Lighting Contactors Catalog Supplement 2012 Control Products www.usa.siemens.com/controls Lighting Contactors Siemens comprehensive line of lighting contactors offer a wide range of control solutions for lighting applications. These contactors can be used individually for simple control schemes or as integral components in full-featured lighting control systems. They provide reliable and efficient means of local or remote switching of lighting as well as non-inductive loads. Rugged construction, heavy-duty ratings and a wide selection of control options and accessories makes the Siemens lighting and heating contactors the right choice for your applications. Contents Class LE Electrically Held Lighting Contactors Features Catalog numbering system Selection Technical Data 2 3 4-5 6-7 Class LC Electrically Held Lighting Contactors (convertible to mechanically held) Features Catalog numbering system Selection Technical data 8 9 10 - 11 12 Accessories, factory mods and replacement parts Dimensions Wiring diagrams 13 - 16 17 - 21 22 - 24 Class CLM mechanically held lighting contactors are not included in this supplemental catalog. Please refer to either Speedfax PDPC-01000 or Industrial Control CPPC-06000 catalogs. This supplemental catalog to be discontinued once the Speedfax and Industrial Control catalogs have been updated with the new Class LE and Class LC products. Lighting Control Supplement 2012 Typical applications include: • Schools • Hospitals • Office buildings • Industrial plants • Hotels • Shopping centers • Airports • Stadiums • Resistive heaters Class LE Electrically Held Lighting Contactors Features The new Siemens Class LE lighting contactors is the latest generation of our lighting contactors. Simplicity and its compact lightweight design makes this an attractive solution to your budgeting challenges. • Used in applications where it is not critical that contacts remain closed if control power is lost • Rated for tungsten lighting (incandescent filament), ballast lighting (fluorescent, HID, metal halide, mercury vapor, quartz halogen and sodium-lamp), resistive and general use loads • Contacts are rated 20 - 400 amps at 600 volts • Wide range of coil voltages from 24 to 600 VAC 50/60Hz • Compact design allows for smaller panels and more wiring room • Finger and back-of-hand safe terminals • Panel and DIN rail mounting • 3 and 4 pole (up to 12 pole for 30 and 60 amp contactors) • Full line of enclosures including NEMA 1, 3/3R, 4, 4/4X stainless steel and 12 • Most contactors have built-in auxiliary contacts for convenient 3-wire control • Available in combination form with choice of non-fusible disconnect, fusible disconnect or circuit breaker • Full line of factory and field modifications 2 Lighting Catalog Supplement 2012 Class LE Electrically Held Lighting Contactors Catalog Numbering System LE 0 Disconnect Type B = Combination Circuit Breaker D = Combination Non-Fused Disconnect F = Combination Fusible Disconnect N = Non-Combination Disconnect Rating 0 = N/A A = 30A/250V Disconnect B = 30A/600V Disconnect C = 60A/250V Disconnect D = 60A/600V Disconnect E = 100A/250V Disconnect F = 100A/600V Disconnect G = 200A/250V Disconnect H = 200A/600V Disconnect J = 400A/250V Disconnect K = 400A/600V Disconnect T = 20A Circuit Breaker V = 30A Circuit Breaker Y = 60A Circuit Breaker Z = 100A Circuit Breaker Enclosure Type 0 = Open 1 = NEMA 1 2 = NEMA 12/3R 4 = NEMA 4/4X SS Contactor Rating (Amp) B = 20 C = 30 D = 60 E = 100 F = 200 G = 300 H = 400 N.C. Poles 0 = None N.O. Poles 03 = Three 04 = Four 06 = Six 09 = Nine 12 = Twelve Coil Voltage (AC 60Hz) 024 = 24 120 = 120 208 = 208 240 = 240 277 = 277 347 = 347 480 = 480 600 = 600 Series A = 200 – 400A Contactors B = 20 – 100A Contactors Lighting Catalog Supplement 2012 3 Class LE Electrically Held Lighting Contactors Selection Coil Table VAC 60Hz *** 24 024 120 120 208 208 240 240 277 277 347 1) 347 480 480 600 600 Replace the (***) with a number from the coil table. Non-Combination Contactor Max. Amp Rating Number of Poles Normally Closed Contacts Normally Open Contacts Enclosure Type Open 1 3/3R/12 2) 4/4X 304 S.S. LEN04B003***B Catalog Number 3 0 3 LEN00B003***B LEN01B003***B LEN02B003***B 4 0 4 LEN00B004***B LEN01B004***B LEN02B004***B LEN04B004***B 3 0 3 LEN00C003***B LEN01C003***B LEN02C003***B LEN04C003***B 4 0 4 LEN00C004***B LEN01C004***B LEN02C004***B LEN04C004***B 6 0 6 LEN00C006***B LEN01C006***B LEN02C006***B LEN04C006***B 9 0 9 LEN00C009***B LEN01C009***B LEN02C009***B LEN04C009***B 12 0 12 LEN00C012***B LEN01C012***B LEN02C012***B LEN04C012***B 3 0 3 LEN00D003***B LEN01D003***B LEN02D003***B LEN04D003***B 6 0 6 LEN00D006***B LEN01D006***B LEN02D006***B LEN04D006***B 9 0 9 LEN00D009***B LEN01D009***B LEN02D009***B LEN04D009***B 12 0 12 LEN00D012***B LEN01D012***B LEN02D012***B LEN04D012***B 100 3 0 3 LEN00E003***B LEN01E003***B LEN02E003***B LEN04E003***B 200 3 0 3 LEN00F003***A LEN01F003***A LEN02F003***A LEN04F003***A 300 3 0 3 LEN00G003***A LEN01G003***A LEN02G003***A LEN04G003***A 400 3 0 3 LEN00H003***A LEN01H003***A LEN02H003***A LEN04H003***A 20 30 60 1) 2) 4 Not available on 200 - 400A contactors. Type 12 field convertible to type 3/3R. Lighting Catalog Supplement 2012 Class LE Electrically Held Lighting Contactors Selection Coil Table VAC 60Hz *** 24 024 120 120 208 208 240 240 277 277 347 1) 347 480 480 600 600 Replace the (***) with a number from the coil table. Combination Contactor Disconnect Type Non-Fusible Max. Amp Rating Disc. Amp Rating Enclosure Type Disc Amp/ Fuse Clip Rating Circuit Breaker Rating Catalog Number 1 3/3R/12 2), 4 3) 4/4X 304 S.S. 20 3 30A — — LEDB1B003***B LEDB2B003***B LEDB4B003***B 30 3 30A — — LEDB1C003***B LEDB2C003***B LEDB4C003***B 60 3 60A — — LEDD1D003***B LEDD2D003***B LEDD4D003***B 100 3 100A — — LEDF1E003***B LEDF2E003***B LEDF4E003***B 200 3 200A — — LEDH1F003***A LEDH2F003***A LEDH4F003***A 300 3 400A — — LEDK1G003***A LEDK2G003***A LEDK4G003***A 3 — 30A/250V — LEFA1B003***B LEFA2B003***B LEFA4B003***B 3 — 30A/600V — LEFB1B003***B LEFB2B003***B LEFB4B003***B 3 — 30A/250V — LEFA1C003***B LEFA2C003***B LEFA4C003***B 3 — 30A/600V — LEFB1C003***B LEFB2C003***B LEFB4C003***B 3 — 60A/250V — LEFC1D003***B LEFC2D003***B LEFC4D003***B 3 — 60A/600V — LEFD1D003***B LEFD2D003***B LEFD4D003***B 3 — 100A/250V — LEFE1E003***B LEFE2E003***B LEFE4E003***B 3 — 100A/600V — LEFF1E003***B LEFF2E003***B LEFF4E003***B 3 — 200A/250V — LEFG1F003***A LEFG2F003***A LEFG4F003***A 3 — 200A/600V — LEFH1F003***A LEFH2F003***A LEFH4F003***A 3 — 400A/250V — LEFJ1G003***A LEFJ2G003***A LEFJ4G003***A — 20 30 60 Fusible 100 200 300 Circuit Breaker Number of NO Poles 3 — 400A/600V LEFK1G003***A LEFK2G003***A LEFK4G003***A 20 3 — — 20A LEBT1B003***B LEBT2B003***B LEBT4B003***B 30 3 — — 30A LEBV1C003***B LEBV2C003***B LEBV4C003***B 60 3 — — 60A LEBY1D003***B LEBY2D003***B LEBY4D003***B 100 3 — — 100A LEBZ1E003***B LEBZ2E003***B LEBZ4E003***B Not available on 200 - 400A contactors. Type 12 field convertible to type 3/3R. 3) Type 4 painted enclosure through 100 Amp only. 1) 2) Lighting Catalog Supplement 2012 5 Class LE Electrically Held Lighting Contactors Technical Data Contactor General technical data: Finger-safe (main circuit / control circuit) Degree of pollution Altitude (m) Ambient storage temperature (°C) Ambient operating temperature (°C) Humidity (% non-condensing) Shock resistance at rectangular impulse (g/ms) Shock resistance at sine pulse (g/ms) Rated impulse voltage resistance (kV) Rated insulation voltage (V) Mechanical operating cycles as operating time: of contactor of contactor with additional aux contacts Main circuit: Number of NC / NO main contacts Typical power loss per conductor (W) Off-load operating frequency (cycles per hour) Current ratings: Tungsten (poles per phase) Ballast (poles per phase) General and resistive (poles per phase) Coil ratings: Nominal voltage Inrush / sealed power (VA) Coil voltage tolerance factor Internal/standard auxiliary contact: Number of NC / NO auxiliary contacts Rating Installation/mounting/dimensions: Mounting orientation Type of mounting: screw / DIN rail Height x Width x Depth (mm) Minimum clearance to sides (mm) Minimum clearance to earthed parts (mm) Connection type / torque for main circuit terminals Connection type / torque for control circuit terminals Solid and stranded conductors for main contacts (AWG) Solid and stranded conductors for control circuit (AWG) Conductor type for main and control circuits Short circuit current rating of main circuit: Short circuit current rating Max fuse / circuit breaker (Amp) Certificates: 1) Must 2) Refer 6 use an external (optional) auxiliary contact. to catalog selection tables for coil voltages. Lighting Catalog Supplement 2012 LEN00B003 LEN00B004 LEN00C003 LEN00C004 yes / yes 3 2,000 -55 to 80 0 to 40 10 to 95 6.7 / 5, 4.2 / 10 10.5 / 5, 6.6 / 10 no data no data yes / yes 3 2,000 -55 to 80 0 to 40 10 to 95 6.7 / 5, 4.2 / 10 10.5 / 5, 6.6 / 10 no data no data yes / yes 3 2,000 -55 to 80 0 to 40 10 to 95 7.5 / 5, 4.7 / 10 11.8 / 5, 7.4 / 10 no data no data yes / yes 3 2,000 -55 to 80 0 to 40 10 to 95 7.5 / 5, 4.7 / 10 11.8 / 5, 7.4 / 10 no data no data 30,000,000 10,000,000 30,000,000 10,000,000 10,000,000 10,000,000 10,000,000 10,000,000 0NC / 3NO 0.7 10,000 0NC / 4NO 0.7 10,000 0NC / 3NO 0.9 5,000 0NC / 4NO 0.9 5,000 20A @277V 1p 1ph 20A @480V 2p 1ph 20A @480V 3p 3ph 20A @347V 1p 1ph 20A @600V 2p 1ph 20A @600V 3p 3ph 20A @600V 1p 1ph 20A @600V 2p 1ph 20A @600V 3p 3ph 20A @277V 1p 1ph 20A @480V 2p 1ph 20A @480V 3p 3ph 20A @347V 1p 1ph 20A @600V 2p 1ph 20A @600V 3p 3ph 20A @600V 1p 1ph 20A @600V 2p 1ph 20A @600V 3p 3ph 30A @277V 1p 1ph 30A @480V 2p 1ph 30A @480V 3p 3ph 30A @347V 1p 1ph 30A @600V 2p 1ph 30A @660V 3p 3ph 30A @600V 1p 1ph 30A @600V 2p 1ph 30A @600V 3p 3ph 30A @277V 1p 1ph 30A @480V 2p 1ph 30A @480V 3p 3ph 30A @347V 1p 1ph 30A @600V 2p 1ph 30A @600V 3p 3ph 30A @600V 1p 1ph 30A @600V 2p 1ph 30A @600V 3p 3ph 2) 2) 2) 2) 31.7 / 4.8 0.8 - 1.1 31.7 / 4.8 0.8 - 1.1 87 / 9.4 0.8 - 1.1 87 / 9.4 0.8 - 1.1 0NC / 1NO A600 / Q600 NA1) NA 1NC / 1NO A600 / Q600 1NC / 1NO A600 / Q600 vertical yes / yes 57.5 x 45 x 73 0 6 screw / 7-10 lb in screw / 7-10 lb in vertical yes / yes 57.5 x 45 x 73 0 6 screw / 7-10 lb in screw / 7-10 lb in vertical yes / yes 85 x 45 x 97 0 6 screw / 18-22 lb in screw / 7-10 lb in vertical yes / yes 85 x 60 x 97 0 6 screw / 18-22 lb in screw / 7-10 lb in 2x(20-16), 2x(18-14), 2x(12) 2x(20-16), 2x(18-14) 75°C CU 2x(20-16), 2x(18-14), 2x(12) 2x(20-16), 2x(18-14) 75°C CU 2x(6-12), 2x(14-8) 2x(20-16), 2x(18-14) 75°C CU 2x(6-12), 2x(14-8) 2x(20-16), 2x(18-14) 75°C CU 5kA @ 600V 30 / 25 UL, CSA 5kA @ 600V 30 / 25 UL, CSA 5kA @ 600V 60 / 40 UL, CSA 5kA @ 600V 60 / 40 UL, CSA Class LE Electrically Held Lighting Contactors Technical Data LEN00D003 LEN00E003 LEN00F003 LEN00G003 LEN00H003 no / yes 3 2,000 -55 to 80 0 to 40 10 to 95 10 / 5, 5 / 10 15 / 5, 8 / 10 no data no data no / yes 3 2,000 -55 to 80 0 to 40 10 to 95 6.8 / 5, 4 / 10 10.6 / 5, 6.2 / 10 no data no data no / yes 3 2,000 -55 to 80 0 to 40 10 to 95 8.5 / 5, 4.2 / 10 13.4 / 5, 6.5 / 10 no data no data no / yes 3 2,000 -55 to 80 0 to 40 10 to 95 8.5 / 5, 4.2 / 10 13.4 / 5, 6.5 / 10 no data no data no / yes 3 2,000 -55 to 80 0 to 40 10 to 95 8.5 / 5, 4.2 / 10 13.4 / 5, 6.5 / 10 no data no data 10,000,000 10,000,000 10,000,000 10,000,000 10,000,000 10,000,000 10,000,000 10,000,000 10,000,000 10,000,000 0NC / 3NO 2.6 5,000 0NC / 3NO 7.7 5,000 0NC / 3NO 13 2,000 0NC / 3NO 18 2,000 0NC / 3NO 35 2,000 60A @277V 1p 1ph 60A @480V 2p 1ph 60A @480V 3p 3ph 60A @600V 1p 1ph 60A @600V 2p 1ph 60A @600V 3p 3ph 60A @600V 1p 1ph 60A @600V 2p 1ph 60A @600V 3p 3ph 100A @277V 1p 1ph 100A @480V 2p 1ph 100A @480V 3p 3ph 100A @600V 1p 1ph 100A @600V 2p 1ph 100A @600V 3p 3ph 100A @600V 1p 1ph 100A @600V 2p 1ph 100A @600V 3p 3ph 200A @277V 1p 1ph 200A @480V 2p 1ph 200A @480V 3p 3ph 200A @600V 1p 1ph 200A @600V 2p 1ph 200A @600V 3p 3ph 200A @600V 1p 1ph 200A @600V 2p 1ph 200A @600V 3p 3ph 300A @277V 1p 1ph 300A @480V 2p 1ph 300A @480V 3p 3ph 300A @600V 1p 1ph 300A @600V 2p 1ph 300A @600V 3p 3ph 300A @600V 1p 1ph 300A @600V 2p 1ph 300A @600V 3p 3ph 400A @277V 1p 1ph 400A @480V 2p 1ph 400A @480V 3p 3ph 400A @600V 1p 1ph 400A @600V 2p 1ph 400A @600V 3p 3ph 400A@600V 1p 1ph 400A @600V 2p 1ph 400A @600V 3p 3ph 2) 2) 2) 2) 2) 166 / 12.6 0.8 - 1.1 300 / 21 0.8 - 1.1 300 / 5.8 0.8 - 1.1 590 / 6.7 0.8 - 1.1 830 / 9.2 0.8 - 1.1 NA 1) NA NA 1) NA 2NC / 2NO A300 / Q300 2NC / 2NO A300 / Q300 2NC / 2NO A300 / Q300 vertical yes / yes 112 x 55 x 115 6 6 screw / 27-40 lb in screw / 7-10 lb in vertical yes / yes 146 x 70 x 139 6 6 screw / 36-53 lb in screw / 7-10 lb in vertical yes / no 172 x 120 x 180 10 10 screw / 90-110 lb in screw / 7-10 lb in vertical yes / no 210 x 145 x 202 10 10 screw / 180-195 lb in screw / 7-10 lb in vertical yes / no 214 x 160 x 225 10 10 screw / 180-195 lb in screw / 7-10 lb in 2x(18-3), 1x(18-2) 2x(18-14) 2x(10-1/0), 1x(10-2/0) 2x(18-14) 2x(6-3/0) 2x(2/0-500MCM) 2x(2/0-500MCM) 2x(18-14) 2x(18-14) 2x(18-14) 75°C CU 75°C CU 75°C CU 75°C CU 75°C CU 5kA @ 600V 100 / 80 UL, CSA 10kA @ 600V 200 / 125 UL, CSA 10kA @ 600V 400 / 250 UL, CSA 18kA @ 600V 600 / 400 UL, CSA 18kA @ 600V 800 / 500 UL, CSA Lighting Catalog Supplement 2012 7 Class LC Electrically Held Lighting Contactors Features Siemens expands upon its lighting contactor offering with the new Class LC lighting contactor. These lighting contactors deliver unprecedented versatility in application, simplicity in Convenient side access field power wiring. configuration and performance in operation. Ingenious design, rugged construction and a host of truly useful features make them uniquely appealing to all those who use them. Contact position indication – when button protrudes, contact is closed . Power poles can easily be added at any time based on changing needs. Furthermore, they may be converted from NO to NC (or vice versa) simply by repositioning. A simple kit easily converts electrically held units to mechanically held and includes a 2- or 3-wire control module. Standard base enables contactor to be field expandable for flexibility and future needs. Plug-in auxiliary contacts are NO when installed on the left side of the contactor, NC on the right. Finger and back-of-hand safe terminals. • Used in all applications where either electrically or mechanically held contactors are specifically suited and also ideal for maximum flexibility and future expansion • Can be ordered as either electrically or mechanically held and can also be converted from electrically to mechanically held in the field with a simple conversion kit • Rated for tungsten lighting (incandescent filament), ballast lighting (fluorescent, HID, metal halide, mercury vapor, quartz halogen and sodium-lamp), resistive and general use loads • Modular design enables you to stock the building block components to assemble all configurations of both the electrically and mechanically held contactors thus dramatically reducing inventory • Contacts are rated up to 30 amps at 600 volts • Up to 12 poles (maximum of 8 normally closed) • Wide range of coil voltages from 24 to 600 VAC 50/60Hz • Full line of enclosures including NEMA 1, 3/3R, 4, 4/4X stainless steel and 12 • Full line of factory and field modifications 8 Lighting Catalog Supplement 2012 Class LC Electrically Held Lighting Contactors Catalog Numbering System LC E0 C A Controller Type E0 = Electrically Held (Convertible to MH) Enclosure Type 0 = Open 1 = NEMA 1 2 = NEMA 12/3R 4 = NEMA 4/4X Stainless Steel Contactor Rating (Amp) C = 30 N.C. Poles 0 = None 1 = One 2 = Two 3 = Three 4 = Four 5 = Five 6 = Six 7 = Seven 8 = Eight N.O. Poles 00 = None 01 = One 02 = Two 03 = Three 04 = Four 05 = Five 06 = Six 07 = Seven 08 = Eight 09 = Nine 10 = Ten 11 = Eleven 12 = Twelve Coil Voltage 024 = 24V 60Hz / 20V 50Hz 120 = 115-120V 60Hz / 110V 50Hz 208 = 200-208V 60Hz 240 = 230-240V 60Hz / 220V 50Hz 277 = 277V 60Hz / 240V 50Hz 347 = 347V 60Hz 480 = 460-480V 60Hz / 440V 50Hz 600 = 575-600V 60Hz / 550V 50Hz Lighting Catalog Supplement 2012 9 Class LC Electrically Held Lighting Contactors Selection • To order standard electrically held contactor, simply select catalog number from tables below. Coil Table VAC 60Hz *** • To order mechanically held contactor, select catalog number from tables below and specify conversion module from factory modification section from page 14. 24 024 • To convert standard electrically held contactor to mechanically held in the field, select catalog number from tables below and select conversion module kit from page 15. 240 240 277 277 347 347 480 480 600 600 120 120 208 208 Replace the (***) with a number from the coil table. Non-Combination Contactor (30 Amp max.) Enclosure Type No. of Poles N.C. Open N.O. 1 3/3R/12 1) 4/4X 304 S.S. Catalog Number 2 LCE00C200***A LCE01C200***A LCE02C200***A LCE04C200***A 3 LCE00C300***A LCE01C300***A LCE02C300***A LCE04C300***A 4 LCE00C400***A LCE01C400***A LCE02C400***A LCE04C400***A LCE00C500***A LCE01C500***A LCE02C500***A LCE04C500***A 6 LCE00C600***A LCE01C600***A LCE02C600***A LCE04C600***A 7 LCE00C700***A LCE01C700***A LCE02C700***A LCE04C700***A 8 LCE00C800***A LCE01C800***A LCE02C800***A LCE04C800***A 1 LCE00C101***A LCE01C101***A LCE02C101***A LCE04C101***A 2 LCE00C201***A LCE01C201***A LCE02C201***A LCE04C201***A 3 LCE00C301***A LCE01C301***A LCE02C301***A LCE04C301***A 4 LCE00C401***A LCE01C401***A LCE02C401***A LCE04C401***A LCE00C501***A LCE01C501***A LCE02C501***A LCE04C501***A 6 LCE00C601***A LCE01C601***A LCE02C601***A LCE04C601***A 7 LCE00C701***A LCE01C701***A LCE02C701***A LCE04C701***A 8 LCE00C801***A LCE01C801***A LCE02C801***A LCE04C801***A 0 LCE00C002***A LCE01C002***A LCE02C002***A LCE04C002***A 1 LCE00C102***A LCE01C102***A LCE02C102***A LCE04C102***A 2 LCE00C202***A LCE01C202***A LCE02C202***A LCE04C202***A 3 LCE00C302***A LCE01C302***A LCE02C302***A LCE04C302***A LCE00C402***A LCE01C402***A LCE02C402***A LCE04C402***A 5 LCE00C502***A LCE01C502***A LCE02C502***A LCE04C502***A 6 LCE00C602***A LCE01C602***A LCE02C602***A LCE04C602***A 7 LCE00C702***A LCE01C702***A LCE02C702***A LCE04C702***A 8 LCE00C802***A LCE01C802***A LCE02C802***A LCE04C802***A 0 LCE00C003***A LCE01C003***A LCE02C003***A LCE04C003***A 1 LCE00C103***A LCE01C103***A LCE02C103***A LCE04C103***A 2 LCE00C203***A LCE01C203***A LCE02C203***A LCE04C203***A 3 LCE00C303***A LCE01C303***A LCE02C303***A LCE04C303***A LCE00C403***A LCE01C403***A LCE02C403***A LCE04C403***A 5 LCE00C503***A LCE01C503***A LCE02C503***A LCE04C503***A 6 LCE00C603***A LCE01C603***A LCE02C603***A LCE04C603***A 7 LCE00C703***A LCE01C703***A LCE02C703***A LCE04C703***A 8 LCE00C803***A LCE01C803***A LCE02C803***A LCE04C803***A 5 5 4 4 0 1 2 3 1) Type 12 field convertible to Type 3/3R. 10 Lighting Catalog Supplement 2012 Class LC Electrically Held Lighting Contactors Selection Non-Combination Contactor (30 Amp max.) Enclosure Type No. of Poles N.C. Open N.O. 1 3/3R/12 1) 4/4X 304 S.S. Catalog Number 0 LCE00C004***A LCE01C004***A LCE02C004***A LCE04C004***A 1 LCE00C104***A LCE01C104***A LCE02C104***A LCE04C104***A 2 LCE00C204***A LCE01C204***A LCE02C204***A LCE04C204***A 3 LCE00C304***A LCE01C304***A LCE02C304***A LCE04C304***A LCE00C404***A LCE01C404***A LCE02C404***A LCE04C404***A 5 LCE00C504***A LCE01C504***A LCE02C504***A LCE04C504***A 6 LCE00C604***A LCE01C604***A LCE02C604***A LCE04C604***A 7 LCE00C704***A LCE01C704***A LCE02C704***A LCE04C704***A 8 LCE00C804***A LCE01C804***A LCE02C804***A LCE04C804***A 0 LCE00C005***A LCE01C005***A LCE02C005***A LCE04C005***A 1 LCE00C105***A LCE01C105***A LCE02C105***A LCE04C105***A 2 LCE00C205***A LCE01C205***A LCE02C205***A LCE04C205***A 3 LCE00C305***A LCE01C305***A LCE02C305***A LCE04C305***A 4 LCE00C405***A LCE01C405***A LCE02C405***A LCE04C405***A 5 LCE00C505***A LCE01C505***A LCE02C505***A LCE04C505***A 6 LCE00C605***A LCE01C605***A LCE02C605***A LCE04C605***A 0 LCE00C006***A LCE01C006***A LCE02C006***A LCE04C006***A 1 LCE00C106***A LCE01C106***A LCE02C106***A LCE04C106***A LCE00C206***A LCE01C206***A LCE02C206***A LCE04C206***A LCE00C306***A LCE01C306***A LCE02C306***A LCE04C306***A 4 LCE00C406***A LCE01C406***A LCE02C406***A LCE04C406***A 5 LCE00C506***A LCE01C506***A LCE02C506***A LCE04C506***A 6 LCE00C606***A LCE01C606***A LCE02C606***A LCE04C606***A 0 LCE00C007***A LCE01C007***A LCE02C007***A LCE04C007***A LCE00C107***A LCE01C107***A LCE02C107***A LCE04C107***A LCE00C207***A LCE01C207***A LCE02C207***A LCE04C207***A 3 LCE00C307***A LCE01C307***A LCE02C307***A LCE04C307***A 4 LCE00C407***A LCE01C407***A LCE02C407***A LCE04C407***A 0 LCE00C008***A LCE01C008***A LCE02C008***A LCE04C008***A LCE00C108***A LCE01C108***A LCE02C108***A LCE04C108***A LCE00C208***A LCE01C208***A LCE02C208***A LCE04C208***A 3 LCE00C308***A LCE01C308***A LCE02C308***A LCE04C308***A 4 LCE00C408***A LCE01C408***A LCE02C408***A LCE04C408***A 0 LCE00C009***A LCE01C009***A LCE02C009***A LCE04C009***A LCE04C109***A 4 4 5 2 3 6 1 2 7 1 2 1 8 9 LCE00C109***A LCE01C109***A LCE02C109***A 2 LCE00C209***A LCE01C209***A LCE02C209***A LCE04C209***A 0 LCE00C010***A LCE01C010***A LCE02C010***A LCE04C010***A LCE00C110***A LCE01C110***A LCE02C110***A LCE04C110***A LCE00C210***A LCE01C210***A LCE02C210***A LCE04C210***A 1 10 2 0 11 LCE00C011***A LCE01C011***A LCE02C011***A LCE04C011***A 0 12 LCE00C012***A LCE01C012***A LCE02C012***A LCE04C012***A 1) Type 12 field convertible to Type 3/3R. Lighting Catalog Supplement 2012 11 Class LC Electrically Held Lighting Contactors Technical Data General technical data: Finger-safe (main circuit / control circuit) yes / yes Degree of pollution 3 Altitude (m) 2,000 Ambient storage temperature (°C) -30 to 65 Ambient operating temperature (°C) -25 to 40 Humidity (% non-condensing) no data Shock resistance at rectangular impulse (g/ms) no data Shock resistance at sine pulse (g/ms) no data Rated impulse voltage resistance (kV) no data Rated insulation voltage (V) 600 Mechanical operating cycles as operating time: of contactor 100,000 of contactor with additional aux contacts 100,000 Main circuit: Number of main contacts 2 - 12 (maximum of 8 NC) Typical power loss per conductor (W) no data Off-load operating frequency (cycles per hour) 60 for continued operation Current ratings: 20A @277V 1p 1ph Tungsten (poles per phase) 20A @480V 2p 1ph 20A @480V 3p 3ph 30A @347V 1p 1ph Ballast (poles per phase) 30A @600V 2p 1ph 30A @600V 3p 3ph 30A @600V 1p 1ph General and resistive (poles per phase) 30A @600V 2p 1ph 30A @600V 3p 3ph Coil ratings: Nominal voltage (refer to coil voltage table) Inrush / sealed power (VA) 248 / 28 Coil voltage tolerance factor 0.85 - 1.1 External/optional auxiliary contact: Number of NC / NO auxiliary contacts Rating Installation/mounting/dimensions: Mounting orientation Type of mounting: screw / DIN rail Height x Width x Depth (mm) Minimum clearance to sides (mm) Minimum clearance to earthed parts (mm) Connection type / torque: Main contact terminals Coil terminals Auxiliary contact terminals Control module terminals Solid and stranded conductors (AWG): Main contact terminals 2NC / 2NO max A600, 24VDC, 24VAC vertical yes / no 188 x 106 x 98 12.7 12.7 screw / 35 lb in screw / 15 lb in screw / 7-12 lb in screw / 5 lb in 1x(14-8), #8 solid or stranded 2x(14-8), #8 stranded only 2x(18-14) 2x(22-12) 1x(22-12) 75°C CU / 60-75°C CU Coil terminals Auxiliary contact terminals Control module terminals Conductor type for main / control circuits Short circuit current rating of main circuit: Short circuit current rating (see SCCR tables) Certificates: cUL, CE 12 Lighting Catalog Supplement 2012 Coil voltages: 24V 60Hz / 20V 50Hz 115-120V 60Hz / 110V 50Hz 200-208V 60Hz 230-240V 60Hz / 220V 50Hz 277V 60Hz / 240V 50Hz 347V 60Hz 460-480V 60Hz / 440V 50Hz 575-600V 60Hz / 550V 50Hz Short circuit current ratings with fuses: Max. Volt. Fuse Max. Device Rating (Amps) 600 RK fuse 60 SCCR (kA) 100 Short circuit current ratings with circuit breakers: Max. Volt. Siemens Listed Circuit Breaker Max. Device Rating (Amps) SCCR (kA) 600 NGG3B040L 40 14 480 HEG3B040L 40 65 480 ED63B040L 40 25 480 NGG3B040L 40 25 Conversion module: Input Volt. (AC) Steady State Current @ Rated Volts (mA) Max. VA 24 80 5 115-120 83 12 200-277 91 30 Conversion module: Min. pulse duration (3-wire module) 250ms Max. allowable leakage current 1.8 mA EMI 35 V/m Surge transient peak 6 kV Frequency range 40-70 Hz Accessories, Factory Mods & Replacement Parts Selection Push Buttons and Selector Switches Class Enclosure type Contactor Size (Amp) 1 (non-combination) 20 - 100 1 (non-combination) 12, 4/4X (non-com.) 1, 12, 4/4X (com.) 200 - 400 20 - 400 20 - 400 Enclosure type Contactor Size (Amp) All Pilot Lights Class 1 (non-combination) 1 (non-combination) 20 - 100 20 - 100 All 1 (non-combination) 12, 4/4X (non-com.) 1, 12, 4/4X (com.) 1, 12, 4/4X Auxiliary Contact Kits 200 - 400 20 - 400 20 - 400 All Class Enclosure type Contactor Size (Amp) LC Open, 1, 12, 4/4X 30 LE Open, 1, 12, 4/4X Description Start, Stop Push Buttons Hand-Off-Auto Selector Switch Off-On Selector Switch Start, Stop Push Buttons Field Kit Catalog No. 49SBPB5 49SBSB1 49SBSB4 49SAP05 Factory Mod Suffix A1 A3 A4 A1 Hand-Off-Auto Selector Switch Keyed Hand-Off-Auto Off-On Selector Switch 49SAS01 49SAS09 49SAS04 A3 A9 A4 Description Field Kit Catalog No. Factory Mod Suffix Red On 24 VAC 49SBLBJ Red On 120 VAC 49SBLBF Red On 208/240/277 VAC 49SBLBG Red On 347 VAC NA Red On 480 VAC 49SBLBH Red On 600 VAC 49SBLBE Green Off 24 VAC 49SBLBJ Green Off 120 VAC 49SBLBF Green Off 208/240/277 VAC 49SBLBG Green Off 347 VAC NA Green Off 480 VAC 49SBLBH Green Off 600 VAC 49SBLBE Red On 24 VAC 49SPL0BRJ Red On 120 VAC 49SPL0BRF Red On 208/240 VAC 49SPL0BRG Red On 277 or 347 VAC NA Red On 480 VAC 49SPL0BRH Red On 600 VAC 49SPL0BRE Green Off 24 VAC 49SPL0AGJ Green Off 120 VAC 49SPL0AGF Green Off 208/240 VAC 49SPL0AGG Green Off 277 or 347 VAC NA Green Off 480 VAC 49SPL0AGH Green Off 600 VAC 49SPL0AGE FA FK FA FK Green On (all except 277 & 347 VAC) FB Red Off (all except 277 & 347 VAC) FJ Red On PTT (all except 277 & 347 VAC) NA FS Grn On PTT (all except 277 & 347 VAC) FT Grn Off PTT (all except 277 & 347 VAC) FU Field Kit Catalog No. Factory Mod Suffix 1 NO/NC 49LCAC1PA G11 2 NO/NC 49LCAC2PA G22 Description 20 Front Mounted 1 NO/NC 3RH2911-1HA11 G11 30 Side Mounted 1 NO/NC 3RH2911-1DA11 G11 60-400 Side Mounted 1 NO/NC 3RH1921-1DA11 G11 Lighting Catalog Supplement 2012 13 Accessories, Factory Mods & Replacement Parts Selection Power Pole Kits Electrically Held to Mechanically Held Conversion Modules Class LC Enclosure type Open, 1, 12, 4/4X Contactor Size (Amp) 30 Class Enclosure type Contactor Size (Amp) LC Miscellaneous Kits Open, 1, 12, 4/4X 30 Class Enclosure type Contactor Size (Amp) All 1, 12, 4/4X All All 1, 12, 4/4X All 1, 12, 4/4X Description Single power pole Double power pole Field Kit Catalog No. 49LCPP1A 49LCPP2A Factory Mod Suffix N/A Description Field Kit Catalog No. Factory Mod Suffix 2-wire, 24VAC 49LCCM1A M1 2-wire, 110-120VAC 49LCCM2A M2 2-wire, 200-277VAC 49LCCM3A M3 3-wire, 24VAC 49LCCM4A M4 3-wire, 110-120VAC 49LCCM5A M5 3-wire, 200-277VAC 49LCCM6A M6 Field Kit Catalog No. Factory Mod Suffix Ground Lug Kit Ground Lug Kit Meets CSA Standard 22.2 No 14-1973. 1 Conductor 2-14 For AL/CU Wire. 49D11960001 L10 All Single pole control circuit fuse and holder. 250V Midget fuse block for domestic fusing. KCCF1G F1 All Double pole control circuit fuse and holder. Class CC 600V fuse block for domestic fusing. KCCFP2RG F2 Description Control relay with 4 NO contacts Control relay with 2 NO/2 NC All 1, 12, 4/4X All Control relay with 4 NC contacts R40 (Refer to Industrial Control Catalog for selection) R22 R04 24 hour time clock T7 24 hour time clock with day omission All 1, 12, 4/4X All 7 day time clock T8 N/A T9 All All 14 1, 12, 4/4X 1, 12, 4/4X Lighting Catalog Supplement 2012 All All 3 Point terminal TC3 6 Point Terminal (Refer to Industrial Control Catalog for selection) TC6 N/A N1 9 Point Terminal Function identification plate, with marking as specified TC9 Accessories, Factory Mods & Replacement Parts Selection Control Power Transformers (Field Modification Kits) Step 1 Recommended Minimum Transformer Size Step 2 Voltage Code Contactor Primary Volts CPT VA Secondary Volts Code Step 3 VA Rating Catalog Number LC 30A 2-12P 45 120 24 1 45 VA KT*050 LE 20,30,60A 3P 45 208 24 G 50 VA KT*050P LE 30A 6P 45 208 120 H 100 VA KT*100 KT*150 LE 30A 9-12P 100 240/480 24 4 150 VA LE 60A 6-9P 100 240/480 120 8 200 VA KT*200 LE 60A 12P 150 277 24 5 300 VA KT*300 LE 100,200A 3P 100 277 120 7 500 VA KT*500 LE 300,400A 3P 150 600 24 6 600 120 9 To select CPT field kit: 1. Determine recommended minimum CPT size (VA) based on contactor size and poles. 2. Determine voltage code based on required CPT primary and secondary voltages. 3. Complete the catalog number by replacing the (*) with the voltage code. 45VA transformer kits will include secondary but not primary fusing. Sizes 50VA and higher include 2-pole primary fusing and 1-pole secondary fusing. Control Power Transformers (Factory Modification) Class AB Enclosure type 1, 12, 4/4X Contactor Size (Amp) All Step 1 Description Step 3 Factory Mod Suffix Standard Capacity with 1-Secondary Fuse (45VA only) B* Standard Capacity with 2-Primary and 1-Secondary Fuse D* 100VA Extra Capacity with 2-Primary and 1-Secondary Fuse C* 150VA Extra Capacity with 2-Primary and 1-Secondary Fuse C*1 To select CPT factory modification suffix: 1. Select factory mod suffix based on capacity requirements. Select extra capacity if field installed devices will be powered from CPT. Otherwise, select standard capacity. The factory will determine the actual size of the CPT. 2. Determine voltage code based on required CPT primary and secondary voltages. 3. Complete the mod suffix by replacing the (*) with the voltage code. Step 2 Voltage Code Primary Volts Secondary Volts Code 120 24 B 208 24 S 208 120 T 240 24 J 240 120 F 277 24 N 277 120 P 380 110 U 415 100 W 480 240 R 480/240 24 D 480/240 120 A 600 24 E 600 120 C Lighting Catalog Supplement 2012 15 Accessories, Factory Mods & Replacement Parts Selection Enclosure Kits Contactor Type 1 1) Type 4/4X Stainless Steel 2) Type 3/3R/12 3) Without CPT With CPT Max. Without CPT With CPT Max. Without CPT With CPT Max Catalog Number Catalog Number CPT VA Catalog Number Catalog Number CPT VA Catalog Number CPT VA 49EC14GB140807R 49EC14IB201208R 200 49EB22GW161406R 49EB22GW161406R 49EB22G0161406R 49EB22G0161406R LE 20, 30A 3-4P 49EC14EB110705R 49EC14IB201208R 200 49EB22GW161406R 49EB22GW161406R 49EB22G0161406R 49EB22G0161406R LC 30A 2-12P LE 30A 6-9P 49EC14IB201208R 49EC14IB201208R 200 49EB14JW261408R 49EB14JW261408R LE 30A 12P 49EC14IB201208R 49EC14JB251409R 250 49EB14JW261408R NA LE 60A 3P 49EC14GB140807R 49EC14IB201208R 200 49EB22GW161406R 49EB22GW161406R NA LE 60A 6-9P 49EC14IB201208R 49EC14IB201208R 200 49EB14JW261408R 49EB14JW261408R LE 60A 12P 49EC14IB201208R 49EC14JB251409R 250 49EB14JW261408R NA LE 100A 3P 49EC14IB201208R 49EC14IB201208R 200 49EB14JW261408R 49EB14JW261408R NA Hole plug for the cover overload reset button is included with enclosure. Install NEMA 4X hole plug cat. no. 52ABHS (not included) over the hole for the overload reset button. 3) Install NEMA 12 hole plug cat. no. 52ABH6 (not included) over the hole for the overload reset button. 1) 2) Replacement Coil Kits Class LC Contactor Size (Amp) 30 20, 30 60 LE 100 Replacement Contact Kits Description Catalog No. 24V 60Hz / 20V 50Hz 75LCC024A 115-120V 60Hz / 110V 50Hz 75LCC120A 200-208V 60Hz 75LCC208A 230-240V 60Hz / 220V 50Hz 75LCC240A 277V 60Hz / 240V 50Hz 75LCC277A 347V 60Hz 75LCC347A 460-480V 60Hz / 440V 50Hz 75LCC480A 575-600V 60Hz / 550V 50Hz 75LCC600A NA NA 24VAC 50/60HZ 3RT19355AC21 110VAC 50HZ / 120VAC 60HZ 3RT19355AK61 208VAC 50/60HZ 3RT19355AM21 220VAC 50HZ / 240VAC 60HZ 3RT19355AP61 277VAC 60HZ 3RT19355AU61 347VAC 60HZ 3RT19355AW61 480VAC 60HZ 3RT19355AV61 600VAC 60HZ 3RT19355AT61 24VAC 50/60HZ 3RT19455AC21 110VAC 50HZ / 120VAC 60HZ 3RT19455AK61 208VAC 50/60HZ 3RT19455AM21 220VAC 50HZ / 240VAC 60HZ 3RT19455AP61 277VAC 60HZ 3RT19455AU61 347VAC 60HZ 3RT19455AW61 480VAC 60HZ 3RT19455AV61 600VAC 60HZ 3RT19455AT61 Class Contactor Size (Amp) Description Catalog No. LC 30 NA NA 20, 30 NA 60 LE 16 100 200 300 400 Lighting Catalog Supplement 2012 NA 3RT1935-6A 1 contact kit includes 3 moving and 6 fixed contacts. 3RT1945-6A 3RT1956-6A 3RT1965-6A 3RT1975-6A Catalog Number 49EB14J0261408R 49EB14J026140BR 49EB14J026140BR NA 49EB22G0161406R 49EB22G0161406R 49EB14J0261408R 49EB14J0261408R 49EB14J0261408R NA 49EB14J0261408R 49EB14J0261408R NA NA Dimensions Class LC Open Contactors .35 [9.0] POWER POLE OPTIONAL POWER POLES 7.39 [187.7] 6.50 [165.1] OPTIONAL "NC" AUX-CONTACTS OPTIONAL "NO" AUX-CONTACTS P1 P2 P3 P4 P5 MOUNTING HOLES ACCEPT #10 SCREWS A1 .35 [9.0] .22 [5.5] 3.86 [98.0] A2 3.75 [95.3] .59 [14.9] 4.18 [106.2] 2 "NO" AUX CONTACTS 2 "NC" AUX CONTACTS 1 "NO" AUX CONTACT P1 P2 P3 P4 P5 3.86 [98.0] 1 "NC" AUX CONTACT Note: 1) Mounting Dimensions remain the same for 1 to 12 Poles 2) Line and Load terminals are inter-changeable 3) Up to 2NO and 2NC auxiliary contacts can be added onto the base product 4) Same Power Pole can be configured as NO type or NC type Lighting Catalog Supplement 2012 17 Dimensions Class LE Open Contactors LEN00B (20A 3 Pole and 4 Pole) 73 5 35 50 57.5 29.8 45 5 LEN00C003 (30A 3 Pole) 45 35.1 97 7.5 75 5 2.5 85 43 4.8 5 5 LEN00C004 (30A 4 Pole) 60 45 97 35.1 7.5 75 5 2.5 87 43 4.8 5 18 Lighting Catalog Supplement 2012 5 Dimensions Class LE Open Contactors LEN00D003 (60A 3 Pole) 55 35 17 110 5 64 45 95 64 111 5 LEN00E003 (100A 3 Pole) 134 86 22,5 22,5 46 5 60 5 22,5 70 LEN00C006 (30A 6 Pole) LEN00D006 (60A 6 Pole) 130 104 140 SIEMENS 7 8 LEN00C009 (30A 9 Pole) and LEN00D009 (60A 9 Pole) LEN00C012 (30A 12 Pole) and LEN00D012 (60A 12 Pole) Note – Only the 12 pole contactor is shown. However, the dimensions of the mounting plate are the same for the 9 pole contactor. Lighting Catalog Supplement 2012 19 Dimensions Class LE Open Contactors LEN00F003 (200A 3 Pole) 169 107 17 61 37 9 100 130 170 140 SIEMENS 7 120 LEN00G003 (300A 3 Pole) 96 48 71 120 9 180 168 210 SIEMENS 145 132 202 LEN00H003 (400A 3 Pole) 96 48 89 130 9 20 25 1 51 160 Lighting Catalog Supplement 2012 180 182 200 SIEMENS 150 224 Dimensions Class LC and LE Enclosed Contactors Figure 2 Figure 1 Enclosure Type 1 without CPT 1 with CPT 12/3R & 4/4X without CPT 12/3R & 4/4X with CPT Contactor Rating Fig. LE 20/30A 3-4P Figure 3 Outline Dimensions Mounting Conduit Size A B C D E K1 K2 K3 K4 K5 1 10.97 6.41 5.03 8.22 4.62 0.5 0.50-0.75 0.75–1 — — LC 30A 2-12P, LE 60A 3P 1 13.53 7.97 6.38 10.25 6.00 0.50-0.75 0.75-1 1-1.25 — — LE 30/60A 6-12P, LE 100A 3P 1 19.12 11.38 7.69 15.62 8.25 0.50-0.75 1-1.25 1.5-2 — — LE 200-400A 3P 2 26.00 17.62 12.50 25.19 15.50 0.50-0.75 1.25-1.5 1.25-1.5 — — LC 30A 2-12P, LE 20A 3-4P, LE 30A 3-9P, LE 60A 3-9P, LE 100A 3P 1 19.12 11.38 7.69 15.62 8.25 0.50-0.75 1-1.25 1.5–2 — — LE 30/60A 12P 1 24.88 13.38 8.12 21.75 9.00 0.50-0.75 1.25-1.5 2-2.5 — — LE 200-400A 3P 2 26.00 17.62 12.50 25.19 15.50 — 1.25-1.5 1.25-1.5 — — LE 20/30A 3-4P, LC 30A 2-12P, LE 60A 3P 2 16.00 13.25 6.12 15.25 11.00 — — — — — LE 30/60A 6-12P, LE 100A 3P 2 26.00 13.12 7.56 25.25 10.00 — — — — — LE 200-400A 3P 2 26.00 17.62 12.50 23.19 15.50 — — — — — LE 20/30A 3-4P, LC 30A 2-12P, LE 60A 3P 2 16.00 13.25 6.12 15.25 11.00 — — — — — LE 30/60A 6-12P, LE 100A 3P 2 26.00 13.12 7.56 25.25 10.00 — — — — — LE 200-400A 3P 2 26.00 17.62 12.50 25.19 15.50 — — — — — Enclosure Type 1, 12 & 4/4X with & without CPT Type Fusible and Non-fusible Disconnect Circuit Breaker Outline Dimensions Contactor Rating Fig. A B 20–60A 3 24 11 100A 3 24 20 8 200A 3 46 20 10 300A 3 76 22 13 200-100A 3 24 11 8 C 8 Dimensions are in inches. 1) G designates mounting screw size. Lighting Catalog Supplement 2012 21 Wiring Diagrams Class LC and LE Electrically Held Contactors LEN00D003 (60A 3 Pole) LEN00E003 (100A 3 Pole) LEN00B003 (20A 3 Pole) A1 1 /L1 3 /L2 5 L3 13 A2 2 /T1 4 /T2 6 /T3 14 1 /L1 3 /L2 5 /L3 1/L1 3/L2 5/L3 A2 2/T1 4/T2 6/T3 LEN00F003 (200A 3 Pole) LEN00G003 (300A 3 Pole) LEN00H003 (400A 3 Pole) LEN00B004 (20A 4 Pole) A1 A1 7 /L4 A1 1 /L1 3 /L2 5 /L3 13 21 31 43 A2 2 /T1 4 /T2 6 /T3 14 22 32 44 U A2 2 /T1 4 /T2 6 /T3 8 /T4 LEN00C003 (30A 3 Pole) A1 1 /L1 3 /L2 5 /L3 13 21 LCE00C (30A 2-12 Pole) LINE LOAD 1 2 A2 2 /T1 4 /T2 6 /T3 14 22 3 4 LEN00C004 (30A 4 Pole) A1 1 /L1 3 /L2 5 /L3 7 /L4 13 21 5 6 A1 A2 COIL A2 2 /T1 4 /T2 6 /T3 8 /T4 14 22 COIL VOLTAGE OPTIONAL AUXILIARY CONTACTS 22 Lighting Catalog Supplement 2012 Wiring Diagrams Class LC and LE Electrically Held Contactors Optional Pilot Devices for Electrically Held Contactor ON ON PB OFF PB ON and OFF Push buttons L1 FUSE * COIL A2 FUSE A1 * L2 REMOTE OFF AUXILIARY CONTACT REMOTE ON AUXILIARY CONTACT OFF SS OFF-ON or OFF-AUTO Selector Switch REMOTE DEVICE L1 ON AUTO OFF * FUSE COIL A2 A1 FUSE * L2 AUXILIARY CONTACT OFF ON OFF-ON-AUTO HAND-OFF-AUTO Selector Switch L1 FUSE * ON REMOTE DEVICE OFF A2 AUTO COIL A1 FUSE * L2 AUXILIARY CONTACT OFF * -- IF USED Lighting Catalog Supplement 2012 23 Wiring Diagrams Class LC Contactor (converted to mechanically held) LINE LOAD 4!",%! 7)2%#/.42/, %,%#42/.)#-/$5,% 2%&%24/4!",%"&/2 #/.42/,#/..%#4)/.3 2 00000 ./453%$ /04)/.!,./ !58#/.4!#4 # 3 ! /04)/.!,g.#g !58),)!29#/.4!#4 1 ! #/), #/),6/,4!'% 4 7)2%#/.42/, %,%#42/.)#-/$5,% 2%&%24/4!",%#&/2 #/.42/,#/..%#4)/.3 5 00000 /04)/.!,./ !58#/.4!#4 ! REFER TO TABLE A FOR 2/3 WIRE CONTROL OPTIONS /04)/.!,g.#g !58),)!29#/.4!#4 , 6 ! #/), / #/),6/,4!'% # TABLE B : OPTIONAL PILOT DEVICES FOR 2 WIRE CONTROL ON (AUTO) ELECTRONIC-MODULE P1 P2 P3 P5 P4 * CONTROL VOLTAGE FUSE OFF COIL ON * FUSE A1 A2 COIL VOLTAGE SELECTOR SWITCH OFF-AUTO OFF-ON or SS OFF P3 P4 P5 FUSE OFF AUTO REMOTE DEVICE ON COIL A2 * COIL VOLTAGE P1 P2 OFF CONTROL VOLTAGE SELECTOR SWITCH ON-OFF-AUTO HAND-OFF-AUTO or ELECTRONIC-MODULE ON FUSE * A1 TABLE C : OPTIONAL PILOT DEVICES FOR 3 WIRE CONTROL "NO" AUXILIARY REMOTE OFF P2 P3 P4 P5 OFF ON COIL REMOTE ON "NC" AUXILIARY "NO" AUXILIARY A2 FUSE * A1 ELECTRONIC-MODULE P1 P2 P3 P4 P5 FUSE OFF ON "NC" AUXILIARY A2 COIL ON FUSE A1 * -- IF USED 24 Lighting Catalog Supplement 2012 * OFF * COIL VOLTAGE CONTROL VOLTAGE ON * COIL VOLTAGE P1 FUSE CONTROL VOLTAGE PUSH BUTTONS RETURN TO CENTER OFF-ON SELECTOR SWITCH WITH SPRING ON & OFF ELECTRONIC-MODULE OFF Siemens Industry, Inc. 3333 Old Milton Parkway Alpharetta, GA 30005 1-800-241-4453 [email protected] www.usa.siemens.com/controls Subject to change without prior notice. Order No. NECS-LTGCT-1211 All rights reserved. Printed in USA. ©2011 Siemens Industry, Inc. The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.