New Product Switch Mode Power Supply S8EX (15, 30, 50, 100, 150, and 240-W Models) Newly Released High-capacity 240-W Models in S8EX-series Lineup Rated Output of 300 W for 200 VAC.* * From 170 to 264 VAC. New 240-W Models • Lineup of models with 24-, 36-, and 48-VDC output voltages. 15-W, 35-W, 50-W, 100-W, and 150-W Models • Lineup of models with from 5 to 48-VDC output voltages. All Models • Approved standards: UL60950-1, cUR CSA C22.2 No. 60950-1, EN 50178, and EN 60950-1 • Lineup includes open-frame models, models with chassis, and models with chassis and covers. • Wide-range power supply: 100 to 240 VAC • Complies with harmonic current standard in EN 61000-3-2 (50-W to 240-W models). • The top class in industry for compact size. • Boost current output (some models excluded). For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to Safety Precautions on page 22. Model Number Structure Model Number Legend Note: Not all combinations are possible. Refer to List of Models in Ordering Information on page 2. S8EX-@@@@@@@@-@@@-@@ 1 2 3 4 5 6 1. Power Boost Function Blank: None B: Power boost for output current 7 8 2. Power Factor Improvement Function N: None P: Power factor improvement function provided * * Harmonic current standard: EN 61000-3-2 compliant. 3. Power Ratings 015: 15 W 030: 30 W 050: 50 W 100: 100 W 150: 150 W 240: 240 W 4. Output Voltage 05: 5 V 12: 12 V 15: 15 V 24: 24 V 36: 36 V 48: 48 V 5. Configuration None: Open-frame L: With chassis LC: With chassis and cover 6. Option 1 None: Standard model CN1: XH connector (manufactured by J.S.T. Mfg. Co., Ltd.) * * This option is applicable only for 15-W models. 7. Option 2 None: Standard model R: Remote control * * This option is applicable only for 50-W, 100-W, 150-W, and 240-W models. * This option is applicable only for open-frame models. 8. Option 3 None: Standard model C: Coating (one side) * * This option is applicable only for open-frame models. 1 S8EX Ordering Information List of Models Note: For details on normal stock models, contact your nearest OMRON representative. Open frame Power ratings 15 W 30 W 50 W 100 W 150 W Output voltage 5V 12 V 15 V 24 V 48 V 5V 12 V 15 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V 24 V 240 W 36 V 48 V Output current 3A 1.3 A 1A 0.7 A 0.32 A 6A 2.5 A 2A 1.3 A 0.65 A 10 A 4.3 A 2.1 A 1.1 A 20 A 8.5 A 4.3 A 2.1 A 30 A 12.5 A 6.3 A 3.2 A 10 A (100 VAC) 12.5 A (200 VAC) 6.7 A (100 VAC) 8.4 A (200 VAC) 5 A (100 VAC) 6.3 A (200 VAC) Note: The input voltage is 100 to 240 VAC for all models. 2 Boost current 15 A 6.5 A 4.2 A 2.2 A --12.8 A 8.6 A 4.2 A --18.8 A 12.6 A 6.4 A Model S8EX-N01505 S8EX-N01512 S8EX-N01515 S8EX-N01524 S8EX-N01548 S8EX-N03005 S8EX-N03012 S8EX-N03015 S8EX-N03024 S8EX-N03048 S8EX-BP05005 S8EX-BP05012 S8EX-BP05024 S8EX-BP05048 S8EX-P10005 S8EX-BP10012 S8EX-BP10024 S8EX-BP10048 S8EX-P15005 S8EX-BP15012 S8EX-BP15024 S8EX-BP15048 20 A S8EX-BP24024 13.4 A S8EX-BP24036 10 A S8EX-BP24048 --- --- S8EX With chassis Power ratings 15 W 30 W 50 W 100 W 150 W Output voltage 5V 12 V 15 V 24 V 48 V 5V 12 V 15 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V 24 V 240 W 36 V 48 V Output current 3A 1.3 A 1A 0.7 A 0.32 A 6A 2.5 A 2A 1.3 A 0.65 A 10 A 4.3 A 2.1 A 1.1 A 20 A 8.5 A 4.3 A 2.1 A 30 A 12.5 A 6.3 A 3.2 A 10 A (100 VAC) 12.5 A (200 VAC) 6.7 A (100 VAC) 8.4 A (200 VAC) 5 A (100 VAC) 6.3 A (200 VAC) Boost current 15 A 6.5 A 4.2 A 2.2 A --12.8 A 8.6 A 4.2 A --18.8 A 12.6 A 6.4 A Model S8EX-N01505L S8EX-N01512L S8EX-N01515L S8EX-N01524L S8EX-N01548L S8EX-N03005L S8EX-N03012L S8EX-N03015L S8EX-N03024L S8EX-N03048L S8EX-BP05005L S8EX-BP05012L S8EX-BP05024L S8EX-BP05048L S8EX-P10005L S8EX-BP10012L S8EX-BP10024L S8EX-BP10048L S8EX-P15005L S8EX-BP15012L S8EX-BP15024L S8EX-BP15048L 20 A S8EX-BP24024L 13.4 A S8EX-BP24036L 10 A S8EX-BP24048L --- --- Note: The input voltage is 100 to 240 VAC for all models. 3 S8EX With chassis and cover Power ratings 15 W 30 W 50 W 100 W 150 W Output voltage 5V 12 V 15 V 24 V 48 V 5V 12 V 15 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V 24 V 240 W 36 V 48 V Output current 3A 1.3 A 1A 0.7 A 0.32 A 6A 2.5 A 2A 1.3 A 0.65 A 10 A 4.3 A 2.1 A 1.1 A 20 A 8.5 A 4.3 A 2.1 A 30 A 12.5 A 6.3 A 3.2 A 10 A (100 VAC) 12.5 A (200 VAC) 6.7 A (100 VAC) 8.4 A (200 VAC) 5 A (100 VAC) 6.3 A (200 VAC) Note: The input voltage is 100 to 240 VAC for all models. 4 Boost current 15 A 6.5 A 4.2 A 2.2 A --12.8 A 8.6 A 4.2 A --18.8 A 12.6 A 6.4 A Model S8EX-N01505LC S8EX-N01512LC S8EX-N01515LC S8EX-N01524LC S8EX-N01548LC S8EX-N03005LC S8EX-N03012LC S8EX-N03015LC S8EX-N03024LC S8EX-N03048LC S8EX-BP05005LC S8EX-BP05012LC S8EX-BP05024LC S8EX-BP05048LC S8EX-P10005LC S8EX-BP10012LC S8EX-BP10024LC S8EX-BP10048LC S8EX-P15005LC S8EX-BP15012LC S8EX-BP15024LC S8EX-BP15048LC 20 A S8EX-BP24024LC 13.4 A S8EX-BP24036LC 10 A S8EX-BP24048LC --- --- S8EX Ratings, Characteristics, and Functions Power ratings Item Efficiency (Typ.) 5V 12 V 15 V 24 V 48 V 100 VAC input 74% 77% 80% 80% 83% 200 VAC input 74% 77% 78% 78% 82% 100 to 240 VAC (allowable voltage: 85 to 264 VAC or 120 to 370 VDC *6) Voltage *1 Frequency *1 Current (Typ.) Input Leakage current Inrush current (Typ.) Output 15 W Output voltage 50/60 Hz (47 to 450 Hz) 100 VAC input 0.4 A 200 VAC input 0.25 A 100 VAC input 0.5 mA max. 200 VAC input 1 mA max. 100 VAC input 15 A (for a cold start at 25°C) 200 VAC input 30 A (for a cold start at 25°C) Voltage adjustment range *2 ±10% (with V. ADJ) Ripple *3 150 mV max. Input variation influence 0.5% max. (with 85 to 264 VAC input at 100% load) Load variation influence 2% max. (0 to 100% load, rated input voltage) Temperature variation influence 0.05%/°C max. Startup time (Typ.) 100 VAC input 800 ms Hold time (Typ.) 100 VAC input 20 ms Overload protection Additional Overvoltage protection *4 functions Series operation 240 mV max. 300 mV max. 480 mV max. 960 mV max. 1.5% max. (0 to 100% load, rated input voltage) 105% to 160% of rated current, voltage drop, intermittent, and automatic reset Yes Yes (For up to two Power Supplies; external diodes required.) Parallel operation No (However, backup operation is possible; external diodes required.) Ambient operating temperature −10 to 70°C (Derating is required according to the temperature.) (with no icing or condensation) Storage temperature −25 to 75°C (with no icing or condensation) Ambient operating humidity 25% to 85% (Storage humidity: 25% to 90%) Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs; Cutoff current: 10 mA) 2.0 kVAC for 1 min. (between all inputs and PE; Cutoff current: 10 mA) 1.0 kVAC for 1 min. (between all outputs and PE; Cutoff current: 20 mA) Insulation resistance 100 MΩ min. (between all outputs and all inputs/PE terminal) at 500 VDC Vibration resistance 10 to 55 Hz, 19.6 m/s2 (2 G) for 1 h each in X, Y, and Z directions Shock resistance 196.1 m/s2, 3 times each in ±X, ±Y, ±Z directions EMI Other EMS Conducted Emissions Conforms to EN 55011 Group 1 Class B *7 Radiated Emissions Conforms to EN 55011 Group 1 Class B *7 Electrostatic Discharge Conforms to EN61000-4-2 Radiated Electromagnetic Field Conforms to EN61000-4-3 Electrical Conforms to EN61000-4-4 Fast Transient/Burst Surge Conforms to EN61000-4-5 Conducted Disturbance Conforms to EN61000-4-6 Voltage Dips/Short Interruptions Conforms to EN61000-4-11 Approved standards UL UR: UL 60950-1 (Recognition) cUR: CSA C22.2 No. 60950-1 EN: EN50178, EN60950-1 SEMI SEMI F47-0706 (at 200 VAC) Weight *5 70 g max. (without chassis and cover) *1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. *2. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by +10% of the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged. *3. Rated input voltage: 100 or 200 VAC at 100% load. The measurement method is based on JEITA standard RC-9131A. For details, refer to Ripple Noise Voltage on page 24. *4. To reset the protection after power is shut off, turn OFF the input power for three minutes or longer and then turn it back ON. *5. The weight is for an open-frame model. *6. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). *7. Class B compliance was met with an aluminum plate placed under the Power Supply. 5 S8EX Power ratings Item Output voltage Efficiency (Typ.) Current (Typ.) Leakage current Inrush current (Typ.) 12 V 15 V 24 V 48 V 77% 82% 83% 85% 85% 200 VAC input 79% 83% 83% 86% 86% 100 to 240 VAC (allowable voltage: 85 to 264 VAC, 120 to 370 VDC *6) Frequency *1 Input 5V 100 VAC input Voltage *1 Output 30 W 50/60 Hz (47 to 450 Hz) 100 VAC input 0.7 A 200 VAC input 0.4 A 100 VAC input 0.5 mA max. 200 VAC input 1mA max. 100 VAC input 15 A (for a cold start at 25°C) 200 VAC input 30 A (for a cold start at 25°C) Voltage adjustment range *2 ±10% (with V. ADJ) Ripple *3 150 mV max. Input variation influence 0.5% max. (with 85 to 264 VAC input at 100% load) Load variation influence 2% max. (0 to 100% load, rated input voltage) Temperature variation influence 0.05%/°C max. Startup time (Typ.) 100 VAC input 800 ms Hold time (Typ.) 100 VAC input 20 ms Overload protection Additional Overvoltage protection *4 functions Series operation 240 mV max. 300 mV max. 480 mV max. 960 mV max. 1.5% max. (0 to 100% load, rated input voltage) 105% to 160% of rated current, voltage drop, intermittent, automatic reset Yes Yes (For up to two Power Supplies; external diodes required.) Parallel operation No (However, backup operation is possible; external diodes required.) Ambient operating temperature −10 to 70°C (Derating is required according to the temperature.) (with no icing or condensation) Storage temperature −25 to 75°C (with no icing or condensation) Ambient operating humidity 25% to 85% (Storage humidity: 25% to 90%) Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs; Cutoff current: 10 mA) 2.0 kVAC for 1 min. (between all inputs and PE; Cutoff current: 10 mA) 1.0 kVAC for 1 min. (between all outputs and PE; Cutoff current: 20 mA) Insulation resistance 100 MΩ min. (between all outputs and all inputs/PE terminal) at 500 VDC Vibration resistance 10 to 55 Hz, 19.6 m/s2 (2 G) for 1 h each in X, Y, and Z directions Shock resistance 196.1 m/s2, 3 times each in ±X, ±Y, ±Z directions EMI Other EMS Conducted Emissions Conforms to EN 55011 Group 1 Class B *7 Radiated Emissions Conforms to EN 55011 Group 1 Class B *7 Electrostatic Discharge Conforms to EN61000-4-2 Radiated Electromagnetic Field Conforms to EN61000-4-3 Electrical Conforms to EN61000-4-4 Fast Transient/Burst Surge Conforms to EN61000-4-5 Conducted Disturbance Conforms to EN61000-4-6 Voltage Dips/Short Interruptions Conforms to EN61000-4-11 Approved standards UL UR: UL 60950-1 (Recognition) cUR: CSA C22.2 No. 60950-1 EN: EN50178, EN60950-1 SEMI SEMI F47-0706 (at 200 VAC) Weight *5 110 g max. (without chassis and cover) *1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. *2. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by +10% of the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged. *3. Rated input voltage: 100 or 200 VAC at 100% load. The measurement method is based on JEITA standard RC-9131A. For details, refer to Ripple Noise Voltage on page 24. *4. To reset the protection after power is shut off, turn OFF the input power for three minutes or longer and then turn it back ON. *5. The weight is for an open-frame model. *6. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). *7. Class B compliance was met with an aluminum plate placed under the Power Supply. 6 S8EX Power ratings Item Efficiency (Typ.) 100 VAC input 200 VAC input Voltage *1 Current (Typ.) 24 V 48 V 79% 83% 82% 82% 81% 86% 85% 85% 50/60 Hz (47 to 63 Hz) 100 VAC input 200 VAC input 0.65 A 0.35 A 0.9 min. Harmonic current emissions Conforms to EN 61000-3-2 Class A. Inrush current (Typ.) 100 VAC input 0.5 mA max. 200 VAC input 1 mA max. 100 VAC input 14.1 A max. (for a cold start at 25°C) 200 VAC input 28.3 A max. (for a cold start at 25°C) Voltage adjustment range *2 ±10% (with V. ADJ) Ripple *3 150 mV max. Input variation influence 0.5% max. (with 85 to 264 VAC input at 100% load) Load variation influence 2% max. (0 to 100% load, rated input voltage) Temperature variation influence 0.05%/°C max. Startup time (Typ.) 100 VAC input 440 ms 460 ms 500 ms 460 ms Hold time (Typ.) 100 VAC input 25 ms 20 ms 23 ms 22 ms Overload protection 240 mV max. 480 mV max. 960 mV max. 1.5% max. (0 to 100% load, rated input voltage) 100% to 110% of rated load current, voltage drop, intermittent, automatic reset Overvoltage protection *4 Additional Series operation functions Parallel operation Yes Yes (For up to two Power Supplies.) No (However, backup operation is possible; external diodes required.) Remote control Yes (Only for models with remote control option.) Ambient operating temperature −10 to 70°C (Derating is required according to the temperature.) (with no icing or condensation) Storage temperature −25 to 75°C (with no icing or condensation) Ambient operating humidity 25% to 85% (Storage humidity: 25% to 90%) Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs; Cutoff current: 10 mA) 2.0 kVAC for 1 min. (between all inputs and PE; Cutoff current: 10 mA) 1.0 kVAC for 1 min. (between all outputs and PE; Cutoff current: 20 mA) Insulation resistance 100 MΩ min. (between all outputs and all inputs/PE terminal) at 500 VDC Vibration resistance 10 to 55 Hz, 19.6 m/s2 (2 G) for 1 h each in X, Y, and Z directions 196.1 m/s2, 3 times each in ±X, ±Y, ±Z directions Shock resistance Other 12 V Power factor (rate, 100% load) Leakage current Output 5V 100 to 240 VAC (allowable voltage: 85 to 264 VAC, 120 to 370 VDC *6) Frequency *1 Input 50 W Output voltage EMI EMS Conducted Emissions Conforms to EN 55011 Group 1 Class B *7 Radiated Emissions Conforms to EN 55011 Group 1 Class B *7 Electrostatic Discharge Conforms to EN61000-4-2 Radiated Electromagnetic Field Conforms to EN61000-4-3 Electrical Fast Transient/Burst Conforms to EN61000-4-4 Surge Conforms to EN61000-4-5 Conducted Disturbance Conforms to EN61000-4-6 Voltage Dips/Short Interruptions Conforms to EN61000-4-11 Approved standards UL UR: UL 60950-1 (Recognition) cUR: CSA C22.2 No. 60950-1 EN: EN50178, EN60950-1 SEMI SEMI F47-0706 (at 200 VAC) Weight *5 150 g max. (without chassis and cover) *1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. *2. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by +10% of the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged. *3. Rated input voltage: 100 or 200 VAC at 100% load. The measurement method is based on JEITA standard RC-9131A. For details, refer to Ripple Noise Voltage on page 24. *4. To reset the protection after power is shut off, turn OFF the input power for three minutes or longer and then turn it back ON. *5. The weight is for an open-frame model. *6. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). *7. Class B compliance was met with an aluminum plate placed under the Power Supply. 7 S8EX Power ratings Item Efficiency (Typ.) 100 VAC input 200 VAC input Voltage *1 Current (Typ.) 24 V 48 V 81% 82% 84% 84% 84% 85% 86% 86% 50/60 Hz (47 to 63 Hz) 100 VAC input 200 VAC input 1.3 A 0.65 A 0.9 min. Harmonic current emissions Conforms to EN 61000-3-2 Class A. Inrush current (Typ.) 100 VAC input 0.5 mA max. 200 VAC input 1 mA max. 100 VAC input 14.1 A max. (for a cold start at 25°C) 200 VAC input 28.3 A max. (for a cold start at 25°C) Voltage adjustment range *2 ±10% (with V. ADJ) Ripple *3 150 mV max. Input variation influence 0.5% max. (with 85 to 264 VAC input at 100% load) Load variation influence 2% max. (0 to 100% load, rated input voltage) Temperature variation influence 0.05%/°C max. Startup time (Typ.) 100 VAC input 480 ms 530 ms 540 ms 650 ms Hold time (Typ.) 100 VAC input 24 ms 21 ms 22 ms 24 ms 240 mV max. 480 mV max. 960 mV max. 1.5% max. (0 to 100% load, rated input voltage) 12-V, 24-V, or 48-V model: 100% to 110% of power boost for output current, voltage drop, intermittent, automatic reset 5-V model: 105% to 160% of rated current, voltage drop, intermittent, automatic reset Overload protection Additional Overvoltage protection *4 functions Series operation Yes Yes (For up to two Power Supplies.) Parallel operation No (However, backup operation is possible; external diodes required.) Remote control Yes (Only for models with remote control option.) Ambient operating temperature −10 to 70°C (Derating is required according to the temperature.) (with no icing or condensation) Storage temperature −25 to 75°C (with no icing or condensation) Ambient operating humidity 25% to 85% (Storage humidity: 25% to 90%) Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs; Cutoff current: 10 mA) 2.0 kVAC for 1 min. (between all inputs and PE; Cutoff current: 10 mA) 1.0 kVAC for 1 min. (between all outputs and PE; Cutoff current: 20 mA) Insulation resistance 100 MΩmin. (between all outputs and all inputs/PE terminal) at 500 VDC Vibration resistance 10 to 55 Hz, 19.6 m/s2 (2 G) for 1 h each in X, Y, and Z directions 196.1 m/s2, 3 times each in ±X, ±Y, ±Z directions Shock resistance Other 12 V Power factor (rate, 100% load) Leakage current Output 5V 100 to 240 VAC (allowable voltage: 85 to 264 VAC, 120 to 370 VDC *6) Frequency *1 Input 100 W Output voltage EMI EMS Conducted Emissions Conforms to EN 55011 Group 1 Class B *7 Radiated Emissions Conforms to EN 55011 Group 1 Class B *7 Electrostatic Discharge Conforms to EN61000-4-2 Radiated Electromagnetic Field Conforms to EN61000-4-3 Electrical Fast Transient/Burst Conforms to EN61000-4-4 Surge Conforms to EN61000-4-5 Conducted Disturbance Conforms to EN61000-4-6 Voltage Dips/Short Interruptions Conforms to EN61000-4-11 Approved standards UL UR: UL 60950-1 (Recognition) cUR: CSA C22.2 No. 60950-1 EN: EN50178, EN60950-1 SEMI SEMI F47-0706 (at 200 VAC) Weight *5 265 g max. (without chassis and cover) *1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. *2. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by +10% of the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged. *3. Rated input voltage: 100 or 200 VAC at 100% load. The measurement method is based on JEITA standard RC-9131A. For details, refer to Ripple Noise Voltage on page 24. *4. To reset the protection after power is shut off, turn OFF the input power for three minutes or longer and then turn it back ON. *5. The weight is for an open-frame model. *6. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). *7. Class B compliance was met with an aluminum plate placed under the Power Supply. 8 S8EX Power ratings Item Efficiency (Typ.) 100 VAC input 200 VAC input Voltage *1 Current (Typ.) 24 V 48 V 84% 83% 84% 85% 87% 86% 87% 88% 50/60 Hz (47 to 63 Hz) 100 VAC input 200 VAC input 1.9 A 0.95 A 0.9 min. Harmonic current emissions Conforms to EN 61000-3-2 Class A. Inrush current (Typ.) 100 VAC input 0.5 mA max. 200 VAC input 1 mA max. 100 VAC input 14.1 A max. (for a cold start at 25°C) 200 VAC input 28.3 A max. (for a cold start at 25°C) Voltage adjustment range *2 ±10% (with V. ADJ) Ripple *3 150 mV max. Input variation influence 0.5% max. (with 85 to 264 VAC input at 100% load) Load variation influence 2% max. (0 to 100% load, rated input voltage) Temperature variation influence 0.05%/°C max. Startup time (Typ.) 100 VAC input 450 ms 660 ms 660 ms 690 ms Hold time (Typ.) 100 VAC input 25 ms 20 ms 21 ms 20 ms 240 mV max. 480 mV max. 960 mV max. 1.5% max. (0 to 100% load, rated input voltage) 12-V, 24-V, or 48-V model: 100% to 110% of power boost for output current, voltage drop, intermittent, automatic reset 5-V model: 105% to 160% of rated current, voltage drop, intermittent, automatic reset Overload protection Additional Overvoltage protection *4 functions Series operation Yes Yes (For up to two Power Supplies.) Parallel operation No (However, backup operation is possible; external diodes required.) Remote control Yes (Only for models with remote control option.) Ambient operating temperature −10 to 70°C (Derating is required according to the temperature.) (with no icing or condensation) Storage temperature −25 to 75°C (with no icing or condensation) Ambient operating humidity 25% to 85% (Storage humidity: 25% to 90%) Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs; Cutoff current: 10 mA) 2.0 kVAC for 1 min. (between all inputs and PE; Cutoff current: 10 mA) 1.0 kVAC for 1 min. (between all outputs and PE; Cutoff current: 20 mA) Insulation resistance 100 MΩ min. (between all outputs and all inputs/PE terminal) at 500 VDC Vibration resistance 10 to 55 Hz, 19.6 m/s2 (2 G) for 1 h each in X, Y, and Z directions 196.1 m/s2, 3 times each in ±X, ±Y, ±Z directions Shock resistance Other 12 V Power factor (rate, 100% load) Leakage current Output 5V 100 to 240 VAC (allowable voltage: 85 to 264 VAC, 120 to 370 VDC *6) Frequency *1 Input 150 W Output voltage EMI EMS Conducted Emissions Conforms to EN 55011 Group 1 Class B *7 Radiated Emissions Conforms to EN 55011 Group 1 Class B *7 Electrostatic Discharge Conforms to EN61000-4-2 Radiated Electromagnetic Field Conforms to EN61000-4-3 Electrical Fast Transient/Burst Conforms to EN61000-4-4 Surge Conforms to EN61000-4-5 Conducted Disturbance Conforms to EN61000-4-6 Voltage Dips/Short Interruptions Conforms to EN61000-4-11 Approved standards UL UR: UL 60950-1 (Recognition) cUR: CSA C22.2 No. 60950-1 EN: EN50178, EN60950-1 SEMI SEMI F47-0706 (at 200 VAC) Weight *5 315 g max. (without chassis and cover) *1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. *2. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by +10% of the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged. *3. Rated input voltage: 100 or 200 VAC at 100% load. The measurement method is based on JEITA standard RC-9131A. For details, refer to Ripple Noise Voltage on page 24. *4. To reset the protection after power is shut off, turn OFF the input power for three minutes or longer and then turn it back ON. *5. The weight is for an open-frame model. *6. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). *7. Class B compliance was met with an aluminum plate placed under the Power Supply. 9 S8EX Power ratings Item Efficiency (Typ.) 100 VAC input 200 VAC input Voltage *1 Current (Typ.) 87% 90% 90% 90% 50/60 Hz (47 to 63 Hz) 100 VAC input 2.9 A (for 240-W output) 200 VAC input 1.5 A (for 240-W output) 1.8 A (for 300-W output) 0.9 min. Conforms to EN 61000-3-2 Class A. 100 VAC input 0.5 mA max. 200 VAC input 1.0 mA max. 100 VAC input 14 A (for a cold start at 25°C) 200 VAC input 28 A (for a cold start at 25°C) Voltage adjustment range *2 ±10% (with V. ADJ) Ripple *3 480 mV max. Input variation influence 0.5% max. Load variation influence 1.5% max. Temperature variation influence 0.05%/°C max. Startup time (Typ.) Hold time (Typ.) 48 V 87% Harmonic current emissions Inrush current (Typ.) 720 mV max. 100 VAC input 460 ms 200 VAC input 330 ms 100 VAC input 20 ms (for output power of 240 W) 200 VAC input 20 ms (for output power of 240 W) 16 ms (for output power of 300 W) 960 mV max. 100% or higher of power boost for output current, voltage drop, automatic reset Power shut off if 130% or higher of rated output current continues for approx. 5 s Reset by input reset (OFF time: 3 min min.) Overload protection *4 Overvoltage protection *4 Additional functions Series operation Parallel operation Yes Yes (For up to two Power Supplies; external diodes are required.) No (However, backup operation is possible; external diodes required.) Remote control Yes (Only for models with remote control option.) Undervoltage alarm output Yes (open-collector output, 30 VDC max., 50 mA max.) Ambient operating temperature −10 to 70°C (Derating is required according to the temperature.) (with no icing or condensation) Storage temperature −25 to 75°C (with no icing or condensation) Ambient operating humidity 25% to 85% Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs; Cutoff current: 10 mA) 2.0 kVAC for 1 min. (between all inputs and PE; Cutoff current: 10 mA) 1.0 kVAC for 1 min. (between all outputs and PE; Cutoff current: 20 mA) Insulation resistance 100 MΩ min. (between all outputs and all inputs/PE terminal) at 500 VDC (at room temperature 25°C and humidity 60%) Vibration resistance No abnormality after 10 to 55 Hz, 19.6 m/s2 (2 G) for 1 h each in X, Y, and Z directions. 196.1 m/s2, 3 times each in ±X, ±Y, ±Z directions Shock resistance Other 36 V 87% Power factor (rate, 100% load) Leakage current Output 24 V 100 to 240 VAC (allowable voltage: 85 to 264 VAC, 120 to 370 VDC *6) Frequency *1 Input 240 W (300 W) Output voltage EMI EMS Conducted Emissions Conforms to EN 55011 Group 1 Class B *7 Radiated Emissions Conforms to EN 55011 Group 1 Class B *7*8 Electrostatic Discharge Conforms to EN61000-4-2 Radiated Electromagnetic Field Conforms to EN61000-4-3 Electrical Fast Transient/Burst Conforms to EN61000-4-4 Surge Conforms to EN61000-4-5 Conducted Disturbance Conforms to EN61000-4-6 Voltage Dips/Short Interruptions Conforms to EN61000-4-11 Approved standards UL UR: UL 60950-1 (Recognition) cUR: CSA C22.2 No. 60950-1 EN: EN50178, EN60950-1 SEMI SEMI F47-0706 (at 200 VAC) Weight *5 515 g (without chassis and cover) *1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. *2. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by +10% of the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged. *3. Rated input voltage: 100 or 200 VAC at 100% load. The measurement method is based on JEITA standard RC-9131A. For details, refer to Ripple Noise Voltage on page 24. *4. To reset the protection after power is shut off, turn OFF the input power for three minutes or longer and then turn it back ON. *5. The weight is for an open-frame model. *6. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). *7. Noise values depend on the wiring methods. Class B compliance was met with an aluminum plate placed under the Power Supply. *8. Insert filters (ZCAT3035-1330 manufactured by TDK Corporation) in the input and output lines to reduce noise. 10 S8EX Connections Block Diagrams S8EX-N015@@ (15 W) S8EX-N030@@ (30 W) AC(L) +V Fuse* INPUT Noise filter DC OUTPUT AC(N) -V Inrush Smoothing current circuit protection Rectifier *15 W: 2.5 A 30 W: 4.0A Rectifier/ Smoothing circuit Drive control Circuit Overcurrent detection circuit Voltage detection Overvoltage detection circuit Photocoupler S8EX-BP050@@ (50 W) S8EX-@P100@@ (100 W) S8EX-@P150@@ (150 W) +V AC(L) Fuse* INPUT Noise filter DC OUTPUT AC(N) -V Rectifier * 50 W: 4.0 A 100 W: 6.3 A 150 W: 8.0 A Inrush Harmonic current Smoothing current circuit suppression protection Rectifier/ Smoothing circuit Drive control Circuit Overcurrent detection circuit Voltage detection Overvoltage detection circuit Photocoupler +RC Remote control Photocoupler -RC Only for models with remote control option. S8EX-BP240@@ (240 W) AC(L) Fuse: 10 A INPUT +V Noise filter DC OUTPUT AC(N) -V Rectifier Harmonic current suppression Inrush current protection Smoothing circuit Rectifier/ Smoothing circuit Drive control Circuit DC LOW OUT Overcurrent detection circuit Voltage detection Undervoltage detection output Overvoltage detection circuit Photocoupler +RC Remote control Photocoupler -RC Only for models with remote control option 11 S8EX Construction and Nomenclature Nomenclature S8EX-N015@@@@ No. Name Function 6 2 1 CN51 1 Input Terminals (L), (N) Connect the input lines to these terminals. *1 2 Protective Earth Terminal (PE) Connect the ground line to these terminals. *2 3 DC Output Terminals (−V), (+V) Connect the load lines to these terminals. 6 4 Output Voltage Adjuster (V. ADJ) It is possible to increase or decrease the output voltage. 3 5 Chassis 4 6 Cover 7 Undervoltage alarm output collector terminal (DC LOW) 8 Undervoltage alarm output emitter terminal (DC LOW) 9 Remote control +RC terminal *3 10 Remote control −RC terminal *3 3 4 CN1 5 S8EX-N015@@@@-CN1 2 1 CN51 CN1 5 S8EX-N030@@@@ 6 2 1 CN51 3 4 CN1 S8EX-BP050@@@ 9 10 4 1 Wire for remote control. *1. The fuse is located on the (L) side. It is NOT user-replaceable. For a DC power input, connect the low side to the positive (+) terminal. Safety standards do not apply for a DC input. *2. This is the protective earth terminal specified in the safety standards. Always ground this terminal. *3. Only for models with remote control option. 5 2 Output a signal when a low output voltage is detected. 3 CN1 CN51 5 6 S8EX-@P100@@@ 6 5 CN51 2 3 1 4 9 10 CN1 S8EX-@P150@@@ 5 CN52 2 1 3 CN1 CN51 4 9 10 6 S8EX-BP240@@@@ 6 5 CN51 3 2 1 9 10 4 7 8 CN1 Input and Output Connectors Housing B3P5-VH(LF)(SN) VHR-5N Input side All models Output side S8EX-N015@@@@ S8EX-N030@@@@ S8EX-BP050@@@ CN51 B4P-VH(LF)(SN) VHR-4N Output side S8EX-N015@@@@-CN1 CN51 B4B-XH XHP-4 Output side S8EX-@P100@@@ CN51 B8P-VH(LF)(SN) VHR-8N S8EX-@P150@@@ CN51 B6P-VH(LF)(SN) VHR-6N CN52 B7P-VH(LF)(SN) VHR-7N S8EX-BP240@@@@ CN51 B8P-VH(LF)(SN) VHR-8N Output side Output side Output side Manufacturer CN1 Applicable connector Applicable crimp tool YC-160R Reel: SVH-21T-P1.1 Bulk: BVH-21T-P1.1 Reel: SXH-001T-P0.6 Bulk: BXH-001T-P0.6 YC-160R YC-111R YC-160R Reel: SVH-21T-P1.1 Bulk: BVH-21T-P1.1 J.S.T. Mfg. Co., Ltd. Note: The female connectors that are required for wiring are not provided with the Power Supply. 12 Terminals YC-160R YC-160R YC-160R S8EX Special Harnesses for S8EX-Series Applicable Models and Harness Models Applicable models (S8EX-Series) Connected to 15 W 30 W 50 W 100 W 150 W 240 W OK OK OK OK OK OK OK OK OK Input side and output side Input side Output side OK OK OK OK OK OK OK OK S82Y-EX01HO-01 Output (±), common S82Y-EX02HO-01 Output side Output side Output side + S82Y-EX04HO-01 OK Output side Output side − S82Y-EX05HO-01 OK Input side S82Y-EX01HI-10 Output side OK* Output side OK OK 1 S82Y-EX03HO-01 OK OK Qty S82Y-EX01HI-01 Output side OK* OK Model number Output (+, −) S82Y-EX01HO-10 Output (±), common S82Y-EX02HO-10 Output side 10 S82Y-EX03HO-10 OK Output side Output side + S82Y-EX04HO-10 OK Output side Output side − S82Y-EX05HO-10 * Application is possible only to the S8EX-CN1. Harness Specifications Model number S82Y-EX01HI-@@ S82Y-EX01HO-@@ S82Y-EX02HO-@@ S82Y-EX03HO-@@ Connector structure Housing Model: VHR-5N Manufacturer: J.S.T. Mfg. Co., Ltd. Pins Model: SVH-21T-P1.1 Manufacturer: J.S.T. Mfg. Co., Ltd. Housing Model: VHR-4N Manufacturer: J.S.T. Mfg. Co., Ltd. Pins Model: SVH-21T-P1.1 Manufacturer: J.S.T. Mfg. Co., Ltd. Housing Model: XHP-4 Manufacturer: J.S.T. Mfg. Co., Ltd. Pins Model: SXH-001T-P0.6 Manufacturer: J.S.T. Mfg. Co., Ltd. Housing Model: VHR-8N Manufacturer: J.S.T. Mfg. Co., Ltd. Pins Model: SVH-21T-P1.1 Manufacturer: J.S.T. Mfg. Co., Ltd. Shape 1 2 3 4 5 S82Y-EX04HO-@@ S82Y-EX05HO-@@ Housing Model: VHR-7N Manufacturer: J.S.T. Mfg. Co., Ltd. Pins Model: SVH-21T-P1.1 Manufacturer: J.S.T. Mfg. Co., Ltd. Pin Wire AWG Color Length: L (mm) 1 UL1015 18 Black 500 2 3 L +50 −0 1 2 3 4 +50 L −0 1 2 3 4 +50 L −0 1 2 3 4 5 6 7 8 L +50 −0 Housing Model: VHR-6N Manufacturer: J.S.T. Mfg. Co., Ltd. Pins Model: SVH-21T-P1.1 Manufacturer: J.S.T. Mfg. Co., Ltd. Applicable wires 1 2 3 4 5 6 L +50 −0 1 2 3 4 5 6 7 L +50 −0 NC UL1015 18 4 White 500 NC 5 UL1015 18 Green 500 Pin Wire AWG Color Length: L (mm) 1 UL1015 18 Black 500 2 UL1015 18 Black 500 3 UL1015 18 Red 500 4 UL1015 18 Red 500 Pin Wire AWG Color Length: L (mm) 1 UL1007 22 Black 500 2 UL1007 22 Black 500 3 UL1007 22 Red 500 4 UL1007 22 Red 500 Pin Wire AWG Color Length: L (mm) 1 UL1015 18 Black 500 2 UL1015 18 Black 500 3 UL1015 18 Black 500 4 UL1015 18 Black 500 5 UL1015 18 Red 500 6 UL1015 18 Red 500 7 UL1015 18 Red 500 8 UL1015 18 Red 500 Pin Wire AWG Color Length: L (mm) 1 UL1015 18 Red 500 2 UL1015 18 Red 500 3 UL1015 18 Red 500 4 UL1015 18 Red 500 5 UL1015 18 Red 500 6 UL1015 18 Red 500 Pin Wire AWG Color Length: L (mm) 1 UL1015 18 Black 500 2 UL1015 18 Black 500 3 UL1015 18 Black 500 4 UL1015 18 Black 500 5 UL1015 18 Black 500 6 UL1015 18 Black 500 7 UL1015 18 Black 500 13 S8EX Chassis cover option Applicable models Model number 15W S82Y-EX030LC 30W 50W S82Y-EX050LC 100W S82Y-EX100LC 150W S82Y-EX150LC 240W S82Y-EX240LC Engineering Data Derating Curves (Standard Mounting) Open-frame Models and Models with Chassis (15 W) Models with Chassis and Cover (15 W) Load 120 rate (%) 100 Load 120 rate (%) 100 80 80 60 60 40 40 20 0 −10 20 Mounting method A, B, C, and D Mounting method E and F 0 10 20 30 40 50 60 70 80 Ambient Temperature (°C) Open-frame Models and Models with Chassis (30 W) 0 −10 Load 120 rate (%) 100 80 80 60 60 40 40 0 −10 Mounting method B Mounting method A, C, D, and E Mounting method F 0 10 20 30 40 50 60 0 10 20 30 Mounting method B Mounting method A, C, D, and E Mounting method F 20 70 80 0 −10 0 10 20 30 Ambient Temperature (°C) Open-frame Models (50W) 40 50 60 70 80 Ambient Temperature (°C) Models with Chassis (50 W) Models with Chassis and Cover (50W) Load 120 rate (%) 100 Load 120 rate (%) 100 Load 120 rate (%) 100 80 80 80 60 60 60 40 0 -10 40 40 Mounting method A, B, and C Mounting method D Mounting method E Mounting method F 20 14 40 50 60 70 80 Ambient Temperature (°C) Models with Chassis and Cover (30 W) Load 120 rate (%) 100 20 Mounting method A, B, C, and D Mounting method E and F 0 10 20 30 40 50 60 70 80 Ambient Temperature (°C) Mounting method A, B, and C Mounting method D Mounting method E Mounting method F 20 0 −10 0 10 20 30 40 50 60 70 80 Ambient Temperature (°C) Mounting method A, B, and C Mounting method D Mounting method E Mounting method F 20 0 -10 0 10 20 30 40 50 60 70 80 Ambient Temperature (°C) S8EX Open-frame Models (100W) Models with Chassis (100 W) Load 120 rate (%) 100 Models with Chassis and Cover (100W) Load 120 rate (%) 100 Load 120 rate (%) 100 80 80 85 85 80 75 70 75 70 60 40 Mounting method A and B Mounting method C and E Mounting method D Mounting method F 20 0 -10 0 10 20 30 60 60 40 40 Mounting method A and B Mounting method C and E Mounting method D and F 20 0 −10 40 50 60 70 80 Ambient Temperature (°C) Open-frame Models (150 W) 0 10 20 30 Mounting method A and B Mounting method C and E Mounting method D Mounting method F 20 40 50 60 70 80 Ambient Temperature (°C) Models with Chassis (150 W) 0 -10 0 10 20 30 40 50 60 70 80 Ambient Temperature (°C) Models with Chassis and Cover (150 W) Load 120 rate (%) 100 Load 120 rate (%) 100 Load 120 rate (%) 100 80 80 80 85 75 70 60 60 40 60 40 Mounting method A and B Mounting method C and E Mounting method D Mounting method F 20 0 -10 0 10 20 30 40 Mounting method A and B Mounting method C and E Mounting method D Mounting method F 20 40 50 60 70 80 Ambient Temperature (°C) Open-frame Models and Models with Chassis (240 W) Load 120 rate (%) 100 0 -10 10 20 30 40 50 60 70 80 Ambient Temperature (°C) 0 -10 0 10 20 30 40 50 60 70 80 Ambient Temperature (°C) Models with Chassis and Cover (240W) Load 120 rate (%) 100 85 85 80 80 75 70 75 70 60 60 40 40 Mounting method A Mounting method B and C Mounting method E Mounting method D and F 20 0 −10 0 Mounting method A and B Mounting method C and E Mounting method D Mounting method F 20 0 10 20 30 Mounting method A (Standard mounting method) Mounting method A Mounting method B and C Mounting method E Mounting method D and F 20 0 −10 40 50 60 70 80 Ambient Temperature (°C) Mounting method B 0 10 20 Mounting method C 30 40 50 60 70 80 Ambient Temperature (°C) Mounting method D Mounting method F * Mounting method E CN1 FIN CN1 CN1 * CN1 * * CN1 FIN * * * CN1 * UL certification has not been obtained for 240-W models. Note: 1. Use a metal sheet* for the mounting surface. 2. Refer to Ambient Operating and Storage Environments on page 22. 3. A natural convection system is used for derating. Mount the Power Supply so that air convection will occur around it. 15 S8EX Input Voltage Derating Curve Overvoltage Protection For 50, 100, 150, and 240-W models, check the derating characteristics for the input voltage before using the Power Supply. Consider the possibility of an overvoltage and design the system so that the load will not be subjected to an excessive voltage even if the feedback circuit in the power supply fails. When an excessive voltage that is approximately 130% of the rated voltage or more is output, the output voltage is shut OFF, preventing damage to the load due to overvoltage. Reset the input power by turning it OFF for at least three minutes and then turning it back ON again. Load rate (%) 100 90 85 Output voltage (V) Reference Graph 90 Input voltage (VAC) Overload Protection The overload protection circuit will automatically reduce the output voltage for short circuits and overcurrents to protect the Power Supply from short-circuit currents and overcurrents. Note: Refer to Overload Protection on page 24. Rated output Voltage Overvoltage protection Operating Variable range 15 to 150-W Models When the output current falls within the rated range, the overload protection function is automatically cleared. Reference Graphs Models without Power Boost Function Intermittent operation Output voltage (V) Output voltage (V) Models with Power Boost Function 0V Note: Do not turn ON the power again until the cause of the overvoltage has been removed. Inrush Current, Startup Time, Output Hold Time Input ON Input OFF AC input voltage Intermittent operation Inrush current on input application AC input current 0 Maximum boost current 0 Rated current 96.5% 90% 240-W Models The output will be shut off if an output of 310 W or higher continues for approximately 5 seconds. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON. Reference Graph Rated voltage Overcurrent Curve Maximum boost current 16 Output voltage Startup time Hold time Note: A maximum startup time of 1,000 ms is required. Construct a system configuration that considers the startup time of other devices. S8EX Remote Control Function (S8EX-@@@@@@@@@-R only) Undervoltage Alarm Function (240 W Only) This function is to turn ON/OFF the output by applying a voltage to the remote control connector from a DC Power Supply (external power supply) other than this Power Supply. Built-in resistance Ri (Ω) Voltage between +RC and −RC (V) Output ON Output OFF 4.5 to 12.5 0 to 0.5 1kΩ R Note 1 External power supply (SELV output) Inrush current (mA) 20 max. Inside the power supply Switch +RC 1 Ri When a drop of output voltage is detected, the voltage is output to the outside by a transistor (DC LOW) (The output is OFF when the output voltage is low). The detection voltage is set approximately 80% (75 to 90%) of the rated output voltage. Note: 1. Transistor output: Open collector 30 VDC max., 50 mA max. ON: Residual voltage 2 V max., OFF: Leakage voltage 0.1 mA max. 2. The undervoltage alarm function monitors the voltage of the output terminal of the power supply unit. To check the accurate voltage condition, measure the voltage of the load side. 3. If the setting voltage is set to 90% or less of the rated voltage, the undervoltage alarm function may operate. Inflowing current Collector −RC 1 2 Emitter Remote control connector (CN61) Undervoltage alarm output connector (CN62) Usage example of the remote control Connectors used: CN61 Model Manufacturer B2B-XH-A 2 Output connector No. 2 (Emitter) is connected with the negative output. Connectors used: Applicable connector Applicable contact XHP-2 SXH-001T-P0.6 or SXH-002T-P0.6 J.S.T. Mfg. Co., Ltd. Applicable crimp tool: YC-110R (J.S.T. Mfg. Co., Ltd.) or YRS-110 (J.S.T. Mfg. Co., Ltd.) Model Manufacturer CN62 Applicable connector Applicable contact B2B-XH-A XHP-2 SXH-001T-P0.6 or SXH-P002T-P0.6 JST Mfg. Co., Ltd. Applicable crimp tool: YC-110R (JST Mfg. Co., Ltd.) or YRS-110 (JST Mfg. Co., Ltd.) Note: 1. When the external power supply is 4.5 to 12.5 V, the current limiting resistor R is not required. When it is 12.5 to 24.5 V, insert 1.5 kΩ as the current limiting resistor R. 2. Reverse connection of the connector may cause damage on the internal parts. 3. The +RC and -RC terminals are the secondary circuit of the power supply. Use an SELV output power supply for an external power supply. The remote control circuit is insulated from the secondary output of the power supply (functional insulation). 17 S8EX Dimensions (Unit: mm) Power Supplies Open-frame Model S8EX-N015@ (15 W) Four, 3.5-dia. mounting holes 105±1 5 Output (-) 50±1 Input (N) 40±0.5 Input (L) Output (+) V.ADJ 3.5 4 17.5±0.5 5 95±0.5 18±1 4 max. (height with components mounted) S8EX-N030@ (30 W) Three, 3.5-dia. mounting holes 105±1 5 50±1 40 Output (-) Input (N) Output (+) Input (L) V.ADJ 3.5 4 95±0.5 5 23±1 4 max. (height with components mounted) S8EX-BP050@@ (50 W) Only models with remote control. +RC −RC Four, 3.5-dia. mounting holes 5 3 Input (N) V.ADJ 1 Input (L) CN51 50±1 40±0.5 5 5 CN1 122±0.5 132±1 25±1 3.5 max. (height with components mounted) 18 1 2 3 4 Output (-) Output (+) S8EX S8EX-@P100@@ (100 W) Four, 3.5-dia. mounting holes 1 Output (-) 5 62±1 52±0.5 CN51 3 Input (N) 1 Input (L) Output (+) 8 CN1 V.ADJ +RC -RC Only models with remote control. 5 5 145±0.5 155±1 32±1 3.5 max. (height with components mounted) S8EX-@P150@@ (150 W) Four, 3.5-dia. mounting holes 1 CN52 Output (-) 5 75±1 65±0.5 3 Input (N) 1 Input (L) 7 1 CN51 Output (+) CN1 V.ADJ 5 5 150±0.5 160±1 -RC +RC 6 Only models with remote control. 34±1 3.5 max. (height with components mounted) S8EX-@BP240@@ (240 W) Five, 3.5-dia. mounting holes CN51 1 Output (−) 84±1 5 74±0.5 3 Input (N) 1 Input (L) Output (+) 8 CN61 CN1 CN62 89±0.5 5 5 +RC -RC Only models with remote control. Undervoltage alarm output terminals (DC low) 170±0.5 180±1 Output voltage adjuster (V.ADJ) 39±1 3.5 max. (height with components mounted) 19 S8EX With chassis and cover S8EX-N015@L@ (15 W) 5 Four, M3 mounting holes 115±0.5 3.5 dia. 15 Output (-) 30 3.5 Input (N) 60±1 Input (L) Output (+) 30±0.5 V.ADJ 125±1 115±0.5 5 3.5 3.5 dia. 11 Two, M3 mounting holes 36±1 16 S8EX-N030@L@ (30 W) 5 Four, M3 mounting holes 115±0.5 3.5 dia. 15 Output (-)30 3.5 Input (N) 60±1 Input (L) Output (+) 30±0.5 V.ADJ 125±1 115±0.5 5 3.5 3.5 dia. 11 Two, M3 mounting holes 36±1 16 S8EX-BP050@L@ (50 W) Two, 3.5 dia. 6 150±0.5 Four, M3 mounting holes 10 20 Input (N) Input (L) 5 30 V.ADJ 3.5 CN51 3 1 2 3 4 1 CN1 20±0.5 60±1 Output (-) Output (+) 40±0.5 162±1 150±0.5 3.5 dia. 6 3.5 10 36±1 Two, M3 mounting holes 20 15 S8EX S8EX-@P100@L@ (100 W) Two, 4.5 dia. 173±0.5 Four, M4 mounting holes 6 13 23 36 1 5 Input (N) 3 Input (L) 1 CN51 Output (-) 72±1 Output (+) 4.5 V.ADJ 8 CN1 25±0.5 45±0.5 185±1 173±0.5 6 4.5 dia. Two, M4 mounting holes 4.5 15 45±1 20 S8EX-@P150@L@ (150 W) Two, 4.5 dia. 15 6 176±0.5 Four, M4 mounting holes 25 1 CN52 Output (-) 42 5 85±1 7 Input (N) 3 Input (L) 1 1 4.5 CN51 Output (+) CN1 35±0.5 6 V.ADJ 55±0.5 188±1 176±0.5 6 4.5 dia. 4.5 Two, M4 mounting holes S8EX-BP240@L@ (240 W) 47±1 20 Two, 4.5 dia. 15 15 6 Four, M4 mounting holes 200±0.5 25 CN51 1 47.5 Output (−) 4.5 5 Input (N) 3 Input (L) 1 95±1 8 Output (+) CN1 45±0.5 CN62 65±0.5 Undervoltage alarm output terminals (DC LOW) Output voltage adjuster (V.ADJ) 212±1 200±0.5 6 4.5 dia. 4.5 30 53±1 Two, M4 mounting holes 30 4.5 15 21 S8EX Safety Precautions Refer to Safety Precautions for All Power Supplies. Warning Indications Indicates a potentially hazardous situation Precautions for Safe Use CAUTION which, if not avoided, may result in minor or moderate injury or in property damage. Precautions for Supplementary comments on what to do or avoid doing, to use the product safely. Safe Use Supplementary comments on what to do or Precautions for avoid doing, to prevent failure to operate, malfunction or undesirable effect on Correct Use product performance. Meaning of Product Safety Symbols Used to warn of the risk of electric shock under specific conditions. Use to indicate prohibition when there is a risk of minor injury from electrical shock or other source if the product is disassembled. Used for general CAUTION, WARNING, or DANGER precautions for which there is no specified symbol. (This symbol is also used as the alerting symbol, but shall not be used in this meaning on the product.) Used to warn of the risk of minor injury caused by high temperatures. CAUTION Minor electric shock, fire, or Product failure may occasionally occur. Do not disassemble, modify, or repair the Product to touch the interior of the Product. Minor burns may occasionally occur. Do not touch the Product while power is being supplied or immediately after power is turned OFF. Minor injury due to electric shock may occasionally occur. Do not touch the terminals while power is being supplied. Working voltage can be 370V max. inside. This voltage can be also available 30s after the switch off. Minor electric shock, fire, or Product failure may occasionally occur. Do not allow any pieces of metal or conductors or any clippings or cuttings resulting from installation work to enter the Product. 22 Wiring • Connect the ground completely. A protective earthing terminal stipulated in safety standards is used. Electric shock or malfunction may occur if the ground is not connected completely. • Minor fire may possibly occur. Ensure that input and output terminals are wired correctly. • Be sure to remove the sheet covering the Product for machining before power-ON so that it does not interfere with heat dissipation. • Use a wire diameter of at least 1.6 times the diameter that is required for the rated current to prevent heating and ignition of wire materials due to load abnormalities. Refer to the recommended allowable current, voltage drop, and other specifications from the manufacturer of the wires to select suitable wiring materials. • The current rating of each output terminal is 2 A for -CN1 models and it is 5 A for all other models. If more than the terminal current rating will flow, use two or more terminals together. • Use wiring materials with a UL recognized temperature of 60°C min. or 60°C/75°C min. • Use wiring materials with copper conductors. • Refer to Input and Output Connectors on page 12 for the model numbers of the input and output connectors. Do not insert and remove any connector more than 20 times. Installation Environment • Do not use the Power Supply in locations subject to shocks or vibrations. In particular, install the Power Supply as far away as possible from contactors or other devices that are a vibration source. • Install the Power Supply well away from any sources of strong, high-frequency noise and surge. Ambient Operating and Storage Environments • Store the Power Supply at a temperature of -25 to 75°C and a humidity of 25% to 90%. • The Internal parts may occasionally deteriorate or be damaged. Do not use the Power Supply beyond the operating temperature range for the installation direction. • The Internal parts may occasionally deteriorate or be damaged. Do not use the Power Supply outside the derating range (i.e., the area shown by shading 1 in the derating curve diagram.) • Use the Power Supply at a humidity of 25% to 85%. • Do not use the Power Supply in locations subject to direct sunlight. • Do not use locations where liquids, foreign matter, or corrosive gases may enter the interior of the Product. S8EX Precautions for Correct Use Mounting Output Voltage Adjuster (V.ADJ) Default Setting: Set at the rated voltage Adjustment Range : The output voltage can be adjusted to ±10% of the rated voltage with the voltage output adjuster (V.ADJ) on the front panel. Turning clockwise increases the output voltage, and turning counterclockwise decreases the output voltage. • The output voltage adjuster (V.ADJ) may possibly be damaged if it is turned with unnecessary force. Do not turn the adjuster with excessive force. • After completing output voltage adjustment, be sure that the output capacity or output current does not exceed the rated output capacity or rated output current. • Adjusting the output voltage adjuster (V.ADJ) may cause the output voltage to exceed the voltage range. When adjusting the output voltage, check the output voltage of the Power Supply and be sure that the load is not destroyed. Mounting interval 4 mm min. CN1 8 mm min. 4 mm min. 4 mm min. CN1 4 mm min. 4 mm min. Mounting hole position <15 to 150 W> 8 mm 8 mm <240 W> 8mm CN1 8 mm 8 mm 8mm 8 mm 8 mm 8 mm 8 mm 8 mm 8 mm 8 mm CN1 Series Operation 8 mm 8 mm 8 mm 8 mm • Take adequate measures to ensure proper heat dissipation to increase the long-term reliability of the Product. • The S8EX-series are designed to radiate heat by means of natural air-flow. Be sure to allow convection in the atmosphere around devices when mounting. • The shaded portions indicate the allowable range of the metal mounting parts. • When mounting, use the mounting holes in the board and spacers to mount at least 8 mm off the board. This a clearance of 4 mm space is necessary to satisfy the insulation and withstand voltage standards. • Metal plate is strongly recommended as the mounting panel. Note: 1. Do not subject the board to stress such as twisting, bending, or shock. This may cause failure or deterioration. 2. During assembly, do not subject the lead feet or surface mounted parts to stress. This may cause failure or deterioration. • Do not allow cuttings to enter the Power Supply during installation. • Depending on how the Power Supply is mounted, the heat dissipating capacity may be reduced and cause deterioration to or damage internal components. • The internal parts may occasionally deteriorate and be broken due to adverse heat radiation. Do not loosen the screws on the Power Supply. Two power supplies can be connected in series. The (±) voltage output can be accomplished with two Power Supplies. Series Operation Correct Output Voltage (±) Correct AC(L) +V AC(L) +V AC(N) -V AC(N) -V AC(L) +V AC(L) +V AC(N) -V AC(N) -V Note: 1. If the load is short-circuited, a reverse voltage will be generated inside the Power Supply. If this occurs the Power Supply may possibly deteriorate or be damaged. Always connect a diode as shown in the figure. Select a diode having the following ratings. Type Schottky Barrier diode Dielectric strength (VRRM) Twice the rated output voltage or above Forward current (IF) Twice the rated output current or above 2. Although Products having different specifications can be connected in series, the current flowing through the load must not exceed the smaller rated output current. 23 S8EX Parallel Operation In Case There Is No Output Voltage The Product is not designed for parallel operation. The possible cause for no output voltage may be that the overcurrent or overvoltage protection has operated. The internal protection may operate if a large amount of surge voltage such as a lightening surge occurs while turning ON the Power Supply. In case there is no output voltage, please check the following points before contacting us: • Checking overcurrent protected status: Check whether the load is in overcurrent status or is shortcircuited. Remove wires to load when checking. • Checking overvoltage or internal protection: Turn the power supply OFF once, and leave it OFF for at least 3 minutes for S8JX-P series. Then turn it ON again to see if this clears the condition. Parallel Operation Incorrect AC(L) +V AC(N) -V AC(L) +V AC(N) -V However, the following backup operation is possible. (External diodes are required.) A D1 Load +V −V B D2 +V −V Use the same model for Power Supplies A and B. • Type: Schottky barrier diode • Dielectric strength (VRRM): Rated output voltage of the Power Supply or higher • Forward current (IF): Twice the rated output current of the Power Supply or higher • Set the output voltages of Power Supplies A and B higher to compensate for the decrease of the forward voltages (VF) of diodes D1 and D2. Also, there will be a power loss equivalent to the output current (Iout) of the Power Supply multiplied by the forward voltage (VF) of the diode. Therefore, cooling will be required to keep the temperature of the diodes lower than the catalog value. • There will be a power loss caused by load power and diodes. Be sure not to exceed the rated power (rated output voltage times rated output current) of each Power Supply. Power Boost Function • Do not allow the boost current to continue for more than the time given in the following figure (t1). Also, do not let the duty cycle exceed the following conditions. This may damage the power supply. • Lessen the load of the boost load current by adjusting the ambient temperature and the mounting orientation. • Ensure that the average current of one cycle of the boost current does not exceed the specified value. Doing so may cause the Power Supply to fail. lp : Boost current [A] lave : Average current Output current t1 t2 Models Boost current conditions • t1 ≤ 10s • Ip ≤ Rated boost current • Iave ≤ Rated current t1 • Duty = x 100[%] ≤ 20% (90 to 170 VAC) t1+t2 30% (170 to 264 VAC) S8EX-BP050@@@ (50W) S8EX-BP100@@@ (100W) Overload Protection • Internal parts may possibly deteriorate or be damaged if a shortcircuited, overload or boost load state continues during operation. • Internal parts may possibly deteriorate or be damaged if the Power Supply is used for applications with frequent inrush current or overloading at the load end. Do not use the Power Supply for such applications. Charging a Battery • t1 ≤ 10s • Ip ≤ Rated boost current • Iave ≤ Rated current × 70% (90 to 170 VAC) S8EX-BP150@@@ (150W) Rated current (170 to 264 VAC) t1 x 100[%] ≤ 10% (90 to 170 VAC) t1+t2 20% (170 to 264 VAC) • Duty = • t1 ≤ 5s • Ip ≤ Rated boost current • Iave ≤ Rated current × 70% (85 to 170 VAC) Rated current × 90% (170 to 264 VAC) t1 • Duty = x 100[%] ≤ 20% t1+t2 S8EX-BP240@@@ (240W) When connecting a battery at the load, connect an overcurrent limiting circuit and overvoltage protection circuit. Note: Make sure that the boost current meets the above conditions. Consult with your OMRON representative if any other conditions are required. Ripple Noise Voltage The specified standard for the ripple voltage noise was measured with a measurement circuit that is based on JEITA standard RC-9131A. +V C1 C2 S8EX Load −V 150 mm C1 : 100µF C2 : 0.1µF Coaxial cable 24 Oscilloscope Frequency band: 100 MHz MEMO 25 MEMO 26 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. Note: Do not use this document to operate the Unit. OMRON Corporation Industrial Automation Company Authorized Distributor: Tokyo, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 © OMRON Corporation 2012 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_7_3_0416 Printed in Japan 0413 (0112) Cat. No. T048-E1-04