Starters and Switches, Class 11

Manual Control
Starters and Switches, Class 11 - 3RV
Class 11 - 3RV
Class 11 across the line manual
starters and switches provide control
for machinery where remote start stop
control is not required.
Class 11 - 3RV manual starters are
used for single and poly-phase motors
up to 20HP @ 575V. Starters have bimetallic heater elements to provide class
10 overcurrent protection. Each starter
has a fourth bimetallic strip that reacts
only to the ambient temperature
inside the control panel. This ambient
compensation helps prevent the starter
from nuisance tripping when the panel
temperature is higher than the ambient
temperature of the motor.
A built-in differential trip bar causes the
starter to trip faster on a phase loss
condition to help reduce motor damage.
Magnetic trip elements in each starter
take the device off line when it senses
current of 13 times the maximum FLA
dial setting.
blowers, textile and packaging
machinery, and paper cutters.
Each switch is provided with magnetic
trip elements which take the device off
line when it senses current of 13 times
the maximum switch rating.
Class 11 - 3RV manual starters can be
used as Type E self-protected manual
combination starters (up to 22 amps)
per UL508 or as components in
Group Installation per NEC 430.53.
When using the Class 11 - 3RV as a
manual combination starter upstream
protection is not required.
Class 11 - 3RV controllers are available
with low voltage protection which will
automatically open the power poles
when the voltage drops or the power
is interrupted.
Controllers with the LVP option provide
the OSHA requirements for ­protecting
personnel from potential injury caused
by the automatic start-up of machinery
following a voltage drop or power
interruption when low voltage
protection is specified.
Class 11 - 3RV is available as Open
style, or in NEMA 1, NEMA 7 & 9 or
NEMA 7 & 9 / 3 & 4 enclosures.
Standard Features include:
b ON/OFF rotary handle with lockout
and visible trip indication
b Adjustment dial for setting to motor
FLA (Starters only)
b Low Voltage Protection (LVP) Option
b Short Circuit trip at 13 times the
maximum setting of the FLA dial
or rated current
b Ambient compensated up to 140°F
b Phase loss sensitivity
b Test trip function
b LVP Option Meets OSHA
Requirements
b UL Listed
b CSA Certified
NEMA & General
Purpose Control
Class 11 - 3RV switches provide
control for inherently protected motors.
Typical applications include metal and
woodworking machinery, grinders,
power saws, conveyors, fans, pumps,
General
17
CONTROL
PRODUCTS
OPEN TYPE
Starter
NEMA 1
General Purpose
NEMA 7 & 9
Div 1 & Div 2
Class I Group C & D
Class II Group E, F & G
NEMA 3 & 4, NEMA 7 & 9
Div 1 & Div 2
Class I Group C & D
Class II Group E, F & G
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
17-9
Manual Control
Starters and Switches, Class 11 - 3RV
Selection
Ordering Information
Low Voltage Protection Coil Table





No heaters required.
Field Modification Kits see page 17-91.
Dimensions see page 17-115.
Wiring Diagrams see page 17-143.
For applications requiring a low voltage protection coil
see table at right.
Class 11 Manual Motor Starter
60 Hz Voltage
Letter
120V
208V
240V
460V
*F
*D
*G
*H
*Add corresponding letter to end of base Class 11
catalog number for low voltage protection coil with
List Price adder.
Note: The LVP option for Open type 3RV is available
from the factory, please order separately from the
field modification kits on page 17-92.
The coil voltage should correspond with the
line voltage.
Manual Starter—Class 11 - 3RV
CONTROL
PRODUCTS
17
NEMA & General
Purpose Control
FLA
Adjustment
Rangea
Max HP
Single Phase
HP Ratings
3-Phase Enclosure
Open Type
HP Ratings 115V
230V
200V
230V
460V
575V
Catalog Number
0.11-0.16
0.14-0.2
0.18-0.25
0.22-0.32
0.28-0.4
0.35-0.5
0.45-0.63
0.55-0.8
0.7-1
0.9-1.25
1.1-1.6
1.4-2
1.8-2.5
2.2-3.2
2.8-4
3.5-5
4.5-6.3
5.5-8
7-10
9-12.5
11-16
14-20
17-22
20-25
—
—
—
—
—
—
—
—
—
—
—
—
—
1
⁄10
1
⁄8
1
⁄6
1
⁄4
1
⁄3
1
⁄2
1
⁄2
1
1 1⁄2
2
2c
—
—
—
—
—
—
—
—
—
—
1
⁄10
1
⁄8
1
⁄6
1
⁄4
1
⁄3
1
⁄2
3
⁄4
1
1 1⁄2
2
3
3
3
5c
—
—
—
—
—
—
—
—
—
—
—
—
1
⁄2
3
⁄4
3
⁄4
1
1 1⁄2
2
3
3
5
5
7 1⁄2
7 1⁄2c
—
—
—
—
—
—
—
—
—
—
—
—
1
⁄2
3
⁄4
1
1
1 1⁄2
2
3
3
5
7 1⁄2
7 1⁄2
7 1⁄2c
—
—
—
—
—
—
—
—
1
⁄2
3
⁄4
3
⁄4
1
1 1⁄2
1 1⁄2
2
3
5
5
7 1⁄2
7 1⁄2
10
15
15
15c
—
—
—
—
—
—
—
1
⁄2
1
⁄2
3
⁄4
1
1 1⁄2
1 1⁄2
2
3
3
5
5
10
10
15c
20c
20c
20c
NEMA 1
NEMA 7 & 9
General Purpose
Class I Groups C & D
Class II Groups E, F & G
List Price $ Catalog Number List Price $. Catalog Number List Price $
3RV1021-0AA10 b
3RV1021-0BA10 b
3RV1021-0CA10 b
3RV1021-0DA10 b
3RV1021-0EA10 b
3RV1021-0FA10 b
3RV1021-0GA10 b
3RV1021-0HA10 b
3RV1021-0JA10 b
3RV1021-0KA10 b
3RV1021-1AA10 b
3RV1021-1BA10 b
3RV1021-1CA10 b
3RV1021-1DA10 b
3RV1021-1EA10 b
3RV1021-1FA10 b
3RV1021-1GA10 b
3RV1021-1HA10 b
3RV1021-1JA10 b
3RV1021-1KA10 b
3RV1021-4AA10 b
3RV1021-4BA10 b
3RV1021-4CA10 b
3RV1021-4DA10 b
11AD3B
11BD3B
11CD3B
11DD3B
11ED3B
11FD3B
11GD3B
11HD3B
11JD3B
11KD3B
11LD3B
11MD3B
11ND3B
11PD3B
11QD3B
11RD3B
11SD3B
11TD3B
11UD3B
11VD3B
11WD3B
11XD3B
11YD3B
11ZD3B
NEMA 1
11AD3H
11BD3H
11CD3H
11DD3H
11ED3H
11FD3H
11GD3H
11HD3H
11JD3H
11KD3H
11LD3H
11MD3H
11ND3H
11PD3H
11QD3H
11RD3H
11SD3H
11TD3H
11UD3H
11VD3H
11WD3H
11XD3H
11YD3H
11ZD3H
NEMA 3 & 4, NEMA 7 & 9 d
Watertight (Outdoor use)
Class I Groups C & D
Class II Groups E, F & G
Catalog Number List Price $
11AD3W
11BD3W
11CD3W
11DD3W
11ED3W
11FD3W
11GD3W
11HD3W
11JD3W
11KD3W
11LD3W
11MD3W
11ND3W
11PD3W
11QD3W
11RD3W
11SD3W
11TD3W
11UD3W
11VD3W
11WD3W
11XD3W
11YD3W
11ZD3W
Manual Switch—Class 11 - 3RV
Rated
Currenta
Max HP
Single Phase
HP Ratings
3-Phase 115V
230V
200V
230V
460V
575V
—
—
1 c
2 1 c
2 2c
1 1⁄2c
3c
5c
—
1c
3c
7 1⁄2c
7 1⁄2 c
1 c
2 1 c
6 —
1 c
3 c
5c
7 1⁄2c
3c
7 1⁄2c
15c
15c
3 c
10c
20c
20c
a Instantaneous
⁄
⁄
Magnetic Trip will occur at 13 times
the maximum FLA dial setting or rated switch current.
b Product Category: IEC
17-10
HP Ratings
1
5
10
20
25
⁄
1 c
⁄2 1 1⁄2c
Enclosure
Open Type
⁄
Catalog Number
General Purpose
NEMA 7 & 9
Class I Groups C & D
Class II Groups E, F & G
List Price $. Catalog Number List Price $ Catalog Number List Price $
3RV1321-0JC10 b
3RV1321-1FC10 b
3RV1321-1JC10 b
3RV1321-4BC10 b
3RV1321-4DC10 b
c Shaded
111D3B
112D3B
113D3B
114D3B
115D3B
Ratings apply for Manual Motor Controllers
Only! These Ratings do not apply as UL Listed Manual
Combination Starters.
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
111D3H
112D3H
113D3H
114D3H
115D3H
NEMA 3 & 4, NEMA 7 & 9
Watertight
Class I Groups C & D
Class II Groups E, F & G
Catalog Number List Price $
111D3W
112D3W
113D3W
114D3W
115D3W
d Add
1 to the end of the catalog number for 1/2 inch drain
hole with plug and list price adder. Drain fitting not supplied, order separately XDB-2.
Product Category: NEMA