
Input variation influence
0.5% max. (with 85 to 264 VAC input at 100% load)
Load variation influence
2% max. (0 to 100%
load, rated input
voltage)
Temperature variation influence
0.05%/°C max.
Startup time (Typ.)
100 VAC input
480 ms
530 ms
540 ms
650 ms
Hold time (Typ.)
100 VAC input
24 ms
21 ms
22 ms
24 ms
240 mV max.
480 mV max.
960 mV max.
1.5% max. (0 to 100% load, rated input voltage)
12-V, 24-V, or 48-V model: 100% to 110% of power boost for output current, voltage drop,
intermittent, automatic reset
5-V model: 105% to 160% of rated current, voltage drop, intermittent, automatic reset
Overload protection
Additional Overvoltage protection *4
functions
Series operation
Yes
Yes (For up to two Power Supplies.)
Parallel operation
No (However, backup operation is possible; external diodes required.)
Remote control
Yes (Only for models with remote control option.)
Ambient operating temperature
−10 to 70°C (Derating is required according to the temperature.) (with no icing or
condensation)
Storage temperature
−25 to 75°C (with no icing or condensation)
Ambient operating humidity
25% to 85% (Storage humidity: 25% to 90%)
Dielectric strength
3.0 kVAC for 1 min. (between all inputs and outputs; Cutoff current: 10 mA)
2.0 kVAC for 1 min. (between all inputs and PE; Cutoff current: 10 mA)
1.0 kVAC for 1 min. (between all outputs and PE; Cutoff current: 20 mA)
Insulation resistance
100 MΩmin. (between all outputs and all inputs/PE terminal) at 500 VDC
Vibration resistance
10 to 55 Hz, 19.6 m/s2 (2 G) for 1 h each in X, Y, and Z directions
196.1 m/s2, 3 times each in ±X, ±Y, ±Z directions
Shock resistance
Other
12 V
Power factor (rate, 100% load)
Leakage current
Output
5V
100 to 240 VAC (allowable voltage: 85 to 264 VAC, 120 to 370 VDC *6)
Frequency *1
Input
100 W
Output voltage
EMI
EMS
Conducted Emissions
Conforms to EN 55011 Group 1 Class B *7
Radiated Emissions
Conforms to EN 55011 Group 1 Class B *7
Electrostatic Discharge
Conforms to EN61000-4-2
Radiated Electromagnetic Field
Conforms to EN61000-4-3
Electrical Fast Transient/Burst
Conforms to EN61000-4-4
Surge
Conforms to EN61000-4-5
Conducted Disturbance
Conforms to EN61000-4-6
Voltage Dips/Short Interruptions Conforms to EN61000-4-11
Approved standards
UL UR: UL 60950-1 (Recognition)
cUR: CSA C22.2 No. 60950-1
EN: EN50178, EN60950-1
SEMI
SEMI F47-0706 (at 200 VAC)
Weight *5
265 g max. (without chassis and cover)
*1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal
temperature of the Power Supply may result in ignition or burning.
*2. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by +10% of the allowable voltage range. When adjusting the output
voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.
*3. Rated input voltage: 100 or 200 VAC at 100% load.
The measurement method is based on JEITA standard RC-9131A.
For details, refer to Ripple Noise Voltage on page 24.
*4. To reset the protection after power is shut off, turn OFF the input power for three minutes or longer and then turn it back ON.
*5. The weight is for an open-frame model.
*6. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
*7. Class B compliance was met with an aluminum plate placed under the Power Supply.
8
S8EX
Power ratings
Item
Efficiency (Typ.)
100 VAC input
200 VAC input
Voltage *1
Current (Typ.)
24 V
48 V
84%
83%
84%
85%
87%
86%
87%
88%
50/60 Hz (47 to 63 Hz)
100 VAC input
200 VAC input
1.9 A
0.95 A
0.9 min.
Harmonic current emissions
Conforms to EN 61000-3-2 Class A.
Inrush current (Typ.)
100 VAC input
0.5 mA max.
200 VAC input
1 mA max.
100 VAC input
14.1 A max. (for a cold start at 25°C)
200 VAC input
28.3 A max. (for a cold start at 25°C)
Voltage adjustment range *2
±10% (with V. ADJ)
Ripple *3
150 mV max.
Input variation influence
0.5% max. (with 85 to 264 VAC input at 100% load)
Load variation influence
2% max. (0 to 100%
load, rated input
voltage)
Temperature variation influence
0.05%/°C max.
Startup time (Typ.)
100 VAC input
450 ms
660 ms
660 ms
690 ms
Hold time (Typ.)
100 VAC input
25 ms
20 ms
21 ms
20 ms
240 mV max.
480 mV max.
960 mV max.
1.5% max. (0 to 100% load, rated input voltage)
12-V, 24-V, or 48-V model: 100% to 110% of power boost for output current, voltage drop,
intermittent, automatic reset
5-V model: 105% to 160% of rated current, voltage drop, intermittent, automatic reset
Overload protection
Additional Overvoltage protection *4
functions
Series operation
Yes
Yes (For up to two Power Supplies.)
Parallel operation
No (However, backup operation is possible; external diodes required.)
Remote control
Yes (Only for models with remote control option.)
Ambient operating temperature
−10 to 70°C (Derating is required according to the temperature.) (with no icing or
condensation)
Storage temperature
−25 to 75°C (with no icing or condensation)
Ambient operating humidity
25% to 85% (Storage humidity: 25% to 90%)
Dielectric strength
3.0 kVAC for 1 min. (between all inputs and outputs; Cutoff current: 10 mA)
2.0 kVAC for 1 min. (between all inputs and PE; Cutoff current: 10 mA)
1.0 kVAC for 1 min. (between all outputs and PE; Cutoff current: 20 mA)
Insulation resistance
100 MΩ min. (between all outputs and all inputs/PE terminal) at 500 VDC
Vibration resistance
10 to 55 Hz, 19.6 m/s2 (2 G) for 1 h each in X, Y, and Z directions
196.1 m/s2, 3 times each in ±X, ±Y, ±Z directions
Shock resistance
Other
12 V
Power factor (rate, 100% load)
Leakage current
Output
5V
100 to 240 VAC (allowable voltage: 85 to 264 VAC, 120 to 370 VDC *6)
Frequency *1
Input
150 W
Output voltage
EMI
EMS
Conducted Emissions
Conforms to EN 55011 Group 1 Class B *7
Radiated Emissions
Conforms to EN 55011 Group 1 Class B *7
Electrostatic Discharge
Conforms to EN61000-4-2
Radiated Electromagnetic Field
Conforms to EN61000-4-3
Electrical Fast Transient/Burst
Conforms to EN61000-4-4
Surge
Conforms to EN61000-4-5
Conducted Disturbance
Conforms to EN61000-4-6
Voltage Dips/Short Interruptions Conforms to EN61000-4-11
Approved standards
UL UR: UL 60950-1 (Recognition)
cUR: CSA C22.2 No. 60950-1
EN: EN50178, EN60950-1
SEMI
SEMI F47-0706 (at 200 VAC)
Weight *5
315 g max. (without chassis and cover)
*1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal
temperature of the Power Supply may result in ignition or burning.
*2. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by +10% of the allowable voltage range. When adjusting the output
voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.
*3. Rated input voltage: 100 or 200 VAC at 100% load.
The measurement method is based on JEITA standard RC-9131A.
For details, refer to Ripple Noise Voltage on page 24.
*4. To reset the protection after power is shut off, turn OFF the input power for three minutes or longer and then turn it back ON.
*5. The weight is for an open-frame model.
*6. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
*7. Class B compliance was met with an aluminum plate placed under the Power Supply.
9
S8EX
Power ratings
Item
Efficiency (Typ.)
100 VAC input
200 VAC input
Voltage *1
Current (Typ.)
87%
90%
90%
90%
50/60 Hz (47 to 63 Hz)
100 VAC input
2.9 A (for 240-W output)
200 VAC input
1.5 A (for 240-W output)
1.8 A (for 300-W output)
0.9 min.
Conforms to EN 61000-3-2 Class A.
100 VAC input
0.5 mA max.
200 VAC input
1.0 mA max.
100 VAC input
14 A (for a cold start at 25°C)
200 VAC input
28 A (for a cold start at 25°C)
Voltage adjustment range *2
±10% (with V. ADJ)
Ripple *3
480 mV max.
Input variation influence
0.5% max.
Load variation influence
1.5% max.
Temperature variation influence
0.05%/°C max.
Startup time (Typ.)
Hold time (Typ.)
48 V
87%
Harmonic current emissions
Inrush current (Typ.)
720 mV max.
100 VAC input
460 ms
200 VAC input
330 ms
100 VAC input
20 ms (for output power of 240 W)
200 VAC input
20 ms (for output power of 240 W)
16 ms (for output power of 300 W)
960 mV max.
100% or higher of power boost for output current, voltage drop, automatic reset
Power shut off if 130% or higher of rated output current continues for approx. 5 s
Reset by input reset (OFF time: 3 min min.)
Overload protection *4
Overvoltage protection *4
Additional
functions Series operation
Parallel operation
Yes
Yes (For up to two Power Supplies; external diodes are required.)
No (However, backup operation is possible; external diodes required.)
Remote control
Yes (Only for models with remote control option.)
Undervoltage alarm output
Yes (open-collector output, 30 VDC max., 50 mA max.)
Ambient operating temperature
−10 to 70°C (Derating is required according to the temperature.) (with no icing or
condensation)
Storage temperature
−25 to 75°C (with no icing or condensation)
Ambient operating humidity
25% to 85%
Dielectric strength
3.0 kVAC for 1 min. (between all inputs and outputs; Cutoff current: 10 mA)
2.0 kVAC for 1 min. (between all inputs and PE; Cutoff current: 10 mA)
1.0 kVAC for 1 min. (between all outputs and PE; Cutoff current: 20 mA)
Insulation resistance
100 MΩ min. (between all outputs and all inputs/PE terminal) at 500 VDC (at room
temperature 25°C and humidity 60%)
Vibration resistance
No abnormality after 10 to 55 Hz, 19.6 m/s2 (2 G) for 1 h each in X, Y, and Z directions.
196.1 m/s2, 3 times each in ±X, ±Y, ±Z directions
Shock resistance
Other
36 V
87%
Power factor (rate, 100% load)
Leakage current
Output
24 V
100 to 240 VAC (allowable voltage: 85 to 264 VAC, 120 to 370 VDC *6)
Frequency *1
Input
240 W (300 W)
Output voltage
EMI
EMS
Conducted Emissions
Conforms to EN 55011 Group 1 Class B *7
Radiated Emissions
Conforms to EN 55011 Group 1 Class B *7*8
Electrostatic Discharge
Conforms to EN61000-4-2
Radiated Electromagnetic Field
Conforms to EN61000-4-3
Electrical Fast Transient/Burst
Conforms to EN61000-4-4
Surge
Conforms to EN61000-4-5
Conducted Disturbance
Conforms to EN61000-4-6
Voltage Dips/Short Interruptions Conforms to EN61000-4-11
Approved standards
UL UR: UL 60950-1 (Recognition)
cUR: CSA C22.2 No. 60950-1
EN: EN50178, EN60950-1
SEMI
SEMI F47-0706 (at 200 VAC)
Weight *5
515 g (without chassis and cover)
*1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the
Power Supply may result in ignition or burning.
*2. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by +10% of the allowable voltage range. When adjusting the output voltage, confirm the
actual output voltage from the Power Supply and be sure that load is not damaged.
*3. Rated input voltage: 100 or 200 VAC at 100% load.
The measurement method is based on JEITA standard RC-9131A. For details, refer to Ripple Noise Voltage on page 24.
*4. To reset the protection after power is shut off, turn OFF the input power for three minutes or longer and then turn it back ON.
*5. The weight is for an open-frame model.
*6. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
*7. Noise values depend on the wiring methods. Class B compliance was met with an aluminum plate placed under the Power Supply.
*8. Insert filters (ZCAT3035-1330 manufactured by TDK Corporation) in the input and output lines to reduce noise.
10
S8EX
Connections
Block Diagrams
S8EX-N015@@ (15 W)
S8EX-N030@@ (30 W)
AC(L)
+V
Fuse*
INPUT
Noise
filter
DC OUTPUT
AC(N)
-V
Inrush
Smoothing
current
circuit
protection
Rectifier
*15 W: 2.5 A
30 W: 4.0A
Rectifier/
Smoothing circuit
Drive control
Circuit
Overcurrent
detection
circuit
Voltage
detection
Overvoltage
detection
circuit
Photocoupler
S8EX-BP050@@ (50 W)
S8EX-@P100@@ (100 W)
S8EX-@P150@@ (150 W)
+V
AC(L)
Fuse*
INPUT
Noise
filter
DC OUTPUT
AC(N)
-V
Rectifier
* 50 W: 4.0 A
100 W: 6.3 A
150 W: 8.0 A
Inrush
Harmonic current Smoothing
current
circuit
suppression
protection
Rectifier/
Smoothing circuit
Drive control
Circuit
Overcurrent
detection
circuit
Voltage
detection
Overvoltage
detection
circuit
Photocoupler
+RC
Remote control
Photocoupler
-RC
Only for models with remote control option.
S8EX-BP240@@ (240 W)
AC(L)
Fuse: 10 A
INPUT
+V
Noise
filter
DC OUTPUT
AC(N)
-V
Rectifier
Harmonic current
suppression
Inrush current
protection
Smoothing
circuit
Rectifier/
Smoothing circuit
Drive control
Circuit
DC LOW OUT
Overcurrent
detection
circuit
Voltage
detection
Undervoltage
detection output
Overvoltage
detection
circuit
Photocoupler
+RC
Remote control
Photocoupler
-RC
Only for models with remote control option
11
S8EX
Construction and Nomenclature
Nomenclature
S8EX-N015@@@@
No.
Name
Function
6
2
1
CN51
1
Input Terminals (L), (N)
Connect the input lines to these
terminals. *1
2
Protective Earth Terminal (PE)
Connect the ground line to these
terminals. *2
3
DC Output Terminals (−V), (+V)
Connect the load lines to these
terminals.
6
4
Output Voltage Adjuster (V. ADJ)
It is possible to increase or decrease the
output voltage.
3
5
Chassis
4
6
Cover
7
Undervoltage alarm output
collector terminal (DC LOW)
8
Undervoltage alarm output emitter
terminal (DC LOW)
9
Remote control +RC terminal *3
10
Remote control −RC terminal *3
3
4
CN1
5
S8EX-N015@@@@-CN1
2
1
CN51
CN1
5
S8EX-N030@@@@
6
2
1
CN51
3
4
CN1
S8EX-BP050@@@
9 10
4
1
Wire for remote control.
*1. The fuse is located on the (L) side. It is NOT user-replaceable. For a DC
power input, connect the low side to the positive (+) terminal. Safety
standards do not apply for a DC input.
*2. This is the protective earth terminal specified in the safety standards.
Always ground this terminal.
*3. Only for models with remote control option.
5
2
Output a signal when a low output
voltage is detected.
3
CN1
CN51
5
6
S8EX-@P100@@@
6
5
CN51
2
3
1
4
9 10
CN1
S8EX-@P150@@@
5
CN52
2
1
3
CN1
CN51
4
9 10
6
S8EX-BP240@@@@
6
5
CN51
3
2
1
9 10
4
7 8
CN1
Input and Output Connectors
Housing
B3P5-VH(LF)(SN)
VHR-5N
Input side
All models
Output side
S8EX-N015@@@@
S8EX-N030@@@@
S8EX-BP050@@@
CN51
B4P-VH(LF)(SN)
VHR-4N
Output side
S8EX-N015@@@@-CN1
CN51
B4B-XH
XHP-4
Output side
S8EX-@P100@@@
CN51
B8P-VH(LF)(SN)
VHR-8N
S8EX-@P150@@@
CN51
B6P-VH(LF)(SN)
VHR-6N
CN52
B7P-VH(LF)(SN)
VHR-7N
S8EX-BP240@@@@
CN51
B8P-VH(LF)(SN)
VHR-8N
Output side
Output side
Output side
Manufacturer
CN1
Applicable
connector
Applicable
crimp tool
YC-160R
Reel: SVH-21T-P1.1
Bulk: BVH-21T-P1.1
Reel: SXH-001T-P0.6
Bulk: BXH-001T-P0.6
YC-160R
YC-111R
YC-160R
Reel: SVH-21T-P1.1
Bulk: BVH-21T-P1.1
J.S.T. Mfg. Co., Ltd.
Note: The female connectors that are required for wiring are not provided with the Power Supply.
12
Terminals
YC-160R
YC-160R
YC-160R
S8EX
Special Harnesses for S8EX-Series
Applicable Models and Harness Models
Applicable models (S8EX-Series)
Connected to
15 W
30 W
50 W
100 W
150 W
240 W
OK
OK
OK
OK
OK
OK
OK
OK
OK
Input side and output side
Input side
Output side
OK
OK
OK
OK
OK
OK
OK
OK
S82Y-EX01HO-01
Output (±), common
S82Y-EX02HO-01
Output side
Output side
Output side +
S82Y-EX04HO-01
OK
Output side
Output side −
S82Y-EX05HO-01
OK
Input side
S82Y-EX01HI-10
Output side
OK*
Output side
OK
OK
1
S82Y-EX03HO-01
OK
OK
Qty
S82Y-EX01HI-01
Output side
OK*
OK
Model number
Output (+, −)
S82Y-EX01HO-10
Output (±), common
S82Y-EX02HO-10
Output side
10
S82Y-EX03HO-10
OK
Output side
Output side +
S82Y-EX04HO-10
OK
Output side
Output side −
S82Y-EX05HO-10
* Application is possible only to the S8EX-CN1.
Harness Specifications
Model number
S82Y-EX01HI-@@
S82Y-EX01HO-@@
S82Y-EX02HO-@@
S82Y-EX03HO-@@
Connector structure
Housing
Model: VHR-5N
Manufacturer: J.S.T. Mfg. Co., Ltd.
Pins
Model: SVH-21T-P1.1
Manufacturer: J.S.T. Mfg. Co., Ltd.
Housing
Model: VHR-4N
Manufacturer: J.S.T. Mfg. Co., Ltd.
Pins
Model: SVH-21T-P1.1
Manufacturer: J.S.T. Mfg. Co., Ltd.
Housing
Model: XHP-4
Manufacturer: J.S.T. Mfg. Co., Ltd.
Pins
Model: SXH-001T-P0.6
Manufacturer: J.S.T. Mfg. Co., Ltd.
Housing
Model: VHR-8N
Manufacturer: J.S.T. Mfg. Co., Ltd.
Pins
Model: SVH-21T-P1.1
Manufacturer: J.S.T. Mfg. Co., Ltd.
Shape
1
2
3
4
5
S82Y-EX04HO-@@
S82Y-EX05HO-@@
Housing
Model: VHR-7N
Manufacturer: J.S.T. Mfg. Co., Ltd.
Pins
Model: SVH-21T-P1.1
Manufacturer: J.S.T. Mfg. Co., Ltd.
Pin
Wire
AWG
Color
Length: L (mm)
1
UL1015
18
Black
500
2
3
L
+50
−0
1
2
3
4
+50
L −0
1
2
3
4
+50
L −0
1
2
3
4
5
6
7
8
L +50
−0
Housing
Model: VHR-6N
Manufacturer: J.S.T. Mfg. Co., Ltd.
Pins
Model: SVH-21T-P1.1
Manufacturer: J.S.T. Mfg. Co., Ltd.
Applicable wires
1
2
3
4
5
6
L +50
−0
1
2
3
4
5
6
7
L +50
−0
NC
UL1015
18
4
White
500
NC
5
UL1015
18
Green
500
Pin
Wire
AWG
Color
Length: L (mm)
1
UL1015
18
Black
500
2
UL1015
18
Black
500
3
UL1015
18
Red
500
4
UL1015
18
Red
500
Pin
Wire
AWG
Color
Length: L (mm)
1
UL1007
22
Black
500
2
UL1007
22
Black
500
3
UL1007
22
Red
500
4
UL1007
22
Red
500
Pin
Wire
AWG
Color
Length: L (mm)
1
UL1015
18
Black
500
2
UL1015
18
Black
500
3
UL1015
18
Black
500
4
UL1015
18
Black
500
5
UL1015
18
Red
500
6
UL1015
18
Red
500
7
UL1015
18
Red
500
8
UL1015
18
Red
500
Pin
Wire
AWG
Color
Length: L (mm)
1
UL1015
18
Red
500
2
UL1015
18
Red
500
3
UL1015
18
Red
500
4
UL1015
18
Red
500
5
UL1015
18
Red
500
6
UL1015
18
Red
500
Pin
Wire
AWG
Color
Length: L (mm)
1
UL1015
18
Black
500
2
UL1015
18
Black
500
3
UL1015
18
Black
500
4
UL1015
18
Black
500
5
UL1015
18
Black
500
6
UL1015
18
Black
500
7
UL1015
18
Black
500
13
S8EX
Chassis cover option
Applicable models
Model number
15W
S82Y-EX030LC
30W
50W
S82Y-EX050LC
100W
S82Y-EX100LC
150W
S82Y-EX150LC
240W
S82Y-EX240LC
Engineering Data
Derating Curves (Standard Mounting)
Open-frame Models and Models
with Chassis (15 W)
Models with Chassis and Cover (15 W)
Load 120
rate
(%)
100
Load 120
rate
(%)
100
80
80
60
60
40
40
20
0
−10
20
Mounting method A, B, C, and D
Mounting method E and F
0
10
20
30
40
50
60
70 80
Ambient Temperature (°C)
Open-frame Models and Models
with Chassis (30 W)
0
−10
Load 120
rate
(%)
100
80
80
60
60
40
40
0
−10
Mounting method B
Mounting method A, C, D, and E
Mounting method F
0
10
20
30
40
50
60
0
10
20
30
Mounting method B
Mounting method A, C, D, and E
Mounting method F
20
70
80
0
−10
0
10
20
30
Ambient Temperature (°C)
Open-frame Models (50W)
40
50
60
70 80
Ambient Temperature (°C)
Models with Chassis (50 W)
Models with Chassis and Cover (50W)
Load 120
rate
(%)
100
Load 120
rate
(%)
100
Load 120
rate
(%)
100
80
80
80
60
60
60
40
0
-10
40
40
Mounting method A, B, and C
Mounting method D
Mounting method E
Mounting method F
20
14
40
50
60
70 80
Ambient Temperature (°C)
Models with Chassis and Cover (30 W)
Load 120
rate
(%)
100
20
Mounting method A, B, C, and D
Mounting method E and F
0
10
20
30
40
50
60
70 80
Ambient Temperature (°C)
Mounting method A, B, and C
Mounting method D
Mounting method E
Mounting method F
20
0
−10
0
10
20
30
40
50
60
70 80
Ambient Temperature (°C)
Mounting method A, B, and C
Mounting method D
Mounting method E
Mounting method F
20
0
-10
0
10
20
30
40
50
60
70 80
Ambient Temperature (°C)
S8EX
Open-frame Models (100W)
Models with Chassis (100 W)
Load 120
rate
(%)
100
Models with Chassis and Cover (100W)
Load 120
rate
(%)
100
Load 120
rate
(%)
100
80
80
85
85
80
75
70
75
70
60
40
Mounting method A and B
Mounting method C and E
Mounting method D
Mounting method F
20
0
-10
0
10
20
30
60
60
40
40
Mounting method A and B
Mounting method C and E
Mounting method D and F
20
0
−10
40
50
60
70 80
Ambient Temperature (°C)
Open-frame Models (150 W)
0
10
20
30
Mounting method A and B
Mounting method C and E
Mounting method D
Mounting method F
20
40
50
60
70 80
Ambient Temperature (°C)
Models with Chassis (150 W)
0
-10
0
10
20
30
40
50
60
70 80
Ambient Temperature (°C)
Models with Chassis and Cover (150 W)
Load 120
rate
(%)
100
Load 120
rate
(%)
100
Load 120
rate
(%)
100
80
80
80
85
75
70
60
60
40
60
40
Mounting method A and B
Mounting method C and E
Mounting method D
Mounting method F
20
0
-10
0
10
20
30
40
Mounting method A and B
Mounting method C and E
Mounting method D
Mounting method F
20
40
50
60
70 80
Ambient Temperature (°C)
Open-frame Models and Models with Chassis (240 W)
Load 120
rate
(%)
100
0
-10
10
20
30
40
50
60
70 80
Ambient Temperature (°C)
0
-10
0
10
20
30
40
50
60
70 80
Ambient Temperature (°C)
Models with Chassis and Cover (240W)
Load 120
rate
(%)
100
85
85
80
80
75
70
75
70
60
60
40
40
Mounting method A
Mounting method B and C
Mounting method E
Mounting method D and F
20
0
−10
0
Mounting method A and B
Mounting method C and E
Mounting method D
Mounting method F
20
0
10
20
30
Mounting method A
(Standard mounting method)
Mounting method A
Mounting method B and C
Mounting method E
Mounting method D and F
20
0
−10
40
50
60
70 80
Ambient Temperature (°C)
Mounting method B
0
10
20
Mounting method C
30
40
50
60
70 80
Ambient Temperature (°C)
Mounting method D
Mounting method F *
Mounting method E
CN1
FIN
CN1
CN1
*
CN1
*
*
CN1
FIN
*
*
*
CN1
* UL certification has
not been obtained
for 240-W models.
Note: 1. Use a metal sheet* for the mounting surface.
2. Refer to Ambient Operating and Storage Environments on page 22.
3. A natural convection system is used for derating. Mount the Power Supply so that air convection will occur around it.
15
S8EX
Input Voltage Derating Curve
Overvoltage Protection
For 50, 100, 150, and 240-W models, check the derating
characteristics for the input voltage before using the Power Supply.
Consider the possibility of an overvoltage and design the system so
that the load will not be subjected to an excessive voltage even if the
feedback circuit in the power supply fails. When an excessive voltage
that is approximately 130% of the rated voltage or more is output, the
output voltage is shut OFF, preventing damage to the load due to
overvoltage. Reset the input power by turning it OFF for at least three
minutes and then turning it back ON again.
Load
rate
(%) 100
90
85
Output voltage (V)
Reference Graph
90
Input voltage (VAC)
Overload Protection
The overload protection circuit will automatically reduce the output
voltage for short circuits and overcurrents to protect the Power Supply
from short-circuit currents and overcurrents.
Note: Refer to Overload Protection on page 24.
Rated output
Voltage
Overvoltage
protection
Operating
Variable range
15 to 150-W Models
When the output current falls within the rated range, the overload
protection function is automatically cleared.
Reference Graphs
Models without Power
Boost Function
Intermittent
operation
Output voltage (V)
Output voltage (V)
Models with Power Boost
Function
0V
Note: Do not turn ON the power again until the cause of the
overvoltage has been removed.
Inrush Current, Startup Time, Output Hold Time
Input ON
Input OFF
AC input
voltage
Intermittent
operation
Inrush current on input application
AC input
current
0
Maximum boost current
0
Rated current
96.5%
90%
240-W Models
The output will be shut off if an output of 310 W or higher continues
for approximately 5 seconds. To reset the protection, turn OFF the
input power for three minutes or longer and then turn it back ON.
Reference Graph
Rated voltage
Overcurrent Curve
Maximum boost current
16
Output
voltage
Startup time
Hold time
Note: A maximum startup time of 1,000 ms is required. Construct a
system configuration that considers the startup time of other
devices.
S8EX
Remote Control Function
(S8EX-@@@@@@@@@-R only)
Undervoltage Alarm Function (240 W Only)
This function is to turn ON/OFF the output by applying a voltage to the
remote control connector from a DC Power Supply (external power
supply) other than this Power Supply.
Built-in
resistance Ri (Ω)
Voltage between +RC and −RC (V)
Output ON
Output OFF
4.5 to 12.5
0 to 0.5
1kΩ
R Note 1
External
power supply
(SELV output)
Inrush current
(mA)
20 max.
Inside the power
supply
Switch
+RC
1
Ri
When a drop of output voltage is detected, the voltage is output to the
outside by a transistor (DC LOW) (The output is OFF when the output
voltage is low). The detection voltage is set approximately 80% (75 to
90%) of the rated output voltage.
Note: 1. Transistor output: Open collector
30 VDC max., 50 mA max. ON: Residual voltage 2 V max.,
OFF: Leakage voltage 0.1 mA max.
2. The undervoltage alarm function monitors the voltage of the
output terminal of the power supply unit.
To check the accurate voltage condition, measure the
voltage of the load side.
3. If the setting voltage is set to 90% or less of the rated
voltage, the undervoltage alarm function may operate.
Inflowing current
Collector
−RC
1
2
Emitter
Remote control connector (CN61)
Undervoltage alarm
output connector (CN62)
Usage example of the remote control
Connectors used:
CN61
Model
Manufacturer
B2B-XH-A
2
Output connector No. 2 (Emitter) is connected with the negative output.
Connectors used:
Applicable
connector
Applicable
contact
XHP-2
SXH-001T-P0.6
or
SXH-002T-P0.6
J.S.T. Mfg. Co., Ltd.
Applicable crimp tool: YC-110R (J.S.T. Mfg. Co., Ltd.) or
YRS-110 (J.S.T. Mfg. Co., Ltd.)
Model
Manufacturer
CN62
Applicable
connector
Applicable contact
B2B-XH-A
XHP-2
SXH-001T-P0.6
or
SXH-P002T-P0.6
JST Mfg. Co., Ltd.
Applicable crimp tool: YC-110R (JST Mfg. Co., Ltd.) or
YRS-110 (JST Mfg. Co., Ltd.)
Note: 1. When the external power supply is 4.5 to 12.5 V, the current
limiting resistor R is not required. When it is 12.5 to 24.5 V,
insert 1.5 kΩ as the current limiting resistor R.
2. Reverse connection of the connector may cause damage
on the internal parts.
3. The +RC and -RC terminals are the secondary circuit of the
power supply. Use an SELV output power supply for an
external power supply. The remote control circuit is
insulated from the secondary output of the power supply
(functional insulation).
17
S8EX
Dimensions
(Unit: mm)
Power Supplies
Open-frame Model
S8EX-N015@ (15 W)
Four, 3.5-dia.
mounting holes
105±1
5
Output (-)
50±1
Input (N)
40±0.5
Input (L)
Output (+)
V.ADJ
3.5
4
17.5±0.5
5
95±0.5
18±1
4 max. (height with components mounted)
S8EX-N030@ (30 W)
Three, 3.5-dia.
mounting holes
105±1
5
50±1
40
Output (-)
Input (N)
Output (+)
Input (L)
V.ADJ
3.5
4
95±0.5
5
23±1
4 max. (height with components mounted)
S8EX-BP050@@ (50 W)
Only models with remote control.
+RC −RC
Four, 3.5-dia.
mounting holes
5
3
Input (N)
V.ADJ
1
Input (L)
CN51
50±1
40±0.5
5
5
CN1
122±0.5
132±1
25±1
3.5 max. (height with components mounted)
18
1
2
3
4
Output (-)
Output (+)
S8EX
S8EX-@P100@@ (100 W)
Four, 3.5-dia.
mounting holes
1
Output (-)
5
62±1
52±0.5
CN51
3
Input (N)
1
Input (L)
Output (+)
8
CN1
V.ADJ
+RC
-RC
Only models with
remote control.
5
5
145±0.5
155±1
32±1
3.5 max. (height with components mounted)
S8EX-@P150@@ (150 W)
Four, 3.5-dia.
mounting
holes
1
CN52
Output (-)
5
75±1
65±0.5
3
Input (N)
1
Input (L)
7
1
CN51
Output (+)
CN1
V.ADJ
5
5
150±0.5
160±1
-RC
+RC
6
Only models with
remote control.
34±1
3.5 max. (height with components mounted)
S8EX-@BP240@@ (240 W)
Five, 3.5-dia.
mounting holes
CN51
1
Output (−)
84±1
5
74±0.5
3
Input (N)
1
Input (L)
Output (+)
8
CN61
CN1
CN62
89±0.5
5
5
+RC
-RC
Only models with
remote control.
Undervoltage alarm output terminals (DC low)
170±0.5
180±1
Output voltage
adjuster (V.ADJ)
39±1
3.5 max. (height with components mounted)
19
S8EX
With chassis and cover
S8EX-N015@L@ (15 W)
5 Four, M3
mounting holes
115±0.5
3.5 dia.
15
Output (-) 30
3.5
Input (N)
60±1
Input (L)
Output (+)
30±0.5
V.ADJ
125±1
115±0.5
5
3.5
3.5 dia.
11
Two, M3
mounting
holes
36±1
16
S8EX-N030@L@ (30 W)
5 Four, M3
mounting holes
115±0.5
3.5 dia.
15
Output (-)30
3.5
Input (N)
60±1
Input (L)
Output (+)
30±0.5
V.ADJ
125±1
115±0.5
5
3.5
3.5 dia.
11
Two, M3
mounting
holes
36±1
16
S8EX-BP050@L@ (50 W)
Two,
3.5 dia.
6
150±0.5
Four, M3
mounting
holes
10
20
Input (N)
Input (L)
5
30
V.ADJ
3.5
CN51
3
1
2
3
4
1
CN1
20±0.5
60±1
Output (-)
Output (+)
40±0.5
162±1
150±0.5
3.5 dia.
6
3.5
10
36±1
Two, M3
mounting
holes
20
15
S8EX
S8EX-@P100@L@ (100 W)
Two,
4.5 dia.
173±0.5
Four, M4
mounting
holes
6
13
23
36
1
5
Input (N)
3
Input (L)
1
CN51
Output
(-)
72±1
Output
(+) 4.5
V.ADJ
8
CN1
25±0.5
45±0.5
185±1
173±0.5
6
4.5 dia.
Two, M4
mounting
holes
4.5 15
45±1
20
S8EX-@P150@L@ (150 W)
Two,
4.5 dia.
15
6
176±0.5
Four, M4
mounting
holes
25
1
CN52
Output (-)
42
5
85±1
7
Input (N)
3
Input (L)
1
1
4.5
CN51
Output (+)
CN1
35±0.5
6
V.ADJ
55±0.5
188±1
176±0.5
6
4.5 dia.
4.5
Two, M4
mounting
holes
S8EX-BP240@L@ (240 W)
47±1
20
Two, 4.5
dia.
15
15
6 Four, M4
mounting holes
200±0.5
25
CN51
1
47.5
Output (−)
4.5
5
Input (N)
3
Input (L)
1
95±1
8
Output (+)
CN1
45±0.5
CN62
65±0.5
Undervoltage alarm output terminals (DC LOW)
Output voltage adjuster (V.ADJ)
212±1
200±0.5
6
4.5 dia.
4.5
30
53±1
Two, M4
mounting holes
30
4.5
15
21
S8EX
Safety Precautions
Refer to Safety Precautions for All Power Supplies.
Warning Indications
Indicates a potentially hazardous situation
Precautions for Safe Use
CAUTION which, if not avoided, may result in minor or
moderate injury or in property damage.
Precautions for Supplementary comments on what to do or
avoid doing, to use the product safely.
Safe Use
Supplementary comments on what to do or
Precautions for avoid doing, to prevent failure to operate,
malfunction or undesirable effect on
Correct Use
product performance.
Meaning of Product Safety Symbols
Used to warn of the risk of electric shock under
specific conditions.
Use to indicate prohibition when there is a risk of
minor injury from electrical shock or other source if
the product is disassembled.
Used for general CAUTION, WARNING, or
DANGER precautions for which there is no
specified symbol. (This symbol is also used as the
alerting symbol, but shall not be used in this
meaning on the product.)
Used to warn of the risk of minor injury caused by
high temperatures.
CAUTION
Minor electric shock, fire, or Product failure may
occasionally occur. Do not disassemble, modify, or
repair the Product to touch the interior of the
Product.
Minor burns may occasionally occur. Do not touch
the Product while power is being supplied or
immediately after power is turned OFF.
Minor injury due to electric shock may occasionally
occur. Do not touch the terminals while power is
being supplied. Working voltage can be 370V max.
inside. This voltage can be also available 30s after
the switch off.
Minor electric shock, fire, or Product failure may
occasionally occur. Do not allow any pieces of metal
or conductors or any clippings or cuttings resulting
from installation work to enter the Product.
22
Wiring
• Connect the ground completely. A protective earthing terminal
stipulated in safety standards is used. Electric shock or malfunction
may occur if the ground is not connected completely.
• Minor fire may possibly occur. Ensure that input and output
terminals are wired correctly.
• Be sure to remove the sheet covering the Product for machining
before power-ON so that it does not interfere with heat dissipation.
• Use a wire diameter of at least 1.6 times the diameter that is
required for the rated current to prevent heating and ignition of wire
materials due to load abnormalities. Refer to the recommended
allowable current, voltage drop, and other specifications from the
manufacturer of the wires to select suitable wiring materials.
• The current rating of each output terminal is 2 A for -CN1
models and it is 5 A for all other models. If more than the
terminal current rating will flow, use two or more terminals
together.
• Use wiring materials with a UL recognized temperature of 60°C
min. or 60°C/75°C min.
• Use wiring materials with copper conductors.
• Refer to Input and Output Connectors on page 12 for the model
numbers of the input and output connectors. Do not insert and
remove any connector more than 20 times.
Installation Environment
• Do not use the Power Supply in locations subject to shocks or
vibrations. In particular, install the Power Supply as far away as
possible from contactors or other devices that are a vibration
source.
• Install the Power Supply well away from any sources of strong,
high-frequency noise and surge.
Ambient Operating and Storage Environments
• Store the Power Supply at a temperature of -25 to 75°C and a
humidity of 25% to 90%.
• The Internal parts may occasionally deteriorate or be damaged.
Do not use the Power Supply beyond the operating temperature
range for the installation direction.
• The Internal parts may occasionally deteriorate or be damaged.
Do not use the Power Supply outside the derating range (i.e., the
area shown by shading 1 in the derating curve diagram.)
• Use the Power Supply at a humidity of 25% to 85%.
• Do not use the Power Supply in locations subject to direct sunlight.
• Do not use locations where liquids, foreign matter, or corrosive
gases may enter the interior of the Product.
S8EX
Precautions for Correct Use
Mounting
Output Voltage Adjuster (V.ADJ)
Default Setting: Set at the rated voltage
Adjustment Range : The output voltage can be adjusted to ±10% of
the rated voltage with the voltage output adjuster
(V.ADJ) on the front panel. Turning clockwise
increases the output voltage, and turning
counterclockwise decreases the output voltage.
• The output voltage adjuster (V.ADJ) may possibly be damaged if it
is turned with unnecessary force. Do not turn the adjuster with
excessive force.
• After completing output voltage adjustment, be sure that the output
capacity or output current does not exceed the rated output
capacity or rated output current.
• Adjusting the output voltage adjuster (V.ADJ) may cause the
output voltage to exceed the voltage range. When adjusting the
output voltage, check the output voltage of the Power Supply and
be sure that the load is not destroyed.
Mounting interval
4 mm min.
CN1
8 mm min.
4 mm min.
4 mm min.
CN1
4 mm min.
4 mm min.
Mounting hole position
<15 to 150 W>
8 mm
8 mm
<240 W>
8mm
CN1
8 mm
8 mm
8mm
8 mm
8 mm
8 mm
8 mm
8 mm
8 mm
8 mm
CN1
Series Operation
8 mm
8 mm
8 mm
8 mm
• Take adequate measures to ensure proper heat dissipation to
increase the long-term reliability of the Product.
• The S8EX-series are designed to radiate heat by means of natural
air-flow. Be sure to allow convection in the atmosphere around
devices when mounting.
• The shaded portions indicate the allowable range of the metal
mounting parts.
• When mounting, use the mounting holes in the board and spacers
to mount at least 8 mm off the board. This a clearance of 4 mm
space is necessary to satisfy the insulation and withstand voltage
standards.
• Metal plate is strongly recommended as the mounting panel.
Note: 1. Do not subject the board to stress such as twisting, bending,
or shock. This may cause failure or deterioration.
2. During assembly, do not subject the lead feet or surface
mounted parts to stress. This may cause failure or
deterioration.
• Do not allow cuttings to enter the Power Supply during installation.
• Depending on how the Power Supply is mounted, the heat
dissipating capacity may be reduced and cause deterioration to or
damage internal components.
• The internal parts may occasionally deteriorate and be broken due
to adverse heat radiation. Do not loosen the screws on the Power
Supply.
Two power supplies can be connected in series. The (±) voltage
output can be accomplished with two Power Supplies.
Series Operation
Correct
Output Voltage (±)
Correct
AC(L)
+V
AC(L)
+V
AC(N)
-V
AC(N)
-V
AC(L)
+V
AC(L)
+V
AC(N)
-V
AC(N)
-V
Note: 1. If the load is short-circuited, a reverse voltage will be
generated inside the Power Supply. If this occurs the Power
Supply may possibly deteriorate or be damaged. Always
connect a diode as shown in the figure. Select a diode
having the following ratings.
Type
Schottky Barrier diode
Dielectric strength (VRRM)
Twice the rated output voltage or above
Forward current (IF)
Twice the rated output current or above
2. Although Products having different specifications can be
connected in series, the current flowing through the load
must not exceed the smaller rated output current.
23
S8EX
Parallel Operation
In Case There Is No Output Voltage
The Product is not designed for parallel operation.
The possible cause for no output voltage may be that the overcurrent
or overvoltage protection has operated. The internal protection may
operate if a large amount of surge voltage such as a lightening surge
occurs while turning ON the Power Supply.
In case there is no output voltage, please check the following points
before contacting us:
• Checking overcurrent protected status:
Check whether the load is in overcurrent status or is shortcircuited. Remove wires to load when checking.
• Checking overvoltage or internal protection:
Turn the power supply OFF once, and leave it OFF for at least
3 minutes for S8JX-P series. Then turn it ON again to see if this
clears the condition.
Parallel Operation
Incorrect
AC(L)
+V
AC(N)
-V
AC(L)
+V
AC(N)
-V
However, the following backup operation is possible. (External diodes
are required.)
A
D1
Load
+V
−V
B
D2
+V
−V
Use the same model for Power Supplies A and B.
• Type: Schottky barrier diode
• Dielectric strength (VRRM): Rated output voltage of the Power
Supply or higher
• Forward current (IF): Twice the rated output current of the Power
Supply or higher
• Set the output voltages of Power Supplies A and B higher to
compensate for the decrease of the forward voltages (VF) of diodes
D1 and D2. Also, there will be a power loss equivalent to the output
current (Iout) of the Power Supply multiplied by the forward voltage
(VF) of the diode. Therefore, cooling will be required to keep the
temperature of the diodes lower than the catalog value.
• There will be a power loss caused by load power and diodes. Be
sure not to exceed the rated power (rated output voltage times
rated output current) of each Power Supply.
Power Boost Function
• Do not allow the boost current to continue for more than the time
given in the following figure (t1). Also, do not let the duty cycle
exceed the following conditions. This may damage the power
supply.
• Lessen the load of the boost load current by adjusting the ambient
temperature and the mounting orientation.
• Ensure that the average current of one cycle of the boost current
does not exceed the specified value. Doing so may cause the
Power Supply to fail.
lp : Boost current
[A]
lave : Average current
Output
current
t1
t2
Models
Boost current conditions
• t1 ≤ 10s
• Ip ≤ Rated boost current
• Iave ≤ Rated current
t1
• Duty =
x 100[%] ≤ 20% (90 to 170 VAC)
t1+t2
30% (170 to 264 VAC)
S8EX-BP050@@@ (50W)
S8EX-BP100@@@ (100W)
Overload Protection
• Internal parts may possibly deteriorate or be damaged if a
shortcircuited, overload or boost load state continues during
operation.
• Internal parts may possibly deteriorate or be damaged if the Power
Supply is used for applications with frequent inrush current or
overloading at the load end. Do not use the Power Supply for such
applications.
Charging a Battery
• t1 ≤ 10s
• Ip ≤ Rated boost current
• Iave ≤ Rated current × 70% (90 to 170 VAC)
S8EX-BP150@@@ (150W)
Rated current
(170 to 264 VAC)
t1
x 100[%] ≤ 10% (90 to 170 VAC)
t1+t2
20% (170 to 264 VAC)
• Duty =
• t1 ≤ 5s
• Ip ≤ Rated boost current
• Iave ≤ Rated current × 70% (85 to 170 VAC)
Rated current × 90% (170 to 264 VAC)
t1
• Duty =
x 100[%] ≤ 20%
t1+t2
S8EX-BP240@@@ (240W)
When connecting a battery at the load, connect an overcurrent
limiting circuit and overvoltage protection circuit.
Note: Make sure that the boost current meets the above conditions.
Consult with your OMRON representative if any other
conditions are required.
Ripple Noise Voltage
The specified standard for the ripple voltage noise was measured with
a measurement circuit that is based on JEITA standard RC-9131A.
+V
C1
C2
S8EX
Load
−V
150 mm
C1 : 100µF
C2 : 0.1µF
Coaxial cable
24
Oscilloscope
Frequency band:
100 MHz
MEMO
25
MEMO
26
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have
any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing
by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice
to change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Industrial Automation Company
Authorized Distributor:
Tokyo, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69-2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
© OMRON Corporation 2012 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
CSM_7_3_0416
Printed in Japan
0413 (0112)
Cat. No. T048-E1-04