SIEMENS Product data sheet E87010-A0107-T007-A6-LCE0 Lighting Contactor Class LC Electrically Held Convertible to Mechanically Held 30 Amp, 2-12 Pole General technical data: Finger-safe (main circuit / control circuit) Degree of pollution Altitude (m) Ambient storage temperature (°C) Ambient operating temperature (°C) Humidity (% non-condensing) Shock resistance at rectangular impulse (g/ms) Shock resistance at sine pulse (g/ms) Rated impulse voltage resistance (kV) Rated insulation voltage (V) Mechanical operating cycles as operating time: of contactor of contactor with additional aux contacts Main circuit: Number of main contacts Typical power loss per conductor (W) Off-load operating frequency (cycles per hour) Current ratings: Tungsten (poles per phase) Ballast (poles per phase) General & resistive (poles per phase) Coil ratings: Inrush / sealed power (VA) Coil voltage tolerance factor Coil code 024 Coil code 120 Coil code 208 Coil code 240 Coil code 277 Coil code 347 Coil code 480 Coil code 600 External/optional auxiliary contact: Number of NC / NO auxiliary contacts Rating ©2012 Siemens Industry, Inc. Subject to change without prior notice. Siemens Industry, Inc. 5300 Triangle Parkway, Norcross, GA 30092 yes / yes 3 2,000 -30 to 65 -25 to 40 no data no data no data no data 600 100,000 100,000 2 - 12 (maximum of 8 NC)) ( no data 60 for continued operation 20A @277V 1p 1ph 20A @480V 2p 1ph 20A @480V 3p 3ph 30A @347V 1p 1ph 30A @600V 2p 1ph 30A @600V 3p 3ph 30A @600V 1p 1ph 30A @600V 2p 1ph 30A @600V 3p 3ph 248 / 28 0.85 - 1.1 24V 60Hz / 20V 50Hz 115-120V 60Hz / 110V 50Hz 200-208V 60Hz 230-240V 60Hz / 220V 50Hz 277V 60Hz / 240V 50Hz 347V 60Hz 460-480V 60Hz / 440V 50Hz 575-600V 60Hz / 550V 50Hz 2NC / 2NO max 10A, 600VAC, A600 A5E31166492A-001 Page 1 of 4 Installation/mounting/dimensions: Mounting orientation Type of mounting: screw / DIN rail Height x Width x Depth (mm) Minimum clearance to sides (mm) Minimum clearance to earthed parts (mm) Connection type / torque: Main contact terminals Coil terminals Auxiliary contact terminals Control module terminals Solid & stranded conductors (AWG): Main contact terminals Coil terminals Auxiliary contact terminals Control module terminals Conductor type for main / control circuits Short circuit current rating of main circuit: RK fuse 600V max. / 60A max. Siemens circuit breaker NGG3B040L 600V max. / 40A max. Siemens circuit breaker HEG3B040L 480V max. / 40A max. Siemens circuit breaker ED63B040L 480V max. / 40A max. Siemens circuit breaker NGG3B040L 480V max. / 40A max. Conversion module: 24 VAC input: steady state current / Max VA 115-120 VAC input: steady state current / Max VA 200 - 277VAC input: steady state current / Max VA Min. pulse duration (3-wire module) Max. allowable leakage current EMI Surge transient peak Frequency range Certificates: ©2012 Siemens Industry, Inc. Subject to change without prior notice. Siemens Industry, Inc. 5300 Triangle Parkway, Norcross, GA 30092 vertical yes / no 188 x 106 x 98 12.7 12.7 screw / 35 lb in screw / 15 lb in screw / 7-12 lb in screw / 5 lb in 1x(14-8), #8 solid or stranded 2x(14-8), #8 stranded only 2x(18-14) 2x(22-12) 1x(22-12) 75°C CU / 60-75°C CU 5kA 5kA 5kA 5kA 5kA 80 mA / 5 VA 83 mA / 12 VA 91 mA / 30 VA 250 ms 1.8 mA 35 V/m 6 kV 40-70 Hz cULus A5E31166492A-001 Page 2 of 4 ©2012 Siemens Industry, Inc. Subject to change without prior notice. Siemens Industry, Inc. 5300 Triangle Parkway, Norcross, GA 30092 A5E31166492A-001 Page 3 of 4 Wiring Diagram (Electrically Held) Wiring Diagram Mechanically Held) ©2012 Siemens Industry, Inc. Subject to change without prior notice. Siemens Industry, Inc. 5300 Triangle Parkway, Norcross, GA 30092 A5E31166492A-001 Page 4 of 4